@article{BergDemarteauHardtetal.1982, author = {Berg, Georg P. A. and Demarteau, M. and Hardt, Arno and H{\"u}rlimann, Werner and Martin, Siegfried A. and Meissburger, J{\"u}rgen and Oelert, W. and Seyfart, H. and Styczen, B. and K{\"o}hler, M. and Oelrich, I. and Scheerer, J.}, title = {High resolution spectroscopy of 102Ru(d, p)103Ru and 104Ru(p, d)103Ru reactions}, series = {Nuclear Physics A. Vol. 379, iss. 1}, journal = {Nuclear Physics A. Vol. 379, iss. 1}, issn = {1873-1554 (E-Journal); 0375-9474 (Print)}, pages = {93 -- 109}, year = {1982}, language = {en} } @incollection{BechstedtBergHackeretal.1995, author = {Bechstedt, U. and Berg, Georg P. A. and Hacker, Ulrich and Hardt, Arno and H{\"u}rlimann, Werner and Maier, R. and Martin, Siegfried A. and Meissburger, J{\"u}rgen and R{\"o}mer, Josef G. M. and Possen, P. von and Sagefka, Thomas}, title = {BIG KARL and COSY}, series = {The art and science of magnet design. A Festschrift in honor of Klaus Halbach. Vol. 1}, booktitle = {The art and science of magnet design. A Festschrift in honor of Klaus Halbach. Vol. 1}, publisher = {Lawrence Berkeley Lab., Univ. of California}, address = {Berkeley, CA.}, pages = {19 -- 28}, year = {1995}, language = {en} } @article{MartinHardtMeissburgeretal.1983, author = {Martin, Siegfried A. and Hardt, Arno and Meissburger, J{\"u}rgen and Berg, Georg P. A. and Hacker, Ulrich and H{\"u}rlimann, Werner and R{\"o}mer, Josef G. M. and Sagefka, Thomas and Retz, Adolf and Schult, Otto W. B.}, title = {The QQDDQ magnet spectrometer "BIG KARL"}, series = {Nuclear instruments and methods in physics research. Vol. 214, iss. 2-3}, journal = {Nuclear instruments and methods in physics research. Vol. 214, iss. 2-3}, issn = {0029-554x (E-Journal); 1872-9606 (E-Journal); 0167-5087 (Print)}, pages = {281 -- 303}, year = {1983}, language = {en} } @article{BechstedtHaasHackeretal.1985, author = {Bechstedt, U. and Haas, H. and Hacker, Ulrich and Hardt, Arno and Henn, K. and Martin, Siegfried A. and Wimmer, J.}, title = {Magnets for the German Spallation Source SNQ}, series = {IEEE transactions on nuclear science. Vol. 32, iss. 5}, journal = {IEEE transactions on nuclear science. Vol. 32, iss. 5}, issn = {1558-1578 (E-Journal); 0018-9499 (Print)}, pages = {3631 -- 3633}, year = {1985}, language = {en} } @article{SchultSistemichHardt1995, author = {Schult, Otto W. B. and Sistemich, K. and Hardt, Arno}, title = {Plans for investigations of subthreshold K+ production in p+A collisions / O. W. B. Schult [u.a.]}, series = {Nuclear Physics A. Vol. 583}, journal = {Nuclear Physics A. Vol. 583}, issn = {1873-1554 (E-journal); 0375-9474 (Print)}, pages = {629 -- 632}, year = {1995}, language = {en} } @inproceedings{MartinBergHardtetal.1979, author = {Martin, Siegfried A. and Berg, G. and Hardt, Arno and H{\"u}rlimann, Werner and K{\"o}hler, M. and Meißberger, J. and Sagefka, Thomas and Schult, Otto W. B.}, title = {First experience with the magnet spectrometer 'BIG KARL'}, series = {Use of magnetic spectrometers in nuclear physics : proceedings of the Daresbury study weekend 10 - 11 March 1979}, booktitle = {Use of magnetic spectrometers in nuclear physics : proceedings of the Daresbury study weekend 10 - 11 March 1979}, editor = {Sanderson, N. E.}, publisher = {Daresbury Lab.}, address = {Daresbury}, pages = {38 -- 42}, year = {1979}, language = {en} } @article{Grotendorst2012, author = {Grotendorst, Johannes}, title = {IAS Winter School: Hierarchical Methods for Dynamics in Complex Molecular Systems}, series = {Innovatives Supercomputing in Deutschland : inSiDE}, volume = {10}, journal = {Innovatives Supercomputing in Deutschland : inSiDE}, publisher = {HLRS}, address = {Stuttgart}, pages = {104 -- 1}, year = {2012}, language = {en} } @article{MartinBergHackeretal.1985, author = {Martin, Siegfried A. and Berg, Georg P. A. and Hacker, Ulrich and Hardt, Arno and K{\"o}hler, M. and Meissburger, J{\"u}rgen and Osterfeld, F. and Prasuhn, D. and Riepe, G. and Rogge, M. and Schult, Otto W. B. and Speth, J. and Turek, P. and Gaul, G. and Hagedoorn, H. and Heide, J. A. van der and Hinterberger, F. and Huber, M. and Jahn, R. and Mayer-Kuckuk, T. and Poth, H. and Paetz gen. Schieck, H.}, title = {COSY - a cooler synchrotron and storage ring}, series = {IEEE transactions on nuclear science. Vol. 32, iss. 5}, journal = {IEEE transactions on nuclear science. Vol. 32, iss. 5}, issn = {1558-1578 (E-Journal); 0018-9499 (Print)}, pages = {2694 -- 2696}, year = {1985}, language = {en} } @article{SchoeningBrunsHoffmannetal.1993, author = {Sch{\"o}ning, Michael Josef and Bruns, M. and Hoffmann, W. and Hoffmann, B.}, title = {Iodide ion-sensitive field-effect structures}, series = {Sensors and Actuators B. 15 (1993), H. 1-3}, journal = {Sensors and Actuators B. 15 (1993), H. 1-3}, isbn = {0925-4005}, pages = {192 -- 194}, year = {1993}, language = {en} } @article{BehbahaniProbstMaietal.2010, author = {Behbahani, Mehdi and Probst, M. and Mai, A. and Behr, Marek and Tran, L. and Vonderstein, K. and Mottaghy, K.}, title = {Numerical Prediction of Blood Damage in Biomedical Devices}, year = {2010}, language = {en} } @article{Hillgaertner2010, author = {Hillg{\"a}rtner, Michael}, title = {Normative Regulations}, series = {ECPE Cluster Seminar EMC in Hybrid and Electric Vehicles : 18 May 2010, Fraunhofer Institute Erlangen}, journal = {ECPE Cluster Seminar EMC in Hybrid and Electric Vehicles : 18 May 2010, Fraunhofer Institute Erlangen}, publisher = {European Center for Power Electronics}, address = {N{\"u}rnberg}, year = {2010}, language = {en} } @unpublished{BremmBlaneckBornheimetal.2024, author = {Bremm, Florian and Blaneck, Patrick Gustav and Bornheim, Tobias and Grieger, Niklas and Bialonski, Stephan}, title = {Preprint: Detecting sexism in German online newspaper comments with open-source text embeddings}, series = {arXiv}, journal = {arXiv}, doi = {10.48550/arXiv.2403.08592}, pages = {6 Seiten}, year = {2024}, abstract = {Sexism in online media comments is a pervasive challenge that often manifests subtly, complicating moderation efforts as interpretations of what constitutes sexism can vary among individuals. We study monolingual and multilingual open-source text embeddings to reliably detect sexism and misogyny in Germanlanguage online comments from an Austrian newspaper. We observed classifiers trained on text embeddings to mimic closely the individual judgements of human annotators. Our method showed robust performance in the GermEval 2024 GerMS-Detect Subtask 1 challenge, achieving an average macro F1 score of 0.597 (4th place, as reported on Codabench). It also accurately predicted the distribution of human annotations in GerMS-Detect Subtask 2, with an average Jensen-Shannon distance of 0.301 (2nd place). The computational efficiency of our approach suggests potential for scalable applications across various languages and linguistic contexts.}, language = {en} } @unpublished{BornheimGriegerBlanecketal.2023, author = {Bornheim, Tobias and Grieger, Niklas and Blaneck, Patrick Gustav and Bialonski, Stephan}, title = {Preprint: Speaker attribution in German parliamentary debates with QLoRA-adapted large language models}, series = {arXiv}, journal = {arXiv}, doi = {10.48550/arXiv.2309.09902}, pages = {8 Seiten}, year = {2023}, abstract = {The growing body of political texts opens up new opportunities for rich insights into political dynamics and ideologies but also increases the workload for manual analysis. Automated speaker attribution, which detects who said what to whom in a speech event and is closely related to semantic role labeling, is an important processing step for computational text analysis. We study the potential of the large language model family Llama 2 to automate speaker attribution in German parliamentary debates from 2017-2021. We fine-tune Llama 2 with QLoRA, an efficient training strategy, and observe our approach to achieve competitive performance in the GermEval 2023 Shared Task On Speaker Attribution in German News Articles and Parliamentary Debates. Our results shed light on the capabilities of large language models in automating speaker attribution, revealing a promising avenue for computational analysis of political discourse and the development of semantic role labeling systems.}, language = {en} } @article{KahmannRauschPluemeretal.2022, author = {Kahmann, Stephanie Lucina and Rausch, Valentin and Pl{\"u}mer, Jonathan and M{\"u}ller, Lars-Peter and Pieper, Martin and Wegmann, Kilian}, title = {The automized fracture edge detection and generation of three-dimensional fracture probability heat maps}, series = {Medical Engineering \& Physics}, volume = {2022}, journal = {Medical Engineering \& Physics}, number = {110}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1350-4533}, pages = {7 Seiten}, year = {2022}, abstract = {With proven impact of statistical fracture analysis on fracture classifications, it is desirable to minimize the manual work and to maximize repeatability of this approach. We address this with an algorithm that reduces the manual effort to segmentation, fragment identification and reduction. The fracture edge detection and heat map generation are performed automatically. With the same input, the algorithm always delivers the same output. The tool transforms one intact template consecutively onto each fractured specimen by linear least square optimization, detects the fragment edges in the template and then superimposes them to generate a fracture probability heat map. We hypothesized that the algorithm runs faster than the manual evaluation and with low (< 5 mm) deviation. We tested the hypothesis in 10 fractured proximal humeri and found that it performs with good accuracy (2.5 mm ± 2.4 mm averaged Euclidean distance) and speed (23 times faster). When applied to a distal humerus, a tibia plateau, and a scaphoid fracture, the run times were low (1-2 min), and the detected edges correct by visual judgement. In the geometrically complex acetabulum, at a run time of 78 min some outliers were considered acceptable. An automatically generated fracture probability heat map based on 50 proximal humerus fractures matches the areas of high risk of fracture reported in medical literature. Such automation of the fracture analysis method is advantageous and could be extended to reduce the manual effort even further.}, language = {en} } @article{AbelKahmannMellonetal.2020, author = {Abel, Alexander and Kahmann, Stephanie Lucina and Mellon, Stephen and Staat, Manfred and Jung, Alexander}, title = {An open-source tool for the validation of finite element models using three-dimensional full-field measurements}, series = {Medical Engineering \& Physics}, volume = {77}, journal = {Medical Engineering \& Physics}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1350-4533}, doi = {10.1016/j.medengphy.2019.10.015}, pages = {125 -- 129}, year = {2020}, abstract = {Three-dimensional (3D) full-field measurements provide a comprehensive and accurate validation of finite element (FE) models. For the validation, the result of the model and measurements are compared based on two respective point-sets and this requires the point-sets to be registered in one coordinate system. Point-set registration is a non-convex optimization problem that has widely been solved by the ordinary iterative closest point algorithm. However, this approach necessitates a good initialization without which it easily returns a local optimum, i.e. an erroneous registration. The globally optimal iterative closest point (Go-ICP) algorithm has overcome this drawback and forms the basis for the presented open-source tool that can be used for the validation of FE models using 3D full-field measurements. The capability of the tool is demonstrated using an application example from the field of biomechanics. Methodological problems that arise in real-world data and the respective implemented solution approaches are discussed.}, language = {en} } @article{YangKriechbaumerAlbrachtetal.2014, author = {Yang, Peng-Fei and Kriechbaumer, Andreas and Albracht, Kirsten and Sanno, Maximilian and Ganse, Bergita and Koy, Timmo and Shang, Peng and Br{\"u}ggemann, Gert-Peter and M{\"u}ller, Lars-Peter and Rittweger, J{\"o}rn}, title = {A novel optical approach for assessing in vivo bone segment deformation and its application in muscle-bone relationship studies in humans}, series = {Journal of Orthopaedic Translation}, volume = {2}, journal = {Journal of Orthopaedic Translation}, number = {4}, publisher = {Elsevier}, address = {Singapore}, issn = {2214-0328}, doi = {10.1016/j.jot.2014.07.078}, pages = {238 -- 238}, year = {2014}, language = {en} } @article{MeyerGaalenLeschingeretal.2019, author = {Meyer, Carolin and Gaalen, Kerstin van and Leschinger, Tim and Scheyerer, Max J. and Neiss, Wolfram F. and Staat, Manfred and M{\"u}ller, Lars-Peter and Wegmann, Kilian}, title = {Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement}, series = {BioMed Research International}, journal = {BioMed Research International}, doi = {10.1155/2019/9232813}, pages = {Article ID 9232813}, year = {2019}, language = {en} } @article{HacklBuessKammerlohretal.2021, author = {Hackl, Michael and Buess, Eduard and Kammerlohr, Sandra and Nacov, Julia and Staat, Manfred and Leschinger, Tim and M{\"u}ller, Lars-Peter and Wegmann, Kilian}, title = {A "comma sign"-directed subscapularis repair in anterosuperior rotator cuff tears yields biomechanical advantages in a cadaveric model}, series = {The american journal of sports medicine}, volume = {49}, journal = {The american journal of sports medicine}, number = {12}, publisher = {Sage}, address = {London}, issn = {1552-3365}, doi = {10.1177/03635465211031506}, pages = {3212 -- 3217}, year = {2021}, abstract = {Background: Additional stabilization of the "comma sign" in anterosuperior rotator cuff repair has been proposed to provide biomechanical benefits regarding stability of the repair. Purpose: This in vitro investigation aimed to investigate the influence of a comma sign-directed reconstruction technique for anterosuperior rotator cuff tears on the primary stability of the subscapularis tendon repair. Study Design: Controlled laboratory study. Methods: A total of 18 fresh-frozen cadaveric shoulders were used in this study. Anterosuperior rotator cuff tears (complete full-thickness tear of the supraspinatus and subscapularis tendons) were created, and supraspinatus repair was performed with a standard suture bridge technique. The subscapularis was repaired with either a (1) single-row or (2) comma sign technique. A high-resolution 3D camera system was used to analyze 3-mm and 5-mm gap formation at the subscapularis tendon-bone interface upon incremental cyclic loading. Moreover, the ultimate failure load of the repair was recorded. A Mann-Whitney test was used to assess significant differences between the 2 groups. Results: The comma sign repair withstood significantly more loading cycles than the single-row repair until 3-mm and 5-mm gap formation occurred (P≤ .047). The ultimate failure load did not reveal any significant differences when the 2 techniques were compared (P = .596). Conclusion: The results of this study show that additional stabilization of the comma sign enhanced the primary stability of subscapularis tendon repair in anterosuperior rotator cuff tears. Although this stabilization did not seem to influence the ultimate failure load, it effectively decreased the micromotion at the tendon-bone interface during cyclic loading. Clinical Relevance: The proposed technique for stabilization of the comma sign has shown superior biomechanical properties in comparison with a single-row repair and might thus improve tendon healing. Further clinical research will be necessary to determine its influence on the functional outcome.}, language = {en} } @article{RauschHarbrechtKahmannetal.2020, author = {Rausch, Valentin and Harbrecht, Andreas and Kahmann, Stephanie Lucina and Fenten, Thomas and Jovanovic, Nebojsa and Hackl, Michael and M{\"u}ller, Lars-Peter and Staat, Manfred and Wegmann, Kilian}, title = {Osteosynthesis of Phalangeal Fractures: Biomechanical Comparison of Kirschner Wires, Plates, and Compression Screws}, series = {The Journal of Hand Surgery}, volume = {45}, journal = {The Journal of Hand Surgery}, number = {10}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0363-5023}, doi = {10.1016/j.jhsa.2020.04.010}, pages = {987.e1 -- 987.e8}, year = {2020}, abstract = {Purpose The aim of this study was to compare several osteosynthesis techniques (intramedullary headless compression screws, T-plates, and Kirschner wires) for distal epiphyseal fractures of proximal phalanges in a human cadaveric model. Methods A total of 90 proximal phalanges from 30 specimens (index, ring, and middle fingers) were used for this study. After stripping off all soft tissue, a transverse distal epiphyseal fracture was simulated at the proximal phalanx. The 30 specimens were randomly assigned to 1 fixation technique (30 per technique), either a 3.0-mm intramedullary headless compression screw, locking plate fixation with a 2.0-mm T-plate, or 2 oblique 1.0-mm Kirschner wires. Displacement analysis (bending, distraction, and torsion) was performed using optical tracking of an applied random speckle pattern after osteosynthesis. Biomechanical testing was performed with increasing cyclic loading and with cyclic load to failure using a biaxial torsion-tension testing machine. Results Cannulated intramedullary compression screws showed significantly less displacement at the fracture site in torsional testing. Furthermore, screws were significantly more stable in bending testing. Kirschner wires were significantly less stable than plating or screw fixation in any cyclic load to failure test setup. Conclusions Intramedullary compression screws are a highly stable alternative in the treatment of transverse distal epiphyseal phalangeal fractures. Kirschner wires seem to be inferior regarding displacement properties and primary stability. Clinical relevance Fracture fixation of phalangeal fractures using plate osteosynthesis may have the advantage of a very rigid reduction, but disadvantages such as stiffness owing to the more invasive surgical approach and soft tissue irritation should be taken into account. Headless compression screws represent a minimally invasive choice for fixation with good biomechanical properties.}, language = {en} } @inproceedings{KahmannUschokWegmannetal.2018, author = {Kahmann, Stephanie Lucina and Uschok, Stephan and Wegmann, Kilian and M{\"u}ller, Lars-Peter and Staat, Manfred}, title = {Biomechanical multibody model with refined kinematics of the elbow}, series = {6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK}, booktitle = {6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK}, pages = {11 Seiten}, year = {2018}, abstract = {The overall objective of this study is to develop a new external fixator, which closely maps the native kinematics of the elbow to decrease the joint force resulting in reduced rehabilitation time and pain. An experimental setup was designed to determine the native kinematics of the elbow during flexion of cadaveric arms. As a preliminary study, data from literature was used to modify a published biomechanical model for the calculation of the joint and muscle forces. They were compared to the original model and the effect of the kinematic refinement was evaluated. Furthermore, the obtained muscle forces were determined in order to apply them in the experimental setup. The joint forces in the modified model differed slightly from the forces in the original model. The muscle force curves changed particularly for small flexion angles but their magnitude for larger angles was consistent.}, language = {en} }