@inproceedings{FrotscherGossmannTemizArtmannetal.2013, author = {Frotscher, Ralf and Goßmann, Matthias and Temiz Artmann, Ayseg{\"u}l and Staat, Manfred}, title = {Simulation of cardiac cell-seeded membranes using the edge-based smoothed FEM}, series = {1st International Conference "Shell and Membrane Theories in Mechanics and Biology: From Macro- to Nanoscale Structures", Minsk, Belarus, Sept. 16-20, 2013}, booktitle = {1st International Conference "Shell and Membrane Theories in Mechanics and Biology: From Macro- to Nanoscale Structures", Minsk, Belarus, Sept. 16-20, 2013}, publisher = {Verl. d. Weißruss. Staatl. Univ.}, address = {Minsk}, organization = {International Conference Shell and Membrane Theories in Mechanics and Biology: From Macro- to Nanoscale Structures <1, 2013, Minsk>}, isbn = {978-985-553-135-8}, pages = {165 -- 167}, year = {2013}, language = {en} } @inproceedings{BehbahaniRibleMoulinecetal.2015, author = {Behbahani, Mehdi and Rible, Sebastian and Moulinec, Charles and Fournier, Yvan and Nicolai, Mike and Crosetto, Paolo}, title = {Simulation of the FDA Centrifugal Blood Pump Using High Performance Computing}, series = {World Academy of Science, Engineering and Technology International Journal of Mechanical and Mechatronics Engineering}, volume = {9}, booktitle = {World Academy of Science, Engineering and Technology International Journal of Mechanical and Mechatronics Engineering}, number = {5}, year = {2015}, language = {en} } @inproceedings{StreunAlKaddoumParletal.2012, author = {Streun, M. and Al-Kaddoum, R. and Parl, C. and Pietrzyk, U. and Ziemons, Karl and Waasen, S. van}, title = {Simulation studies of optical photons in monolithic block scintillators}, series = {2011 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, booktitle = {2011 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, publisher = {IEEE}, address = {New York}, isbn = {978-1-4673-0120-6 (electronic ISBN)}, doi = {10.1109/NSSMIC.2011.6154621}, pages = {1380 -- 1382}, year = {2012}, abstract = {The interest in PET detectors with monolithic block scintillators is growing. In order to obtain high spatial resolutions dedicated positioning algorithms are required. But even an ideal algorithm can only deliver information which is provided by the detector. In this simulation study we investigated the light distribution on one surface of cuboid LSO scintillators of different size. Scintillators with a large aspect ratio (small footprint and large height) showed significant position information only for a minimum interaction depth of the gamma particle. The results allow a quantitative estimate for a useful aspect ratio.}, language = {en} } @inproceedings{OlderogMohrBegingetal.2021, author = {Olderog, M. and Mohr, P. and Beging, Stefan and Tsoumpas, C. and Ziemons, Karl}, title = {Simulation study on the role of tissue-scattered events in improving sensitivity for a compact time of flight compton positron emission tomograph}, series = {2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)}, booktitle = {2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)}, publisher = {IEEE}, isbn = {978-1-7281-7693-2}, doi = {10.1109/NSS/MIC42677.2020.9507901}, pages = {4 Seiten}, year = {2021}, abstract = {In positron emission tomography improving time, energy and spatial detector resolutions and using Compton kinematics introduces the possibility to reconstruct a radioactivity distribution image from scatter coincidences, thereby enhancing image quality. The number of single scattered coincidences alone is in the same order of magnitude as true coincidences. In this work, a compact Compton camera module based on monolithic scintillation material is investigated as a detector ring module. The detector interactions are simulated with Monte Carlo package GATE. The scattering angle inside the tissue is derived from the energy of the scattered photon, which results in a set of possible scattering trajectories or broken line of response. The Compton kinematics collimation reduces the number of solutions. Additionally, the time of flight information helps localize the position of the annihilation. One of the questions of this investigation is related to how the energy, spatial and temporal resolutions help confine the possible annihilation volume. A comparison of currently technically feasible detector resolutions (under laboratory conditions) demonstrates the influence on this annihilation volume and shows that energy and coincidence time resolution have a significant impact. An enhancement of the latter from 400 ps to 100 ps leads to a smaller annihilation volume of around 50\%, while a change of the energy resolution in the absorber layer from 12\% to 4.5\% results in a reduction of 60\%. The inclusion of single tissue-scattered data has the potential to increase the sensitivity of a scanner by a factor of 2 to 3 times. The concept can be further optimized and extended for multiple scatter coincidences and subsequently validated by a reconstruction algorithm.}, language = {en} } @inproceedings{KolditzAlbinFasseetal.2015, author = {Kolditz, Melanie and Albin, Thivaharan and Fasse, Alessandro and Br{\"u}ggemann, Gert-Peter and Abel, Dirk and Albracht, Kirsten}, title = {Simulative Analysis of Joint Loading During Leg Press Exercise for Control Applications}, series = {IFAC-PapersOnLine}, volume = {48}, booktitle = {IFAC-PapersOnLine}, number = {20}, doi = {10.1016/j.ifacol.2015.10.179}, pages = {435 -- 440}, year = {2015}, language = {en} } @inproceedings{StaatDuong2016, author = {Staat, Manfred and Duong, Minh Tuan}, title = {Smoothed Finite Element Methods for Nonlinear Solid Mechanics Problems: 2D and 3D Case Studies}, series = {Proceedings of the National Science and Technology Conference on Mechanical - Transportation Engineering (NSCMET 2016), 13th October 2016, Hanoi, Vietnam, Vol.2}, booktitle = {Proceedings of the National Science and Technology Conference on Mechanical - Transportation Engineering (NSCMET 2016), 13th October 2016, Hanoi, Vietnam, Vol.2}, pages = {440 -- 445}, year = {2016}, abstract = {The Smoothed Finite Element Method (SFEM) is presented as an edge-based and a facebased techniques for 2D and 3D boundary value problems, respectively. SFEMs avoid shortcomings of the standard Finite Element Method (FEM) with lower order elements such as overly stiff behavior, poor stress solution, and locking effects. Based on the idea of averaging spatially the standard strain field of the FEM over so-called smoothing domains SFEM calculates the stiffness matrix for the same number of degrees of freedom (DOFs) as those of the FEM. However, the SFEMs significantly improve accuracy and convergence even for distorted meshes and/or nearly incompressible materials. Numerical results of the SFEMs for a cardiac tissue membrane (thin plate inflation) and an artery (tension of 3D tube) show clearly their advantageous properties in improving accuracy particularly for the distorted meshes and avoiding shear locking effects.}, language = {en} } @inproceedings{SchreiberHirtbachKraftetal.2013, author = {Schreiber, Marc and Hirtbach, Stefan and Kraft, Bodo and Steinmetzler, Andreas}, title = {Software in the city: visual guidance through large scale software projects}, series = {Software Engineering 2013 : Fachtagung des GI-Fachbereichs Softwaretechnik, 26. Februar-1. M{\"a}rz 2013 in Aachen. (GI-Edition ; 213)}, booktitle = {Software Engineering 2013 : Fachtagung des GI-Fachbereichs Softwaretechnik, 26. Februar-1. M{\"a}rz 2013 in Aachen. (GI-Edition ; 213)}, editor = {Kowalewski, Stefan}, publisher = {Ges. f{\"u}r Informatik}, address = {Bonn}, isbn = {978-3-88579-607-7 ; 978-3-88579-609-1}, pages = {213 -- 224}, year = {2013}, language = {en} } @inproceedings{DigelTemizArtmannNojimaetal.2003, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Nojima, H. and Artmann, Gerhard}, title = {Some peculiarities of application of cluster ions generated by plasma in respect of indoor air purification :[abstract]}, year = {2003}, abstract = {Recently, the SHARP Corporation, Japan, has developed the world's first "Plasma Cluster Ions (PCI)" air purification technology using plasma discharge to generate cluster ions. The new plasma cluster device releases positive and negative ions into the air, which are able to decompose and deactivate harmful airborne substances by chemical reactions. Because cluster ions consist of positive and negative ions that normally exist in the natural world, they are completely harmless and safe to humans. The amount of ozone generated by cluster ions is less than 0.01 ppm, which is significantly less than the 0.05-ppm standard for industrial operations and consumer electronics. This amount, thus, has no harming effects whatsoever on the human body. But particular properties and chemical processes in PCI treatment are still under study. It has been shown that PCI in most cases show strongly pronounced irreversible killing effects in respect of airborne microflora due to free-radical induced reactions and can be considered as a potent technology to disinfect both home, medical and industrial appliances.}, subject = {Clusterion}, language = {en} } @inproceedings{KohlSchmidtsKloeseretal.2021, author = {Kohl, Philipp and Schmidts, Oliver and Kl{\"o}ser, Lars and Werth, Henri and Kraft, Bodo and Z{\"u}ndorf, Albert}, title = {STAMP 4 NLP - an agile framework for rapid quality-driven NLP applications development}, series = {Quality of Information and Communications Technology. QUATIC 2021}, booktitle = {Quality of Information and Communications Technology. QUATIC 2021}, publisher = {Springer}, address = {Cham}, isbn = {978-3-030-85346-4}, doi = {10.1007/978-3-030-85347-1_12}, pages = {156 -- 166}, year = {2021}, abstract = {The progress in natural language processing (NLP) research over the last years, offers novel business opportunities for companies, as automated user interaction or improved data analysis. Building sophisticated NLP applications requires dealing with modern machine learning (ML) technologies, which impedes enterprises from establishing successful NLP projects. Our experience in applied NLP research projects shows that the continuous integration of research prototypes in production-like environments with quality assurance builds trust in the software and shows convenience and usefulness regarding the business goal. We introduce STAMP 4 NLP as an iterative and incremental process model for developing NLP applications. With STAMP 4 NLP, we merge software engineering principles with best practices from data science. Instantiating our process model allows efficiently creating prototypes by utilizing templates, conventions, and implementations, enabling developers and data scientists to focus on the business goals. Due to our iterative-incremental approach, businesses can deploy an enhanced version of the prototype to their software environment after every iteration, maximizing potential business value and trust early and avoiding the cost of successful yet never deployed experiments.}, language = {en} } @inproceedings{StaatTran2022, author = {Staat, Manfred and Tran, Ngoc Trinh}, title = {Strain based brittle failure criteria for rocks}, series = {Proceedings of (NACOME2022) The 11th National Conference on Mechanics, Vol. 1. Solid Mechanics, Rock Mechanics, Artificial Intelligence, Teaching and Training, Hanoi, December 2-3, 2022}, booktitle = {Proceedings of (NACOME2022) The 11th National Conference on Mechanics, Vol. 1. Solid Mechanics, Rock Mechanics, Artificial Intelligence, Teaching and Training, Hanoi, December 2-3, 2022}, publisher = {Nha xuat ban Khoa hoc tu nhien va Cong nghe (Verlag Naturwissenschaft und Technik)}, address = {Hanoi}, isbn = {978-604-357-084-7}, pages = {500 -- 509}, year = {2022}, abstract = {When confining pressure is low or absent, extensional fractures are typical, with fractures occurring on unloaded planes in rock. These "paradox" fractures can be explained by a phenomenological extension strain failure criterion. In the past, a simple empirical criterion for fracture initiation in brittle rock has been developed. But this criterion makes unrealistic strength predictions in biaxial compression and tension. A new extension strain criterion overcomes this limitation by adding a weighted principal shear component. The weight is chosen, such that the enriched extension strain criterion represents the same failure surface as the Mohr-Coulomb (MC) criterion. Thus, the MC criterion has been derived as an extension strain criterion predicting failure modes, which are unexpected in the understanding of the failure of cohesive-frictional materials. In progressive damage of rock, the most likely fracture direction is orthogonal to the maximum extension strain. The enriched extension strain criterion is proposed as a threshold surface for crack initiation CI and crack damage CD and as a failure surface at peak P. Examples show that the enriched extension strain criterion predicts much lower volumes of damaged rock mass compared to the simple extension strain criterion.}, language = {en} } @inproceedings{MuellerVeggianNeskakisLiederetal.1978, author = {M{\"u}ller-Veggian, Mattea and Neskakis, A. and Lieder, R. M. and Beuscher, H.}, title = {Study of rotational aligned bands in ¹⁹⁰,¹⁹²,¹⁹⁴ Au}, series = {Nuclear interactions : International Conference on Nuclear Interactions held in Canberra, 28 Aug. - 1 Sept. 1978 / ed. by Brian Albert Robson. - (Lecture notes in physics ; 92)}, booktitle = {Nuclear interactions : International Conference on Nuclear Interactions held in Canberra, 28 Aug. - 1 Sept. 1978 / ed. by Brian Albert Robson. - (Lecture notes in physics ; 92)}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-540-09102-8}, pages = {428}, year = {1978}, language = {en} } @inproceedings{SrivastavaSinghDhandetal.2006, author = {Srivastava, Alok and Singh, Virendra and Dhand, Chetna and Kaur, Manindar and Singh, Tejvir and Witte, Katrin and Scherer, Ulrich W.}, title = {Study of swift heavy ion modified conduction polymer composites for application as gas sensor}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1345}, year = {2006}, abstract = {A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas.}, subject = {Biosensor}, language = {en} } @inproceedings{WeldenSeverinsPoghossianetal.2022, author = {Welden, Melanie and Severins, Robin and Poghossian, Arshak and Wege, Christina and Siegert, Petra and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Studying the immobilization of acetoin reductase with Tobacco mosaic virus particles on capacitive field-effect sensors}, series = {2022 IEEE International Symposium on Olfaction and Electronic Nose (ISOEN)}, booktitle = {2022 IEEE International Symposium on Olfaction and Electronic Nose (ISOEN)}, publisher = {IEEE}, isbn = {978-1-6654-5860-3 (Online)}, doi = {10.1109/ISOEN54820.2022.9789657}, pages = {4 Seiten}, year = {2022}, abstract = {A capacitive electrolyte-insulator-semiconductor (EISCAP) biosensor modified with Tobacco mosaic virus (TMV) particles for the detection of acetoin is presented. The enzyme acetoin reductase (AR) was immobilized on the surface of the EISCAP using TMV particles as nanoscaffolds. The study focused on the optimization of the TMV-assisted AR immobilization on the Ta 2 O 5 -gate EISCAP surface. The TMV-assisted acetoin EISCAPs were electrochemically characterized by means of leakage-current, capacitance-voltage, and constant-capacitance measurements. The TMV-modified transducer surface was studied via scanning electron microscopy.}, language = {en} } @inproceedings{KraftNagl2003, author = {Kraft, Bodo and Nagl, Manfred}, title = {Support of Conceptual Design in Civil Engineering by Graph-based Tools}, year = {2003}, abstract = {WS GTaD-2003 - The 1st Workshop on Graph Transformations and Design ed Grabska, E., Seite 6-7, Jagiellonian University Krakow. 2 pages}, subject = {CAD}, language = {de} } @inproceedings{PijanowskaRemiszewskaPederzollietal.2006, author = {Pijanowska, Dorota G. and Remiszewska, Elzbieta and Pederzolli, Cecilia and Lunelli, Lorenzo and Vendano, Michele and Canteri, Roberto and Dudzinski, Konrad and Kruk, Jerzy and Torbicz, Wladyslaw}, title = {Surface modification for microreactor fabrication}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1480}, year = {2006}, abstract = {In this paper, methods of surface modification of different supports, i.e. glass and polymeric beads for enzyme immobilisation are described. The developed method of enzyme immobilisation is based on Schiff's base formation between the amino groups on the enzyme surface and the aldehyde groups on the chemically modified surface of the supports. The surface of silicon modified by APTS and GOPS with immobilised enzyme was characterised by atomic force microscopy (AFM), time-of-flight secondary ion mass spectroscopy (ToF-SIMS) and infrared spectroscopy (FTIR). The supports with immobilised enzyme (urease) were also tested in combination with microreactors fabricated in silicon and Perspex, operating in a flow-through system. For microreactors filled with urease immobilised on glass beads (Sigma) and on polymeric beads (PAN), a very high and stable signal (pH change) was obtained. The developed method of urease immobilisation can be stated to be very effective.}, subject = {Biosensor}, language = {en} } @inproceedings{KreyerStollenwerkSchoening2013, author = {Kreyer, J{\"o}rg and Stollenwerk, Dominik and Sch{\"o}ning, Michael Josef}, title = {Tagung des Forschernachwuchses der FH Aachen 20. November 2013 / ed.: J. Kreyer, D. Stollenwerk, M. J. Sch{\"o}ning}, publisher = {FH Aachen}, address = {Aachen}, pages = {64 S.}, year = {2013}, language = {de} } @inproceedings{StadlerEmbsZerlinetal.2007, author = {Stadler, Andreas M. and Embs, Jan P. and Zerlin, Kay and Digel, Ilya and Artmann, Gerhard and Zaccai, Joe and B{\"u}ldt, Georg}, title = {Temperature transitions of hemoglobin and cytosolic water diffusion in human red blood cells : [poster]}, year = {2007}, abstract = {Background Hemoglobin interactions in red blood cells Hemoglobin dynamics in human red blood cells Diffusion of H2O in red blood cells}, subject = {Erythrozyt}, language = {en} } @inproceedings{ArtmannStadlerEmbsetal.2010, author = {Artmann, Gerhard and Stadler, Andreas M. and Embs, Jan P. and Zaccai, Giuseppe and B{\"u}ldt, Georg and Digel, Ilya and Temiz Artmann, Ayseg{\"u}l}, title = {The crucial role of water in a phase transition of hemoglobin at body temperature : [abstract]}, year = {2010}, abstract = {The observation of a temperature transition of hemoglobin occurring at a critical temperature close to body temperature}, subject = {H{\"a}moglobin}, language = {en} } @inproceedings{WeberTersteggeHallingetal.1995, author = {Weber, S. and Terstegge, Andreas and Halling, H. and Herzog, H. and Reinartz, R. and Reinhart, P. and Rongen, F. and M{\"u}ller-G{\"a}rtner, H.-W.}, title = {The design of an animal PET: flexible geometry for achieving optimal spatial resolution or high sensitivity}, series = {Conference record / 1995 IEEE Nuclear Science Symposium and Medical Imaging, October 21 - 28, 1995, San Francisco ; vol. 2}, booktitle = {Conference record / 1995 IEEE Nuclear Science Symposium and Medical Imaging, October 21 - 28, 1995, San Francisco ; vol. 2}, publisher = {IEEE}, address = {Piscataway, NJ}, organization = {Institute of Electrical and Electronics Engineers}, isbn = {078033180X ; 0780331818 ; 0780331826}, pages = {1002 -- 1005}, year = {1995}, language = {en} } @inproceedings{WeberTersteggeEngelsetal.1996, author = {Weber, S. and Terstegge, Andreas and Engels, R. and Herzog, H. and Reinartz, R. and Reinhart, P. and Rongen, F. and M{\"u}ller-G{\"a}rtner, H. W. and Halling, H.}, title = {The KFA TierPET: performance characteristics and measurements}, series = {Conference record / 1996 IEEE Nuclear Science Symposium [and Medical Imaging], November 2 - 9, 1996, Anaheim, California ; vol. 2}, booktitle = {Conference record / 1996 IEEE Nuclear Science Symposium [and Medical Imaging], November 2 - 9, 1996, Anaheim, California ; vol. 2}, publisher = {IEEE}, address = {Piscataway, NJ}, organization = {Institute of Electrical and Electronics Engineers}, isbn = {0-7803-3534-1}, issn = {1082-3654}, pages = {1117 -- 1119}, year = {1996}, language = {en} }