@inproceedings{NoetzoldUphuesWegeneretal.2012, author = {N{\"o}tzold, K. and Uphues, A. and Wegener, R. and Soter, S. and Fink, K. and Bragard, Michael and Griessel, R.}, title = {Inverter based test setup for LVRT verification of a full-scale 2 MW wind power converter}, series = {EPE Joint Wind Energy and T\&D Chapters Seminar : 28th and 29th of June 2012, in the Utzon Centre, Aalborg, Denmark ; papers, posters, presentations. - Session 2: Grid connection, compliance}, booktitle = {EPE Joint Wind Energy and T\&D Chapters Seminar : 28th and 29th of June 2012, in the Utzon Centre, Aalborg, Denmark ; papers, posters, presentations. - Session 2: Grid connection, compliance}, publisher = {EPE Association}, address = {Brussels}, year = {2012}, language = {en} } @article{OrzadaMaderwaldPoseretal.2012, author = {Orzada, S. and Maderwald, S. and Poser, B. A. and Johst, S. and Kannengiesser, S. and Ladd, M. E. and Bitz, Andreas}, title = {Time-interleaved acquisition of modes: an analysis of SAR and image contrast implications}, series = {Magnetic Resonance in Medicine}, volume = {67}, journal = {Magnetic Resonance in Medicine}, number = {4}, publisher = {Wiley-Liss}, address = {New York}, issn = {1522-2594}, doi = {10.1002/mrm.23081}, pages = {1033 -- 1041}, year = {2012}, abstract = {s the magnetic field strength and therefore the operational frequency in MRI are increased, the radiofrequency wavelength approaches the size of the human head/body, resulting in wave effects which cause signal decreases and dropouts. Especially, whole-body imaging at 7 T and higher is therefore challenging. Recently, an acquisition scheme called time-interleaved acquisition of modes has been proposed to tackle the inhomogeneity problems in high-field MRI. The basic premise is to excite two (or more) different Burn:x-wiley:07403194:media:MRM23081:tex2gif-stack-1 modes using static radiofrequency shimming in an interleaved acquisition, where the complementary radiofrequency patterns of the two modes can be exploited to improve overall signal homogeneity. In this work, the impact of time-interleaved acquisition of mode on image contrast as well as on time-averaged specific absorption rate is addressed in detail. Time-interleaved acquisition of mode is superior in Burn:x-wiley:07403194:media:MRM23081:tex2gif-stack-2 homogeneity compared with conventional radiofrequency shimming while being highly specific absorption rate efficient. Time-interleaved acquisition of modes can enable almost homogeneous high-field imaging throughout the entire field of view in PD, T2, and T2*-weighted imaging and, if a specified homogeneity criterion is met, in T1-weighted imaging as well.}, language = {en} } @article{OrzadaBitzJohstetal.2017, author = {Orzada, Stephan and Bitz, Andreas and Johst, S{\"o}ren and Gratz, Marcel and V{\"o}lker, Maximilian N. and Kraff, Oliver and Abuelhaija, Ashraf and Fiedler, Thomas M. and Solbach, Klaus and Quick, Harald H. and Ladd, Mark E.}, title = {Analysis of an integrated 8-Channel Tx/Rx body array for use as a body coil in 7-Tesla MRI}, series = {Frontiers in Physics}, volume = {5}, journal = {Frontiers in Physics}, number = {Jun}, issn = {2296-424X}, doi = {10.3389/fphy.2017.00017}, year = {2017}, language = {en} } @article{OrzadaBitzSchaeferetal.2011, author = {Orzada, Stephan and Bitz, Andreas and Sch{\"a}fer, Lena C. and Ladd, Susanne C. and Ladd, Mark E. and Maderwald, Stefan}, title = {Open design eight-channel transmit/receive coil for high-resolution and real-time ankle imaging at 7 T}, series = {Medical Physics}, volume = {38}, journal = {Medical Physics}, number = {3}, publisher = {Wiley}, address = {Hoboken}, issn = {2473-4209}, doi = {10.1118/1.3553399}, pages = {1162 -- 1167}, year = {2011}, abstract = {Purpose: At 1.5 T, real-time MRI of joint movement has been shown to be feasible. However, 7 T, provides higher SNR and thus an improved potential for parallel imaging acceleration. The purpose of this work was to build an open, U-shaped eight-channel transmit/receive microstrip coil for 7 T MRI to enable high-resolution and real-time imaging of the moving ankle joint. Methods: A U-shaped eight-channel transmit/receive array for the human ankle was built.urn:x-wiley:00942405:mp3399:equation:mp3399-math-0001-parameters and urn:x-wiley:00942405:mp3399:equation:mp3399-math-0002-factor were measured. SAR calculations of different ankle postures were performed to ensure patient safety. Inhomogeneities in the transmit field consequent to the open design were compensated for by the use of static RF shimming. High-resolution and real-time imaging was performed in human volunteers. Results: The presented array showed good performance with regard to patient comfort and image quality. High acceleration factors of up to 4 are feasible without visible acceleration artifacts. Reasonable image homogeneity was achieved with RF shimming. Conclusions: Open, noncylindrical designs for transmit/receive coils are practical at 7 T and real-time imaging of the moving joint is feasible with the presented coil design.}, language = {en} } @article{OrzadaFiedlerBitzetal.2020, author = {Orzada, Stephan and Fiedler, Thomas M. and Bitz, Andreas and Ladd, Mark E. and Quick, Harald H.}, title = {Local SAR compression with overestimation control to reduce maximum relative SAR overestimation and improve multi-channel RF array performance}, series = {Magnetic Resonance Materials in Physics, Biology and Medicine}, journal = {Magnetic Resonance Materials in Physics, Biology and Medicine}, number = {34 (2021)}, publisher = {Springer}, address = {Heidelberg}, isbn = {1352-8661}, doi = {10.1007/s10334-020-00890-0}, pages = {153 -- 164}, year = {2020}, abstract = {Objective In local SAR compression algorithms, the overestimation is generally not linearly dependent on actual local SAR. This can lead to large relative overestimation at low actual SAR values, unnecessarily constraining transmit array performance. Method Two strategies are proposed to reduce maximum relative overestimation for a given number of VOPs. The first strategy uses an overestimation matrix that roughly approximates actual local SAR; the second strategy uses a small set of pre-calculated VOPs as the overestimation term for the compression. Result Comparison with a previous method shows that for a given maximum relative overestimation the number of VOPs can be reduced by around 20\% at the cost of a higher absolute overestimation at high actual local SAR values. Conclusion The proposed strategies outperform a previously published strategy and can improve the SAR compression where maximum relative overestimation constrains the performance of parallel transmission.}, language = {en} } @article{OrzadaJohstMaderwaldetal.2013, author = {Orzada, Stephan and Johst, S{\"o}ren and Maderwald, Stefan and Bitz, Andreas and Solbach, Klaus and Ladd, Mark E.}, title = {Mitigation of B1(+) inhomogeneity on single-channel transmit systems with TIAMO}, series = {Magnetic Resonance in Medicine}, volume = {70}, journal = {Magnetic Resonance in Medicine}, number = {1}, publisher = {Wiley}, address = {Weinheim}, issn = {1522-2594}, doi = {10.1002/mrm.24453}, pages = {290 -- 294}, year = {2013}, language = {en} } @article{OrzadaLaddBitz2016, author = {Orzada, Stephan and Ladd, Mark E. and Bitz, Andreas}, title = {A method to approximate maximum local SAR in multichannel transmit MR systems without transmit phase information}, series = {Magnetic Resonance in Medicine}, volume = {78}, journal = {Magnetic Resonance in Medicine}, number = {2}, publisher = {International Society for Magnetic Resonance in Medicine}, issn = {1522-2594}, doi = {10.1002/mrm.26398}, pages = {805 -- 811}, year = {2016}, abstract = {Purpose To calculate local specific absorption rate (SAR) correctly, both the amplitude and phase of the signal in each transmit channel have to be known. In this work, we propose a method to derive a conservative upper bound for the local SAR, with a reasonable safety margin without knowledge of the transmit phases of the channels. Methods The proposed method uses virtual observation points (VOPs). Correction factors are calculated for each set of VOPs that prevent underestimation of local SAR when the VOPs are applied with the correct amplitudes but fixed phases. Results The proposed method proved to be superior to the worst-case calculation based on the maximum eigenvalue of the VOPs. The mean overestimation for six coil setups could be reduced, whereas no underestimation of the maximum local SAR occurred. In the best investigated case, the overestimation could be reduced from a factor of 3.3 to a factor of 1.7. Conclusion The upper bound for the local SAR calculated with the proposed method allows a fast estimation of the local SAR based on power measurements in the transmit channels and facilitates SAR monitoring in systems that do not have the capability to monitor transmit phases}, language = {en} } @article{OrzadaMaderwaldPoseretal.2010, author = {Orzada, Stephan and Maderwald, Stefan and Poser, Benedikt Andreas and Bitz, Andreas and Quick, Harald H. and Ladd, Mark E.}, title = {RF excitation using time interleaved acquisition of modes (TIAMO) to address B1 inhomogeneity in high-field MRI}, series = {Magnetic Resonance in Medicine}, volume = {64}, journal = {Magnetic Resonance in Medicine}, number = {2}, publisher = {Wiley-Liss}, address = {New York}, issn = {1522-2594}, doi = {10.1002/mrm.22527}, pages = {327 -- 333}, year = {2010}, abstract = {As the field strength and, therefore, the operational frequency in MRI is increased, the wavelength approaches the size of the human head/body, resulting in wave effects, which cause signal decreases and dropouts. Several multichannel approaches have been proposed to try to tackle these problems, including RF shimming, where each element in an array is driven by its own amplifier and modulated with a certain (constant) amplitude and phase relative to the other elements, and Transmit SENSE, where spatially tailored RF pulses are used. In this article, a relatively inexpensive and easy to use imaging scheme for 7 Tesla imaging is proposed to mitigate signal voids due to B1 field inhomogeneity. Two time-interleaved images are acquired using a different excitation mode for each. By forming virtual receive elements, both images are reconstructed together using GRAPPA to achieve a more homogeneous image, with only small SNR and SAR penalty in head and body imaging at 7 Tesla.}, language = {en} } @article{OrzadaSolbachGratzetal.2019, author = {Orzada, Stephan and Solbach, Klaus and Gratz, Marcel and Brunheim, Sascha and Fiedler, Thomas M. and Johst, S{\"o}ren and Bitz, Andreas and Shooshtary, Samaneh and Abuelhaija, Asjraf and Voelker, Maximilian N. and Rietsch, Stefan H. G. and Kraff, Oliver and Maderwald, Stefan and Fl{\"o}ser, Martina and Oehmingen, Mark and Quick, Harald H. and Ladd, Mark E.}, title = {A 32-channel parallel transmit system add-on for 7T MRI}, series = {Plos one}, journal = {Plos one}, doi = {10.1371/journal.pone.0222452}, year = {2019}, language = {en} } @inproceedings{OstkottePetersHueningetal.2022, author = {Ostkotte, Sebastian and Peters, Constantin and H{\"u}ning, Felix and Bragard, Michael}, title = {Design, implementation and verification of an rotational incremental position encoder based on the magnetic Wiegand effect}, series = {2022 ELEKTRO (ELEKTRO)}, booktitle = {2022 ELEKTRO (ELEKTRO)}, publisher = {IEEE}, isbn = {978-1-6654-6726-1}, issn = {2691-0616}, doi = {10.1109/ELEKTRO53996.2022.9803477}, pages = {6 Seiten}, year = {2022}, abstract = {This paper covers the use of the magnetic Wiegand effect to design an innovative incremental encoder. First, a theoretical design is given, followed by an estimation of the achievable accuracy and an optimization in open-loop operation. Finally, a successful experimental verification is presented. For this purpose, a permanent magnet synchronous machine is controlled in a field-oriented manner, using the angle information of the prototype.}, language = {en} } @article{OssmannHattrupBroeck2003, author = {Oßmann, Martin and Hattrup, C. and Broeck, H. W. van der}, title = {Fast estimation techniques for digital control of resonant converters / Hattrup, C.; van der Broeck, H.W.; Ossmann, M.;}, series = {IEEE Transaction on Power Electronics. 18 (2003), H. 1}, journal = {IEEE Transaction on Power Electronics. 18 (2003), H. 1}, isbn = {0885-8993}, pages = {365 -- 372}, year = {2003}, language = {en} } @article{OssmannKazay2000, author = {Oßmann, Martin and Kazay, B.}, title = {Simple circuit provides high-side current sensing / Ossmann, M ; Kazay, B.}, series = {EDN. 45 (2000), H. 21}, journal = {EDN. 45 (2000), H. 21}, isbn = {0012-7515}, pages = {200 -- 200}, year = {2000}, language = {en} } @article{OssmannKazay1999, author = {Oßmann, Martin and Kazay, B.}, title = {Single mu C pin makes half-duplex RS-232C / Ossmann, M}, series = {EDN. 44 (1999), H. 16}, journal = {EDN. 44 (1999), H. 16}, isbn = {0012-7515}, pages = {118}, year = {1999}, language = {en} } @article{PelikanScholl1997, author = {Pelikan, Erich and Scholl, Ingrid}, title = {Die Wavelet-Transformation. Pelikan, Erich; Scholl, Ingrid}, series = {Bildverarbeitung f{\"u}r die Medizin. Lehmann, T.; Oberschelp, W.; Pelikan, E.; Repges,R.}, journal = {Bildverarbeitung f{\"u}r die Medizin. Lehmann, T.; Oberschelp, W.; Pelikan, E.; Repges,R.}, publisher = {Springer}, address = {Berlin}, pages = {253 -- 282}, year = {1997}, language = {de} } @inproceedings{PenneProfittlichRingbecketal.2010, author = {Penne, Jochen and Profittlich, Martin and Ringbeck, Thorsten and Buxbaum, Bernd}, title = {Touchless detailed 3D scan of human hand anatomy using time-of-flight cameras}, series = {Proceedings of the International Conference on 3D Body Scanning Technologies : Lugano, Switzerland, 19-20 October 2010}, booktitle = {Proceedings of the International Conference on 3D Body Scanning Technologies : Lugano, Switzerland, 19-20 October 2010}, editor = {D, Nicola D'Apuzzo}, publisher = {Hometrica Consulting}, address = {Z{\"u}rich}, isbn = {978-3-033-02714-5}, pages = {361 -- 369}, year = {2010}, language = {en} } @incollection{PfetschAbeleAltherretal.2021, author = {Pfetsch, Marc E. and Abele, Eberhard and Altherr, Lena and B{\"o}lling, Christian and Br{\"o}tz, Nicolas and Dietrich, Ingo and Gally, Tristan and Geßner, Felix and Groche, Peter and Hoppe, Florian and Kirchner, Eckhard and Kloberdanz, Hermann and Knoll, Maximilian and Kolvenbach, Philip and Kuttich-Meinlschmidt, Anja and Leise, Philipp and Lorenz, Ulf and Matei, Alexander and Molitor, Dirk A. and Niessen, Pia and Pelz, Peter F. and Rexer, Manuel and Schmitt, Andreas and Schmitt, Johann M. and Schulte, Fiona and Ulbrich, Stefan and Weigold, Matthias}, title = {Strategies for mastering uncertainty}, series = {Mastering uncertainty in mechanical engineering}, booktitle = {Mastering uncertainty in mechanical engineering}, publisher = {Springer}, address = {Cham}, isbn = {978-3-030-78353-2}, doi = {10.1007/978-3-030-78354-9_6}, pages = {365 -- 456}, year = {2021}, abstract = {This chapter describes three general strategies to master uncertainty in technical systems: robustness, flexibility and resilience. It builds on the previous chapters about methods to analyse and identify uncertainty and may rely on the availability of technologies for particular systems, such as active components. Robustness aims for the design of technical systems that are insensitive to anticipated uncertainties. Flexibility increases the ability of a system to work under different situations. Resilience extends this characteristic by requiring a given minimal functional performance, even after disturbances or failure of system components, and it may incorporate recovery. The three strategies are described and discussed in turn. Moreover, they are demonstrated on specific technical systems.}, language = {en} } @inproceedings{PisarczykRitzSachtleben2013, author = {Pisarczyk, Rafael and Ritz, Thomas and Sachtleben, Johanna}, title = {KMU-taugliche Modelle zur Entwicklung gebrauchstauglicher mobiler Unternehmenssoftware}, series = {Mensch \& Computer 2013 - Workshopband : 13. fach{\"u}bergreifende Konferenz f{\"u}r interaktive und kooperative Medien}, booktitle = {Mensch \& Computer 2013 - Workshopband : 13. fach{\"u}bergreifende Konferenz f{\"u}r interaktive und kooperative Medien}, editor = {Boll-Westermann, Susanne}, publisher = {Oldenbourg}, address = {M{\"u}nchen}, isbn = {978-3-486-77855-7 (Print)}, doi = {10.1524/9783486781236}, pages = {29 -- 38}, year = {2013}, language = {de} } @techreport{PisarczykRitzWallenborn2014, author = {Pisarczyk, Rafael and Ritz, Thomas and Wallenborn, Ramona}, title = {Unterschiedliche Entwicklungsans{\"a}tze von Multiplattform-Anwendungen : Markt{\"u}bersicht}, publisher = {eBusiness-Lotse}, address = {Aachen}, pages = {15 S. : Ill., graph. Darst.}, year = {2014}, abstract = {Die Markt{\"u}bersicht „Unterschiedliche Entwicklungsans{\"a}tze von Multiplattform-Anwendungen" richtet sich an IT-Dienstleister, Entwickler und IT-Abteilungen von Unternehmen, die Multiplattform Anwendungen entwickeln. In dieser Markt{\"u}bersicht werden verschiedene Entwicklungsans{\"a}tze beschrieben und ihre jeweiligen Vor- und Nachteile aufgezeigt.}, language = {de} } @article{PoppelWolf2013, author = {Poppel, Kristin Isabel and Wolf, Martin}, title = {M{\"o}glichkeiten und Potentiale von Revisionsmarketing}, series = {Zeitschrift Interne Revision : ZIR ; Fachzeitschrift f{\"u}r Wissenschaft und Praxis}, volume = {48}, journal = {Zeitschrift Interne Revision : ZIR ; Fachzeitschrift f{\"u}r Wissenschaft und Praxis}, number = {4}, publisher = {Erich Schmidt Verlag}, address = {Berlin}, issn = {0044-3816}, pages = {200 -- 208}, year = {2013}, language = {de} } @incollection{PriedeFerrein2013, author = {Priede, Gareth and Ferrein, Alexander}, title = {Towards passive walking for the fully-actuated biped robot Nao}, series = {Emerging trends in computing, informatics, systems sciences, and engineering. (Lecture notes in electrical engineering : vol. 151)}, booktitle = {Emerging trends in computing, informatics, systems sciences, and engineering. (Lecture notes in electrical engineering : vol. 151)}, publisher = {Springer}, address = {New York, NY}, isbn = {978-1-4614-3557-0 ; 978-1-4614-3558-7}, doi = {10.1007/978-1-4614-3558-7_18}, pages = {225 -- 236}, year = {2013}, abstract = {Many biped robots deploy a form of gait that follows the zero moment point (ZMP) approach, that is, the robot is in a stable position at any point in time. This requires the robot to be fully actuated. While very stable, the draw-backs of this approach are a fairly slow gait and high energy consumption. An alternative approach is the so-called passive-dynamic walking, where the gait makes use of the inertia and dynamic stability of the robot. In this paper we describe our ongoing work of combining the principles of passive-dynamic walking on the fully-actuated biped robot Nao, which is also deployed for robotic soccer applications. We present a simple controller that allows the robot to stably rock sidewards, showing a closed limit-cycle. We discuss first results of superimposing a forward motion on the sidewards motion. Based on this we expect to endow the Nao with a fast, robust, and stable passive-dynamic walk on the fully-actuated Nao in the future.}, language = {en} }