@article{KellerRathBruckmannetal.2020, author = {Keller, Johannes and Rath, Volker and Bruckmann, Johanna and Mottaghy, Darius and Clauser, Christoph and Wolf, Andreas and Seidler, Ralf and B{\"u}cker, H. Martin and Klitzsch, Norbert}, title = {SHEMAT-Suite: An open-source code for simulating flow, heat and species transport in porous media}, series = {SoftwareX}, volume = {12}, journal = {SoftwareX}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2352-7110}, doi = {10.1016/j.softx.2020.100533}, pages = {9}, year = {2020}, abstract = {SHEMAT-Suite is a finite-difference open-source code for simulating coupled flow, heat and species transport in porous media. The code, written in Fortran-95, originates from geoscientific research in the fields of geothermics and hydrogeology. It comprises: (1) a versatile handling of input and output, (2) a modular framework for subsurface parameter modeling, (3) a multi-level OpenMP parallelization, (4) parameter estimation and data assimilation by stochastic approaches (Monte Carlo, Ensemble Kalman filter) and by deterministic Bayesian approaches based on automatic differentiation for calculating exact (truncation error-free) derivatives of the forward code.}, language = {en} } @inproceedings{BitzStreckertHansenetal.2001, author = {Bitz, Andreas and Streckert, J. and Hansen, V.W. and Stogbauer, F.}, title = {Shielded RF-exposure system with an integrated LF-measuring system for in vitro experiments with cell-layers}, series = {Proceedings of the Ebea 2001 : 5th International Congress of the European Bioelectromagnetics Association (Ebea) ; 6-8 September 2001, Marina Congress Center, Helsinki, Finland}, booktitle = {Proceedings of the Ebea 2001 : 5th International Congress of the European Bioelectromagnetics Association (Ebea) ; 6-8 September 2001, Marina Congress Center, Helsinki, Finland}, editor = {Hietanen, Maila and Jokela, Kari and Juutilainen, Jukka and Työterveyslaitos,}, publisher = {Finnish Institute of Occupational Health}, address = {Helsinki}, isbn = {9789518024401}, pages = {67 -- 68}, year = {2001}, language = {en} } @article{KernZischankHeidleretal.1998, author = {Kern, Alexander and Zischank, Wolfgang J. and Heidler, Fridolin and Wiesinger, J. [u.a.]}, title = {Shielding effectiveness of reinforced concrete cable ducts carrying partial lightning currents}, series = {Conference proceedings : 14th - 18th September 1998, [Burlington Hotel, Birmingham, United Kingdom] / organised by: School of Engineering and Advanced Technology, Staffordshire University, United Kingdom}, journal = {Conference proceedings : 14th - 18th September 1998, [Burlington Hotel, Birmingham, United Kingdom] / organised by: School of Engineering and Advanced Technology, Staffordshire University, United Kingdom}, address = {Birmingham}, year = {1998}, language = {en} } @article{ReisgenSchleserMokrovetal.2010, author = {Reisgen, Uwe and Schleser, Markus and Mokrov, Oleg and Ahmed, Essam}, title = {Shielding gas influences on laser weldability of tailored blanks of advanced automotive steels}, series = {Applied surface science}, volume = {257}, journal = {Applied surface science}, number = {5}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0169-4332 (E-Journal); 0169-4332 (Print)}, doi = {10.1016/j.apsusc.2010.08.042}, pages = {1401 -- 1406}, year = {2010}, abstract = {The effects of shielding gas types and flow rates on CO2 laser weldability of DP600/TRIP700 steel sheets were studied in this work. The evaluated shielding gases were helium (He), argon (Ar) and different mixtures of He and Ar. Weld penetration, tensile strength and formability (Erichsen test) of laser welds were found to be strongly dependent upon the shielding gas types. The ability of shielding gas in removing plasma plume and thus increasing weld penetration is believed to be closely related to ionization potential and atomic weight which determine the period of plasma formation and disappearance. It was found that the higher helium shielding gas flow rate, the deeper weld penetration and the lower weld width.}, language = {en} } @inproceedings{HavermannSeilerHenning2010, author = {Havermann, Marc and Seiler, F. and Henning, P.}, title = {Shock Tunnel Experiments and CFD Simulation of Lateral Jet Interaction in Hypersonic Flows}, series = {New Results in Numerical and Experimental Fluid Mechanics VII; Contributions to the 16th STAB/DGLR Symposium Aachen, Germany 2008}, booktitle = {New Results in Numerical and Experimental Fluid Mechanics VII; Contributions to the 16th STAB/DGLR Symposium Aachen, Germany 2008}, editor = {Dillmann, Andreas and Heller, Gerd and Klaas, Michael and Kreplin, Hans-Peter and Nitsche, Wolfgang and Schr{\"o}der, Wolfgang}, publisher = {Springer}, address = {Berlin}, isbn = {9783642142437}, doi = {10.1007/978-3-642-14243-7_45}, pages = {365 -- 372}, year = {2010}, language = {en} } @article{HavermannEndeSeileretal.2005, author = {Havermann, Marc and Ende, H. and Seiler, F. and Schwenzer, M.}, title = {Shock tunnel measurement of the interaction amplification factor for a hot gas side jet in a supersonic cross flow / Havermann, M. ; Ende, H. ; Seiler, F. ; Schwenzer, M.}, series = {Shock Waves : Proceedings of the 24th International Symposium on Shock Waves Beijing, China July 11-16, 2004 / edited by Z. Jiang}, journal = {Shock Waves : Proceedings of the 24th International Symposium on Shock Waves Beijing, China July 11-16, 2004 / edited by Z. Jiang}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-540-22497-6}, pages = {113 -- 118}, year = {2005}, language = {en} } @book{Havermann2004, author = {Havermann, Marc}, title = {Shock tunnel measurement of the interaction amplification factor for a hot gas side jet in a supersonic cross-flow : 24th International Symposium on Shock Waves, Beijing, China, July 11 - 16, 2004 / Institut Franco-Allemand de Recherches de Saint-Louis. Havermann, M. ...}, publisher = {ISL}, address = {Saint-Louis}, pages = {6 S. : Ill., graph. Darst.}, year = {2004}, language = {en} } @book{HavermannEndeSchwenzer2002, author = {Havermann, Marc and Ende, Herrybert and Schwenzer, Michael}, title = {Shock tunnel study on the interaction of a lateral jet with a supersonic cross flow : West East High-Speed Flow Field Conference, Marseille, France, April 22 - 26, 2002; axe de recherches 2.14 / Havermann, M.; Ende, H.; Schwenzer, M. Institut Franco-Allemand de Recherches de Saint-Louis}, publisher = {ISL}, address = {Saint-Louis}, pages = {8 S. : Ill., graph. Darst.}, year = {2002}, language = {en} } @article{SchlamannYoonMaderwaldetal.2010, author = {Schlamann, Marc and Yoon, Min-Suk and Maderwald, Stefan and Pietrzyk, Thomas and Bitz, Andreas and Gerwig, Marcus and Forsting, Michael and Ladd, Susanne C. and Ladd, Mark E. and Kastrup, Oliver}, title = {Short term effects of magnetic resonance imaging on excitability of the motor cortex at 1.5T and 7T}, series = {Academic Radiology}, volume = {17}, journal = {Academic Radiology}, number = {3}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1076-6332}, doi = {10.1016/j.acra.2009.10.004}, pages = {277 -- 281}, year = {2010}, abstract = {Rationale and Objectives The increasing spread of high-field and ultra-high-field magnetic resonance imaging (MRI) scanners has encouraged new discussion of the safety aspects of MRI. Few studies have been published on possible cognitive effects of MRI examinations. The aim of this study was to examine whether changes are measurable after MRI examinations at 1.5 and 7 T by means of transcranial magnetic stimulation (TMS). Materials and Methods TMS was performed in 12 healthy, right-handed male volunteers. First the individual motor threshold was specified, and then the cortical silent period (SP) was measured. Subsequently, the volunteers were exposed to the 1.5-T MRI scanner for 63 minutes using standard sequences. The MRI examination was immediately followed by another TMS session. Fifteen minutes later, TMS was repeated. Four weeks later, the complete setting was repeated using a 7-T scanner. Control conditions included lying in the 1.5-T scanner for 63 minutes without scanning and lying in a separate room for 63 minutes. TMS was performed in the same way in each case. For statistical analysis, Wilcoxon's rank test was performed. Results Immediately after MRI exposure, the SP was highly significantly prolonged in all 12 subjects at 1.5 and 7 T. The motor threshold was significantly increased. Fifteen minutes after the examination, the measured value tended toward normal again. Control conditions revealed no significant differences. Conclusion MRI examinations lead to a transient and highly significant alteration in cortical excitability. This effect does not seem to depend on the strength of the static magnetic field.}, language = {en} } @inproceedings{WangMensingGligorevicetal.2008, author = {Wang, W. and Mensing, C. and Gligorevic, Snjezana and Jost, T. and Dammann, A.}, title = {Short term statistical analysis of outdoor to indoor propagation channel for geolocations}, series = {Proceedings of the 13th International OFDM Workshop : (InOWo '08), Aug. 27./28. 2008, Hamburg : Session 3A: Systems concepts}, booktitle = {Proceedings of the 13th International OFDM Workshop : (InOWo '08), Aug. 27./28. 2008, Hamburg : Session 3A: Systems concepts}, organization = {International OFDM Workshop <13, 2008, Hamburg>}, pages = {85 -- 89}, year = {2008}, language = {en} } @article{HacklKahmannWegmannetal.2016, author = {Hackl, Michael and Kahmann, Stephanie Lucina and Wegmann, Kilian and Ries, Christian and Staat, Manfred and M{\"u}ller, Lars-Peter}, title = {Shortening osteotomy of the proximal radius — a treatment option for isolated osteoarthritis of the lateral column of the elbow joint?}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4080-7}, pages = {128 -- 129}, year = {2016}, abstract = {Treatment of posttraumatic osteoarthritis of the radial column of the elbow joint remains a challenging yet common issue. While partial joint replacement leads to high revision rates, radial head excision has shown to severely increase joint instability. Shortening osteotomy of the radius could be an option to decrease the contact pressure of the radiohumeral joint and thereby pain levels without causing valgus instability. Hence, the aim of this biomechanical study was to evaluate the effects of radial shortening on axial load distribution and valgus stability of the elbow joint.}, language = {en} } @article{SchaeferShaoScholletal.1996, author = {Sch{\"a}fer, Horst and Shao, H. and Scholl, H. and Gersch{\"u}tz, J. (u.a.)}, title = {Shubnikov - de Haas Oscillations of a Two - dimensional Electron Gas in a Modulation - Doped Zn0.80Cd0.20Se/ZnS0.06Se 0.94 Single Quantum Well}, series = {Solid State Communications. 100 (1996), H. 11}, journal = {Solid State Communications. 100 (1996), H. 11}, isbn = {0038-1098}, pages = {739}, year = {1996}, language = {en} } @article{MuellerVeggianGonoHaennietal.1978, author = {M{\"u}ller-Veggian, Mattea and Gono, Y. and Haenni, D. R. and Beuscher, H.}, title = {Side bands in ¹⁷² Hf}, series = {Proceedings of the International Conference on Nuclear Structure : Tokyo, Sept. 5 - 10, 1977 / ed. by T. Marumori. - Journal of the Physical Society of Japan ; Vol. 44, 1978 : Suppl.}, journal = {Proceedings of the International Conference on Nuclear Structure : Tokyo, Sept. 5 - 10, 1977 / ed. by T. Marumori. - Journal of the Physical Society of Japan ; Vol. 44, 1978 : Suppl.}, publisher = {Physical Soc. of Japan}, address = {Tokyo}, pages = {866}, year = {1978}, language = {en} } @article{MuellerVeggianBeuscherGonoetal.1977, author = {M{\"u}ller-Veggian, Mattea and Beuscher, H. and Gono, Y. and Lieder, R. M.}, title = {Side bands in ¹⁷² Hf}, series = {Fr{\"u}hjahrstagung ... des Fachausschusses Kernphysik und Hochenergiephysik der DPG (Sektion A: Kernphysik) / Deutsche Physikalische Gesellschaft (1977)}, journal = {Fr{\"u}hjahrstagung ... des Fachausschusses Kernphysik und Hochenergiephysik der DPG (Sektion A: Kernphysik) / Deutsche Physikalische Gesellschaft (1977)}, pages = {940}, year = {1977}, language = {en} } @article{MuellerVeggianHaenniGonoetal.1978, author = {M{\"u}ller-Veggian, Mattea and Haenni, D. R. and Gono, Y. and Beuscher, H.}, title = {Side bands in ¹⁷² Hf}, series = {Annual report 1977 / Institut f{\"u}r Kernphysik Kernforschungsanlage J{\"u}lich}, journal = {Annual report 1977 / Institut f{\"u}r Kernphysik Kernforschungsanlage J{\"u}lich}, publisher = {Verlag des Forschungszentrums J{\"u}lich}, address = {J{\"u}lich}, pages = {43 -- 44}, year = {1978}, language = {en} } @article{MuellerVeggianNeskakisLiederetal.1981, author = {M{\"u}ller-Veggian, Mattea and Neskakis, A. and Lieder, R. M. and Beuscher, H.}, title = {Side-bands in ¹⁸⁰ Os}, series = {International Conference Nuclear and Atomic Physics With Heay Ions : Bucharest, Romania, 9 - 12 June 1981 / European Physcial Society, Nuclear Physics Division ; The Central Institute of Physics, Romania. - (Europhysics Conference abstracts ; Vol. 5 C)}, journal = {International Conference Nuclear and Atomic Physics With Heay Ions : Bucharest, Romania, 9 - 12 June 1981 / European Physcial Society, Nuclear Physics Division ; The Central Institute of Physics, Romania. - (Europhysics Conference abstracts ; Vol. 5 C)}, publisher = {EPS}, address = {[Petit-Lancy]}, pages = {79 -- 80}, year = {1981}, language = {en} } @article{HillenEckenbachQuadfliegetal.1991, author = {Hillen, Walter and Eckenbach, W. and Quadflieg, Peter and Zaengel, Thomas T.}, title = {Signal-to-noise performance of a CsI fluorescent screen}, series = {Medical Imaging V: Image physics}, journal = {Medical Imaging V: Image physics}, isbn = {0-8194-0538-8}, pages = {120 -- 131}, year = {1991}, language = {en} } @article{HillenSchmittBockemuehl1995, author = {Hillen, Walter and Schmitt, W. and Bockem{\"u}hl, J.}, title = {Signal-to-Noise Performance of a digital dental X-ray Detector}, series = {Computer assisted radiology : proceedings of the International Symposium on Computer and Communication Systems for Image Guided Diagnosis and Therapy / CAR '95 Berlin, June 21 - 24, 1995. Ed. by H. U. Lemke}, journal = {Computer assisted radiology : proceedings of the International Symposium on Computer and Communication Systems for Image Guided Diagnosis and Therapy / CAR '95 Berlin, June 21 - 24, 1995. Ed. by H. U. Lemke}, publisher = {Springer}, address = {Berlin [u.a.]}, isbn = {3-540-59177-X}, pages = {LXXIV, 1442 S. : Ill., graph. Darst.}, year = {1995}, language = {en} } @inproceedings{BhattaraiFrotscherStaat2016, author = {Bhattarai, Aroj and Frotscher, Ralf and Staat, Manfred}, title = {Significance of fibre geometry on passive-active response of pelvic muscles to evaluate pelvic dysfunction}, series = {BioMedWomen: Proceedings of the international conference on clinical and bioengineering for women's health}, booktitle = {BioMedWomen: Proceedings of the international conference on clinical and bioengineering for women's health}, editor = {Natal Jorge, Renato}, publisher = {CRC Press}, address = {Boca Raton}, isbn = {978-1-138-02910-1}, pages = {185 -- 188}, year = {2016}, language = {en} } @article{ThomaRavi2019, author = {Thoma, Andreas and Ravi, Sridhar}, title = {Significance of parallel computing on the performance of Digital Image Correlation algorithms in MATLAB}, pages = {1 -- 17}, year = {2019}, abstract = {Digital Image Correlation (DIC) is a powerful tool used to evaluate displacements and deformations in a non-intrusive manner. By comparing two images, one of the undeformed reference state of a specimen and another of the deformed target state, the relative displacement between those two states is determined. DIC is well known and often used for post-processing analysis of in-plane displacements and deformation of specimen. Increasing the analysis speed to enable real-time DIC analysis will be beneficial and extend the field of use of this technique. Here we tested several combinations of the most common DIC methods in combination with different parallelization approaches in MATLAB and evaluated their performance to determine whether real-time analysis is possible with these methods. To reflect improvements in computing technology different hardware settings were also analysed. We found that implementation problems can reduce the efficiency of a theoretically superior algorithm such that it becomes practically slower than a suboptimal algorithm. The Newton-Raphson algorithm in combination with a modified Particle Swarm algorithm in parallel image computation was found to be most effective. This is contrary to theory, suggesting that the inverse-compositional Gauss-Newton algorithm is superior. As expected, the Brute Force Search algorithm is the least effective method. We also found that the correct choice of parallelization tasks is crucial to achieve improvements in computing speed. A poorly chosen parallelisation approach with high parallel overhead leads to inferior performance. Finally, irrespective of the computing mode the correct choice of combinations of integerpixel and sub-pixel search algorithms is decisive for an efficient analysis. Using currently available hardware realtime analysis at high framerates remains an aspiration.}, language = {en} }