@inproceedings{KernDikta2009, author = {Kern, Alexander and Dikta, Gerhard}, title = {Probability of damage of electrical and electronic systems due to indirect lightning flashes - investigation of data from German insurance companies}, year = {2009}, abstract = {In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not.}, subject = {Blitzschutz}, language = {en} } @inproceedings{Kern2002, author = {Kern, Alexander}, title = {Risikomanagement : Absch{\"a}tzung des Schadensrisikos f{\"u}r bauliche Anlagen - Die neue Vornorm DIN V VDE V 0185 Teil 2 : 2002}, year = {2002}, abstract = {Alle Unternehmen sind vielf{\"a}ltigen Risiken ausgesetzt, die Finanz- und Betriebsbereiche einschließlich Dienstleistungen betreffen k{\"o}nnen. Die Firmen m{\"u}ssen {\"u}blicherweise Risiken eingehen, um im Wettbewerb bestehen zu k{\"o}nnen. Entscheidend ist, dass man sich {\"u}ber die Risiken bewusst ist, diese einsch{\"a}tzen und kontrollieren kann. Falsche Einsch{\"a}tzungen, Vers{\"a}umnisse und Fehlentscheidungen k{\"o}nnen empfindliche finanzielle Sch{\"a}den bis hin zum Totalverlust nach sich ziehen. Ein effektives Risikomanagement ist heute als wichtiger Sicherheitsfaktor anzusehen und sollte zur strategischen Unternehmensf{\"u}hrung geh{\"o}ren. Ein vorausschauendes Risikomanagement beinhaltet, Risiken f{\"u}r das Unternehmen zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent, welche Risiken sinnvollerweise {\"u}ber Versicherungen abgedeckt werden sollten. Beim Versicherungsmanagement ist jedoch zu bedenken, dass zur Erreichung bestimmter Ziele Versicherungen nicht geeignet sind (z.B. Erhaltung der Lieferf{\"a}higkeit). Eintrittswahrscheinlichkeiten bestimmter Risiken lassen sich durch Versicherungen nicht ver{\"a}ndern. Bei Unternehmen, die mit umfangreichen elektronischen Einrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Ber{\"u}cksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nicht-Verf{\"u}gbarkeit der elektronischen Einrichtungen und damit der Produktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardware-Schaden an der betroffenen Anlage oft bei weitem {\"u}bersteigt. Im Blitzschutz gewinnt innovatives Denken in Schadensrisiken langsam an Bedeutung. Risikoanalysen haben die Objektivierung und Quantifizierung der Gef{\"a}hrdung von baulichen Anlagen und ihrer Inhalte durch direkte und indirekte Blitzeinschl{\"a}ge zum Ziel. Seinen Niederschlag hat dieses neue Denken in der neuen deutschen Norm DIN V 0185-2 VDE V 0185 Teil 2 gefunden. Die hier vorgegebene Risikoanalyse gew{\"a}hrleistet, dass ein f{\"u}r alle Beteiligten nachvollziehbares Blitzschutz-Konzept erstellt werden kann, das technisch und wirtschaftlich optimiert ist, d.h. bei m{\"o}glichst geringem Aufwand den notwendigen Schutz gew{\"a}hrleisten kann. Die sich aus der Risikoanalyse ergebenden Schutzmaßnahmen sind dann in den weiteren Normenteilen der neuen Reihe VDE V 0185 detailliert beschrieben.}, language = {de} } @article{Kern2003, author = {Kern, Alexander}, title = {Risikomanagement f{\"u}r den Blitzschutz - Absch{\"a}tzung des Blitzschadensrisikos nach der neuen Vornorm VDE V 0185 Teil 2 : 2002}, year = {2003}, abstract = {Ein vorausschauendes Risikomanagement beinhaltet, Risiken zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent,welche Risiken sinnvoll {\"u}ber Versicherungen abgedeckt werden sollten. Bei Unternehmen, die mit umfangreichen elektronischenEinrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Ber{\"u}cksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nichtverf{\"u}gbarkeit der elektronischen Einrichtungen und damit derProduktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardwareschaden an der betroffenen Anlage oft bei weitem {\"u}bersteigt.}, language = {de} } @inproceedings{Kern2003, author = {Kern, Alexander}, title = {Risikomanagement nach DIN V 0185-2 VDE V 0185 Teil 2: 2002-11 - Einige Beispiele und erste Erfahrungen}, year = {2003}, abstract = {Die neue Vornorm VDE V 0185 Teil 2 „Risikomanagement: Absch{\"a}tzung des Schadensrisikos f{\"u}r bauliche Anlagen" [1] ist seit November 2002 g{\"u}ltig. Sie erm{\"o}glicht nicht nur die Ermittlung der Schutzklasse eines Blitzschutzsystems, sondern auch die Untersuchung zur Notwendigkeit anderer Schutzmaßnahmen gegen Blitzeinwirkungen ({\"U}berspannungsschutzger{\"a}te in Unterverteilern und/oder an Endger{\"a}ten, Schirmung des Geb{\"a}udes und/oder interner R{\"a}ume, Potentialsteuerung, Brandmelde- und Feuerl{\"o}scheinrichtungen, etc.) nach objektiven Kriterien und damit in einer f{\"u}r alle Beteiligten grunds{\"a}tzlich nachvollziehbaren Art und Weise. Dass eine solche Analyse rel. komplex sein muss und der intensiven Besch{\"a}ftigung bedarf, ist deshalb nicht verwunderlich. Die Komplexit{\"a}t des Verfahrens sollte allerdings nicht dazu f{\"u}hren, die Vornorm als Ganzes abzulehnen. Die Vornorm beruht auf dem Stand der Diskussion im internationalen Normengremium IEC TC81 WG9 Ende des Jahres 2000. Integriert wurden einige nationale Besonderheiten, die aus Sicht des zust{\"a}ndigen Normenkomitees DKE K251 erforderlich erschienen. In Deutschland konnten und k{\"o}nnen nun erste breite Erfahrungen in der Anwendung dieser Risikoanalyse gesammelt werden; in anderen L{\"a}ndern ist dies noch nicht m{\"o}glich. Diese Erfahrungen k{\"o}nnen dann, nach Diskussion im nationalen Rahmen, in die internationale Normenarbeit eingebracht werden. Im folgenden Beitrag sollen einige, seit Erscheinen der Vornorm oft wiederkehrende Fragen dargestellt und L{\"o}sungsvorschl{\"a}ge vorgestellt werden. Dabei wird auch auf die Tendenzen im internationalen Normengremium IEC TC81 WG9 eingegangen, d.h. auf den aktuellen Entwurf zur IEC 62305-2 [3]. Die L{\"o}sungsvorschl{\"a}ge werden begr{\"u}ndet, sind allerdings weitestgehend subjektive Meinung des Autors. F{\"u}r {\"u}bliche bauliche Anlagen ist die Anwendung der Vornorm rel. einfach m{\"o}glich. Auch f{\"u}r spezielle F{\"a}lle k{\"o}nnen die darin festgelegten Verfahren herangezogen werden; allerdings sind dann einige weiterf{\"u}hrende {\"U}berlegungen notwendig, die der Planer von Blitzschutzsystemen durchf{\"u}hren muss. Anhand zweier Beispiele soll die Anwendung der VDE V 0185 Teil 2 auf solche speziellen F{\"a}lle dargestellt werden.}, language = {de} } @inproceedings{ButenwegRosinKubalski2013, author = {Butenweg, Christoph and Rosin, Julia and Kubalski, Thomas}, title = {Seismic response of conventional and base-isolated liquid storage tanks}, series = {International Conference on Earthquake Engineering : 29.-31.05.2013, Skopje, Mazedonien}, booktitle = {International Conference on Earthquake Engineering : 29.-31.05.2013, Skopje, Mazedonien}, organization = {International Conference on Earthquake Engineering <2013, Skopje>}, pages = {1 -- 8}, year = {2013}, language = {en} } @inproceedings{RenaultButenweg2005, author = {Renault, Philippe and Butenweg, Christoph}, title = {Seismic vulnerability assessment of bridges}, series = {First Munich Bridge Assessment Conference, MBAC 2005 : Munich, 20.-25. June 2005}, booktitle = {First Munich Bridge Assessment Conference, MBAC 2005 : Munich, 20.-25. June 2005}, organization = {Munich Bridge Assessment Conference <1, 2005>}, pages = {1 -- 16}, year = {2005}, language = {en} } @inproceedings{ButenwegKuhlmannLopezetal.2003, author = {Butenweg, Christoph and Kuhlmann, Winfried and Lopez, M. and Fernandez, S.}, title = {Seismic vulnerability assessment of the Aachen Cathedral based on measurements and numerical simulations}, series = {International Conference on Earthquake Engineering to mark 40 years from Catastrophic 1963 Skopje Earthquake, Skopje 2003}, booktitle = {International Conference on Earthquake Engineering to mark 40 years from Catastrophic 1963 Skopje Earthquake, Skopje 2003}, organization = {International conference in earthquake engineering to mark 40 years from catastrophic 1963 Skopje earthquake <2003, Skopje>}, pages = {1 -- 8}, year = {2003}, language = {en} } @inproceedings{ButenwegSadeghAzarMeskouris2004, author = {Butenweg, Christoph and Sadegh-Azar, H. and Meskouris, Konstantin}, title = {Seismische Vulnerabilit{\"a}t von bestehenden Bauwerken}, series = {5. Forum und Gefahrentag : auf der Suche nach dem Risiko : ein aktuelles Symposium zu Fragen der Risikowahrnehmung und Katastrophenvorsorge in Deutschland, ZDF Mainz Lerchenberg, 13. - 14. Oktober, 2004}, booktitle = {5. Forum und Gefahrentag : auf der Suche nach dem Risiko : ein aktuelles Symposium zu Fragen der Risikowahrnehmung und Katastrophenvorsorge in Deutschland, ZDF Mainz Lerchenberg, 13. - 14. Oktober, 2004}, pages = {1}, year = {2004}, language = {de} } @inproceedings{BehrensFrentzelKern2009, author = {Behrens, J{\"o}rg and Frentzel, Ralf and Kern, Alexander}, title = {Simulation der transienten Spannungsverl{\"a}ufe im Eigenbedarfsnetz eines Großkraftwerks bei einem kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung}, isbn = {978-3-8007-3197-8}, year = {2009}, abstract = {8. VDE/ABB-Blitzschutztagung, 29. - 30. Oktober 2009 in Neu-Ulm. Blitzschutztagung <8, 2009, Neu-Ulm> Berlin : VDE Verl. 2009 Großkraftwerke k{\"o}nnen durch Blitzentladungen mit potentiellen Auswirkungen auf deren Verf{\"u}gbarkeit und Sicherheit gef{\"a}hrdet werden. Ein sehr spezielles Szenario, welches aus aktuellem Anlass zu untersuchen war, betrifft den kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung am Netzanschluss der Anlage. Wird nun noch ein sogenannter Schirmfehler unterstellt, d.h. der direkte Blitzeinschlag erfolgt in ein Leiterseil des Hoch- bzw. H{\"o}chstspannungsnetzes und nicht in das dar{\"u}ber gespannte Erdseil, so bedeutet dies eine extreme elektromagnetische Einwirkung. Der vorliegende Beitrag befasst sich mit der Simulation eines solchen Blitzeinschlages und dessen Auswirkungen auf den Netzanschluss und die Komponenten der elektrischen Eigenbedarfsanlagen eines Kraftwerks auf den unterlagerten Spannungsebenen. Die dabei gewonnenen Erkenntnisse lassen sich ohne Einschr{\"a}nkungen auf Industrieanlagen mit Mittelspannungs-Netzanschluss und ohne eigener Stromversorgung {\"u}bertragen.}, subject = {Blitzschutz}, language = {de} } @inproceedings{ButenwegKleemannAltayetal.2013, author = {Butenweg, Christoph and Kleemann, Anne and Altay, Okyay and Renault, Philippe}, title = {Simulation of impact-loads on reinforced concrete structural elements}, series = {22nd International Conference on Structural Mechanics in Reactor Technology 2013 : (SMiRT 22) ; San Francisco, California, USA, 18 - 23 August 2013}, booktitle = {22nd International Conference on Structural Mechanics in Reactor Technology 2013 : (SMiRT 22) ; San Francisco, California, USA, 18 - 23 August 2013}, organization = {International Conference on Structural Mechanics in Reactor Technology, SMIRT <22, 2013, San Francisco, Calif.>}, pages = {1 -- 10}, year = {2013}, language = {en} } @incollection{BorchertHeimannSchemm2011, author = {Borchert, J{\"o}rg and Heimann, Thorsten and Schemm, Ralf}, title = {Speicheroptimierung}, series = {Gashandel und Gasbeschaffung}, booktitle = {Gashandel und Gasbeschaffung}, publisher = {Euroforum Verl.}, address = {D{\"u}sseldorf}, publisher = {Fachhochschule Aachen}, pages = {1 -- 69}, year = {2011}, abstract = {In dieser Lektion wurden beginnend mit der Darstellung des fundamentalen Wandels des Gasmarktes die daraus folgenden Implikationen f{\"u}r die Einsatzweise von Gasspeichern abgeleitet. Anschließend wurden zwei Bewertungs- und Steuerungsverfahren f{\"u}r einen Gasspeicher an den beiden Marktstufen Termin- und Spotmarkt methodisch vorgestellt und anhand von Beispielrechnungen illustriert. Das Verfahren zur Bewertung und Steuerung im Terminmarkt stellt ein sehr robustes und methodisch einfaches Verfahren dar. Hierbei wird die Saisonalit{\"a}t der Forwardkurve bzw. deren Ver{\"a}nderungen arbitragefrei mithilfe des Speichers ausgenutzt. Dieses Verfahren kann nicht den gesamten Zeitwert des Speichers ausweisen. Es zieht in jedem Zeitpunkt nur die aktuellen Informationen der Forwardkurve zur Entscheidung heran. Es bildet aber keine bedingte Erwartung {\"u}ber zuk{\"u}nftige Ertr{\"a}ge und deren Beeinflussung durch die aktuelle Speicherfahrweise, um hieraus eine optimale Entscheidung zu formulieren. Bei der Bewertung gegen{\"u}ber dem Spotmarkt mithilfe der Least-Squares-Monte- Carlo-Simulation wird in einer stochastischen Optimierung dagegen der volle Zeitwert des Speichers und damit der gesamte Zusatznutzen der Flexibilit{\"a}t ermittelt. Hierdurch leiten sich auch wesentlich andere Hedging-Empfehlungen als im ersten Verfahren ab, um diesen zu sichern. Der Einsatz der beiden Verfahren im Alltag zur Bewirtschaftung des Speichers h{\"a}ngt insbesondere vom Know-how, den Speicherparametern und der Risikobereitschaft des Handels ab. Beide Strategien liefern hierzu Hedging-Empfehlungen ab, mit welchem der zugrunde liegende Wert gesichert werden kann. Risikoaverse H{\"a}ndler, die einen Großteil des inneren Wertes sichern wollen, k{\"o}nnten im Terminmarkt einen Großteil des Speichers mithilfe des „Intrinsic Rolling"-Verfahrens bewirtschaften. Sie w{\"u}rden hierdurch den saisonalen Spread in der Forwardkurve rollierend sichern. Gleichzeitig kann ein kleinerer Anteil mithilfe der stochastischen Optimierung und den damit verbundenen Aus{\"u}bungsgrenzen gegen{\"u}ber dem Spotmarkt bewirtschaftet werden. In einem liquiden vollst{\"a}ndigen Markt wird eine Steuerung des Speichers allein gegen{\"u}ber den vorhandenen Marktstufen vorgenommen und der Wert f{\"u}r alle Marktteilnehmer objektiv messbar. F{\"u}r den Fall, dass der Markt illiquide ist und hierdurch z. B. eine Kundenlast nicht allein am Termin- und Spotmarkt jederzeit gedeckt werden kann, erscheint es notwendig, den Speicher im Kontext einer Portfoliooptimierung zu bewerten. Dies wird in der n{\"a}chsten Lektion vorgenommen. Hierbei ist aber zu beachten, dass der Speicher dadurch eine individualisierte Wertkomponente erh{\"a}lt, die von der konkreten Ausgestaltung des jeweiligen Portfolios abh{\"a}ngt.}, language = {de} } @inproceedings{ChudobaButenwegKuhlmann2002, author = {Chudoba, Rostislav and Butenweg, Christoph and Kuhlmann, Wolfram}, title = {Technical information system for collaborative material research}, series = {Sixth International Conference on Computational Structures Technology : [Prague, Czech Republic, 4 - 6 September 2002]}, booktitle = {Sixth International Conference on Computational Structures Technology : [Prague, Czech Republic, 4 - 6 September 2002]}, organization = {International Conference on Computational Structures Technology <6, 2002, Prag>}, pages = {1 -- 11}, year = {2002}, language = {en} } @inproceedings{BruessermannDeuster2005, author = {Br{\"u}ssermann, Klaus and Deuster, M.}, title = {Temperature measurement to optimise the burning process}, year = {2005}, abstract = {One of the most important parameters in a burning chamber - in power stations, in waste to energy plants - is the temperature. This temperature is in the range of 700-1500 °C - one of the most advanced measuring methods being the acoustic pyrometry with the possibility of producing temperature mapping in one level of the burning chamber - comparable to computer tomography. The results of these measurements discussed in the presentation can be used - to fulfil the legal requirements in the FRG or in the EU - to equalise the temperature in one level of the burning chamber to optimise the steam production (better efficiency of the plant) and to minimise the production of temperature controlled flue gas components (NO, CO a. o.) - to control the SNCR-process if used.}, subject = {Pyrometrie}, language = {en} } @misc{Kaster2009, author = {Kaster, Jan Mathis}, title = {Untersuchungen zur Specklereduktion bei der Infrarot-Laser gest{\"u}tzten Ferndetektion von TNT-Oberfl{\"a}chenkontaminationen}, year = {2009}, abstract = {Das Ziel der vorliegenden Arbeit ist die Specklereduktion bei der Infrarotlaser-gest{\"u}tzten abbildenden Ferndetektion von TNT-Oberfl{\"a}chenkontaminationen. F{\"u}r die Detektion wird die Probenoberfl{\"a}che mit einem abstimmbaren Quantenkaskadenlaser bei verschiedenen Wellenzahlen im Spektralbereich von 1340cm-1 bis 1380cm-1 bestrahlt, w{\"a}hrend eine Infrarot-Kamera Bilder der bestrahlten Fl{\"a}che aufzeichnet. Diese Bilder werden dann so verarbeitet, dass im Ausgabebild die chemisch spezifische TNT-Absorption durch eine {\"A}nderung der Helligkeit {\"o}rtlich aufgel{\"o}st erkennbar werden. Da koh{\"a}rente Strahlung, welche beispielsweise an optisch rauen Oberfl{\"a}chen reflektiert wird, aufgrund der stochastischen Verteilung der Oberfl{\"a}chenrautiefe mit der einfallenden Strahlung lateral unterschiedlich interferiert, entsteht ein „Rauschen" in der aufgezeichneten Strahlungsleistungsverteilung, das sog. Speckle-Ph{\"a}nomen. Die Empfindlichkeit der oben skizzierten Lasergest{\"u}tzten Messtechnik wird im Wesentlichen durch diesen Effekt limitiert. Um die durch Laserspeckles verursachten Rauschanteile zu reduzieren, gibt es verschiedene M{\"o}glichkeiten. Durch Reduktion von zeitlicher und r{\"a}umlicher Koh{\"a}renz der Strahlung wird deren Interferenzf{\"a}higkeit reduziert und durch Variieren des Specklemusters w{\"a}hrend einer Bildaufzeichnung f{\"u}hren Mittelungen unkorrelierter Rauschanteile zu einer Specklekontrastreduktion. Letztere M{\"o}glichkeit resultiert daraus, dass Laserspeckles statistisch durch die Familie der Gammaverteilungen beschrieben werden k{\"o}nnen. Demnach verbessert sich das Signal-zu-Rausch-Verh{\"a}ltnis mit der Anzahl gemittelter, unkorrelierter Rauschmuster proportional zur Wurzel dieser Anzahl. Ein im MIR-Spektralbereich umsetzbarer Ansatz, der all diese M{\"o}glichkeiten ber{\"u}cksichtigt, wurde bereits 1971 von Lowenthal und Joyeaux vorgeschlagen und im Rahmen der vorliegenden Arbeit f{\"u}r den infraroten Spektralbereich adaptiert. Dazu wird die Strahlung mit zwei CVD-Diamant-Wafern moduliert; ein Wafer ist dabei station{\"a}r und der andere rotiert mit ca. 70Hz. In der vorliegenden Arbeit konnte mit diesem Ansatz eine Verbesserung des Signal-zu-Rausch-Verh{\"a}ltnisses in der betrachteten Strahlungsleistungs¬verteilung von urspr{\"u}nglich 3 auf etwa 45 erzielt werden. So konnten erstmals TNT-Kontaminationen von bis zu 10µg/cm² in einem Abstand von 5m abbildend nachgewiesen werden. Dies entspricht der Kontamination durch einen mit TNT leicht verunreinigten Fingerabdruck.}, subject = {Speckle}, language = {de} } @inproceedings{DielmannVelden2003, author = {Dielmann, Klaus-Peter and Velden, Alwin van der}, title = {Virtuelle Kraftwerke - Stand der Technik}, year = {2003}, abstract = {Ausgangslage, Funktionsprinzip des virtuellen Kraftwerkes, Energiemanagementsysteme (EMS), Einsatzgebiete, Anlagesysteme eines VKW's, Einsatzbereich der verschiedenen dezentralen Energieanlagen, Vorteile des virtuellen Kraftwerkes, Auswirkungen auf das elektrische Netz, Wirtschaftliche Aspekte, Beispielprojekte}, language = {de} } @article{KernKrichel2003, author = {Kern, Alexander and Krichel, Frank}, title = {{\"U}berlegungen zum Blitzschutzkonzept f{\"u}r regenerative Energieanlagen}, year = {2003}, abstract = {Dem Blitzschutz von Anlagen der regenerativen Energien kommt in Zukunft eine steigende Bedeutung zu. Dabei ist es notwendig zu ber{\"u}cksichtigen, dass die Schutzmaßnahmen technisch/wirtschaftlich ausgewogen sind. Erbauer, Besitzer oder Benutzer von netzautarken Hybridanlagen haben zu entscheiden, ob die Anlage einen Schutz braucht oder nicht. Um diese Entscheidung zu f{\"a}llen, ist eine Risikoanalyse als erster Schritt sinnvoll. Diese muss dabei die f{\"u}r die Hybridanlage relevanten Schadenarten und spezifischen Parameter, Werte und Randbedingungen mit einbeziehen. Dazu ist die Hilfe eines Blitzschutzexperten sehr hilfreich.}, subject = {Alternative Energiequelle}, language = {de} } @article{GeorgStollenwerkReinkensmeieretal.2021, author = {Georg, J{\"o}rg Heiner and Stollenwerk, Dominik and Reinkensmeier, Sebastian and Jungbluth, Christian}, title = {„Smartes" Laden an {\"o}ffentlich zug{\"a}nglichen Lades{\"a}ulen - Teil 1: Quo vadis, Marktdesign?}, series = {Energiewirtschaftliche Tagesfragen : et ; Zeitschrift f{\"u}r Energiewirtschaft, Recht, Technik und Umwelt}, volume = {71}, journal = {Energiewirtschaftliche Tagesfragen : et ; Zeitschrift f{\"u}r Energiewirtschaft, Recht, Technik und Umwelt}, number = {1/2}, publisher = {ETV Energieverlag}, address = {Essen}, isbn = {0720-6240}, issn = {0013-743X}, pages = {64 -- 69}, year = {2021}, language = {de} } @article{StollenwerkReinkensmeierGeorgetal.2021, author = {Stollenwerk, Dominik and Reinkensmeier, Sebastian and Georg, J{\"o}rg Heiner and Jungbluth, Christian}, title = {„Smartes" Laden an {\"o}ffentlich zug{\"a}nglichen Lades{\"a}ulen - Teil 2: USER-Verhalten und -Erwartungen}, series = {Energiewirtschaftliche Tagesfragen : et ; Zeitschrift f{\"u}r Energiewirtschaft, Recht, Technik und Umwelt}, volume = {71}, journal = {Energiewirtschaftliche Tagesfragen : et ; Zeitschrift f{\"u}r Energiewirtschaft, Recht, Technik und Umwelt}, number = {3}, publisher = {ETV Energieverlag}, address = {Essen}, isbn = {0720-6240}, issn = {0013-743X}, pages = {38 -- 42}, year = {2021}, language = {de} }