@inproceedings{Gebhardt2006, author = {Gebhardt, Andreas}, title = {Technology Diffusion through a Multi-Level Technology Transfer Infrastructure. Contribution to the 1st. All Africa Technology Diffusion Conference Boksburg, South Africa June 12th - 14th 2006}, year = {2006}, abstract = {Table of contents 1. Introduction 2. Multi-level Technology Transfer Infrastructure 2.1 Level 1: University Education - Encourage the Idea of becoming an Entrepreneur 2.2 Level 2: Post Graduate Education - Improve your skills and focus it on a product family. 2.3 Level 3: Birth of a Company - Focus your skills on a product and a market segment. 2.4 Level 4: Ready to stand alone - Set up your own business 2.5 Level 5: Grow to be Strong - Develop your business 2.6 Level 6: Competitive and independent - Stay innovative. 3. Samples 3.1 Sample 1: Laser Processing and Consulting Centre, LBBZ 3.2 Sample 2: Prototyping Centre, CP 4. Funding - Waste money or even lost Money? 5. Conclusion}, subject = {Technologietransfer}, language = {en} } @inproceedings{TranStaatKreissig2007, author = {Tran, Thanh Ngoc and Staat, Manfred and Kreißig, R.}, title = {Calculation of load carrying capacity of shell structures with elasto-plastic material by direct methods}, year = {2007}, abstract = {Proceedings of the International Conference on Material Theory and Nonlinear Dynamics. MatDyn. Hanoi, Vietnam, Sept. 24-26, 2007, 8 p. In this paper, a method is introduced to determine the limit load of general shells using the finite element method. The method is based on an upper bound limit and shakedown analysis with elastic-perfectly plastic material model. A non-linear constrained optimisation problem is solved by using Newton's method in conjunction with a penalty method and the Lagrangean dual method. Numerical investigation of a pipe bend subjected to bending moments proves the effectiveness of the algorithm.}, subject = {Finite-Elemente-Methode}, language = {en} } @inproceedings{FredebeulKrein2007, author = {Fredebeul-Krein, Markus}, title = {10 years of liberalised telecom markets in Germany: Assessing the degree of competition on the markets for voice telephony}, year = {2007}, abstract = {Market data for the German telecom market shows that Deutsche Telekom as the former incumbent is constantly loosing shares on all arkets for voice telephony: the market for local calls, the market for long-distance calls and the market for international calls. At the same time prices decline steadily with the latest trend being that operators offer voice services free of charge, the costs of which are covered by a monthly subscription charge. Against this background the paper examines the state of policy and regulatory reform in the telecommunications sector in Germany almost 10 years after the liberalisation of the fixed telecommunications market. Thereby the focus is on the analysis of the competitive conditions that have been established on the German market for voice telephony services. If these retail markets are competitive, there might be a need to remove remaining regulatory provisions. In the new environment of converging markets the future challenge of regulating fixed telecom markets might be to ensure that access to the network and/or services of a potentially dominant provider in a relevant market will satisfy requirements for openness and non-discrimination.}, subject = {Telekommunikationsmarkt}, language = {en} } @inproceedings{FredebeulKrein2007, author = {Fredebeul-Krein, Markus}, title = {10 Jahre Wettbewerb auf dem deutschen Telekommunikationsmarkt: Zeit f{\"u}r einen Paradigmenwechsel in der Regulierung?}, year = {2007}, abstract = {1. Ein Referenzrahmen f{\"u}r die Wettbewerbsanalyse 2. Regulierung des deutschen Marktes f{\"u}r Sprachtelefondienste 3. Wettbewerb auf dem deutschen Markt f{\"u}r Sprachtelefondienste 4. Die Telekommunikationsregulierung vor einem Paradigmenwechsel}, subject = {Telekommunikationsmarkt}, language = {de} } @inproceedings{TranStaatKreissig2007, author = {Tran, Thanh Ngoc and Staat, Manfred and Kreißig, R.}, title = {Finite element shakedown and limit reliability analysis of thin shells}, year = {2007}, abstract = {A procedure for the evaluation of the failure probability of elastic-plastic thin shell structures is presented. The procedure involves a deterministic limit and shakedown analysis for each probabilistic iteration which is based on the kinematical approach and the use the exact Ilyushin yield surface. Based on a direct definition of the limit state function, the non-linear problems may be efficiently solved by using the First and Second Order Reliabiblity Methods (Form/SORM). This direct approach reduces considerably the necessary knowledge of uncertain technological input data, computing costs and the numerical error. In: Computational plasticity / ed. by Eugenio Onate. Dordrecht: Springer 2007. VII, 265 S. (Computational Methods in Applied Sciences ; 7) (COMPLAS IX. Part 1 . International Center for Numerical Methods in Engineering (CIMNE)). ISBN 978-1-402-06576-7 S. 186-189}, subject = {Finite-Elemente-Methode}, language = {en} } @inproceedings{SrivastavaSinghDhandetal.2006, author = {Srivastava, Alok and Singh, Virendra and Dhand, Chetna and Kaur, Manindar and Singh, Tejvir and Witte, Katrin and Scherer, Ulrich W.}, title = {Study of swift heavy ion modified conduction polymer composites for application as gas sensor}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1345}, year = {2006}, abstract = {A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas.}, subject = {Biosensor}, language = {en} } @inproceedings{ChaiybounTrauteKiesewetteretal.2006, author = {Chaiyboun, Ali and Traute, R{\"u}diger and Kiesewetter, Olaf and Ahlers, Simon and M{\"u}ller, Gerhard and Doll, Theodor}, title = {Modular analytical multicomponent analysis in gas sensor arrays}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1358}, year = {2006}, abstract = {A multi-sensor system is a chemical sensor system which quantitatively and qualitatively records gases with a combination of cross-sensitive gas sensor arrays and pattern recognition software. This paper addresses the issue of data analysis for identification of gases in a gas sensor array. We introduce a software tool for gas sensor array configuration and simulation. It concerns thereby about a modular software package for the acquisition of data of different sensors. A signal evaluation algorithm referred to as matrix method was used specifically for the software tool. This matrix method computes the gas concentrations from the signals of a sensor array. The software tool was used for the simulation of an array of five sensors to determine gas concentration of CH4, NH3, H2, CO and C2H5OH. The results of the present simulated sensor array indicate that the software tool is capable of the following: (a) identify a gas independently of its concentration; (b) estimate the concentration of the gas, even if the system was not previously exposed to this concentration; (c) tell when a gas concentration exceeds a certain value. A gas sensor data base was build for the configuration of the software. With the data base one can create, generate and manage scenarios and source files for the simulation. With the gas sensor data base and the simulation software an on-line Web-based version was developed, with which the user can configure and simulate sensor arrays on-line.}, subject = {Biosensor}, language = {en} } @inproceedings{SakthivelWeppner2006, author = {Sakthivel, Mariappan and Weppner, Werner}, title = {Response behaviour of a hydrogen sensor based on ionic conducting polymer-metal interfaces prepared by the chemical reduction method}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1399}, year = {2006}, abstract = {A solid-state amperometric hydrogen sensor based on a protonated Nafion membrane and catalytic active electrode operating at room temperature was fabricated and tested. Ionic conducting polymer-metal electrode interfaces were prepared chemically by using the impregnation-reduction method. The polymer membrane was impregnated with tetra-ammine platinum chloride hydrate and the metal ions were subsequently reduced by using either sodium tetrahydroborate or potassium tetrahydroborate. The hydrogen sensing characteristics with air as reference gas is reported. The sensors were capable of detecting hydrogen concentrations from 10 ppm to 10\% in nitrogen. The response time was in the range of 10-30 s and a stable linear current output was observed. The thin Pt films were characterized by XRD, Infrared Spectroscopy, Optical Microscopy, Atomic Force Microscopy, Scanning Electron Microscopy and EDAX.}, subject = {Biosensor}, language = {en} } @inproceedings{KoplinSiemonsOcenValentinetal.2006, author = {Koplin, Tobias J. and Siemons, Maike and Oc{\´e}n-Val{\´e}ntin, C{\´e}sar and Sanders, Daniel and Simon, Ulrich}, title = {Workflow for high throughput screening of gas sensing materials}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1407}, year = {2006}, abstract = {The workflow of a high throughput screening setup for the rapid identification of new and improved sensor materials is presented. The polyol method was applied to prepare nanoparticular metal oxides as base materials, which were functionalised by surface doping. Using multi-electrode substrates and high throughput impedance spectroscopy (HT-IS) a wide range of materials could be screened in a short time. Applying HT-IS in search of new selective gas sensing materials a NO2-tolerant NO sensing material with reduced sensitivities towards other test gases was identified based on iridium doped zinc oxide. Analogous behaviour was observed for iridium doped indium oxide.}, subject = {Biosensor}, language = {en} } @inproceedings{NaetherJuarezEmmerichetal.2006, author = {N{\"a}ther, Niko and Ju{\´a}rez, Leon M. and Emmerich, R{\"u}diger and Berger, J{\"o}rg and Friedrich, Peter and Sch{\"o}ning, Michael Josef}, title = {Detection of hydrogen peroxide (H2O2) at exposed temperatures for industrial processes}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1418}, year = {2006}, abstract = {An H2O2 sensor for the application in industrial sterilisation processes has been developed. Therefore, automated sterilisation equipment at laboratory scale has been constructed using parts from industrial sterilisation facilities. In addition, a software tool has been developed for the control of the sterilisation equipment at laboratory scale. First measurements with the developed sensor set-up as part of the sterilisation equipment have been performed and the sensor has been physically characterised by optical microscopy and SEM.}, subject = {Biosensor}, language = {en} } @inproceedings{WagnerKohlFroebaetal.2006, author = {Wagner, Thorsten and Kohl, Claus-Dieter and Fr{\"o}ba, Michael and Tiemann, Michael}, title = {Gas sensing properties of ordered mesoporous SnO2}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1422}, year = {2006}, abstract = {We report on the synthesis and CO gas-sensing properties of mesoporous tin(IV) oxides (SnO2). For the synthesis cetyltrimethylammonium bromide (CTABr) was used as a structure-directing agent; the resulting SnO2 powders were applied as films to commercially available sensor substrates by drop coating. Nitrogen physisorption shows specific surface areas up to 160 m2·g-1 and mean pore diameters of about 4 nm, as verified by TEM. The film conductance was measured in dependence on the CO concentration in humid synthetic air at a constant temperature of 300 °C. The sensors show a high sensitivity at low CO concentrations and turn out to be largely insensitive towards changes in the relative humidity. We compare the materials with commercially available SnO2-based sensors.}, subject = {Biosensor}, language = {en} } @inproceedings{MirmohseniRostamizadeh2006, author = {Mirmohseni, Abdolreza and Rostamizadeh, Kobra}, title = {Quartz crystal nanobalance in conjunction with principal component analysis for identification of volatile organic compounds}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1434}, year = {2006}, abstract = {Quartz crystal nanobalance (QCN) sensors are considered as powerful masssensitive sensors to determine materials in the sub-nanogram level. In this study, a single piezoelectric quartz crystal nanobalance modified with polystyrene was employed to detect benzene, toluene, ethylbenzene and xylene (BTEX compounds). The frequency shift of the QCN sensor was found to be linear against the BTEX compound concentrations in the range about 1-45 mg l-1. The correlation coefficients for benzene, toluene, ethylbenzene, and xylene were 0.991, 0.9977, 0.9946 and 0.9971, respectively. The principal component analysis was also utilized to process the frequency response data of the single piezoelectric crystal at different times, considering to the different adsorption-desorption dynamics of BTEX compounds. Using principal component analysis, it was found that over 90\% of the data variance could still be explained by use of two principal components (PC1 and PC2). Subsequently, the successful identification of benzene and toluene was possible through the principal component analysis of the transient responses of the polystyrene modified QCN sensor. The results showed that the polystyrene-modified QCN had favorable identification and quantification performances for the BTEX compounds.}, subject = {Biosensor}, language = {en} } @inproceedings{KreutzLoergenGraeweetal.2006, author = {Kreutz, Christian and L{\"o}rgen, J{\"u}rgen and Graewe, Boris and Bargon, Joachim and Yoshida, Mayumi and Freso, Zachary M. and Fr{\`e}chet, Jean M. J.}, title = {High frequency quartz micro balances: a promising path to enhanced sensitivity of gravimetric sensors}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1445}, year = {2006}, abstract = {An array of 50 MHz quartz microbalances (QMBs) coated with a dendronized polymer was used to detect small amounts of volatile organic compounds (VOCs) in the gas phase. The results were compared to those obtained with the commonly used 10 MHz QMBs. The 50 MHz QMBs proved to be a powerful tool for the detection of VOCs in the gas phase; therefore, they represent a promising alternative to the much more delicate surface acoustic wave devices (SAWs).}, subject = {Biosensor}, language = {en} } @inproceedings{RabnerShacham2006, author = {Rabner, Arthur and Shacham, Yosi}, title = {A concept for a sensitive micro total analysis system for high throughput fluorescence imaging}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1456}, year = {2006}, abstract = {This paper discusses possible methods for on-chip fluorescent imaging for integrated bio-sensors. The integration of optical and electro-optical accessories, according to suggested methods, can improve the performance of fluorescence imaging. It can boost the signal to background ratio by a few orders of magnitudes in comparison to conventional discrete setups. The methods that are present in this paper are oriented towards building reproducible arrays for high-throughput micro total analysis systems (µTAS). The first method relates to side illumination of the fluorescent material placed into microcompartments of the lab-on-chip. Its significance is in high utilization of excitation energy for low concentration of fluorescent material. The utilization of a transparent µLED chip, for the second method, allows the placement of the excitation light sources on the same optical axis with emission detector, such that the excitation and emission rays are directed controversly. The third method presents a spatial filtering of the excitation background.}, subject = {Biosensor}, language = {en} } @inproceedings{FoersterStockMontanarietal.2006, author = {F{\"o}rster, Arnold and Stock, J{\"u}rgen and Montanari, Simone and Lepsa, Mihail Ion and L{\"u}th, Hans}, title = {Fabrication and characterisation of GaAs Gunn Diode Chips for applications at 77 GHz in automotive industry}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1462}, year = {2006}, abstract = {GaAs-based Gunn diodes with graded AlGaAs hot electron injector heterostructures have been developed under the special needs in automotive applications. The fabrication of the Gunn diode chips was based on total substrate removal and processing of integrated Au heat sinks. Especially, the thermal and RF behavior of the diodes have been analyzed by DC, impedance and S-parameter measurements. The electrical investigations have revealed the functionality of the hot electron injector. An optimized layer structure could fulfill the requirements in adaptive cruise control (ACC) systems at 77 GHz with typical output power between 50 and 90 mW.}, subject = {Biosensor}, language = {en} } @inproceedings{PlatenPoghossianSchoening2006, author = {Platen, Johannes and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Microstructured Nanostructures - nanostructuring by means of conventional photolithography and layer-expansion technique}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1477}, year = {2006}, abstract = {A new and simple method for nanostructuring using conventional photolithography and layer expansion or pattern-size reduction technique is presented, which can further be applied for the fabrication of different nanostructures and nano-devices. The method is based on the conversion of a photolithographically patterned metal layer to a metal-oxide mask with improved pattern-size resolution using thermal oxidation. With this technique, the pattern size can be scaled down to several nanometer dimensions. The proposed method is experimentally demonstrated by preparing nanostructures with different configurations and layouts, like circles, rectangles, trapezoids, "fluidic-channel"-, "cantilever"- and meander-type structures.}, subject = {Biosensor}, language = {en} } @inproceedings{PijanowskaRemiszewskaPederzollietal.2006, author = {Pijanowska, Dorota G. and Remiszewska, Elzbieta and Pederzolli, Cecilia and Lunelli, Lorenzo and Vendano, Michele and Canteri, Roberto and Dudzinski, Konrad and Kruk, Jerzy and Torbicz, Wladyslaw}, title = {Surface modification for microreactor fabrication}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1480}, year = {2006}, abstract = {In this paper, methods of surface modification of different supports, i.e. glass and polymeric beads for enzyme immobilisation are described. The developed method of enzyme immobilisation is based on Schiff's base formation between the amino groups on the enzyme surface and the aldehyde groups on the chemically modified surface of the supports. The surface of silicon modified by APTS and GOPS with immobilised enzyme was characterised by atomic force microscopy (AFM), time-of-flight secondary ion mass spectroscopy (ToF-SIMS) and infrared spectroscopy (FTIR). The supports with immobilised enzyme (urease) were also tested in combination with microreactors fabricated in silicon and Perspex, operating in a flow-through system. For microreactors filled with urease immobilised on glass beads (Sigma) and on polymeric beads (PAN), a very high and stable signal (pH change) was obtained. The developed method of urease immobilisation can be stated to be very effective.}, subject = {Biosensor}, language = {en} } @inproceedings{BukhariYang2006, author = {Bukhari, Syed Faisal Ahmed and Yang, Wuqiang}, title = {Multi-interface level sensors and new development in monitoring and control of oil separators}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1498}, year = {2006}, abstract = {In the oil industry, huge saving may be made if suitable multi-interface level measurement systems are employed for effectively monitoring crude oil separators and efficient control of their operation. A number of techniques, e.g. externally mounted displacers, differential pressure transmitters and capacitance rod devices, have been developed to measure the separation process with gas, oil, water and other components. Because of the unavailability of suitable multi-interface level measurement systems, oil separators are currently operated by the trial-and-error approach. In this paper some conventional techniques, which have been used for level measurement in industry, and new development are discussed.}, subject = {Biosensor}, language = {en} } @inproceedings{TymeckiGlabKoncki2006, author = {Tymecki, Lukasz and Glab, Stanislaw and Koncki, Robert}, title = {Miniaturized, planar ion-selective electrodes fabricated by means of thick-film technology}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1506}, year = {2006}, abstract = {Various planar technologies are employed for developing solid-state sensors having low cost, small size and high reproducibility; thin- and thick-film technologies are most suitable for such productions. Screen-printing is especially suitable due to its simplicity, low-cost, high reproducibility and efficiency in large-scale production. This technology enables the deposition of a thick layer and allows precise pattern control. Moreover, this is a highly economic technology, saving large amounts of the used inks. In the course of repetitions of the film-deposition procedure there is no waste of material due to additivity of this thick-film technology. Finally, the thick films can be easily and quickly deposited on inexpensive substrates. In this contribution, thick-film ion-selective electrodes based on ionophores as well as crystalline ion-selective materials dedicated for potentiometric measurements are demonstrated. Analytical parameters of these sensors are comparable with those reported for conventional potentiometric electrodes. All mentioned thick-film strip electrodes have been totally fabricated in only one, fully automated thickfilm technology, without any additional manual, chemical or electrochemical steps. In all cases simple, inexpensive, commercially available materials, i.e. flexible, plastic substrates and easily cured polymer-based pastes were used.}, subject = {Biosensor}, language = {en} } @inproceedings{SpannhakeSchulzHelwigetal.2006, author = {Spannhake, Jan and Schulz, Olaf and Helwig, Andreas and Krenkow, Angelika and M{\"u}ller, Gerhard and Doll, Theodor}, title = {High-temperature MEMS heater platforms: long-term performance of metal and semiconductor heater materials}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1513}, year = {2006}, abstract = {Micromachined thermal heater platforms offer low electrical power consumption and high modulation speed, i.e. properties which are advantageous for realizing nondispersive infrared (NDIR) gas- and liquid monitoring systems. In this paper, we report on investigations on silicon-on-insulator (SOI) based infrared (IR) emitter devices heated by employing different kinds of metallic and semiconductor heater materials. Our results clearly reveal the superior high-temperature performance of semiconductor over metallic heater materials. Long-term stable emitter operation in the vicinity of 1300 K could be attained using heavily antimony-doped tin dioxide (SnO2:Sb) heater elements.}, subject = {Biosensor}, language = {en} }