@article{KernZischank1988, author = {Kern, Alexander and Zischank, Wolfgang J.}, title = {Melting effects on metal sheets and air termination wires caused by direct lightning strikes}, series = {Conference proceedings : Graz, {\"O}sterreich, 25. - 29. April 1988 / Gesamtorganisation: {\"O}sterr. Verb. f{\"u}r Elektrotechnik ({\"O}VE), Fachausschuß Blitzschutz ... [Red.: G. Diendorfer ...]}, journal = {Conference proceedings : Graz, {\"O}sterreich, 25. - 29. April 1988 / Gesamtorganisation: {\"O}sterr. Verb. f{\"u}r Elektrotechnik ({\"O}VE), Fachausschuß Blitzschutz ... [Red.: G. Diendorfer ...]}, publisher = {Eigenverl. des {\"O}VE}, address = {Wien}, isbn = {3-85133-001-3}, year = {1988}, language = {en} } @article{Kern1989, author = {Kern, Alexander}, title = {Time dependent temperature distribution in metal sheets caused by direct lightning strikes}, series = {Proceedings / Sixth International Symposium on High Voltage Engineering : 28. August - 1. September, 1989, Westin Canal Place Hotel, New Orleans, Louisiana, USA}, journal = {Proceedings / Sixth International Symposium on High Voltage Engineering : 28. August - 1. September, 1989, Westin Canal Place Hotel, New Orleans, Louisiana, USA}, publisher = {Mississippi State University}, address = {Mississippi State, Miss.}, year = {1989}, language = {en} } @article{KernLangWiesingeretal.1989, author = {Kern, Alexander and Lang, U. and Wiesinger, J. and Zischank, Wolfgang J.}, title = {The longitudinal voltage of cable tubes with a screening mesh caused by partial lightning currents}, series = {Proceedings / Sixth International Symposium on High Voltage Engineering : 28. August - 1. September, 1989, Westin Canal Place Hotel, New Orleans, Louisiana, USA}, journal = {Proceedings / Sixth International Symposium on High Voltage Engineering : 28. August - 1. September, 1989, Westin Canal Place Hotel, New Orleans, Louisiana, USA}, publisher = {Mississippi State University}, address = {Mississippi State, Miss.}, year = {1989}, language = {en} } @article{Kern1990, author = {Kern, Alexander}, title = {The heating of metal sheets caused by direct lightning strikes-model and measurement}, series = {20th ICPL / International Conference on Lightning Protection, Congress-Center Casino Interlaken, Switzerland, September 24-28, 1990 = Internationale Blitzschutzkonferenz, Congress-Center Casino Interlaken, Schweiz, 24.-28. September 1990}, journal = {20th ICPL / International Conference on Lightning Protection, Congress-Center Casino Interlaken, Switzerland, September 24-28, 1990 = Internationale Blitzschutzkonferenz, Congress-Center Casino Interlaken, Schweiz, 24.-28. September 1990}, publisher = {Schweizerischer Elektrotechnischer Verein}, address = {[Z{\"u}rich]}, pages = {[522] S. (getr. Z{\"a}hl.) : Ill.}, year = {1990}, language = {en} } @article{KernWiesingerZischank1991, author = {Kern, Alexander and Wiesinger, J. and Zischank, Wolfgang J.}, title = {Calculation of the longitudinal voltage along metal tubes caused by lightning currents and protection measures}, series = {Seventh International Symposium on High Voltage Engineering : Dresden, August 26 - 30 1991}, journal = {Seventh International Symposium on High Voltage Engineering : Dresden, August 26 - 30 1991}, publisher = {Techn. Univ.}, address = {Dresden}, year = {1991}, language = {en} } @article{Kern1991, author = {Kern, Alexander}, title = {Simulation and measurement of melting effects on metal sheets caused by direct lightning strikes}, series = {1991 International Aerospace and Ground Conference on Lightning and Static Electricity : proceedings of a conference ... held at Cocoa Beach, Florida, April 16-19, 1991 / NASA}, journal = {1991 International Aerospace and Ground Conference on Lightning and Static Electricity : proceedings of a conference ... held at Cocoa Beach, Florida, April 16-19, 1991 / NASA}, address = {Washington, DC}, year = {1991}, language = {en} } @article{KernRothWiedmann1992, author = {Kern, Alexander and Roth, J. and Wiedmann, J.}, title = {Comparison of the damage for various types of fibre reinforced composites due to different lightning test standards (MIL-STD 1757 A, German military VG-standard 96903)}, series = {Proceedings of the 1992 International Aerospace and Ground Conference on Lightning and Static Electricity : October 6-8, 1992, Trump Taj Mahal, Atlantic City, NJ.}, journal = {Proceedings of the 1992 International Aerospace and Ground Conference on Lightning and Static Electricity : October 6-8, 1992, Trump Taj Mahal, Atlantic City, NJ.}, publisher = {U.S. Dept. of Transportation, Federal Aviation Administration}, address = {[Atlantic City, N.J.]}, pages = {Getr. Z{\"a}hl. : Ill. + addendum}, year = {1992}, language = {en} } @article{KernZischank1992, author = {Kern, Alexander and Zischank, Wolfgang J.}, title = {The effect of parallel wires on the longitudinal voltage drop along shielded cables}, series = {Conference proceedings : 21st International Conference on Lightning Protection, Berlin Congress Center (BCC) Germany, September 22 - 25, 1992 = 21. Internationale Blitzschutzkonferenz / [proceedings ed. staff: J. Pilling ...]}, journal = {Conference proceedings : 21st International Conference on Lightning Protection, Berlin Congress Center (BCC) Germany, September 22 - 25, 1992 = 21. Internationale Blitzschutzkonferenz / [proceedings ed. staff: J. Pilling ...]}, publisher = {VDE-Verl.}, address = {Berlin [u.a.]}, isbn = {3-8007-1885-5}, pages = {570 S : Ill., graph. Darst., Kt.}, year = {1992}, language = {en} } @article{KernThomsen1994, author = {Kern, Alexander and Thomsen, M.}, title = {Comparison of single point and equipotential bonding for I\&C systems of large-area industrial sites}, series = {Volume of proceedings : Budapest, Hungary, September 19-23, 1994 / organized by: Technical University of Budapest}, journal = {Volume of proceedings : Budapest, Hungary, September 19-23, 1994 / organized by: Technical University of Budapest}, publisher = {Techn. Univ.}, address = {Budapest}, pages = {Getr. Z{\"a}hlung [ca. 610 S.]}, year = {1994}, language = {en} } @article{KernDrumm1994, author = {Kern, Alexander and Drumm, F.}, title = {Survey of the lightning threat for aircraft based on natural lightning data and fixed in the German Standard DIN VG 95371 / Part 10}, series = {Proceedings of the 1994 International Aerospace and Ground Conference on Lightning and Static Electricity : May 14 - 27, 1994, Bundesakademie f{\"u}r Wehrverwaltung und Wehrtechnik Mannheim ; final report / [conference chairman Jan Luiken TerHaseborg]}, journal = {Proceedings of the 1994 International Aerospace and Ground Conference on Lightning and Static Electricity : May 14 - 27, 1994, Bundesakademie f{\"u}r Wehrverwaltung und Wehrtechnik Mannheim ; final report / [conference chairman Jan Luiken TerHaseborg]}, publisher = {Bundesakad. f{\"u}r Wehrverwaltung und Wehrtechnik}, address = {Mannheim}, pages = {IX, 492 S : Ill., graph. Darst}, year = {1994}, language = {en} } @article{KernZischankHeidleretal.1998, author = {Kern, Alexander and Zischank, Wolfgang J. and Heidler, Fridolin and Wiesinger, J. [u.a.]}, title = {Shielding effectiveness of reinforced concrete cable ducts carrying partial lightning currents}, series = {Conference proceedings : 14th - 18th September 1998, [Burlington Hotel, Birmingham, United Kingdom] / organised by: School of Engineering and Advanced Technology, Staffordshire University, United Kingdom}, journal = {Conference proceedings : 14th - 18th September 1998, [Burlington Hotel, Birmingham, United Kingdom] / organised by: School of Engineering and Advanced Technology, Staffordshire University, United Kingdom}, address = {Birmingham}, year = {1998}, language = {en} } @article{KernHeidlerZischank1998, author = {Kern, Alexander and Heidler, F. and Zischank, W.}, title = {Induced overvoltages in cable ducts taking into account the current flow into earth / F. Heidler ; W. Zischank ... A. Kern ...}, series = {Conference proceedings : 14th - 18th September 1998, [Burlington Hotel, Birmingham, United Kingdom] / organised by: School of Engineering and Advanced Technology, Staffordshire University, United Kingdom}, journal = {Conference proceedings : 14th - 18th September 1998, [Burlington Hotel, Birmingham, United Kingdom] / organised by: School of Engineering and Advanced Technology, Staffordshire University, United Kingdom}, address = {Birmingham}, year = {1998}, language = {en} } @inproceedings{ZischankKernFrentzeletal.2000, author = {Zischank, Wolfgang J. and Kern, Alexander and Frentzel, Ralf and Heidler, Fridolin and Seevers, M.}, title = {Assessment of the lightning transient coupling to control cables interconnecting structures in large industrial facilities and power plants}, year = {2000}, abstract = {Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I\&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I\&C-cables.}, language = {en} } @article{KernKrichelNeskakisetal.2001, author = {Kern, Alexander and Krichel, Frank and Neskakis, Apostolos and M{\"u}ller, Klaus-Peter (u.a.)}, title = {Lightning protection design of a renewable energy hybrid-system without power mains connection}, year = {2001}, language = {en} } @inproceedings{KernKrichelMueller2001, author = {Kern, Alexander and Krichel, Frank and M{\"u}ller, Klaus-Peter}, title = {Lightning protection design of a renewable energy hybrid-system without power mains connection}, year = {2001}, abstract = {In the year 2000 a direct lightning strike to the hybridsystem without power mains connection VATALI on the Greek island Crete results in the destruction and damage of some mechanical and electrical components. The hybrid-system VATALI was not lightning protected at that time. The hardware damage costs are approx. 60,000 €. The exposed site of the hybrid-system on top of a mountain was and still is the reason for a high risk of lightning strikes. Also in the future further lightning strikes have to be taken into consideration. In the paper a fundamental lightning protection design concept for renewable energy hybrid-systems without power mains connection and protection measures against direct strikes and overvoltages are shown in detail. The design concept was realized exemplarily for the hybrid-system VATALI. The hardware costs for the protection measures were about 15,000 €. About 50\% of the costs are due to protection measures against direct strikes, 50\% are due to overvoltage protection. Future extensions, new installations, or modifications have to be included into the lightning protection design concept of the hybrid-system.}, language = {en} } @article{KernHeidlerZischanketal.2002, author = {Kern, Alexander and Heidler, Fridolin and Zischank, Wolfgang J. and Frentzel, Ralf}, title = {Lightning current distribution and coupling to control cables in power plants or large industrial facilites}, year = {2002}, language = {en} } @inproceedings{DarvenizaFlisowskiKernetal.2002, author = {Darveniza, M. and Flisowski, Z. and Kern, Alexander and Landers, E.-U. and LoPiparo, G. and Mazzetti, C. and Rousseau, A. and Sherlock, J.}, title = {Application problems of the probabilistic approach to the assessment of risk for structures and services}, year = {2002}, abstract = {The paper deals with the development of the probabilistic approach to the assessment of risk due to lightning. Sources of damage, types of damage and types of loss are defined and, accordingly, the procedure for risk analysis and the way of assessment of different risk components is proposed. The way to evaluate the influence of different protection measures (lightning protection system; shielding of structure, cables and equipment; routing of internal wiring; surge protective device) in reducing such probabilities is considered. The paper has been prepared within the framework of the activity of IEC TC81-WG9/CLC TC81-WG4 directed to prepare the draft IEC 62305-2 Risk Management, in cooperation with the Secretary of IEC/CLC TC81.}, language = {en} } @inproceedings{KernKrichel2002, author = {Kern, Alexander and Krichel, Frank}, title = {Considerations about the lightning protection system of mains independent renewable energy hybrid-systems - practical experiences}, year = {2002}, abstract = {In the paper a lightning protection design concept for renewable energy hybrid-systems without power mains connection is described. Based on a risk analysis protection measures against direct strikes and overvoltages are shown in an overview. The design concept is realized exemplarily for the hybrid-system VATALI on the Greek island Crete. VATALI, not lightning protected at that time, was a victim of a lightning strike in the year 2000 causing destructions and damages of some mechanical and electrical components with costs of approx. 60.000 €. The hardware costs for the protection measures were about 15.000 €: about 50\% of the costs are due to protection measures against direct strikes, 50\% are due to overvoltage protection.}, language = {en} } @inproceedings{ZischankHeidlerKernetal.2002, author = {Zischank, Wolfgang J. and Heidler, Fridolin and Kern, Alexander and Metwally, I. A. and Wiesinger, J. and Seevers, M.}, title = {Laboratory simulation of direct lightning strokes to a modelled building - measurement of magnetic fields and induced voltages}, year = {2002}, abstract = {In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between "floor" and "roof" in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived.}, language = {en} } @article{KernKrichel2004, author = {Kern, Alexander and Krichel, Frank}, title = {Considerations about the lightning protection system of mains independent renewable energy hybrid-systems - practical experiences}, series = {Journal of electrostatics. 60 (2004), H. 2-4}, journal = {Journal of electrostatics. 60 (2004), H. 2-4}, isbn = {0304-3886}, pages = {257 -- 263}, year = {2004}, language = {en} } @article{ZischankHeidlerWiesingeretal.2004, author = {Zischank, Wolfgang J. and Heidler, Fridolin and Wiesinger, J. and Metwally, I. and Kern, Alexander and Seevers, M.}, title = {Laboratory simulation of direct lightning strokes to a modeled building : measurement of magnetic fields and included voltages}, series = {Journal of electrostatics. 60 (2004), H. 2 - 4}, journal = {Journal of electrostatics. 60 (2004), H. 2 - 4}, isbn = {0304-3886}, pages = {223 -- 232}, year = {2004}, language = {en} } @inproceedings{SurteesGillespieKernetal.2004, author = {Surtees, A. J. and Gillespie, A. and Kern, Alexander and Rousseau, A.}, title = {DEVELOPMENT OF A RISK ASSESSMENT CALCULATOR BASED ON A SIMPLIFIED FORM OF THE IEC 62305-2 STANDARD ON LIGHTNING PROTECTION}, year = {2004}, abstract = {Neue Blitzschutznorm IEC 62305. Entwicklung einer einfachen Software zur Risikoabw{\"a}gung}, language = {en} } @inproceedings{KernHeidlerSeeversetal.2004, author = {Kern, Alexander and Heidler, Fridolin and Seevers, M. and Zischank, Wolfgang J.}, title = {Magnetic Fields and Induced Voltages in case of a Direct Strike - Comparison of Results obtained from Measurements at a Scaled Building to those of IEC 62305-4}, isbn = {0304-3886}, year = {2004}, abstract = {In the paper the results obtained from experiments at a modelled reinforced building in case of a direct lightning strike are compared with calculations. The comparison includes peak values of the magnetic field Hmax, its derivative (dH/dt)max and of induced voltages umax in typical cable routings. The experiments are performed at a 1:6 scaled building and the results are extrapolated using the similarity relations theory. The calculations are based on the approximate formulae given in IEC 62305-4 and have to be supplemented by a rough estimation of the additional shielding effect of a second reinforcement layer. The comparison shows, that the measured peak values of the magnetic field and its derivative are mostly lower than the calculated. The induced voltages are in good agreement. Hence, calculations of the induced voltages based on IEC 62305-4 are a good method for lightning protection studies of buildings, where the reinforcement is used as a grid-like electromagnetic shield.}, subject = {Blitz}, language = {en} } @inproceedings{ZischankHeidlerWiesingeretal.2004, author = {Zischank, Wolfgang J. and Heidler, Fridolin and Wiesinger, J. and Stimper, K. and Kern, Alexander and Seevers, M.}, title = {Magnetic Fields and Induced Voltages inside LPZ 1 Measured at a 1:6 Scale Model Building}, year = {2004}, abstract = {Laborexperimente zu Blitzschutzzonen in Stahlbetongeb{\"a}uden anhand eines Modells im Maßstab 1:6}, language = {en} } @inproceedings{KernDikta2009, author = {Kern, Alexander and Dikta, Gerhard}, title = {Probability of damage of electrical and electronic systems due to indirect lightning flashes - investigation of data from German insurance companies}, year = {2009}, abstract = {In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not.}, subject = {Blitzschutz}, language = {en} } @article{BouquegneauKernRousseau2010, author = {Bouquegneau, Christian and Kern, Alexander and Rousseau, Alain}, title = {Lightning safety guidelines}, pages = {1 -- 6}, year = {2010}, language = {en} } @article{KernFrentzelBehrens2010, author = {Kern, Alexander and Frentzel, Ralf and Behrens, J{\"o}rg}, title = {Simulation of the transient voltages in the auxiliary power network of a large power plant in case of a direct lightning strike to the high-voltage overhead transmission line}, pages = {749-1 -- 749-7}, year = {2010}, language = {en} } @article{KernKloetersPferdemenges2010, author = {Kern, Alexander and Kl{\"o}ters, Georg and Pferdemenges, J{\"o}rg}, title = {Optimised protection against lightning for the signalling and safety systems of level crossings on non-electrified railway lines}, series = {RTR : European Rail Technology Review}, volume = {50}, journal = {RTR : European Rail Technology Review}, number = {2}, isbn = {0079-9548}, year = {2010}, language = {en} } @article{KernSchelthoffMathieu2010, author = {Kern, Alexander and Schelthoff, Christof and Mathieu, Moritz}, title = {Probability of lightning strikes to air-terminations of structures using the electro-geometrical model theory and the statistics of lightning current parameters}, pages = {750-1 -- 750-8}, year = {2010}, language = {en} } @article{KernSchelthoffMathieu2011, author = {Kern, Alexander and Schelthoff, Christof and Mathieu, Moritz}, title = {Calculation of interception efficiencies for airterminations using a dynamic electro-geometrical model}, publisher = {IEEE}, address = {New York}, pages = {1 -- 6}, year = {2011}, language = {en} } @article{LandersKern2011, author = {Landers, Ernst Ulrich and Kern, Alexander}, title = {Future evolution of risk management for structures : Advancement for the future IEC 62305-2 Ed3}, publisher = {IEEE}, address = {New York}, pages = {1 -- 6}, year = {2011}, language = {en} } @article{KernSchelthoffMathieu2011, author = {Kern, Alexander and Schelthoff, Christof and Mathieu, Moritz}, title = {Probability of lightning strikes to air-terminations of structures using the electro-geometrical model theory and the statistics of lightning current parameters}, series = {Atmospheric Research. 104 (2011)}, journal = {Atmospheric Research. 104 (2011)}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0169-8095}, year = {2011}, language = {en} } @inproceedings{KernSchelthoffMathieu2012, author = {Kern, Alexander and Schelthoff, Christof and Mathieu, Moritz}, title = {Calculation of interception efficiencies for mesh-type air-terminations according to IEC 62305-3 using a dynamic electro-geometrical model}, series = {International Conference on Lightning Protection (ICLP) : 2 - 7 Sept. 2012, Vienna}, booktitle = {International Conference on Lightning Protection (ICLP) : 2 - 7 Sept. 2012, Vienna}, publisher = {IEEE}, address = {Piscataway, NJ}, organization = {International Conference on Lightning Protection <2012, Wien>}, isbn = {978-1-4673-1896-9 (E-Book) ; 978-1-4673-1898-3 (Print)}, pages = {1 -- 6}, year = {2012}, language = {en} } @inproceedings{LoPiparoKernMazzetti2012, author = {Lo Piparo, G. B. and Kern, Alexander and Mazzetti, C.}, title = {Some masterpoints about risk due to lightning}, series = {International Conference on Lightning Protection (ICLP) : 2 - 7 Sept. 2012, Vienna}, booktitle = {International Conference on Lightning Protection (ICLP) : 2 - 7 Sept. 2012, Vienna}, publisher = {IEEE}, address = {Piscataway, NJ}, organization = {International Conference on Lightning Protection <2012, Wien>}, isbn = {978-1-4673-1896-9 (E-Book) ; 978-1-4673-1898-3 (Print)}, pages = {1 -- 6}, year = {2012}, language = {en} } @inproceedings{WetterKern2014, author = {Wetter, Martin and Kern, Alexander}, title = {Number of lightning strikes to tall structures - comparison of calculations and measurements using a modern lightning monitoring system}, series = {2014 International Conference on Lightning Protection (ICLP), Shanghai, China}, booktitle = {2014 International Conference on Lightning Protection (ICLP), Shanghai, China}, organization = {International Conference on Lightning Protection <2014, Shanghai>}, pages = {1 -- 7}, year = {2014}, language = {en} } @inproceedings{RousseauKern2014, author = {Rousseau, Alain and Kern, Alexander}, title = {How to deal with environmental risk in IEC 62305-2}, series = {2014 International Conference on Lightning Protection (ICLP), Shanghai, China}, booktitle = {2014 International Conference on Lightning Protection (ICLP), Shanghai, China}, organization = {International Conference on Lightning Protection <2014, Shanghai>}, pages = {521 -- 527}, year = {2014}, abstract = {The 2nd edition of the lightning risk management standard (IEC 62305-2) considers structures, which may endanger environment. In these cases, the loss is not limited to the structure itself, which is valid for usual structures. In the past (Edition 1) this danger was simply taken into account by a special hazard factor, multiplying the existing risk for the structure with a number. Now, in the edition 2, we add to the risk for the structure itself a "second risk" due to the losses outside the structure. The losses outside can be treated independently from what occurs inside. This is a major advantage to analyze the risk for sensitive structures, like chemical plants, nuclear plants, or structures containing explosives, etc. In this paper, the existing procedure given by the European version EN 62305-2 Ed.2 is further developed and applied to a few structures.}, language = {en} } @inproceedings{KernBraun2014, author = {Kern, Alexander and Braun, Christian}, title = {Risk management according to IEC 62305-2 edition 2: 2010-12 assessment of structures with a risk of explosion}, series = {2014 International Conference on Lightning Protection (ICLP), Shanghai, China}, booktitle = {2014 International Conference on Lightning Protection (ICLP), Shanghai, China}, organization = {International Conference on Lightning Protection <2014, Shanghai>}, pages = {1237 -- 1242}, year = {2014}, abstract = {Risk management for structures with a risk of explosion should be considered very carefully when performing a risk analysis according to IEC 62305-2. In contrast to the 2006 edition of the standard, the 2010 edition describes the topic "Structures with a risk of explosion" in more detail. Moreover, in Germany separate procedures and parameters are defined for the risk analysis of structures with a risk of explosion (Supplement 3 of the German DIN EN 62305-2 standard). This paper describes the contents and the relevant calculations of this Supplement 3, together with a numerical example.}, language = {en} } @inproceedings{BirklDiendorferKernetal.2018, author = {Birkl, Josef and Diendorfer, Gerhard and Kern, Alexander and Thern, Stephan}, title = {Extremely high lightning peak currents}, series = {34th International Conference on Ligntning Protection, 02-07 September 2018}, booktitle = {34th International Conference on Ligntning Protection, 02-07 September 2018}, isbn = {978-1-5386-6635-7}, pages = {7 Seiten}, year = {2018}, language = {en} } @inproceedings{KernImaniVashianiTimmermanns2021, author = {Kern, Alexander and Imani Vashiani, Anahita and Timmermanns, Tobias}, title = {Threat for human beings due to touch voltages and body currents caused by direct lightning strikes in case of non-isolated lightning protection systems using natural components}, series = {35th International Conference on Lightning Protection (ICLP) and XVI International Symposium on Lightning Protection (SIPDA)}, booktitle = {35th International Conference on Lightning Protection (ICLP) and XVI International Symposium on Lightning Protection (SIPDA)}, publisher = {IEEE}, isbn = {978-1-6654-2346-5}, doi = {10.1109/ICLPandSIPDA54065.2021.9627465}, pages = {8 Seiten}, year = {2021}, abstract = {For typical cases of non-isolated lightning protection systems (LPS) the impulse currents are investigated which may flow through a human body directly touching a structural part of the LPS. Based on a basic LPS model with conventional down-conductors especially the cases of external and internal steel columns and metal fa{\c{c}}ades are considered and compared. Numerical simulations of the line quantities voltages and currents in the time domain are performed with an equivalent circuit of the entire LPS. As a result it can be stated that by increasing the number of conventional down-conductors and external steel columns the threat for a human being can indeed be reduced, but not down to an acceptable limit. In case of internal steel columns used as natural down-conductors the threat can be reduced sufficiently, depending on the low-resistive connection of the steel columns to the lightning equipotential bonding or the earth termination system, resp. If a metal fa{\c{c}}ade is used the threat for human beings touching is usually very low, if the fa{\c{c}}ade is sufficiently interconnected and multiply connected to the lightning equipotential bonding or the earth termination system, resp.}, language = {en} }