@article{RamoshabaHuismanLammertynetal.2020, author = {Ramoshaba, Nthai E. and Huisman, Hugo W. and Lammertyn, Leandi and Kotliar, Konstantin and Schutte, Aletta E. and Smith, Wayne}, title = {Retinal microvasculature and masked hypertension in young adults: the African-PREDICT study}, series = {Hypertension Research}, journal = {Hypertension Research}, number = {43}, publisher = {Springer Nature}, address = {Osaka}, issn = {1348-4214}, doi = {10.1038/s41440-020-0487-0}, pages = {1231 -- 1238}, year = {2020}, abstract = {Masked hypertension is known to induce microvascular complications. However, it is unclear whether early microvascular changes are already occurring in young, otherwise healthy adults. We therefore investigated whether retinal microvascular calibers and acute responses to a flicker stimulus are related to masked hypertension. We used the baseline data of 889 participants aged 20-30 years who were taking part in the African Prospective study on the Early Detection and Identification of Cardiovascular Disease and Hypertension. Clinic and 24-h ambulatory blood pressure were measured. The central retinal artery equivalent (CRAE) and central retinal vein equivalent were calculated from fundus images, and retinal vessel dilation was determined in response to flicker light-induced provocation. A smaller CRAE was observed in those with masked hypertension vs. those with normotension (157.1 vs. 161.2 measuring units, P < 0.001). In forward multivariable-adjusted regression analysis, only CRAE was negatively related to masked hypertension [adjusted R² = 0.267, β = -0.097 (95\% CI = -0.165; -0.029), P = 0.005], but other retinal microvascular parameters were not associated with masked hypertension. In multivariable logistic regression analyses, masked hypertension [OR = 2.333, (95\% CI = 1.316; 4.241), P = 0.004] was associated with a narrower CRAE. In young healthy adults, masked hypertension was associated with retinal arteriolar narrowing, thereby reflecting early microvascular alterations known to predict cardiovascular outcomes in later life.}, language = {en} } @article{KotliarHanssenEberhardtetal.2013, author = {Kotliar, Konstantin and Hanssen, Henner and Eberhardt, Karla and Vilser, Walthard and Schmaderer, Christoph and Halle, Martin and Heemann, Uwe and Baumann, M.}, title = {Retinal pulse wave velocity in young male normotensive and mildly hypertensive subjects}, series = {Microcirculation}, journal = {Microcirculation}, publisher = {Wiley}, address = {Malden}, issn = {1549-8719}, year = {2013}, language = {en} } @article{AlbannaConzenWeissetal.2016, author = {Albanna, W. and Conzen, C. and Weiss, M. and Clusmann, H. and Fuest, M. and Mueller, M. and Brockmann, M.A. and Vilser, W. and Schmidt-Trucks{\"a}ss, A. and Hoellig, A. and Seiz, M. and Thom{\´e}, C. and Kotliar, Konstantin and Schubert, G.A.}, title = {Retinal Vessel Analysis (RVA) in the context of subarachnoid hemorrhage: A proof of concept study}, series = {PLoS ONE}, volume = {11}, journal = {PLoS ONE}, number = {7}, publisher = {PLOS}, address = {San Francisco}, issn = {1932-6203}, doi = {10.1371/journal.pone.0158781}, pages = {13 Seiten}, year = {2016}, abstract = {Background Timely detection of impending delayed cerebral ischemia after subarachnoid hemorrhage (SAH) is essential to improve outcome, but poses a diagnostic challenge. Retinal vessels as an embryological part of the intracranial vasculature are easily accessible for analysis and may hold the key to a new and non-invasive monitoring technique. This investigation aims to determine the feasibility of standardized retinal vessel analysis (RVA) in the context of SAH. Methods In a prospective pilot study, we performed RVA in six patients awake and cooperative with SAH in the acute phase (day 2-14) and eight patients at the time of follow-up (mean 4.6±1.7months after SAH), and included 33 age-matched healthy controls. Data was acquired using a manoeuvrable Dynamic Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and neurovascular coupling. Results Image quality was satisfactory in the majority of cases (93.3\%). In the acute phase after SAH, retinal arteries were significantly dilated when compared to the control group (124.2±4.3MU vs 110.9±11.4MU, p<0.01), a difference that persisted to a lesser extent in the later stage of the disease (122.7±17.2MU, p<0.05). Testing for neurovascular coupling showed a trend towards impaired primary vasodilation and secondary vasoconstriction (p = 0.08, p = 0.09 resp.) initially and partial recovery at the time of follow-up, indicating a relative improvement in a time-dependent fashion. Conclusion RVA is technically feasible in patients with SAH and can detect fluctuations in vessel diameter and autoregulation even in less severely affected patients. Preliminary data suggests potential for RVA as a new and non-invasive tool for advanced SAH monitoring, but clinical relevance and prognostic value will have to be determined in a larger cohort.}, language = {en} } @article{SmithKotliarLammertynetal.2020, author = {Smith, Wayne and Kotliar, Konstantin and Lammertyn, Leandi and Ramoshaba, Nthai E. and Vilser, Walthard and Huisman, Hugo W. and Schutte, Aletta E.}, title = {Retinal vessel caliber and caliber responses in true normotensive black and white adults: The African-PREDICT study}, series = {Microvascular Research}, volume = {128}, journal = {Microvascular Research}, number = {Article 103937}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0026-2862}, doi = {10.1016/j.mvr.2019.103937}, year = {2020}, abstract = {Purpose Globally, a detrimental shift in cardiovascular disease risk factors and a higher mortality level are reported in some black populations. The retinal microvasculature provides early insight into the pathogenesis of systemic vascular diseases, but it is unclear whether retinal vessel calibers and acute retinal vessel functional responses differ between young healthy black and white adults. Methods We included 112 black and 143 white healthy normotensive adults (20-30 years). Retinal vessel calibers (central retinal artery and vein equivalent (CRAE and CRVE)) were calculated from retinal images and vessel caliber responses to flicker light induced provocation (FLIP) were determined. Additionally, ambulatory blood pressure (BP), anthropometry and blood samples were collected. Results The groups displayed similar 24 h BP profiles and anthropometry (all p > .24). Black participants demonstrated a smaller CRAE (158 ± 11 vs. 164 ± 11 MU, p < .001) compared to the white group, whereas CRVE was similar (p = .57). In response to FLIP, artery maximal dilation was greater in the black vs. white group (5.6 ± 2.1 vs. 3.3 ± 1.8\%; p < .001). Conclusions Already at a young age, healthy black adults showed narrower retinal arteries relative to the white population. Follow-up studies are underway to show if this will be related to increased risk for hypertension development. The reason for the larger vessel dilation responses to FLIP in the black population is unclear and warrants further investigation.}, language = {en} } @article{KotliarVilserNageletal.2004, author = {Kotliar, Konstantin and Vilser, Walthatd and Nagel, Edgar and Lanzl, Ines M.}, title = {Retinal vessel reaction in response to chromatic flickering light / Kotliar, Konstantin E. ; Vilser, Walthard ; Nagel, Edgar ; Lanzl, Ines M.}, series = {Graefe's Archive for Clinical and Experimental Ophthalmology. 242 (2004), H. 5}, journal = {Graefe's Archive for Clinical and Experimental Ophthalmology. 242 (2004), H. 5}, publisher = {-}, isbn = {1435-702X}, pages = {377 -- 392}, year = {2004}, language = {en} } @article{NeumaierKotliarHaerenetal.2021, author = {Neumaier, Felix and Kotliar, Konstantin and Haeren, Roel Hubert Louis and Temel, Yasin and L{\"u}ke, Jan Niklas and Seyam, Osama and Lindauer, Ute and Clusmann, Hans and Hescheler, J{\"u}rgen and Schubert, Gerrit Alexander and Schneider, Toni and Albanna, Walid}, title = {Retinal Vessel Responses to Flicker Stimulation Are Impaired in Ca v 2.3-Deficient Mice—An in- vivo Evaluation Using Retinal Vessel Analysis (RVA)}, series = {Frontiers in Neurology}, volume = {12}, journal = {Frontiers in Neurology}, publisher = {Frontiers}, doi = {10.3389/fneur.2021.659890}, pages = {1 -- 11}, year = {2021}, language = {en} } @inproceedings{RendonDieckmannWeidleetal.2018, author = {Rendon, Carlos and Dieckmann, Simon and Weidle, Mathias and Dersch, J{\"u}rgen and Teixeira Boura, Cristiano Jos{\´e} and Polklas, Thomas and Kuschel, Marcus and Herrmann, Ulf}, title = {Retrofitting of existing parabolic trough collector power plants with molten salt tower systems}, series = {AIP Conference Proceedings}, volume = {2033}, booktitle = {AIP Conference Proceedings}, number = {1}, doi = {10.1063/1.5067030}, pages = {030014-1 -- 030014-8}, year = {2018}, language = {en} } @article{RhodenBallGrajewskietal.2023, author = {Rhoden, Imke and Ball, Christopher Stephen and Grajewski, Matthias and Kuckshinrich, Wilhelm}, title = {Reverse engineering of stakeholder preferences - A multi-criteria assessment of the German passenger car sector}, series = {Renewable and Sustainable Energy Reviews}, volume = {181}, journal = {Renewable and Sustainable Energy Reviews}, number = {July 2023}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1364-0321}, doi = {10.1016/j.rser.2023.113352}, pages = {Article number: 113352}, year = {2023}, abstract = {Germany is a frontrunner in setting frameworks for the transition to a low-carbon system. The mobility sector plays a significant role in this shift, affecting different people and groups on multiple levels. Without acceptance from these stakeholders, emission targets are out of reach. This research analyzes how the heterogeneous preferences of various stakeholders align with the transformation of the mobility sector, looking at the extent to which the German transformation paths are supported and where stakeholders are located. Under the research objective of comparing stakeholders' preferences to identify which car segments require additional support for a successful climate transition, a status quo of stakeholders and car performance criteria is the foundation for the analysis. Stakeholders' hidden preferences hinder the derivation of criteria weightings from stakeholders; therefore, a ranking from observed preferences is used. This study's inverse multi-criteria decision analysis means that weightings can be predicted and used together with a recalibrated performance matrix to explore future preferences toward car segments. Results show that stakeholders prefer medium-sized cars, with the trend pointing towards the increased potential for alternative propulsion technologies and electrified vehicles. These insights can guide the improved targeting of policy supporting the energy and mobility transformation. Additionally, the method proposed in this work can fully handle subjective approaches while incorporating a priori information. A software implementation of the proposed method completes this work and is made publicly available.}, language = {en} } @article{SeiblerKleinriddersKueterLuksetal.2007, author = {Seibler, Jost and Kleinridders, Andre and K{\"u}ter-Luks, Birgit and Niehaves, Sandra and Br{\"u}ning, Jens C. and Schwenk, Frieder}, title = {Reversible gene knockdown in mice using a tight, inducible shRNA expression system}, series = {Nucleic Acids Research}, volume = {35}, journal = {Nucleic Acids Research}, number = {7}, issn = {1362-4962}, doi = {10.1093/nar/gkm122}, pages = {e54}, year = {2007}, language = {en} } @article{KaemperPappasHopster1990, author = {K{\"a}mper, Klaus-Peter and Pappas, D. P. and Hopster, H.}, title = {Reversible transition between perpendicular and in-plane magnetization in ultrathin films. Pappas, D. P.; K{\"a}mper, K.-P.; Hopster, H.}, series = {Physical Review Letters. 64 (1990), H. 26}, journal = {Physical Review Letters. 64 (1990), H. 26}, isbn = {1079-7114}, pages = {3179 -- 3182}, year = {1990}, language = {en} } @article{HagemannHennings1981, author = {Hagemann, Hans-J{\"u}rgen and Hennings, D.}, title = {Reversible Weight change of acceptor-doped BaTiO3. Hagemann, H. J.; Hennings, D.}, series = {Journal of the American Ceramic Society. 64 (1981)}, journal = {Journal of the American Ceramic Society. 64 (1981)}, isbn = {0002-7820}, pages = {590 -- 594}, year = {1981}, language = {en} } @article{SattlerRoegerSchwarzboezletal.2020, author = {Sattler, Johannes Christoph and R{\"o}ger, Marc and Schwarzb{\"o}zl, Peter and Buck, Reiner and Macke, Ansgar and Raeder, Christian and G{\"o}ttsche, Joachim}, title = {Review of heliostat calibration and tracking control methods}, series = {Solar Energy}, volume = {207}, journal = {Solar Energy}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.solener.2020.06.030}, pages = {110 -- 132}, year = {2020}, abstract = {Large scale central receiver systems typically deploy between thousands to more than a hundred thousand heliostats. During solar operation, each heliostat is aligned individually in such a way that the overall surface normal bisects the angle between the sun's position and the aim point coordinate on the receiver. Due to various tracking error sources, achieving accurate alignment ≤1 mrad for all the heliostats with respect to the aim points on the receiver without a calibration system can be regarded as unrealistic. Therefore, a calibration system is necessary not only to improve the aiming accuracy for achieving desired flux distributions but also to reduce or eliminate spillage. An overview of current larger-scale central receiver systems (CRS), tracking error sources and the basic requirements of an ideal calibration system is presented. Leading up to the main topic, a description of general and specific terms on the topics heliostat calibration and tracking control clarifies the terminology used in this work. Various figures illustrate the signal flows along various typical components as well as the corresponding monitoring or measuring devices that indicate or measure along the signal (or effect) chain. The numerous calibration systems are described in detail and classified in groups. Two tables allow the juxtaposition of the calibration methods for a better comparison. In an assessment, the advantages and disadvantages of individual calibration methods are presented.}, language = {en} } @misc{TippkoetterUlber2012, author = {Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Rezension zu: Encyclopedia of Industrial Biotechnology, Vol. 1-7. By MC Flickinger.}, series = {Chemie Ingenieur Technik}, volume = {6}, journal = {Chemie Ingenieur Technik}, number = {84}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201290052}, pages = {936}, year = {2012}, language = {en} } @article{OrzadaMaderwaldPoseretal.2010, author = {Orzada, Stephan and Maderwald, Stefan and Poser, Benedikt Andreas and Bitz, Andreas and Quick, Harald H. and Ladd, Mark E.}, title = {RF excitation using time interleaved acquisition of modes (TIAMO) to address B1 inhomogeneity in high-field MRI}, series = {Magnetic Resonance in Medicine}, volume = {64}, journal = {Magnetic Resonance in Medicine}, number = {2}, publisher = {Wiley-Liss}, address = {New York}, issn = {1522-2594}, doi = {10.1002/mrm.22527}, pages = {327 -- 333}, year = {2010}, abstract = {As the field strength and, therefore, the operational frequency in MRI is increased, the wavelength approaches the size of the human head/body, resulting in wave effects, which cause signal decreases and dropouts. Several multichannel approaches have been proposed to try to tackle these problems, including RF shimming, where each element in an array is driven by its own amplifier and modulated with a certain (constant) amplitude and phase relative to the other elements, and Transmit SENSE, where spatially tailored RF pulses are used. In this article, a relatively inexpensive and easy to use imaging scheme for 7 Tesla imaging is proposed to mitigate signal voids due to B1 field inhomogeneity. Two time-interleaved images are acquired using a different excitation mode for each. By forming virtual receive elements, both images are reconstructed together using GRAPPA to achieve a more homogeneous image, with only small SNR and SAR penalty in head and body imaging at 7 Tesla.}, language = {en} } @article{HansenBitzStreckert1999, author = {Hansen, Volkert W. and Bitz, Andreas and Streckert, Joachim R.}, title = {RF Exposure of Biological Systems in Radial Waveguides}, series = {IEEE Transactions on Electromagnetic Compatibility}, volume = {41}, journal = {IEEE Transactions on Electromagnetic Compatibility}, number = {4}, issn = {1558-187X}, doi = {10.1109/15.809852}, pages = {487 -- 493}, year = {1999}, language = {en} } @inproceedings{BitzStreckertHansenetal.2000, author = {Bitz, Andreas and Streckert, J. and Hansen, V.W. and Buschmann, J.}, title = {RF exposure of non restrained animals in an overmoded radial waveguide}, series = {22nd BEMS Annual Meeting, Munich, Germany, 2000}, booktitle = {22nd BEMS Annual Meeting, Munich, Germany, 2000}, publisher = {Bioelectromagnetics Society}, address = {Frederick, MD}, pages = {63}, year = {2000}, language = {en} } @inproceedings{AllalBannisterBuismanetal.2022, author = {Allal, D. and Bannister, R. and Buisman, K. and Capriglione, D. and Di Capua, G. and Garc{\´i}a-Patr{\´o}n, M. and Gatzweiler, Thomas and Gellersen, F. and Harzheim, Thomas and Heuermann, Holger and Hoffmann, J. and Izbrodin, A. and Kuhlmann, K. and Lahbacha, K. and Maffucci, A. and Miele, G. and Mubarak, F. and Salter, M. and Pham, T.D. and Sayegh, A. and Singh, D. and Stein, F. and Zeier, M.}, title = {RF measurements for future communication applications: an overview}, series = {2022 IEEE International Symposium on Measurements \& Networking (M\&N)}, booktitle = {2022 IEEE International Symposium on Measurements \& Networking (M\&N)}, publisher = {IEEE}, isbn = {978-1-6654-8362-9}, issn = {2639-5061}, doi = {10.1109/MN55117.2022.9887740}, pages = {1 -- 6}, year = {2022}, abstract = {In this paper research activities developed within the FutureCom project are presented. The project, funded by the European Metrology Programme for Innovation and Research (EMPIR), aims at evaluating and characterizing: (i) active devices, (ii) signal- and power integrity of field programmable gate array (FPGA) circuits, (iii) operational performance of electronic circuits in real-world and harsh environments (e.g. below and above ambient temperatures and at different levels of humidity), (iv) passive inter-modulation (PIM) in communication systems considering different values of temperature and humidity corresponding to the typical operating conditions that we can experience in real-world scenarios. An overview of the FutureCom project is provided here, then the research activities are described.}, language = {en} } @article{FiedlerLaddBitz2017, author = {Fiedler, Thomas M. and Ladd, Mark E. and Bitz, Andreas}, title = {RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus temperature limits}, series = {Medical Physics}, volume = {44}, journal = {Medical Physics}, number = {1}, doi = {10.1002/mp.12034}, pages = {143 -- 157}, year = {2017}, language = {en} } @inproceedings{BitzKobusScheenenetal.2013, author = {Bitz, Andreas and Kobus, Thiele and Scheenen, Tom W. J. and Ladd, Mark E.}, title = {RF Safety of the Combination of a 31P Tx/Rx Endorectal Coil \& a 1H Tx/Rx Body Array for 31P MRSI of the Prostate at 7T (311.)}, series = {20th Annual ISMRM scientific meeting and exhibition 2012 : Melbourne, Australia, 5 - 11 May 2012}, booktitle = {20th Annual ISMRM scientific meeting and exhibition 2012 : Melbourne, Australia, 5 - 11 May 2012}, number = {Volume 1}, publisher = {Curran}, address = {Red Hook, NY}, isbn = {978-1-62276-943-8}, issn = {1545-4428}, pages = {311}, year = {2013}, language = {en} } @article{KurulganDemirciDemirciLinderetal.2012, author = {Kurulgan Demirci, Eylem and Demirci, Taylan and Linder, Peter and Trzewik, J{\"u}rgen and Gierkowski, Jessica Ricarda and Gossmann, Matthias and Kayser, Peter and Porst, Dariusz and Digel, Ilya and Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l}, title = {rhAPC reduces the endothelial cell permeability via a decrease of contractile tensions induced by endothelial cells}, series = {Journal of Bioscience and Bioengineering}, volume = {113}, journal = {Journal of Bioscience and Bioengineering}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1347-4421}, doi = {10.1016/j.jbiosc.2012.03.019}, pages = {212 -- 219}, year = {2012}, abstract = {All cells generate contractile tension. This strain is crucial for mechanically controlling the cell shape, function and survival. In this study, the CellDrum technology quantifying cell's (the cellular) mechanical tension on a pico-scale was used to investigate the effect of lipopolysaccharide (LPS) on human aortic endothelial cell (HAoEC) tension. The LPS effect during gram-negative sepsis on endothelial cells is cell contraction causing endothelium permeability increase. The aim was to finding out whether recombinant activated protein C (rhAPC) would reverse the endothelial cell response in an in-vitro sepsis model. In this study, the established in-vitro sepsis model was confirmed by interleukin 6 (IL-6) levels at the proteomic and genomic levels by ELISA, real time-PCR and reactive oxygen species (ROS) activation by florescence staining. The thrombin cellular contraction effect on endothelial cells was used as a positive control when the CellDrum technology was applied. Additionally, the Ras homolog gene family, member A (RhoA) mRNA expression level was checked by real time-PCR to support contractile tension results. According to contractile tension results, the mechanical predominance of actin stress fibers was a reason of the increased endothelial contractile tension leading to enhanced endothelium contractility and thus permeability enhancement. The originality of this data supports firstly the basic measurement principles of the CellDrum technology and secondly that rhAPC has a beneficial effect on sepsis influenced cellular tension. The technology presented here is promising for future high-throughput cellular tension analysis that will help identify pathological contractile tension responses of cells and prove further cell in-vitro models.}, language = {en} }