@article{BaeckerPoghossianAbouzaretal.2010, author = {B{\"a}cker, Matthias and Poghossian, Arshak and Abouzar, Maryam H. and Wenmackers, Sylvia and Janssens, Stoffel D. and Haenen, Ken and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Capacitive field-effect (bio-)chemical sensors based on nanocrystalline diamond films}, series = {Diamond Electronics and Bioelectronics — Fundamentals to Applications III, edited by P. Bergonzo, [u.a.]}, journal = {Diamond Electronics and Bioelectronics — Fundamentals to Applications III, edited by P. Bergonzo, [u.a.]}, pages = {1 -- 6}, year = {2010}, language = {en} } @article{Digel2010, author = {Digel, Ilya}, title = {In-situ biological decontamination of an ice melting probe}, year = {2010}, language = {en} } @inproceedings{DigelLeimenaDachwaldetal.2010, author = {Digel, Ilya and Leimena, W. and Dachwald, Bernd and Linder, Peter and Porst, Dariusz and Kayser, Peter and Funke, O. and Temiz Artmann, Ayseg{\"u}l and Artmann, Gerhard}, title = {In-situ biological decontamination of an ice melting probe : [abstract]}, year = {2010}, abstract = {The objective of our study was to investigate the efficacy of different in-situ decontamination protocols in the conditions of thermo-mechanical ice-melting.}, subject = {Sonde}, language = {en} } @article{GarhoferBekBoehmetal.2010, author = {Garhofer, Gerhard and Bek, Toke and Boehm, Andreas G. and Gherghel, Doina and Grundwald, Juan and Jeppesen, Peter and Kergoat, H{\´e}l{\`e}ne and Kotliar, Konstantin and Lanzl, Ines and Lovasik, John V. and Nagel, Edgar and Vilser, Walthard and Orgul, Selim and Schmetterer, Leopold}, title = {Use of the retinal vessel analyzer in ocular blood flow research}, series = {Acta Ophthalmol}, volume = {88}, journal = {Acta Ophthalmol}, number = {7}, publisher = {Wiley-Blackwell}, address = {Oxford}, issn = {1755-3768}, doi = {10.1111/j.1755-3768.2009.01587.x}, pages = {717 -- 722}, year = {2010}, abstract = {The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed.}, language = {en} } @article{GerhardsBelloumBerretzetal.2010, author = {Gerhards, M. and Belloum, A. and Berretz, F. and Sander, Volker and Skorupa, S.}, title = {A history-tracing XML-based provenance framework for workflows}, isbn = {978-1-4244-8989-3}, pages = {1 -- 10}, year = {2010}, language = {en} } @article{GrajewskiKoesterTurek2010, author = {Grajewski, Matthias and K{\"o}ster, Michael and Turek, Stefam}, title = {Numerical analysis and implementational aspects of a new multilevel grid deformation method}, series = {Applied Numerical Mathematics}, volume = {60}, journal = {Applied Numerical Mathematics}, number = {8}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0168-9274}, doi = {10.1016/j.apnum.2010.03.017}, pages = {767 -- 781}, year = {2010}, abstract = {Recently, we introduced and mathematically analysed a new method for grid deformation (Grajewski et al., 2009) [15] we call basic deformation method (BDM) here. It generalises the method proposed by Liao et al. (Bochev et al., 1996; Cai et al., 2004; Liao and Anderson, 1992) [4], [6], [20]. In this article, we employ the BDM as core of a new multilevel deformation method (MDM) which leads to vast improvements regarding robustness, accuracy and speed. We achieve this by splitting up the deformation process in a sequence of easier subproblems and by exploiting grid hierarchy. Being of optimal asymptotic complexity, we experience speed-ups up to a factor of 15 in our test cases compared to the BDM. This gives our MDM the potential for tackling large grids and time-dependent problems, where possibly the grid must be dynamically deformed once per time step according to the user's needs. Moreover, we elaborate on implementational aspects, in particular efficient grid searching, which is a key ingredient of the BDM.}, language = {en} } @article{GrottkeBraunschweigPhilippenetal.2010, author = {Grottke, O. and Braunschweig, T. and Philippen, B. and Gatzweiler, Karl-Heinz and Gronloh, N. and Staat, Manfred and Rossaint, R. and Tolba, R.}, title = {A New Model for Blunt Liver Injuries in the Swine}, series = {European Surgical Research. 44 (2010), H. 2}, journal = {European Surgical Research. 44 (2010), H. 2}, isbn = {1421-9921}, pages = {65 -- 73}, year = {2010}, language = {en} } @article{HeinzelSchaeferMuelleretal.2010, author = {Heinzel, Alexander and Sch{\"a}fer, Ralf and M{\"u}ller, Hans-Wilhelm and Schieffer, Andre and Ingenhag, Ariane and Eickhoff, Simon B. and Northoff, Georg and Franz, Matthias and Hautzel, Hubertus}, title = {Increased Activation of the Supragenual Anterior Cingulate Cortex during Visual Emotional Processing in Male Subjects with High Degrees of Alexithymia: An Event-Related fMRI Study}, series = {Psychotherapy and Psychosomatics}, volume = {79}, journal = {Psychotherapy and Psychosomatics}, number = {6}, publisher = {Karger}, address = {Basel}, issn = {0033-3190}, doi = {10.1159/000320121}, pages = {363 -- 370}, year = {2010}, abstract = {Background: One of the most prominent neurobiological models of alexithymia assumes an altered function of the anterior cingulate cortex (ACC) as the crucial neural correlate of alexithymia. So far functional imaging studies have yielded inconclusive results. Therefore, we tested this hypothesis in healthy alexithymics and nonalexithymics in an event-related fMRI study. Methods: Thirty high- and 30 low-alexithymic right-handed male subjects (selected by the 20-item Toronto Alexithymia Scale, TAS-20) were investigated with event-related fMRI using a picture viewing paradigm. The stimuli consisted of happy, fearful and neutral facial expressions (Ekman-Friesen) as well as positive, negative and neutral pictures from the International Affective Picture System. Results: Contrasting the high-alexithymic with the low-alexithymic group we observed increased activation of the supragenual ACC for different emotional valences as well as for different emotional stimuli. Moreover, there was a positive correlation of the ACC with the individual TAS-20 scores but no correlations with the individual Beck Depression Inventory scores. Additionally, there was no difference in activity of the amygdala. Conclusions: We demonstrated that the supragenual ACC is constantly activated more strongly in alexithymic subjects and that this activation is related to the symptoms of alexithymia and not to associated symptoms such as depression. Therefore, our findings support the hypothesis of an altered function of the ACC in alexithymia.}, language = {en} } @article{HeinzelSchaeferMuelleretal.2010, author = {Heinzel, Alexander and Sch{\"a}fer, Ralf and M{\"u}ller, Hans-Wilhelm and Schieffer, Andre and Ingenhag, Ariane and Northoff, Georg and Franz, Matthias and Hautzel, Hubertus}, title = {Differential modulation of valence and arousal in high-alexithymic and low-alexithymic individuals}, series = {Neuroreport}, volume = {21}, journal = {Neuroreport}, number = {15}, publisher = {Lippincott Williams \& Wilkins}, address = {London}, issn = {1473-558X}, doi = {10.1097/WNR.0b013e32833f38e0}, pages = {998 -- 1002}, year = {2010}, abstract = {High-alexithymic individuals are characterized by an impaired ability to identify and communicate emotions whereas low-alexithymic individuals have a wide-ranging ability to deal with emotions. This study examined the hypothesis that valence and arousal modifications of emotional stimuli differentially modulate cortical regions in high-alexithymic and low-alexithymic individuals. To this end, 28 high-alexithymic and 25 low-alexithymic individuals were investigated with event-related fMRI using visual emotional stimuli. We found differential neural activations in the dorsal anterior cingulate, the insula and the amygdala. We suggest that these differences may account for the impaired ability of high-alexithymic individuals to appropriately handle emotional stimuli.}, language = {en} } @article{HerzogPietrzykShahetal.2010, author = {Herzog, Hans and Pietrzyk, Uwe and Shah, N. Jon and Ziemons, Karl}, title = {The current state, challenges and perspectives of MR-PET}, series = {Neuroimage}, volume = {49}, journal = {Neuroimage}, number = {3}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1053-8119}, doi = {10.1016/j.neuroimage.2009.10.036}, pages = {2072 -- 2082}, year = {2010}, abstract = {Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization. Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum J{\"u}lich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27-28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop.}, language = {en} } @article{HirschfeldLustfeldReisseletal.2010, author = {Hirschfeld, J. A. and Lustfeld, H. and Reißel, Martin and Steffen, B.}, title = {A novel scheme for precise diagnostics and effective stabilization of currents in a fuel cell stack}, series = {International Journal of Energy Research. 34 (2010), H. 3}, journal = {International Journal of Energy Research. 34 (2010), H. 3}, isbn = {0363-907X}, pages = {293 -- 301}, year = {2010}, language = {en} } @article{HirschfeldLustfeldReisseletal.2010, author = {Hirschfeld, J. A. and Lustfeld, H. and Reißel, Martin and Steffen, B.}, title = {Tomographic diagnostics of current distributions in a fuel cell stack}, series = {International Journal of Energy Research}, volume = {34}, journal = {International Journal of Energy Research}, number = {3}, isbn = {0363-907X}, pages = {284 -- 292}, year = {2010}, language = {en} } @article{HorstmannBialonskiNoenningetal.2010, author = {Horstmann, Marie-Therese and Bialonski, Stephan and Noenning, Nina and Mai, Heinke and Prusseit, Jens and Wellmer, J{\"o}rg and Hinrichs, Hermann and Lehnertz, Klaus}, title = {State dependent properties of epileptic brain networks: Comparative graph-theoretical analyses of simultaneously recorded EEG and MEG}, series = {Clinical Neurophysiology}, volume = {121}, journal = {Clinical Neurophysiology}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1388-2457}, doi = {10.1016/j.clinph.2009.10.013}, pages = {172 -- 185}, year = {2010}, abstract = {Objective To investigate whether functional brain networks of epilepsy patients treated with antiepileptic medication differ from networks of healthy controls even during the seizure-free interval. Methods We applied different rules to construct binary and weighted networks from EEG and MEG data recorded under a resting-state eyes-open and eyes-closed condition from 21 epilepsy patients and 23 healthy controls. The average shortest path length and the clustering coefficient served as global statistical network characteristics. Results Independent on the behavioral condition, epileptic brains exhibited a more regular functional network structure. Similarly, the eyes-closed condition was characterized by a more regular functional network structure in both groups. The amount of network reorganization due to behavioral state changes was similar in both groups. Consistent findings could be achieved for networks derived from EEG but hardly from MEG recordings, and network construction rules had a rather strong impact on our findings. Conclusions Despite the locality of the investigated processes epileptic brain networks differ in their global characteristics from non-epileptic brain networks. Further methodological developments are necessary to improve the characterization of disturbed and normal functional networks. Significance An increased regularity and a diminished modulation capability appear characteristic of epileptic brain networks.}, language = {en} } @article{JansenBehbahaniLaumenetal.2010, author = {Jansen, S. V. and Behbahani, Mehdi and Laumen, M. and Kaufmann, T. and Hormes, M. and Behr, M. and Schmitz-Rode, T. and Steinseifer, U.}, title = {Investigation of Steady Flow Through a Realistic Model of the Thoracic Human Aorta Using 3D Stereo PIV and CFD-Simulation}, year = {2010}, language = {en} } @article{JansenBehbahaniLaumenetal.2010, author = {Jansen, Sebastian and Behbahani, Mehdi and Laumen, Marco and Kaufmann, Tim and Hormes, Marcus and Schmitz-Rode, Thomas and Behr, Marek and Steinseifer, Ulrich}, title = {3D Stereo-PIV Validation for CFD-Simulation of Steady Flow through the Human Aorta using Rapid-Prototyping techniques}, year = {2010}, language = {en} } @article{KirchnerOberlaenderFriedrichetal.2010, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Friedrich, Peter and Rysstad, G. and Berger, J. and Keusgen, M. and Sch{\"o}ning, Michael Josef}, title = {Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry}, series = {Procedia Engineering. 5 (2010)}, journal = {Procedia Engineering. 5 (2010)}, isbn = {1877-7058}, pages = {264 -- 267}, year = {2010}, language = {en} } @article{KotliarNagelVilseretal.2010, author = {Kotliar, Konstantin and Nagel, Edgar and Vilser, Walthard and Seidova, Seid-Fatima and Lanzl, Ines}, title = {Microstructural alterations of retinal arterial blood column along the vessel axis in systemic hypertension}, series = {Investigative Ophthalmology \& Visual Science, IOVS}, volume = {51}, journal = {Investigative Ophthalmology \& Visual Science, IOVS}, number = {4}, publisher = {ARVO}, address = {Rockville, Md.}, issn = {0146-0404}, doi = {10.1167/iovs.09-3649}, pages = {2165 -- 2172}, year = {2010}, abstract = {Purpose: Image analysis by the retinal vessel analyzer (RVA) observes retinal vessels in their dynamic state online noninvasively along a chosen vessel segment. It has been found that high-frequency diameter changes in the retinal artery blood column along the vessel increase significantly in anamnestically healthy volunteers with increasing age and in patients with glaucoma during vascular dilation. This study was undertaken to investigate whether longitudinal sections of the retinal artery blood column are altered in systemic hypertension. Methods: Retinal arteries of 15 untreated patients with essential arterial hypertension (age, 50.9 ± 11.9 years) and of 15 age-matched anamnestically healthy volunteers were examined by RVA. After baseline assessment, a monochromatic luminance flicker (530-600 nm; 12.5 Hz; 20 s) was applied to evoke retinal vasodilation. Differences in amplitude and frequency of spatial artery blood column diameter change along segments (longitudinal arterial profiles) of 1 mm in length were measured and analyzed using Fourier transformation. Results: In the control group, average reduced power spectra (ARPS) of longitudinal arterial profiles did not differ when arteries changed from constriction to dilation. In the systemic hypertension group, ARPS during constriction, baseline, and restoration were identical and differed from ARPS during dilation (P < 0.05). Longitudinal arterial profiles in both groups showed significant dissimilitude at baseline and restoration (P < 0.05). Conclusions: The retinal artery blood column demonstrates microstructural alterations in systemic hypertension and is less irregular along the vessel axis during vessel dilation. These microstructural changes may be an indication of alterations in vessel wall rigidity, vascular endothelial function, and smooth muscle cells in this disease, leading to impaired perfusion and regulation.}, language = {en} } @article{KozhalakovaZhubanovaMansurovetal.2010, author = {Kozhalakova, A. A. and Zhubanova, Azhar A. and Mansurov, Z. A. and Digel, Ilya and Tazhibayeva, S. M. and Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l}, title = {Adsorption of bacterial lipopolysaccharides on carbonized rice shell}, series = {Science of Central Asia (2010)}, journal = {Science of Central Asia (2010)}, pages = {50 -- 54}, year = {2010}, language = {en} } @inproceedings{KurulganDemirciLinderDemircietal.2010, author = {Kurulgan Demirci, Eylem and Linder, Peter and Demirci, Taylan and Gierkowski, Jessica R. and Digel, Ilya and Gossmann, Matthias and Temiz Artmann, Ayseg{\"u}l}, title = {rhAPC reduces the endothelial cell permeability via a decrease of cellular mechanical contractile tensions : [abstract]}, year = {2010}, abstract = {In this study, the CellDrum technology quanitfying cellular mechanical tension on a pico-scale was used to investigate the effect of LPS (lipopolysaccharide) on HAoEC (Human Aortic Endothelial Cell) tension.}, subject = {Endothelzelle}, language = {en} } @article{KurzLinderTrzewiketal.2010, author = {Kurz, R. and Linder, Peter and Trzewik, J{\"u}rgen and R{\"u}ffer, M. and Artmann, Gerhard and Digel, Ilya and Rothermel, A. and Robitzki, A. and Temiz Artmann, Ayseg{\"u}l}, title = {Contractile tension and beating rates of self-exciting monolayers and 3D-tissue constructs of neonatal rat cardiomyocytes}, series = {Medical and Biological Engineering and Computing}, volume = {48}, journal = {Medical and Biological Engineering and Computing}, number = {1}, publisher = {Springer Nature}, address = {Cham}, issn = {1741-0444}, doi = {10.1007/s11517-009-0552-y}, pages = {59 -- 65}, year = {2010}, abstract = {The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocytes. Cells were grown either within flexible, circular collagen gels or as monolayer on top of respective 1-mum thin silicone membranes. Membrane and cells were bulged outwards by air pressure. This biaxial strain distribution is rather similar the beating, blood-filled heart. The setup allowed presetting the mechanical residual stress level externally by adjusting the centre deflection, thus, mimicking hypertension in vitro. Tension was measured as oscillating differential pressure change between chamber and environment. A 0.5-mm thick collagen-cardiac myocyte tissue construct induced after 2 days of culturing (initial cell density 2 x 10(4) cells/ml), a mechanical tension of 1.62 +/- 0.17 microN/mm(2). Mechanical load is an important growth regulator in the developing heart, and the orientation and alignment of cardiomyocytes is stress sensitive. Therefore, it was necessary to develop the CellDrum technology with its biaxial stress-strain distribution and defined mechanical boundary conditions. Cells were exposed to strain in two directions, radially and circumferentially, which is similar to biaxial loading in real heart tissues. Thus, from a biomechanical point of view, the system is preferable to previous setups based on uniaxial stretching.}, language = {en} }