@article{MykoniouButenwegHoltschoppenetal.2016, author = {Mykoniou, Konstantin and Butenweg, Christoph and Holtschoppen, Britta and Klinkel, Sven}, title = {Seismic response analysis of adjacent liquid-storage tanks}, series = {Earthquake engineering and structural dynamics}, volume = {45}, journal = {Earthquake engineering and structural dynamics}, number = {11}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1096-9845 (E-Journal); 0098-8847 (Print)}, doi = {10.1002/eqe.2726}, pages = {1779 -- 1796}, year = {2016}, abstract = {A refined substructure technique in the frequency domain is developed, which permits consideration of the interaction effects among adjacent containers through the supporting deformable soil medium. The tank-liquid systems are represented by means of mechanical models, whereas discrete springs and dashpots stand for the soil beneath the foundations. The proposed model is employed to assess the responses of adjacent circular, cylindrical tanks for harmonic and seismic excitations over wide range of tank proportions and soil conditions. The influence of the number, spatial arrangement of the containers and their distance on the overall system's behavior is addressed. The results indicate that the cross-interaction effects can substantially alter the impulsive components of response of each individual element in a tank farm. The degree of this impact is primarily controlled by the tank proportions and the proximity of the predominant natural frequencies of the shell-liquid-soil systems and the input seismic motion. The group effects should be not a priori disregarded, unless the tanks are founded on shallow soil deposit overlying very stiff material or bedrock.}, language = {en} } @article{GivanoudiCornelisRasschaertetal.2021, author = {Givanoudi, Stella and Cornelis, Peter and Rasschaert, Geertrui and Wackers, Gideon and Iken, Heiko and Rolka, David and Yongabi, Derick and Robbens, Johan and Sch{\"o}ning, Michael Josef and Heyndrickx, Marc and Wagner, Patrick}, title = {Selective Campylobacter detection and quantification in poultry: A sensor tool for detecting the cause of a common zoonosis at its source}, series = {Sensors and Actuators B: Chemical}, journal = {Sensors and Actuators B: Chemical}, number = {In Press, Journal Pre-proof}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2021.129484}, pages = {Article 129484}, year = {2021}, language = {en} } @article{KotterLintzTurek1992, author = {Kotter, Michael and Lintz, Hans-G{\"u}nther and Turek, Thomas}, title = {Selective catalytic reduction of nitrogen oxide by use of the Ljungstroem air heater as reactor : a case study}, series = {Chemical engineering science . 47 (1992), H. 9-11}, journal = {Chemical engineering science . 47 (1992), H. 9-11}, isbn = {0009-2509}, pages = {2763 -- 2768}, year = {1992}, language = {en} } @article{HoetterFateriGebhardt2012, author = {H{\"o}tter, Jan-Steffen and Fateri, Miranda and Gebhardt, Andreas}, title = {Selective laser melting of metals: desktop machines open up new chances even for small companies}, series = {Advanced materials research}, volume = {622-623}, journal = {Advanced materials research}, publisher = {Trans Tech Publ.}, address = {Baech}, issn = {1662-8985 (E-Journal); 1022-6680 (Print)}, doi = {10.4028/www.scientific.net/AMR.622-623.461}, pages = {461 -- 465}, year = {2012}, abstract = {Additive manufacturing (AM) of metal parts by using Selective Laser Melting (SLM) has become a powerful tool mostly in the area of automotive, aerospace engineering and others. Especially in the field of dentistry, jewelry and related branches that require individualized or even one-of-a-kind products, the direct digital manufacturing process opens up new ways of design and manufacturing. In these fields, mostly small and medium sized businesses (SME) are operating which do not have sufficient human and economic resources to invest in this technology. But to stay competitive, the application of AM can be regarded as a necessity. In this situation a new desktop machine (Realizer SLM 50) was introduced that cost about 1/3 of a shop floor SLM machine and promises small quality parts. To find out whether the machine really is an alternative for SMEs the University of Applied Science, Aachen, Germany, designed, build and optimized typical parts from the dentistry and the jewelry branches using CoCr and silver material, the latter being new with this application. The paper describes the SLM procedure and how to find and optimize the most important parameters. The test is accompanied by digital simulation in order to verify the build parameters and to plan future builds. The procedure is shown as well as the resulting parts made from CoCr and silver material.}, language = {en} } @article{FateriGebhardt2015, author = {Fateri, Miranda and Gebhardt, Andreas}, title = {Selective Laser Melting of Soda-Lime Glass Powder}, series = {International Journal of Applied Ceramic Technology}, volume = {12}, journal = {International Journal of Applied Ceramic Technology}, number = {1}, publisher = {Wiley-Blackwell}, address = {Oxford}, issn = {1744-7402}, doi = {10.1111/ijac.12338}, pages = {53 -- 61}, year = {2015}, language = {en} } @article{RieperGebhardtStucker2016, author = {Rieper, Harald and Gebhardt, Andreas and Stucker, Brent}, title = {Selective Laser Melting of the Eutectic Silver-Copper Alloy Ag 28 wt \% Cu}, series = {RTejournal - Forum f{\"u}r Rapid Technologie}, volume = {13}, journal = {RTejournal - Forum f{\"u}r Rapid Technologie}, issn = {1614-0923}, url = {http://nbn-resolving.de/nbn:de:0009-2-44141}, year = {2016}, abstract = {The aim of this work was to perform a detailed investigation of the use of Selective Laser Melting (SLM) technology to process eutectic silver-copper alloy Ag 28 wt. \% Cu (also called AgCu28). The processing occurred with a Realizer SLM 50 desktop machine. The powder analysis (SEM-topography, EDX, particle distribution) was reported as well as the absorption rates for the near-infrared (NIR) spectrum. Microscope imaging showed the surface topography of the manufactured parts. Furthermore, microsections were conducted for the analysis of porosity. The Design of Experiments approach used the response surface method in order to model the statistical relationship between laser power, spot distance and pulse time.}, language = {en} } @article{MuellerVeggianHaenniBeuscheretal.1980, author = {M{\"u}ller-Veggian, Mattea and Haenni, D. R. and Beuscher, H. and Bochev, B.}, title = {Selectivity of a sum spectrometer for (a,xn) reaction}, series = {Annual report 1979 / Kernforschungsanlage J{\"u}lich Institut f{\"u}r Kernphysik / Hrsg.: A. F{\"a}ssler. - (Spezielle Berichte der Kernforschungsanlage J{\"u}lich ; 72)}, journal = {Annual report 1979 / Kernforschungsanlage J{\"u}lich Institut f{\"u}r Kernphysik / Hrsg.: A. F{\"a}ssler. - (Spezielle Berichte der Kernforschungsanlage J{\"u}lich ; 72)}, publisher = {Kernforschungsanlage}, address = {J{\"u}lich}, pages = {49}, year = {1980}, language = {en} } @article{PrielmeierLuedemann1986, author = {Prielmeier, Franz and L{\"u}demann, H.-D.}, title = {Self diffusion in compressed liquid chloromethane, dichloromethane and trichloromethane / F. X. Prielmeier; H.-D. L{\"u}demann}, series = {Molecular Physics. 58 (1986), H. 3}, journal = {Molecular Physics. 58 (1986), H. 3}, isbn = {0026-8976}, pages = {593 -- 604}, year = {1986}, language = {en} } @article{Stulpe2009, author = {Stulpe, Werner}, title = {Self-Adjoint Operator}, series = {Compendium of Quantum Physics : concepts, experiments, history and philosophy / Daniel Greenberger ... ed.}, journal = {Compendium of Quantum Physics : concepts, experiments, history and philosophy / Daniel Greenberger ... ed.}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-540-70622-9}, pages = {692 -- 697}, year = {2009}, language = {en} } @article{SpelthahnPoghossianSchoening2009, author = {Spelthahn, Heiko and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Self-aligned nanogaps and nanochannels via conventional photolithography and pattern-size reduction technique}, series = {Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI}, journal = {Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI}, isbn = {0013-4686}, pages = {6010 -- 6014}, year = {2009}, language = {en} } @article{deBloisdeZangerPaulssenetal.2018, author = {de Blois, Eric and de Zanger, Rory M. S. and Paulßen, Elisabeth and Sze Chan, Ho and Breeman, Wouter A. P.}, title = {Semi-automated system for concentrating 68Ga-eluate to obtain high molar and volume concentration of 68Ga-Radiopharmaca for preclinical applications}, series = {Nuclear Medicine and Biology}, volume = {64-65}, journal = {Nuclear Medicine and Biology}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.nucmedbio.2018.06.006}, pages = {16 -- 21}, year = {2018}, abstract = {68Ga-radiopharmaceuticals are common in the field of Nuclear Medicine to visualize receptor-mediated processes. In contrast to straightforward labeling procedures for clinical applications, preclinical in vitro and in vivo applications are hampered for reasons like e.g. volume restriction, activity concentration, molar activity and osmolality. Therefore, we developed a semiautomatic system specifically to overcome these problems. A difficulty appeared unexpectedly, as intrinsic trace metals derived from eluate (Zn, Fe and Cu) are concentrated as well in amounts that influence radiochemical yield and thus lower molar activity.}, language = {en} } @article{PawelkeButzer1968, author = {Pawelke, Siegfried and Butzer, Paul L.}, title = {Semi-groups and resolvent operators}, series = {Archive for Rational Mechanics and Analysis}, volume = {30}, journal = {Archive for Rational Mechanics and Analysis}, number = {2}, publisher = {Springer}, address = {Berlin}, issn = {0003-9527}, doi = {10.1007/BF00250941}, pages = {127 -- 147}, year = {1968}, language = {en} } @article{FoersterKordosBetko1995, author = {F{\"o}rster, Arnold and Kordos, P. and Betko, J.}, title = {Semi-insulating GaAs layers grown by molecular-beam epitaxy / P. Kordos ; A. F{\"o}rster ; J. Betko ...}, series = {Applied physics letters. 67 (1995), H. 7}, journal = {Applied physics letters. 67 (1995), H. 7}, isbn = {0003-6951}, pages = {983 -- 985}, year = {1995}, language = {en} } @article{Dikta2017, author = {Dikta, Gerhard}, title = {Semi-parametric random censorship models}, series = {From Statistics to Mathematical Finance : Festschrift in Honour of Winfried Stute}, journal = {From Statistics to Mathematical Finance : Festschrift in Honour of Winfried Stute}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-319-50986-0}, doi = {10.1007/978-3-319-50986-0_3}, pages = {43 -- 56}, year = {2017}, language = {en} } @article{DiktaReisselHarlass2016, author = {Dikta, Gerhard and Reißel, Martin and Harlaß, Carsten}, title = {Semi-parametric survival function estimators deduced from an identifying Volterra type integral equation}, series = {Journal of multivariate analysis}, journal = {Journal of multivariate analysis}, number = {147}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.jmva.2016.02.008}, pages = {273 -- 284}, year = {2016}, abstract = {Based on an identifying Volterra type integral equation for randomly right censored observations from a lifetime distribution function F, we solve the corresponding estimating equation by an explicit and implicit Euler scheme. While the first approach results in some known estimators, the second one produces new semi-parametric and pre-smoothed Kaplan-Meier estimators which are real distribution functions rather than sub-distribution functions as the former ones are. This property of the new estimators is particular useful if one wants to estimate the expected lifetime restricted to the support of the observation time. Specifically, we focus on estimation under the semi-parametric random censorship model (SRCM), that is, a random censorship model where the conditional expectation of the censoring indicator given the observation belongs to a parametric family. We show that some estimated linear functionals which are based on the new semi-parametric estimator are strong consistent, asymptotically normal, and efficient under SRCM. In a small simulation study, the performance of the new estimator is illustrated under moderate sample sizes. Finally, we apply the new estimator to a well-known real dataset.}, language = {en} } @article{SchoeningPoghossianYoshinobuetal.2001, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak and Yoshinobu, Tatsuo and L{\"u}th, Hans}, title = {Semiconductor-based field-effect structures for chemical sensing}, pages = {188 -- 198}, year = {2001}, language = {en} } @article{PoghossianAbouzarChristiaensetal.2008, author = {Poghossian, Arshak and Abouzar, Maryam H. and Christiaens, P. and Williams, O. A. and Haenen, K. and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Sensing charged macromolecules with nanocrystalline diamond-based field-effect capacitive sensors}, series = {Journal of Contemporary Physics. 43 (2008), H. 2}, journal = {Journal of Contemporary Physics. 43 (2008), H. 2}, isbn = {1934-9378}, pages = {77 -- 81}, year = {2008}, language = {en} } @article{WuPoghossianBronderetal.2016, author = {Wu, Chunsheng and Poghossian, Arshak and Bronder, Thomas and Sch{\"o}ning, Michael Josef}, title = {Sensing of double-stranded DNA molecules by their intrinsic molecular charge using the light-addressable potentiometric sensor}, series = {Sensors and Actuators B: Chemical}, journal = {Sensors and Actuators B: Chemical}, number = {229}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2016.02.004}, pages = {506 -- 512}, year = {2016}, abstract = {A multi-spot light-addressable potentiometric sensor (LAPS), which belongs to the family of semiconductor field-effect devices, was applied for label-free detection of double-stranded deoxyribonucleic acid (dsDNA) molecules by their intrinsic molecular charge. To reduce the distance between the DNA charge and sensor surface and thus, to enhance the electrostatic coupling between the dsDNA molecules and the LAPS, the negatively charged dsDNA molecules were electrostatically adsorbed onto the gate surface of the LAPS covered with a positively charged weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)). The surface potential changes in each spot of the LAPS, induced by the layer-by-layer adsorption of a PAH/dsDNA bilayer, were recorded by means of photocurrent-voltage and constant-photocurrent measurements. In addition, the surface morphology of the gate surface before and after consecutive electrostatic adsorption of PAH and dsDNA layers was studied by atomic force microscopy measurements. Moreover, fluorescence microscopy was used to verify the successful adsorption of dsDNA molecules onto the PAH-modified LAPS surface. A high sensor signal of 25 mV was registered after adsorption of 10 nM dsDNA molecules. The lower detection limit is down to 0.1 nM dsDNA. The obtained results demonstrate that the PAH-modified LAPS device provides a convenient and rapid platform for the direct label-free electrical detection of in-solution hybridized dsDNA molecules.}, language = {en} } @article{KrauseSchuppeSaureetal.1988, author = {Krause, Gregor and Schuppe, W.D. and Saure, M. and Andress, H.}, title = {Sensitive Analytical and Physical Methods for Diagnosis of Variations in Polyolefin Plaques and Cable Insulations / W.D. Schuppe, M. Saure, H. Andress, K. M{\"o}ller, D. Meurer, G. Krause}, series = {Proceedings of the 32nd session : 28th August - 3rd September.}, journal = {Proceedings of the 32nd session : 28th August - 3rd September.}, year = {1988}, language = {en} } @article{AchtsnichtNeuendorfFassbenderetal.2019, author = {Achtsnicht, Stefan and Neuendorf, Christian and Faßbender, Tobias and N{\"o}lke, Greta and Offenh{\"a}usser, Andreas and Krause, Hans-Joachim and Schr{\"o}per, Florian}, title = {Sensitive and rapid detection of cholera toxin subunit B using magnetic frequency mixing detection}, series = {Plos One}, volume = {14}, journal = {Plos One}, number = {7}, publisher = {Plos}, address = {San Francisco}, issn = {1932-6203}, doi = {10.1371/journal.pone.0219356}, pages = {e0219356}, year = {2019}, abstract = {Cholera is a life-threatening disease caused by the cholera toxin (CT) as produced by some Vibrio cholerae serogroups. In this research we present a method which directly detects the toxin's B subunit (CTB) in drinking water. For this purpose we performed a magnetic sandwich immunoassay inside a 3D immunofiltration column. We used two different commercially available antibodies to capture CTB and for binding to superparamagnetic beads. ELISA experiments were performed to select the antibody combination. The beads act as labels for the magnetic frequency mixing detection technique. We show that the limit of detection depends on the type of magnetic beads. A nonlinear Hill curve was fitted to the calibration measurements by means of a custom-written python software. We achieved a sensitive and rapid detection of CTB within a broad concentration range from 0.2 ng/ml to more than 700 ng/ml.}, language = {en} }