@article{WeberArentMuenchetal.2016, author = {Weber, Tobias and Arent, Jan-Christoph and M{\"u}nch, Lukas and Duhovic, Miro and Balvers, Johannes Mattheus}, title = {A fast method for the generation of boundary conditions for thermal autoclave simulation}, series = {Composites Part A}, volume = {88}, journal = {Composites Part A}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1359-835X}, doi = {10.1016/j.compositesa.2016.05.036}, pages = {216 -- 225}, year = {2016}, abstract = {Manufacturing process simulation enables the evaluation and improvement of autoclave mold concepts early in the design phase. To achieve a high part quality at low cycle times, the thermal behavior of the autoclave mold can be investigated by means of simulations. Most challenging for such a simulation is the generation of necessary boundary conditions. Heat-up and temperature distribution in an autoclave mold are governed by flow phenomena, tooling material and shape, position within the autoclave, and the chosen autoclave cycle. This paper identifies and summarizes the most important factors influencing mold heat-up and how they can be introduced into a thermal simulation. Thermal measurements are used to quantify the impact of the various parameters. Finally, the gained knowledge is applied to develop a semi-empirical approach for boundary condition estimation that enables a simple and fast thermal simulation of the autoclave curing process with reasonably high accuracy for tooling optimization.}, language = {en} } @article{MiyamotoKanekoMatsuoetal.2010, author = {Miyamoto, Ko-ichiro and Kaneko, Kazumi and Matsuo, Akira and Wagner, Torsten and Kanoh, Shin`ichiro and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Miniaturized chemical imaging sensor system using an OLED display panel}, series = {Procedia Engineering}, volume = {5}, journal = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2010.09.160}, pages = {516 -- 519}, year = {2010}, abstract = {The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the currentvoltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.}, language = {en} } @article{SrivastavaSinghAggarwaletal.2010, author = {Srivastava, Alok and Singh, Virendra and Aggarwal, Pranav and Schneeweiss, F. and Scherer, Ulrich W. and Friedrich, W.}, title = {Optical studies of insulating polymers for radiation dose monitoring}, series = {Indian Journal of Pure and Applied Physics}, volume = {48}, journal = {Indian Journal of Pure and Applied Physics}, number = {11}, publisher = {Council Of Scientific And Industrial Research (CSIR), National Institute Of Science Communication and Policy Research (NIScPR)}, address = {New Delhi}, isbn = {0019-5596}, pages = {782 -- 786}, year = {2010}, abstract = {The optical study carried out on insulating polymers namely polyethyleneterephthalate (PET) and polyvinylchloride (PVC) has been described. The polymers are exposed to different radiation doses by exposing them to swift heavy ions of carbon (90 MeV), silicon (120 MeV) and nickel (100 MeV) which influence on their optical properties. The studies show that amongst the investigated polymers, PVC and PET have potential for application as dosimeter beyond a threshold dose which is strongly dependent on the nature of the material and the radiation type. The optical micrographs show a distinct change in colour of the sample with increase in radiation dose.}, language = {en} } @article{GebhardtSchmidtHoetteretal.2010, author = {Gebhardt, Andreas and Schmidt, Frank-Michael and H{\"o}tter, Jan-Steffen and Sokalla, Wolfgang and Sokalla, Patrick}, title = {Additive manufacturing by selective laser melting the realizer desktop machine and its application for the dental industry}, series = {Physics Procedia}, volume = {5 B}, journal = {Physics Procedia}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1875-3892}, doi = {10.1016/j.phpro.2010.08.082}, pages = {543 -- 549}, year = {2010}, abstract = {Additive Manufacturing of metal parts by Selective Laser Melting has become a powerful tool for the direct manufacturing of complex parts mainly for the aerospace and medical industry. With the introduction of its desktop machine, Realizer targeted the dental market. The contribution describes the special features of the machine, discusses details of the process and shows manufacturing results focused on metal dental devices.}, language = {en} } @article{AlexopoulosHoffschmidt2010, author = {Alexopoulos, Spiros and Hoffschmidt, Bernhard}, title = {Solarthermische Kraftwerke mit thermischen Speichern}, series = {Chemie Ingenieur Technik}, volume = {82}, journal = {Chemie Ingenieur Technik}, number = {9}, publisher = {Wiley-VCH}, address = {Weinheim}, isbn = {1522-2640}, doi = {10.1002/cite.201050678}, pages = {1606}, year = {2010}, abstract = {Solarthermische Kraftwerke stellen eine bedeutende Technologieoption f{\"u}r einen nachhaltigen Energiemix der Zukunft dar. Sie konzentrieren die Strahlung der Sonne, erzeugen W{\"a}rme und wandeln diese mit konventioneller Kraftwerkstechnik in Strom um. Die W{\"a}rme kann auch gespeichert werden, so dass der Betrieb w{\"a}hrend des Durchzugs von Wolken m{\"o}glich ist und bis in die Abendstunden hinein verl{\"a}ngert werden kann. Zu den solarthermischen Kraftwerken geh{\"o}ren neben der Parabolrinne und dem Solarturm der Fresnel-Kollektor und die Dish-Stirling-Systeme. Im Zuge einer sp{\"a}teren Vergr{\"o}ßerung des Solarfeldes von Solarkraftwerken kann mithilfe von thermischen Energiespeichern die solare Energieerzeugung bei gleichbleibender Kraftwerksleistung sukzessiv bis um den Faktor 3 erweitert werden. Es besteht so die M{\"o}glichkeit einer massiven Substitution von fossilen Brennstoffen.Bei den ersten solarthermischen Speichern f{\"u}r die SEGS-Parabolrinnekraftwerke wurde {\"O}l als Speichermedium eingesetzt. Ein weiteres Speichermedium ist Salzschmelze, die im Andasol-1-Projekt in Spanien sowie bei Solarturmkraftwerken eingesetzt wird. Beton ist ein weiteres m{\"o}gliches Speichermaterial f{\"u}r Parabolrinnensysteme. Eine weitere Alternative bei einem Solarturmkraftwerk mit Luft als W{\"a}rmetr{\"a}germedium ist die Verwendung von keramischen Feuerfestmaterialien in Form von Sch{\"u}ttungen oder stapelbaren, por{\"o}sen Elementen. In J{\"u}lich wurde das weltweit erste solarthermische Turmkraftwerk mit einer Leistung von 1,5 MWe, das Luft als W{\"a}rmetr{\"a}germedium einsetzt und einen solchen Speicher verwendet, gebaut.}, language = {de} } @article{PoghossianWagnerSchoening2010, author = {Poghossian, Arshak and Wagner, Holger and Sch{\"o}ning, Michael Josef}, title = {Automatisiertes „wafer level"-Testsystem zur Charakterisierung von siliziumbasierten Chemo- und Biosensoren}, series = {Tagungsband: Sensoren und Messsysteme 2010}, journal = {Tagungsband: Sensoren und Messsysteme 2010}, publisher = {VDE Verlag}, address = {Berlin}, isbn = {978-3-8007-3260-9}, pages = {89 -- 92}, year = {2010}, abstract = {Es wurde ein automatisiertes, computerunterst{\"u}tztes Testsystem f{\"u}r die Funktionspr{\"u}fung und Charakterisierung von (bio-)chemischen Sensoren auf Waferebene entwickelt und in einen konventionellen Spitzenmessplatz integriert. Das System erm{\"o}glicht die Charakterisierung und Identifizierung „funktionstauglicher" Sensoren bereits auf Waferebene zwischen den einzelnen Herstellungsschritten, wodurch weitere, bisher {\"u}bliche Verarbeitungsschritte wie das Fixieren, Bonden und Verkapseln f{\"u}r die defekten oder nicht funktionstauglichen Sensorstrukturen entf{\"a}llt. Außerdem bietet eine speziell entworfene miniaturisierte Durchflussmesszelle die M{\"o}glichkeit, bereits auf Waferlevel die Sensitivit{\"a}t, Drift, Hysterese und Ansprechzeit der (bio-)chemischen Sensoren zu charakterisieren. Das System wurde exemplarisch mit kapazitiven, pH-sensitiven EIS- (Elektrolyt-Isolator-Silizium) Strukturen und ISFET- (ionensensitiver Feldeffekttransistor) Strukturen mit verschiedenen Geometrien und Gate-Layouts getestet.}, language = {de} } @article{KirchnerOberlaenderFriedrichetal.2010, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Friedrich, Peter and Rysstad, Gunnar and Berger, J{\"o}rg and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry}, series = {Procedia Engineering}, volume = {5}, journal = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2010.09.098}, pages = {264 -- 267}, year = {2010}, abstract = {A calorimetric gas sensor is presented for the monitoring of gas-phase H2O2 at elevated temperature during sterilization processes in aseptic food industry. The sensor consists of two temperature-sensitive thin-film resistances built up on a polyimide foil with a thickness of 25 μm, which are passivated with a layer of SU-8 photo resist and catalytically activated with manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilizes the elevated temperature of an evaporated H2O2 aerosol. In an experimental set-up, the sensor has shown a sensitivity of 4.78 °C/(\%v/v) in a H2O2 concentration range of 0 to 10\% v/v at an evaporation temperature of 240 ∘C. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied evaporation temperatures of the gas stream. The sensor characterization demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of sterilization processes.}, language = {en} } @article{BohrnStuetzFleischeretal.2010, author = {Bohrn, Ulrich and St{\"u}tz, Evamaria and Fleischer, Maximilian and Sch{\"o}ning, Michael Josef}, title = {Real-time detection of CO by eukaryotic cells}, series = {Procedia Engineering}, volume = {5}, journal = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, pages = {17 -- 20}, year = {2010}, abstract = {In this contribution, we focus on the detection of toxic gases with living eukaryotic cells. A cell-based gas sensor system, able to measure the effects of direct exposure of gases to cells in real-time, was set up. Impedance data as well as oxygen consumption of Chinese hamster lung fibroblast cells (V79) were analysed upon exposure to carbon monoxide (CO). The CO (diluted in wet synthetic air) affects the cell respiration as indicated by an attenuated respiration signal after the CO exposure as well as an instant increase of the capacitive part of the impedance signal during the gas exposure.}, language = {en} } @inproceedings{SchollBartellaMoluluoetal.2019, author = {Scholl, Ingrid and Bartella, Alexander K. and Moluluo, Cem and Ertural, Berat and Laing, Frederic and Suder, Sebastian}, title = {MedicVR : Acceleration and Enhancement Techniques for Direct Volume Rendering in Virtual Reality}, series = {Bildverarbeitung f{\"u}r die Medizin 2019 : Algorithmen - Systeme - Anwendungen}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2019 : Algorithmen - Systeme - Anwendungen}, publisher = {Springer Vieweg}, address = {Wiesbaden}, isbn = {978-3-658-25326-4}, doi = {10.1007/978-3-658-25326-4_32}, pages = {152 -- 157}, year = {2019}, language = {en} } @article{SponagelBaroudFalketal.2004, author = {Sponagel, Stefan and Baroud, Gamal and Falk, R. and Crookshank, M.}, title = {Experimental and theoretical investigation of directional permeability of human vertebral cancellous bone for cement infiltration. G. Baroud, R. Falk, M. Crookshank, S. Sponagel, T. Steffen}, series = {Journal of Biomechanics. 37 (2004), H. 2}, journal = {Journal of Biomechanics. 37 (2004), H. 2}, isbn = {0021-9290}, pages = {189 -- 196}, year = {2004}, language = {en} } @article{BodeBartschBoulikasetal.1998, author = {Bode, J{\"u}rgen and Bartsch, J{\"o}rg W. and Boulikas, Toulikas and Iber, Michaela and Mielke, Christian and Sch{\"u}beler, Dirk and Seibler, Jost and Benham, Craig}, title = {Transcription-promoting genomic sites in mammalia: their elucidation and architectural principles}, series = {Gene therapy \& molecular biology}, volume = {1}, journal = {Gene therapy \& molecular biology}, number = {1}, issn = {1529-9120}, pages = {1 -- 29}, year = {1998}, language = {en} } @inproceedings{GrundmannBauerBorchersetal.2019, author = {Grundmann, Jan Thimo and Bauer, Waldemar and Borchers, Kai and Dumont, Etienne and Grimm, Christian D. and Ho, Tra-Mi and Jahnke, Rico and Koch, Aaron D. and Lange, Caroline and Maiwald, Volker and Meß, Jan-Gerd and Mikulz, Eugen and Quantius, Dominik and Reershemius, Siebo and Renger, Thomas and Sasaki, Kaname and Seefeldt, Patric and Spietz, Peter and Spr{\"o}witz, Tom and Sznajder, Maciej and Toth, Norbert and Ceriotti, Matteo and McInnes, Colin and Peloni, Alessandro and Biele, Jens and Krause, Christian and Dachwald, Bernd and Hercik, David and Lichtenheldt, Roy and Wolff, Friederike and Koncz, Alexander and Pelivan, Ivanka and Schmitz, Nicole and Boden, Ralf and Riemann, Johannes and Seboldt, Wolfgang and Wejmo, Elisabet and Ziach, Christian and Mikschl, Tobias and Montenegro, Sergio and Ruffer, Michael and Cordero, Federico and Tardivel, Simon}, title = {Solar sails for planetary defense \& high-energy missions}, series = {IEEE Aerospace Conference Proceedings}, booktitle = {IEEE Aerospace Conference Proceedings}, doi = {10.1109/AERO.2019.8741900}, pages = {1 -- 21}, year = {2019}, abstract = {20 years after the successful ground deployment test of a (20 m) 2 solar sail at DLR Cologne, and in the light of the upcoming U.S. NEAscout mission, we provide an overview of the progress made since in our mission and hardware design studies as well as the hardware built in the course of our solar sail technology development. We outline the most likely and most efficient routes to develop solar sails for useful missions in science and applications, based on our developed `now-term' and near-term hardware as well as the many practical and managerial lessons learned from the DLR-ESTEC Gossamer Roadmap. Mission types directly applicable to planetary defense include single and Multiple NEA Rendezvous ((M)NR) for precursor, monitoring and follow-up scenarios as well as sail-propelled head-on retrograde kinetic impactors (RKI) for mitigation. Other mission types such as the Displaced L1 (DL1) space weather advance warning and monitoring or Solar Polar Orbiter (SPO) types demonstrate the capability of near-term solar sails to achieve asteroid rendezvous in any kind of orbit, from Earth-coorbital to extremely inclined and even retrograde orbits. Some of these mission types such as SPO, (M)NR and RKI include separable payloads. For one-way access to the asteroid surface, nanolanders like MASCOT are an ideal match for solar sails in micro-spacecraft format, i.e. in launch configurations compatible with ESPA and ASAP secondary payload platforms. Larger landers similar to the JAXA-DLR study of a Jupiter Trojan asteroid lander for the OKEANOS mission can shuttle from the sail to the asteroids visited and enable multiple NEA sample-return missions. The high impact velocities and re-try capability achieved by the RKI mission type on a final orbit identical to the target asteroid's but retrograde to its motion enables small spacecraft size impactors to carry sufficient kinetic energy for deflection.}, language = {en} } @article{KirchnerSpelthahnSchoeningetal.2010, author = {Kirchner, Patrick and Spelthahn, Heiko and Sch{\"o}ning, Michael Josef and Henkel, Hartmut and Schneider, Andreas and Friedrich, Peter and Kolstad, Jens and Berger, J{\"o}rg}, title = {Realisierung eines Polyimid-basierten kalorimetrischen Gassensors zur Inline-{\"U}berwachung der H2O2-Konzentration in aseptischen Abf{\"u}llsystemen}, series = {Tagungsband: Sensoren und Messsysteme 2010}, journal = {Tagungsband: Sensoren und Messsysteme 2010}, publisher = {VDE Verlag}, address = {Berlin}, isbn = {978-3-8007-3260-9}, pages = {607 -- 612}, year = {2010}, abstract = {In aseptischen Abf{\"u}llsystemen wird Wasserstoffperoxid in der Gasphase aufgrund der stark oxidativen Wirkung zur Packstoffentkeimung eingesetzt. Dabei wird die Effizienz der Entkeimung im Wesentlichen von der vorliegenden H2O2-Konzentration im Packstoff bestimmt. Zur Inline-{\"U}berwachung der H2O2-Konzentration wurde ein kalorimetrischer Gassensor auf Basis einer flexiblen Polyimidfolie aus temperatursensitiven D{\"u}nnschicht-Widerst{\"a}nden und Mangan(IV)-oxid als katalytische Transducerschicht realisiert. Der Sensor weist ein lineares Ansprechverhalten mit einer Sensitivit{\"a}t von 7,15 °C/Vol.-\% in einem H2O2-Konzentrationsbereich von 0 bis 8 Vol.-\% auf. Weiterhin wurde zur Auslesung des Sensorsignals eine RFID-Elektronik, bestehend aus einem Sensor-Tag und einer Sende-/Empfangseinheit ausgelegt, sowie eine Abfolge des Messzyklus aufgestellt. Im weiteren Verlauf soll der kalorimetrische Gassensor mit der RFID-Elektronik gekoppelt und in eine Testverpackung zur Inline-{\"U}berwachung der H2O2-Konzentration in aseptischen Abf{\"u}llsystemen implementiert werden.}, language = {de} } @article{SpelthahnSchaffrathCoppeetal.2010, author = {Spelthahn, Heiko and Schaffrath, Sophie and Coppe, Thomas and Rufi, Frederic and Sch{\"o}ning, Michael Josef}, title = {Development of an electrolyte-insulator-semiconductor (EIS) based capacitive heavy metal sensor for the detection of Pb2+ und Cd2+ ions}, series = {Physica status solidi (a) : applications and material science}, volume = {207}, journal = {Physica status solidi (a) : applications and material science}, number = {4}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6300}, doi = {10.1002/pssa.200983306}, pages = {930 -- 934}, year = {2010}, abstract = {Chalcogenide glass materials as membranes for potentiometric sensors for chemical analysis in solutions have been studied since more than 20 years. In this work, an electrolyte-insulator-semiconductor structure was combined with chalcogenide glass membranes prepared by means of the pulsed laser deposition technique. Depending on the membrane composition a selectivity to different ions (Cd2+ and Pb2+) is achieved. The different sensor membranes have been physically characterised using microscopy, ellipsometry, profilometry, atomic force microscopy (AFM), scanning electron microscopy (SEM) and Rutherford backscattering spectrometry (RBS). The electrochemical behaviour has been investigated via capacitance/voltage (C/V) and constant capacitance (ConCap) measurements and results in a Cd2+ sensitivity of 23.1 ± 0.6 mV per decade in a linear range from 7 × 10-6 to 10-2 mol/l and 24.4 ± 0.5 mV per decade in a linear range from 5 × 10-6 to 10-2 mol/l for Pb2+, respectively.}, language = {en} } @article{WernerSpelthahnSchoeningetal.2010, author = {Werner, Frederik and Spelthahn, Heiko and Sch{\"o}ning, Michael Josef and Krumbe, Christoph and Wagner, Torsten and Yoshinobu, Tatsuo and Keusgen, Michael}, title = {Neue Ansteuerungselektronik f{\"u}r LAPS-basierte Biosensoren zur gleichzeitig ortsaufgel{\"o}sten Messung der pH-Konzentration}, series = {Tagungsband: Sensoren und Messsysteme 2010}, journal = {Tagungsband: Sensoren und Messsysteme 2010}, publisher = {VDE Verlag}, address = {Berlin}, isbn = {978-3-8007-3260-9}, pages = {109 -- 114}, year = {2010}, abstract = {Ein lichtadressierbarer potentiometrischer Sensor (LAPS) kann die Konzentration eines oder mehrerer Analyten ortsaufgel{\"o}st auf der Sensoroberfl{\"a}che nachweisen. Dazu wird mit einer modulierten Lichtquelle die Halbleiterstruktur des zu untersuchenden Bereiches angeregt und ein entsprechender Photostrom ausgelesen. Durch gleichzeitige Anregung mehrere Bereiche durch Lichtquellen mit unterschiedlichen Modulationsfrequenzen k{\"o}nnen diese auch zeitgleich ausgelesen werden. Mit der neuen, hier vorgestellten Ansteuerungselektronik integriert in einem "Field Programmable Gate Array" (FPGA) ist es m{\"o}glich, mehrere Leuchtquellen gleichzeitig mit unterschiedlichen, w{\"a}hrend der Laufzeit festlegbaren Frequenzen, Phasen und Lichtintensit{\"a}ten zu betreiben. Somit kann das Frequenzverhalten des Sensors untersucht und die Konzentration des Analyten {\"u}ber das Oberfl{\"a}chenpotential mit Hilfe von Strom/Spannungs-Kurven und Phase/Spannungs-Kurven bestimmt werden.}, language = {de} } @article{DigelWehlitzKayseretal.2018, author = {Digel, Ilya and Wehlitz, V. and Kayser, Peter and Figiel-Lange, A. and Bassam, Rasha and Rundstedt, F. von}, title = {Suspension depletion approach for exemption of infected Solanum jasminoides cells from pospiviroids}, series = {Plant Pathology}, volume = {67}, journal = {Plant Pathology}, number = {2}, publisher = {Wiley}, address = {Oxford}, issn = {1365-3059}, doi = {10.1111/ppa.12750}, pages = {358 -- 365}, year = {2018}, abstract = {Despite numerous studies, viroid elimination from infected plants remains a very challenging task. This study introduces for the first time a novel 'suspension depletion' approach for exemption of Solanum jasminoides plants from viroids. The proposed method implies initial establishment of suspension cultures of the infected plant cells. The suspended cells were then physically treated (mild thermotherapy, 33 °C), which presumably delayed the replication of the viroid. The viroid concentration in the treated biomass was monitored weekly using pospiviroid-specific PCR. After 10-12 weeks of continuous treatment, a sufficient decrease in viroid concentration was observed such that the infection became undetectable by PCR. The treated single cells then gave rise to microcolonies on a solid culture medium and the obtained viroid-negative clones were further promoted to regenerate into viroid-free plants. Three years of accumulated experimental data suggests feasibility, broad applicability, and good efficacy of the proposed approach.}, language = {en} } @article{BaeckerPoghossianSchoeningetal.2010, author = {B{\"a}cker, Matthias and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Schnitzler, Thomas and Biselli, Manfred and Zang, Werner and Wagner, Patrick}, title = {Entwicklung eines modularen festk{\"o}rperbasierten Sensorsystems f{\"u}r die {\"U}berwachung von Zellkulturfermentationen}, series = {Tagungsband: Sensoren und Messsysteme 2010}, journal = {Tagungsband: Sensoren und Messsysteme 2010}, publisher = {VDE Verlag}, address = {Berlin}, isbn = {978-3-8007-3260-9}, pages = {688 -- 698}, year = {2010}, abstract = {In diesem Beitrag werden Ergebnisse der Entwicklung eines modularen festk{\"o}rperbasierten Sensorsystems f{\"u}r die {\"U}berwachung von Zellkulturfermentationen pr{\"a}sentiert. Zur Messung der Elektrolytleitf{\"a}higkeit wurde das Layout von Interdigitalelektroden angepasst, um in vergleichsweise gut leitenden Elektrolyten zu messen. Durch Quervernetzung von Glucose-Oxidase mit Glutaraldehyd und Immobilisierung auf einer Platinelektrode wurde ein amperometrischer Glucosesensor mit einem linearen Messbereich von bis zu 2 mM und einer Sensitivit{\"a}t von 168 nA/mM realisiert.}, language = {de} } @article{StaatBaroudTopcuetal.2008, author = {Staat, Manfred and Baroud, Gamal and Topcu, M. and Sponagel, Stefan}, title = {Soft Materials in Technology and Biology - Characteristics, Properties, and Parameter Identification}, series = {Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.)}, journal = {Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.)}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-540-75408-4}, pages = {253 -- 315}, year = {2008}, language = {en} } @article{TemizArtmannBaşkurtPekcetinetal.2000, author = {Temiz Artmann, Ayseg{\"u}l and Ba{\c{s}}kurt, Oǧuz Kerim and Pekcetin, C. and Kandemir, F.}, title = {Leukocyte activation, oxidant stress and red blood cell properties after acute, exhausting exercise in rats. Temiz, A.; Baskurt, O. K., Pekcetin, C.; Kandemir, F.; G{\"u}re, A.}, series = {Clinical Hemorheology and Microcirculation. 22 (2000), H. 4}, journal = {Clinical Hemorheology and Microcirculation. 22 (2000), H. 4}, isbn = {1386-0291}, pages = {253 -- 259}, year = {2000}, language = {en} } @article{TemizArtmannYalcinResmietal.2002, author = {Temiz Artmann, Ayseg{\"u}l and Yalcin, Ozlem and Resmi, Halil and Ba{\c{s}}kurt, Oǧuz Kerim}, title = {Can white blood cell activation be one of the major factors that affect hemorheological parameters during and after exercise?}, series = {Clinical Hemorheology and Microcirculation. 26 (2002), H. 3}, journal = {Clinical Hemorheology and Microcirculation. 26 (2002), H. 3}, isbn = {1386-0291}, pages = {189 -- 193}, year = {2002}, language = {en} }