@article{UndenBeckerBongaertsetal.1995, author = {Unden, G. and Becker, S. and Bongaerts, Johannes and Holighaus, G. and Schirawski, J. and Six, S.}, title = {O2-sensing and O2-dependent gene regulation in facultatively anaerobic bacteria}, series = {Archives of microbiology}, volume = {Vol. 164}, journal = {Archives of microbiology}, number = {Iss. 2}, issn = {1432-072X (E-Journal); 0003-9276 (Print); 0302-8933 (Print)}, pages = {81 -- 90}, year = {1995}, language = {en} } @inproceedings{TippkoetterStueckmannWinkelmannetal.2007, author = {Tippk{\"o}tter, Nils and St{\"u}ckmann, H. and Winkelmann, G. and Noack, U. and Beutel, S. and Scheper, T. and Ulber, Roland}, title = {Optimisation of antibody-labelling of gold colloids for their application in an immunchromatographic assay for microcystin-LR}, series = {European BioPerspectives : celebrating the 25th DECHEMA annual convention of biotechnologists ; 30 May - 1 June 2007, Cologne, Germany ; book of abstracts ; abstracts, poster programme}, booktitle = {European BioPerspectives : celebrating the 25th DECHEMA annual convention of biotechnologists ; 30 May - 1 June 2007, Cologne, Germany ; book of abstracts ; abstracts, poster programme}, publisher = {Dechema}, address = {Frankfurt am Main}, pages = {126}, year = {2007}, language = {en} } @misc{AlKaidyTippkoetterUlber2016, author = {Al-Kaidy, Huschyar and Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Vorrichtung und Verfahren zur Bestimmung des Kontaktwinkels eines Fl{\"u}ssigk{\"o}rpers mit einer Festk{\"o}rperoberfl{\"a}che}, year = {2016}, abstract = {Die vorliegende Erfindung betrifft eine Vorrichtung und ein Verfahren zur Bestimmung des Kontaktwinkels eines fl{\"u}ssigen oder mit Fl{\"u}ssigkeit gef{\"u}llten K{\"o}rpers. Dieser besteht aus einem Tr{\"a}ger (1) und einer damit verbundenen, in einem Winkelbereich von mehr als 0 ° bis maximal 90 ° neigbaren Ebene (8) mit einer darin ausgebildeten Abrollbahn (9) f{\"u}r den fl{\"u}ssigen oder mit Fl{\"u}ssigkeit gef{\"u}llten K{\"o}rper. An der Ebene (8) sind mehrere Sensoren (11,12) zur Erfassung der Rolldauer des K{\"o}rpers entlang der Rollstrecke angeordnet. Erfindungsgem{\"a}ß ist vorgesehen, dass die Einstellung des Neigungswinkels der Ebene (8) {\"u}ber ein Winkelmessger{\"a}t (10) erfolgt, wodurch ein Abrollwinkel erfassbar ist, bei dem der K{\"o}rper in Bewegung ger{\"a}t. Aus der Rolldauer, der Rollstrecke und dem Abrollwinkel wird der Kontaktwinkel des K{\"o}rpers ermittelt.}, language = {de} } @article{TippkoetterDeterdingUlber2008, author = {Tippk{\"o}tter, Nils and Deterding, A. and Ulber, Roland}, title = {Determination of acetic acid in fermentation broth by gas-diffusion technique}, series = {Engineering in Life Sciences}, volume = {8}, journal = {Engineering in Life Sciences}, number = {1, Special Issue: Technical Systems for the Use in Life Sciences}, doi = {10.1002/elsc.200820227}, pages = {62 -- 67}, year = {2008}, abstract = {Due to the interfering effects of acetic acid in many fermentation processes, a gas-diffusion technique was developed for the online determination of acetic acid. The measurements were accomplished with a flow diffusion analysis (FDA) unit from the TRACE Analytics GmbH, Braunschweig, Germany. The diffusion analysis is based on the UV-absorbance of acetic acid at 205 nm. The measurement was achieved by the separation of an acceptor and a carrier stream (acidified fermentation broth) using a gas permeable polytetrafluoroethylene (PTFE) membrane, whereby broth constituents that would otherwise disturb the UV-measurement of acetic acid, are held back efficiently. Merely, the fermentation by-products, e.g. formic acid, is capable of diffusing through the membrane. While formic acid can disturb the measurement, carbon dioxide does not absorb at 205 nm. The method operates with time-dependent sample enrichment. During the analysis, a small volume of the acceptor stream is stopped for a defined time interval in the acceptor chamber. During this period, the gaseous acetic acid diffuses through the membrane and is enriched in the acceptor chamber. Subsequently after the enrichment, the acceptor stream flows through a UV-detector. The intensity of the signal is proportional to the acetic acid concentration. Online measurements in bioreactors via a sterile filtration probe have been accomplished. A linear calibration in the range of 0.5-5.0 g/L acetic acid with a relative standard deviation of <5 \% was obtained. A sampling rate of 8 samples per hour was possible. The system was applied for the determination of acetic acid in E. coli fermentation broth. The instrument is easy to clean, very user-friendly and does not require any toxic or expensive reagents.}, language = {en} } @article{BaeckerRakowskiPoghossianetal.2013, author = {B{\"a}cker, Matthias and Rakowski, D. and Poghossian, Arshak and Biselli, Manfred and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Chip-based amperometric enzyme sensor system for monitoring of bioprocesses by flow-injection analysis}, series = {Journal of Biotechnology}, volume = {163}, journal = {Journal of Biotechnology}, number = {4}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0168-1656}, doi = {10.1016/j.jbiotec.2012.03.014}, pages = {371 -- 376}, year = {2013}, abstract = {A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses.}, language = {en} } @article{TranBongaertsVladetal.1997, author = {Tran, Quang Hon and Bongaerts, Johannes and Vlad, Dorina and Unden, Gottfried}, title = {Requirement for the proton-pumping NADH dehydrogenase I of Escherichia coli in respiration of NADH to fumarate and its bioenergetic implications}, series = {European journal of biochemistry}, volume = {Vol. 244}, journal = {European journal of biochemistry}, number = {Iss. 1}, issn = {0014-2956}, pages = {155 -- 160}, year = {1997}, language = {en} } @article{WiegandVoigtAlbrechtetal.2013, author = {Wiegand, Sandra and Voigt, Birgit and Albrecht, Dirk and Bongaerts, Johannes and Evers, Stefan and Hecker, Michael and Daniel, Rolf and Liesegang, Heiko}, title = {Fermentation stage-dependent adaptations of Bacillus licheniformis during enzyme production}, series = {Microbial Cell Factories}, volume = {12}, journal = {Microbial Cell Factories}, publisher = {Biomed Central}, address = {London}, issn = {1475-2859}, doi = {10.1186/1475-2859-12-120}, pages = {120}, year = {2013}, language = {en} } @inproceedings{TippkoetterRoikaewUlber2008, author = {Tippk{\"o}tter, Nils and Roikaew, W. and Ulber, Roland}, title = {An automated pilot plant for the bioengineering processing of concentrated whey}, series = {European BioPerspectives : in cooperation with BIOTECHNICA 2008 : 7 - 9 October 2008 Hannover, Germany ; book of abstracts ; abstracts, poster programme}, booktitle = {European BioPerspectives : in cooperation with BIOTECHNICA 2008 : 7 - 9 October 2008 Hannover, Germany ; book of abstracts ; abstracts, poster programme}, publisher = {Dechema}, address = {Frankfurt am Main}, pages = {98}, year = {2008}, language = {en} } @article{ZientzBongaertsUnden1998, author = {Zientz, Evelyn and Bongaerts, Johannes and Unden, Gottfried}, title = {Fumarate regulation of gene expression in Escherichia coli by the DcuSR (dcuSR genes) two-component regulatory system}, series = {Journal of bacteriology}, volume = {Vol. 180}, journal = {Journal of bacteriology}, number = {No. 20}, issn = {1098-5530 (E-Journal); 0021-9193 (Print)}, pages = {5421 -- 5425}, year = {1998}, language = {en} } @inproceedings{DeterdingTippkoetterUlber2006, author = {Deterding, A. and Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Online-Essigs{\"a}ureanalytik in Fermentationsbr{\"u}hen mittels Fließdiffusionstechnik (FDT)}, series = {Technische Systeme f{\"u}r Biotechnologie und Umwelt : 13. Heiligenst{\"a}dter Kolloquium, Heilbad Heiligenstadt, 25.09. - 27.09.2006}, booktitle = {Technische Systeme f{\"u}r Biotechnologie und Umwelt : 13. Heiligenst{\"a}dter Kolloquium, Heilbad Heiligenstadt, 25.09. - 27.09.2006}, editor = {Beckmann, Dieter}, address = {Heiligenstadt}, organization = {Institut f{\"u}r Bioprozeß- und Analysenmeßtechnik}, isbn = {978-3-00-018621-9}, pages = {273 -- 280}, year = {2006}, language = {de} } @incollection{UlberMufflerTippkoetteretal.2011, author = {Ulber, Roland and Muffler, Kai and Tippk{\"o}tter, Nils and Hirth, Thomas and Sell, Dieter}, title = {Introduction to Renewable Resources in the Chemical Industry}, series = {Renewable raw materials : new feedstocks for the chemical industry}, booktitle = {Renewable raw materials : new feedstocks for the chemical industry}, editor = {Ulber, Roland and Sell, Dieter and Hirth, Thomas}, edition = {1. Auflage}, publisher = {Wiley-VCH-Verlag}, address = {Weinheim}, isbn = {978-3-527-32548-1}, pages = {1 -- 6}, year = {2011}, language = {de} } @article{WiesenTippkoetterMuffleretal.2014, author = {Wiesen, Sebastian and Tippk{\"o}tter, Nils and Muffler, Kai and Suck, Kirstin and Sohling, Ulrich and Ruf, Nils and Ulber, Roland}, title = {Adsorptive Vorbehandlung von Rohglycerin f{\"u}r die 1,3-Propandiol Fermentation mit Clostridium diolis}, series = {Chemie Ingenieur Technik}, volume = {86}, journal = {Chemie Ingenieur Technik}, number = {1-2}, publisher = {Wiley-VCH}, address = {Weinheim}, doi = {10.1002/cite.201300080}, pages = {129 -- 135}, year = {2014}, abstract = {Bei der Gewinnung von Fetts{\"a}uren aus Pflanzen{\"o}len, z. B. zur Herstellung von Biopolymeren, oder bei der Biodiesel- und Seifenproduktion, f{\"a}llt Glycerin als Nebenprodukt an. Bei der Biokonversion dieses Rohstoffes zu 1,3-Propandiol wird der Produktionsorganismus Clostridium diolis durch Verunreinigungen im Rohglycerin gehemmt. Als inhibierende Substanzen konnten freie Fetts{\"a}uren identifiziert werden. Mithilfe eines adsorptiven Aufarbeitungsverfahrens ist es gelungen, die Fetts{\"a}uren zu entfernen und die Konversionseffizienz zu 1,3-Propandiol zu erh{\"o}hen.}, language = {de} } @article{RothTippkoetter2016, author = {Roth, Jasmine and Tippk{\"o}tter, Nils}, title = {Evaluation of lignocellulosic material for butanol production using enzymatic hydrolysate medium}, series = {Cellulose Chemistry and Technology}, volume = {50}, journal = {Cellulose Chemistry and Technology}, number = {3-4}, publisher = {Editura Academiei Romane}, address = {Bukarest}, pages = {405 -- 410}, year = {2016}, abstract = {Butanol is a promising gasoline additive and platform chemical that can be readily produced via acetone-butanolethanol (ABE) fermentation from pretreated lignocellulosic materials. This article examines lignocellulosic material from beech wood for ABE fermentation, using Clostridium acetobutylicum. First, the utilization of both C₅₋ (xylose) and C₆₋ (glucose) sugars as sole carbon source was investigated in static cultivation, using serum bottles and synthetic medium. The utilization of pentose sugar resulted in a solvent yield of 0.231 g·g_sugar⁻¹, compared to 0.262 g·g_sugar⁻¹ using hexose. Then, the Organosolv pretreated crude cellulose fibers (CF) were enzymatically decomposed, and the resulting hydrolysate medium was analyzed for inhibiting compounds (furans, organic acids, phenolics) and treated with ionexchangers for detoxification. Batch fermentation in a bioreactor using CF hydrolysate medium resulted in a total solvent yield of 0.20 gABE·g_sugar⁻¹.}, language = {en} } @article{BechtSchollmayerMonakhovaetal.2021, author = {Becht, Alexander and Schollmayer, Curd and Monakhova, Yulia and Holzgrabe, Ulrike}, title = {Tracing the origin of paracetamol tablets by near-infrared, mid-infrared, and nuclear magnetic resonance spectroscopy using principal component analysis and linear discriminant analysis}, series = {Analytical and Bioanalytical Chemistry}, volume = {413}, journal = {Analytical and Bioanalytical Chemistry}, publisher = {Springer Nature}, issn = {1618-2650}, doi = {10.1007/s00216-021-03249-z}, pages = {3107 -- 3118}, year = {2021}, abstract = {Most drugs are no longer produced in their own countries by the pharmaceutical companies, but by contract manufacturers or at manufacturing sites in countries that can produce more cheaply. This not only makes it difficult to trace them back but also leaves room for criminal organizations to fake them unnoticed. For these reasons, it is becoming increasingly difficult to determine the exact origin of drugs. The goal of this work was to investigate how exactly this is possible by using different spectroscopic methods like nuclear magnetic resonance and near- and mid-infrared spectroscopy in combination with multivariate data analysis. As an example, 56 out of 64 different paracetamol preparations, collected from 19 countries around the world, were chosen to investigate whether it is possible to determine the pharmaceutical company, manufacturing site, or country of origin. By means of suitable pre-processing of the spectra and the different information contained in each method, principal component analysis was able to evaluate manufacturing relationships between individual companies and to differentiate between production sites or formulations. Linear discriminant analysis showed different results depending on the spectral method and purpose. For all spectroscopic methods, it was found that the classification of the preparations to their manufacturer achieves better results than the classification to their pharmaceutical company. The best results were obtained with nuclear magnetic resonance and near-infrared data, with 94.6\%/99.6\% and 98.7/100\% of the spectra of the preparations correctly assigned to their pharmaceutical company or manufacturer.}, language = {en} } @article{LindnerBurgerRutledgeetal.2022, author = {Lindner, Simon and Burger, Ren{\´e} and Rutledge, Douglas N. and Do, Xuan Tung and Rumpf, Jessica and Diehl, Bernd W. K. and Schulze, Margit and Monakhova, Yulia}, title = {Is the calibration transfer of multivariate calibration models between high- and low-field NMR instruments possible? A case study of lignin molecular weight}, series = {Analytical chemistry}, volume = {94}, journal = {Analytical chemistry}, number = {9}, publisher = {ACS Publications}, address = {Washington, DC}, isbn = {1520-6882}, doi = {10.1021/acs.analchem.1c05125}, pages = {3997 -- 4004}, year = {2022}, abstract = {Although several successful applications of benchtop nuclear magnetic resonance (NMR) spectroscopy in quantitative mixture analysis exist, the possibility of calibration transfer remains mostly unexplored, especially between high- and low-field NMR. This study investigates for the first time the calibration transfer of partial least squares regressions [weight average molecular weight (Mw) of lignin] between high-field (600 MHz) NMR and benchtop NMR devices (43 and 60 MHz). For the transfer, piecewise direct standardization, calibration transfer based on canonical correlation analysis, and transfer via the extreme learning machine auto-encoder method are employed. Despite the immense resolution difference between high-field and low-field NMR instruments, the results demonstrate that the calibration transfer from high- to low-field is feasible in the case of a physical property, namely, the molecular weight, achieving validation errors close to the original calibration (down to only 1.2 times higher root mean square errors). These results introduce new perspectives for applications of benchtop NMR, in which existing calibrations from expensive high-field instruments can be transferred to cheaper benchtop instruments to economize.}, language = {en} } @article{AboulnagaPinkenburgSchiffelsetal.2013, author = {Aboulnaga, El-Hussiny and Pinkenburg, Olaf and Schiffels, Johannes and El-Refai, Ahmed and Buckel, Wolfgang and Selmer, Thorsten}, title = {Butyrate production in Escherichia coli: Exploitation of an oxygen tolerant bifurcating butyryl-CoA dehydrogenase/electron transferring flavoprotein complex from Clostridium difficile}, series = {Journal of bacteriology. June 14, 2013}, journal = {Journal of bacteriology. June 14, 2013}, issn = {1098-5530 (E-Journal) ; 0021-9193 (Print)}, pages = {Epub ahead of print}, year = {2013}, language = {de} } @article{AboulnagaZouSelmeretal.2018, author = {Aboulnaga, Elhussiny A. and Zou, Huibin and Selmer, Thorsten and Xian, Mo}, title = {Development of a plasmid-based, tunable, tolC-derived expression system for application in Cupriavidus necator H16}, series = {Journal of Biotechnology}, volume = {274}, journal = {Journal of Biotechnology}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0168-1656}, doi = {10.1016/j.jbiotec.2018.03.007}, pages = {15 -- 27}, year = {2018}, abstract = {Cupriavidus necator H16 gains increasing attention in microbial research and biotechnological application due to its diverse metabolic features. Here we present a tightly controlled gene expression system for C. necator including the pBBR1-vector that contains hybrid promoters originating from C. necator native tolC-promoter in combination with a synthetic tetO-operator. The expression of the reporter gene from these plasmids relies on the addition of the exogenous inducer doxycycline (dc). The novel expression system offers a combination of advantageous features as; (i) high and dose-dependent recombinant protein production, (ii) tight control with a high dynamic range (On/Off ratio), which makes it applicable for harmful pathways or for toxic protein production, (iii) comparable cheap inducer (doxycycline, dc), (iv) effective at low inducer concentration, that makes it useful for large scale application, (v) rapid, diffusion controlled induction, and (vi) the inducer does not interfere within the cell metabolism. As applications of the expression system in C. necator H16, the growth ability on glycerol was enhanced by constitutively expressing the E. coli glpk gene-encoding for glycerol kinase. Likewise, we used the system to overcome the expression toxicity of mevalonate pathway in C. necator H16. With this system, the mevalonate-genes were successfully introduced in the host and the recombinant strains could produce about 200 mg/l mevalonate.}, language = {en} } @article{AggarwalDhimanKumaretal.2012, author = {Aggarwal, Pranav and Dhiman, Shashi K. and Kumar, G. and Scherer, Ulrich W. and Singla, M. L. and Srivastava, Alok}, title = {Optical study of poly(ethyleneterephthalate) modified by different ionizing radiation dose}, series = {Indian Journal of Pure and Applied Physics}, volume = {50}, journal = {Indian Journal of Pure and Applied Physics}, number = {2}, issn = {0019-5596}, pages = {129 -- 132}, year = {2012}, abstract = {Thin films of poly(ethyleneterephthalate) [PET]were exposed to radiation dose ranging from 10 to 30 kGy by using gamma rays in the range 12.8-177.8 MGy using swift light ions of hydrogen. There was no effect of the radiation dose on the optical behaviour of PET as a result of exposure to radiation dose up to 30 kGy brought about by gamma rays but a significant decrease in the optical band gap values was observed when PET was exposed to swift light ions of hydrogen. The data obtained are discussed in terms of optical studies carried out on PET using swift heavy ions.}, language = {en} } @article{SrivastavaSinghAggarwaletal.2010, author = {Srivastava, Alok and Singh, Virendra and Aggarwal, Pranav and Schneeweiss, F. and Scherer, Ulrich W. and Friedrich, W.}, title = {Optical studies of insulating polymers for radiation dose monitoring}, series = {Indian Journal of Pure \& Applied Physics}, volume = {48}, journal = {Indian Journal of Pure \& Applied Physics}, number = {11}, isbn = {0019-5596}, pages = {782 -- 786}, year = {2010}, language = {en} } @misc{StaubTippkoetterSucketal.2010, author = {Staub, C. and Tippk{\"o}tter, Nils and Suck, K. and Sohling, U. and Ulber, Roland}, title = {Chromatographische Aufarbeitung von Molkekonzentrat mittels mineralischer Granulate}, series = {Chemie Ingenieur Technik}, volume = {82}, journal = {Chemie Ingenieur Technik}, number = {9}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201050322}, pages = {1588 -- 1589}, year = {2010}, abstract = {Molke f{\"a}llt im Rahmen der K{\"a}seherstellung allein in Deutschland in Mengen von {\"u}ber 11 Mio. Tonnen j{\"a}hrlich an. Dieses Nebenprodukt wurde trotz seines Reichtums an Milchzucker und Proteinen lange Zeit kaum industriell weiterverarbeitet und stellte ein bedeutendes Problem bei der Abwasserreinigung dar. Derzeit kommen meist kosten- und reinigungsintensive Membranfiltrationsverfahren bei der Auftrennung von Molke in ihre Hauptkomponenten Lactose und Molkenprotein zum Einsatz. Die Produkte finden vorwiegend in der Nahrungsmittelindustrie Anwendung als S{\"u}ßungsmittel, Proteinzusatz oder Texturbildner. Die Mehrheit des Proteins wird dabei als Konzentrat bzw. Proteinpulver verarbeitet. Wegen der antibakteriellen, antiviralen und weiteren wertvollen physiologischen Eigenschaften der Molkeproteine stellt eine weitere Aufreinigung der einzelnen Molkeproteine f{\"u}r die pharmazeutische Industrie einen naheliegenden zus{\"a}tzlichen Wertsch{\"o}pfungsschritt dar. In Kooperation mit der S{\"u}d Chemie AG wurde damit begonnen, ein Verfahren zu entwickeln, das kosteng{\"u}nstige mineralische Adsorbentien verwendet. Bisher konnte die Abtrennung von Lactose von den Molkenproteinen aus verd{\"u}nntem Molkekonzentrat in einem Verfahrensschritt ohne Vorbehandlung des Rohstoffs erfolgreich realisiert werden. Aktuelle Arbeiten besch{\"a}ftigen sich mit der Verbesserung der Proteinbindekapazit{\"a}tund chromatographischen Proteinauftrennung sowie dem Upscaling zum direkten Einsatz von Molkekonzentrat ohne Vorverd{\"u}nnung.}, language = {de} }