@incollection{HinkeVervierBrauneretal.2022, author = {Hinke, Christian and Vervier, Luisa and Brauner, Philipp and Schneider, Sebastian and Steuer-Dankert, Linda and Ziefle, Martina and Leicht-Scholten, Carmen}, title = {Capability configuration in next generation manufacturing}, series = {Forecasting next generation manufacturing : digital shadows, human-machine collaboration, and data-driven business models}, booktitle = {Forecasting next generation manufacturing : digital shadows, human-machine collaboration, and data-driven business models}, publisher = {Springer}, address = {Cham}, isbn = {978-3-031-07733-3}, doi = {10.1007/978-3-031-07734-0_6}, pages = {95 -- 106}, year = {2022}, abstract = {Industrial production systems are facing radical change in multiple dimensions. This change is caused by technological developments and the digital transformation of production, as well as the call for political and social change to facilitate a transformation toward sustainability. These changes affect both the capabilities of production systems and companies and the design of higher education and educational programs. Given the high uncertainty in the likelihood of occurrence and the technical, economic, and societal impacts of these concepts, we conducted a technology foresight study, in the form of a real-time Delphi analysis, to derive reliable future scenarios featuring the next generation of manufacturing systems. This chapter presents the capabilities dimension and describes each projection in detail, offering current case study examples and discussing related research, as well as implications for policy makers and firms. Specifically, we discuss the benefits of capturing expert knowledge and making it accessible to newcomers, especially in highly specialized industries. The experts argue that in order to cope with the challenges and circumstances of today's world, students must already during their education at university learn how to work with AI and other technologies. This means that study programs must change and that universities must adapt their structural aspects to meet the needs of the students.}, language = {en} } @article{HelsperFissan1983, author = {Helsper, Christoph and Fißan, H. J.}, title = {Calibration of the Polytec HC-15 and HC-70 Optical Particle Counters / Fißan, H. J. ; Helsper, C.}, series = {Aerosols in the mining and industrial work environments, Vol. 3. Instrumentation, Marple, Virgil A. ; Liu, Benjamin Y.}, journal = {Aerosols in the mining and industrial work environments, Vol. 3. Instrumentation, Marple, Virgil A. ; Liu, Benjamin Y.}, publisher = {Ann Arbor Science}, address = {Ann Arbor, Mich.}, pages = {825 -- 829}, year = {1983}, language = {en} } @article{HelsperFissanKasper1984, author = {Helsper, Christoph and Fißan, H. J. and Kasper, W.}, title = {Calibration of Optical Particle Counters with Respect to Particle Size / Fißan, H. J. ; Helsper, C.; Kasper, W.}, series = {Particle and Particle Systems Characterization. 1 (1984), H. 1984}, journal = {Particle and Particle Systems Characterization. 1 (1984), H. 1984}, isbn = {1521-4117}, pages = {108 -- 111}, year = {1984}, language = {en} } @inproceedings{KernBeierlZischank2009, author = {Kern, Alexander and Beierl, Ottmar and Zischank, Wolfgang}, title = {Calculation of the separation distance according to IEC 62305-3: 2006-10 - Remarks for the application and simplified methods}, year = {2009}, abstract = {[Paper of the X International Symposium on Lightning Protection 9th - 13th November, 2009 - Curitiba, Brazil. 6 pages] The international standard IEC 62305-3, published in 2006, requires as an integral part of the lightning protection system (LPS) the consideration of a separation distance between the conductors of the LPS and metal and electrical installations inside the structure to be protected. IEC 62305-3 gives two different methods for this calculation: a standard, simplified approach and a more detailed approach, which differ especially regarding the treatment of the current sharing effect on the LPS conductors. Hence, different results for the separation distance are possible, leading to some discrepancies in the use of the standard. The standard approach defined in the main part (Clause 6.3) and in Annex C of the standard in some cases may lead to a severe oversizing of the required separation distance. The detailed approach described in Annex E naturally gives more correct results. However, a calculation of the current sharing amongst all parts of the air-termination and downconductor network is necessary, in many cases requiring the use of network analysis programs. In this paper simplified methods for the assessment of the current sharing are presented, which are easy to use as well as sufficiently adequate.}, subject = {Blitzschutz}, language = {de} } @article{KernWiesingerZischank1991, author = {Kern, Alexander and Wiesinger, J. and Zischank, Wolfgang J.}, title = {Calculation of the longitudinal voltage along metal tubes caused by lightning currents and protection measures}, series = {Seventh International Symposium on High Voltage Engineering : Dresden, August 26 - 30 1991}, journal = {Seventh International Symposium on High Voltage Engineering : Dresden, August 26 - 30 1991}, publisher = {Techn. Univ.}, address = {Dresden}, year = {1991}, language = {en} } @inproceedings{PfundtVogelsangGerling1988, author = {Pfundt, H. and Vogelsang, D. and Gerling, Ulrich}, title = {Calculation of the crust profile in aluminium reduction cells by thermal computer modelling}, series = {Light metals 1989 : 118th annual meeting of the Minerals, Metals and Materials Society, Las Vegas, NV, Feb. 27 - Mar. 03. 1989}, booktitle = {Light metals 1989 : 118th annual meeting of the Minerals, Metals and Materials Society, Las Vegas, NV, Feb. 27 - Mar. 03. 1989}, publisher = {Minerals, Metals and Materials Soc.}, address = {Warrendale, Pa.}, pages = {371 -- 377}, year = {1988}, language = {en} } @inproceedings{KernSchelthoffMathieu2012, author = {Kern, Alexander and Schelthoff, Christof and Mathieu, Moritz}, title = {Calculation of interception efficiencies for mesh-type air-terminations according to IEC 62305-3 using a dynamic electro-geometrical model}, series = {International Conference on Lightning Protection (ICLP) : 2 - 7 Sept. 2012, Vienna}, booktitle = {International Conference on Lightning Protection (ICLP) : 2 - 7 Sept. 2012, Vienna}, publisher = {IEEE}, address = {Piscataway, NJ}, organization = {International Conference on Lightning Protection <2012, Wien>}, isbn = {978-1-4673-1896-9 (E-Book) ; 978-1-4673-1898-3 (Print)}, pages = {1 -- 6}, year = {2012}, language = {en} } @article{KernSchelthoffMathieu2011, author = {Kern, Alexander and Schelthoff, Christof and Mathieu, Moritz}, title = {Calculation of interception efficiencies for airterminations using a dynamic electro-geometrical model}, publisher = {IEEE}, address = {New York}, pages = {1 -- 6}, year = {2011}, language = {en} } @inproceedings{GorzalkaDahlkeGoettscheetal.2018, author = {Gorzalka, Philip and Dahlke, Dennis and G{\"o}ttsche, Joachim and Israel, Martin and Patel, Dhruvkumar and Prahl, Christoph and Schmiedt, Jacob Estevam and Frommholz, Dirk and Hoffschmidt, Bernhard and Linkiewicz, Magdalena}, title = {Building Tomograph-From Remote Sensing Data of Existing Buildings to Building Energy Simulation Input}, series = {EBC, Annex 71, Fifth expert meeting, October 17-19, 2018, Innsbruck, Austria}, booktitle = {EBC, Annex 71, Fifth expert meeting, October 17-19, 2018, Innsbruck, Austria}, pages = {17 Seiten}, year = {2018}, language = {en} } @inproceedings{SteuerDankertBergLeichtScholten2015, author = {Steuer-Dankert, Linda and Berg, Tobias and Leicht-Scholten, Carmen}, title = {Breaking the habit - new approaches in engineering education}, series = {Proceedings of the 43rd Annual Conference of the European Society for Engineering Education}, booktitle = {Proceedings of the 43rd Annual Conference of the European Society for Engineering Education}, isbn = {978-2-87352-012-0}, pages = {11}, year = {2015}, abstract = {Within the framework of the project a genderand diversity-oriented teaching evaluation and modern, media-supported blended learning approaches were used in order to achieve the intended goals. First research results of the literature and status quo analysis were already implemented and tested in newly designed teaching approaches, for example in a multidisciplinary introductory lecture of civil engineering at RWTH Aachen University.}, language = {en} } @inproceedings{EdipGarevskiButenwegetal.2014, author = {Edip, Kemal and Garevski, Mihail and Butenweg, Christoph and Sesov, Vlatko and Bojadjieva, Julijana and Gjorgjiev, Igor}, title = {Boundary effects on seismic analysis of multi-storey frames considering soil structure interaction phenomenon}, series = {Seismic design of industrial facilities : proceedings of the International Conference on Seismic Design of Industrial Facilities (SeDIF-Conference) ; [Aachen, 26. - 27. September 2013] / Chair of Structural Statics and Dynamics, RWTH Aachen. Sven Klinkel ..., ed}, booktitle = {Seismic design of industrial facilities : proceedings of the International Conference on Seismic Design of Industrial Facilities (SeDIF-Conference) ; [Aachen, 26. - 27. September 2013] / Chair of Structural Statics and Dynamics, RWTH Aachen. Sven Klinkel ..., ed}, publisher = {Springer Vieweg}, address = {Wiesbaden}, organization = {International Conference on Seismic Design of Industrial Facilities <2013, Aachen>}, isbn = {978-3-658-02809-1 (Print) ; 978-3-658-02810-7}, doi = {10.1007/978-3-658-02810-7_47}, pages = {569 -- 576}, year = {2014}, language = {en} } @article{HeelDiktaBraekers2021, author = {Heel, Mareike van and Dikta, Gerhard and Braekers, Roel}, title = {Bootstrap based goodness‑of‑fit tests for binary multivariate regression models}, series = {Journal of the Korean Statistical Society}, volume = {51}, journal = {Journal of the Korean Statistical Society}, publisher = {Springer Nature}, address = {Singapur}, issn = {2005-2863 (Online)}, doi = {10.1007/s42952-021-00142-4}, pages = {28 Seiten}, year = {2021}, abstract = {We consider a binary multivariate regression model where the conditional expectation of a binary variable given a higher-dimensional input variable belongs to a parametric family. Based on this, we introduce a model-based bootstrap (MBB) for higher-dimensional input variables. This test can be used to check whether a sequence of independent and identically distributed observations belongs to such a parametric family. The approach is based on the empirical residual process introduced by Stute (Ann Statist 25:613-641, 1997). In contrast to Stute and Zhu's approach (2002) Stute \& Zhu (Scandinavian J Statist 29:535-545, 2002), a transformation is not required. Thus, any problems associated with non-parametric regression estimation are avoided. As a result, the MBB method is much easier for users to implement. To illustrate the power of the MBB based tests, a small simulation study is performed. Compared to the approach of Stute \& Zhu (Scandinavian J Statist 29:535-545, 2002), the simulations indicate a slightly improved power of the MBB based method. Finally, both methods are applied to a real data set.}, language = {en} } @book{KernWettingfeld2015, author = {Kern, Alexander and Wettingfeld, J{\"u}rgen}, title = {Blitzschutzsysteme 2 : Schutz f{\"u}r besondere bauliche Anlagen ; Schutz f{\"u}r elektrische und elektronische Systeme in baulichen Anlagen ; Erl{\"a}uterungen zu den Normen DIN EN 62305-3 (VDE 0185-305-3):2011-10, DIN EN 62305-4 (VDE 0185-305-4):2011-10. (VDE-Schriftenreihe Normen verst{\"a}ndlich ; 160)}, publisher = {VDE-Verl.}, address = {Berlin [u.a.]}, isbn = {978-3-8007-3653-9}, pages = {247 S.}, year = {2015}, language = {de} } @book{KernWettingfeld2014, author = {Kern, Alexander and Wettingfeld, J{\"u}rgen}, title = {Blitzschutzsysteme 1 : allgemeine Grunds{\"a}tze, Risikomanagement, Schutz von baulichen Anlagen und Personen ; Erl{\"a}uterungen zu den Normen DIN EN 62305-1 (VDE 0185-305-1):2011-10, DIN EN 62305-2 (VDE 0185-305-2):2013-02, DIN EN 62305-3 (VDE 0185-305-3):2011-10. (VDE-Schriftenreihe Normen verst{\"a}ndlich ; 44)}, publisher = {VDE-Verl.}, address = {Berlin [u.a.]}, isbn = {978-3-8007-3511-2}, pages = {308 S.}, year = {2014}, language = {de} } @article{KernKloetersPferdmenges2009, author = {Kern, Alexander and Kl{\"o}ters, Georg and Pferdmenges, J{\"o}rg}, title = {Blitzschutzoptimierung in der LST an nicht-elektrifizierten Strecken}, series = {Signal und Draht. 101 (2009), H. 4}, journal = {Signal und Draht. 101 (2009), H. 4}, publisher = {DVV Media Group}, address = {Hamburg}, isbn = {0037-4997}, pages = {17 -- 21}, year = {2009}, language = {de} } @inproceedings{KrichelKernKraemeretal.2003, author = {Krichel, Frank and Kern, Alexander and Kr{\"a}mer, Heinz-Josef and Wettingfeld, J{\"u}rgen and Reetz, Josef and Kienlein, Manfred}, title = {Blitzschutzmaßnahmen f{\"u}r Photovoltaik- und kleine Windenergieanlagen - Einige Beispiele}, year = {2003}, abstract = {Ein von der Arbeitsgemeinschaft (AG) Solar NRW und diversen Industriepartnern gef{\"o}rdertes und an der Fachhochschule Aachen, Abt. J{\"u}lich durchgef{\"u}hrtes Forschungsprojekt „Blitzschutz f{\"u}r netz-autarke Hybridanlagen" machte es m{\"o}glich, sich mit dem Blitzschutz speziell solcher Anlagen n{\"a}her zu besch{\"a}ftigen. Vermehrt bekannt gewordene Schadensf{\"a}lle an nicht netz-gekoppelten Hybridanlagen waren der Ausl{\"o}ser, den Schutz zu {\"u}berdenken. Definiertes Ziel war es, f{\"u}r netz-autarke energietechnische Anlagen ein Konzept zum Schutz vor Blitzeinwirkungen zu erstellen. Diese Anlagen bestehen {\"u}blicherweise aus einer oder mehreren Photovoltaikanlagen, ggf. auch Solarthermieanlagen und einem oder mehreren kleineren Windgeneratoren (sie werden deshalb auch als Hybridanlagen bezeichnet). Zur Erh{\"o}hung der Versorgungssicherheit kann noch ein Dieselaggregat dazukommen. Hybridanlagen werden vor allem in Gebieten mit sehr schlechter {\"o}ffentlicher Energieversorgung eingesetzt, d.h. insbesondere in relativ d{\"u}nn bewohnten Gebieten und in Entwicklungsl{\"a}ndern. Dem Blitzschutz von Hybridanlagen kommt dabei eine steigende Bedeutung zu. Besonderes Augenmerk in dem genannten Forschungsprojekt sollte dabei auf die technisch/wirtschaftliche Ausgewogenheit des Schutzes gelegt werden: • die Schutzmaßnahmen sollen nur in solchen F{\"a}llen eingesetzt werden, wo dies als Ergebnis von Risikoanalysen sinnvoll erscheint; • f{\"u}r typische netz-autarke Hybridanlagen sollen die Schutzmaßnahmen ohne deutliche Verteuerung realisierbar sein (es soll also kein absoluter Schutz realisiert werden; ggf. soll lediglich der auftretende Schaden soweit m{\"o}glich minimiert werden). Dazu wurde in einem ersten Schritt zun{\"a}chst eine Aufnahme des Iststandes einiger typischer netz-autarker Hybridanlagen und deren einzelnen Komponenten durchgef{\"u}hrt. Aufgrund dessen wurde eine umfassende Risikoanalyse zur Blitzbedrohung dieser Anlagen auf der Basis von VDE V 0185 Teil 2:2002-11 [1] erstellt. Die Ergebnisse m{\"u}ndeten in ein technisch/wirtschaftlich ausgewogenes Konzept f{\"u}r den Anlagen- Blitzschutz (d.h. insbesondere dem Schutz vor direkten Blitzeinschl{\"a}gen und deren unmittelbaren Auswirkungen) nach VDE V 0185 Teil 3:2002-11 [2] und f{\"u}r den Elektronik-Blitzschutz (d.h. f{\"u}r den Schutz vor {\"U}berspannungen durch direkte, insbesondere aber auch indirekte Blitzeinschl{\"a}ge) nach VDE V 0185 Teil 4:2002-11 [3]. Aufgrund der gesammelten Ergebnisse konnten dabei allgemeine Empfehlungen f{\"u}r den {\"A}ußeren und Inneren Blitzschutz von regenerativen Energieerzeugungssystemen erstellt werden. Diese sollen in Schulungen einm{\"u}nden, die f{\"u}r Hersteller und Betreiber von Hybridanlagen angeboten werden. Durch die Anwendung wird der Schutz der Anlagen vor Blitzeinwirkung und elektromagnetischen St{\"o}rungen verbessert, was sich in einer reduzierten Ausfallwahrscheinlichkeit bzw. erh{\"o}hten Verf{\"u}gbarkeit wiederspiegelt. An einigen ausgew{\"a}hlten Anlagen werden mit Hilfe der im Projekt involvierten Industriepartner die Schutzmaßnahmen realisiert. Hierbei entstanden den Eigent{\"u}mern bzw. Betreibern der Anlagen keine Kosten. In diesem Beitrag werden beispielhaft drei Anlagenprojekte detailliert gezeigt. Es handelt sich dabei um eine Schweinezuchtfarm in Magall{\´o}n (Spanien, Zaragozza), das bioklimatische Haus (Kreta, Heraklion) und die Tegernseer- H{\"u}tte (Deutschland, Lenggries).}, language = {de} } @inproceedings{KernNeskakisMueller2001, author = {Kern, Alexander and Neskakis, Apostolos and M{\"u}ller, Klaus-Peter}, title = {Blitzschutzkonzept f{\"u}r eine netz-autarke Hybridanlage am Beispiel der Anlage VATALI auf Kreta}, year = {2001}, abstract = {Netz-autarke Anlagen bestehen {\"u}blicherweise aus einer oder mehreren Photovoltaik- (PV-) Anlagen, ggf. auch Solarthermie- (ST-) Anlagen und einem oder mehreren kleineren Windgeneratoren (sie werden deshalb auch als Hybridanlagen bezeichnet) und werden vor allem in Gegenden mit sehr schlechter {\"o}ffentlicher Energieversorgung eingesetzt, d.h. insbesondere in rel. d{\"u}nn bewohnten Gebieten und in Entwicklungsl{\"a}ndern. Der Blitzschutz von netz-autarken Hybridanlagen ist ein bislang noch vergleichsweise unzureichend bearbeitetes Fachgebiet. F{\"u}r große Windenergie-Anlagen (WEA) wurde in den letzten Jahren eine Zahl von FuE-Projekten durchgef{\"u}hrt, zum Großteil finanziert durch die {\"o}ffentliche Hand, zum kleineren Teil auch durch die Industrie, d.h. die WEAHersteller. Dabei wurden bestehende Defizite im Design der WEA festgestellt und Maßnahmen vorgeschlagen, die vor den mechanischen Zerst{\"o}rungen insbesondere des Rotors und vor den St{\"o}rungen und Zerst{\"o}rungen an den elektrischen / elektronischen Systemen der WEA weitgehend Schutz bieten [1, 2, 3]. Der Stand-der- Normung ist im Entwurf DIN VDE 0127 Teil 24 „Blitzschutz f{\"u}r Windenergieanlagen" (dt. {\"U}bersetzung des internationalen Drafts IEC 61400-24 „Wind turbine generator systems; Part 24: Lightning Protection") dokumentiert [4]. Die Maßnahmen sind allerdings insbesondere f{\"u}r gr{\"o}ßere WEA vorgesehen; im Falle kleinerer WEA lassen sie sich nur bedingt umsetzen. Trotzdem sind auch kleinere WEA rel. stark blitzeinschlaggef{\"a}hrdet, wenn sie auf einer Bergkuppe o.{\"a}. platziert werden. F{\"u}r solche kleinere WEA, wie sie bei Hybridanlagen {\"u}blicherweise Verwendung finden, m{\"u}ssen die Blitzschutzmaßnahmen aus der DIN VDE 0127 Teil 24 angepasst werden. F{\"u}r PV- und ST-Anlagen ist eine entsprechende Blitzschutz-Norm noch nicht in Sicht. Hier ist vor allem der Schutz gegen direkte Blitzeinschl{\"a}ge in die Anlage bzw. die Geb{\"a}ude noch nicht ausreichend beachtet. Blitzfangeinrichtungen sind oft nicht vorgesehen. In aller Regel hat man dabei bisher eine Ausf{\"u}hrungsform des Blitzschutzes realisiert, die prim{\"a}r einen Ferneinschlag ber{\"u}cksichtigt und die dabei entstehenden induzierten, rel. energieschwachen {\"U}berspannungen durch schw{\"a}chere Schutzelemente wie R{\"u}ckstromdioden, Bypassdioden und zum Teil thermisch {\"u}berwachte Varistoren begrenzt [5, 6, 7]. Diese Schutzelemente k{\"o}nnen allerdings bei Naheinschl{\"a}gen bzw. Direkteinschl{\"a}gen {\"u}berlastet und damit zerst{\"o}rt werden. Dar{\"u}ber hinaus k{\"o}nnen Nahoder Direkteinschl{\"a}ge auch zur Schw{\"a}chung der elektrischen Festigkeit der PVModulisolierung f{\"u}hren. Die Folge davon sind lokale extreme W{\"a}rmeentwicklungen, die sogar ein Schmelzen von Glas (sekund{\"a}rer Langzeiteffekt) hervorrufen k{\"o}nnten. Bei einem Blitzeinschlag in die netz-autarke Hybridanlage VATALI auf Kreta im Jahre 2000 wurden sowohl einige mechanische wie auch elektrische Komponenten der Anlage zerst{\"o}rt bzw. zum Teil schwer besch{\"a}digt. Die Anlage VATALI besaß zum Zeitpunkt des Blitzeinschlags keinen wirksamen Blitzschutz. Der Gesamtschaden der Hardware belief sich auf ca. 60.000,- EURO. Die exponierte Stellung der Anlage auf einer Bergspitze stellte und stellt nach wie vor ein enormes Blitzeinschlag-Risiko dar, so dass auch zuk{\"u}nftig mit Blitzeinwirkungen gerechnet werden muss. Die Anlage wurde inspiziert, blitzschutz-technische Erfordernisse definiert und daraus Ert{\"u}chtigungsmaßnahmen abgeleitet, die mit {\"u}berschaubarem Aufwand realisierbar sind.}, language = {de} } @inproceedings{KernKraemer2003, author = {Kern, Alexander and Kr{\"a}mer, Heinz-Josef}, title = {Blitzschutzkonzept f{\"u}r eine bauliche Anlage mit Stahlkonstruktion und metallenen W{\"a}nden}, year = {2003}, abstract = {Bauliche Anlagen mit Stahlkonstruktionen (bzw. auch Stahlbetonskelett- Konstruktionen) und metallenen W{\"a}nden sind bereits in sehr großer Zahl errichtet. Dazu geh{\"o}ren kleinere bis gr{\"o}ßere Lagerhallen ebenso wie Einkaufszentren. Sie zeichnen sich durch große Flexibilit{\"a}t, einfache Planung, kurze Bauzeit und rel. geringe Kosten aus. Auch in der nahen Zukunft ist deshalb mit Planung und Errichtung weiterer solcher baulicher Anlagen zu rechnen. Abh{\"a}ngig von der Nutzung der Hallen sind auch mehr oder weniger umfangreiche elektrische und elektronische Systeme vorhanden, die wichtige Funktionen sicherstellen m{\"u}ssen. Der Blitzschutz f{\"u}r diese baulichen Anlagen sollte sich also nicht nur im „klassischen" Geb{\"a}ude-Blitzschutz nach DIN V 0185-3 VDE V 0185 Teil 3 [1] ersch{\"o}pfen; ein Erg{\"a}nzung hin zu einem sinnvollen Grundschutz der elektrischen und elektronischen Systeme nach DIN V 0185-4 VDE V 0185 Teil 4 [2] ist anzuraten. Im folgenden Beitrag wird ein Konzept vorgestellt, mit dem ein hochwertiger Blitzschutz sowohl der baulichen Anlage und der darin befindlichen Personen, als auch der elektrischen und elektronischen Systeme verwirklicht werden kann. Insbesondere bei großfl{\"a}chigen Hallen stellen sich dabei besondere Anforderungen. Das Konzept und die zugeh{\"o}rigen blitzschutz-technischen Maßnahmen k{\"o}nnen drei Hauptbereichen zugeordnet werden: - {\"A}ußerer Blitzschutz; - Innerer Blitzschutz; - weitergehende besondere Maßnahmen. Das Konzept sowie die Maßnahmen werden allgemein beschrieben und teilweise anhand einer ausgef{\"u}hrten Anlage mit Fotos beispielhaft dokumentiert.}, language = {de} } @article{KernHeidlerZahlmannetal.1993, author = {Kern, Alexander and Heidler, Fridolin and Zahlmann, P. and Zischank, Wolfgang J.}, title = {Blitzschutz}, series = {ETZ : Elektrotechnik + Automation. 114 (1993), H. 2}, journal = {ETZ : Elektrotechnik + Automation. 114 (1993), H. 2}, isbn = {0170-1711}, year = {1993}, language = {de} } @article{Kern1995, author = {Kern, Alexander}, title = {Blitz-St{\"o}rschutz als Maßnahme der EMV am Beispiel einer ausgedehnten Industrieanlage}, year = {1995}, language = {de} }