@techreport{DammAnthrakidisFend2015, author = {Damm, Marc Andr{\´e} and Anthrakidis, Anette and Fend, Thomas}, title = {Partikelminderungssystem mit einstellbarem Partikelr{\"u}ckhaltegrad : Varytrap : Schlussbericht : Laufzeit: 01.07.2010-28.02.2014}, address = {J{\"u}lich}, doi = {10.2314/GBV:848651863}, pages = {1 Online-Ressource (44 Seiten)}, year = {2015}, language = {de} } @techreport{DammAnthrakidisFend2016, author = {Damm, Marc Andr{\´e} and Anthrakidis, Anette and Fend, Thomas}, title = {Keramische Porenk{\"o}rpersysteme als SCR-Mischer und Hydrolysekatalysator : BMBF-Projekt: Hydromix : Schlussbericht : Laufzeit: 01.10.2011 bis 31.03.2015}, address = {Aachen}, pages = {30 Seiten : Illustrationen, Diagramme}, year = {2016}, language = {de} } @inproceedings{ElMoussaouiKassmiAlexopoulosetal.2021, author = {El Moussaoui, Noureddine and Kassmi, Khalil and Alexopoulos, Spiros and Schwarzer, Klemens and Chayeb, Hamid and Bachiri, Najib}, title = {Simulation studies on a new innovative design of a hybrid solar distiller MSDH alimented with a thermal and photovoltaic energy}, series = {Materialstoday: Proceedings}, volume = {45}, booktitle = {Materialstoday: Proceedings}, number = {8}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2214-7853}, doi = {10.1016/j.matpr.2021.03.115}, pages = {7653 -- 7660}, year = {2021}, abstract = {In this paper, we present the structure, the simulation the operation of a multi-stage, hybrid solar desalination system (MSDH), powered by thermal and photovoltaic (PV) (MSDH) energy. The MSDH system consists of a lower basin, eight horizontal stages, a field of four flat thermal collectors with a total area of 8.4 m2, 3 Kw PV panels and solar batteries. During the day the system is heated by thermal energy, and at night by heating resistors, powered by solar batteries. These batteries are charged by the photovoltaic panels during the day. More specifically, during the day and at night, we analyse the temperature of the stages and the production of distilled water according to the solar irradiation intensity and the electric heating power, supplied by the solar batteries. The simulations were carried out in the meteorological conditions of the winter month (February 2020), presenting intensities of irradiance and ambient temperature reaching 824 W/m2 and 23 °C respectively. The results obtained show that during the day the system is heated by the thermal collectors, the temperature of the stages and the quantity of water produced reach 80 °C and 30 Kg respectively. At night, from 6p.m. the system is heated by the electric energy stored in the batteries, the temperature of the stages and the quantity of water produced reach respectively 90 °C and 104 Kg for an electric heating power of 2 Kw. Moreover, when the electric power varies from 1 Kw to 3 Kw the quantity of water produced varies from 92 Kg to 134 Kg. The analysis of these results and their comparison with conventional solar thermal desalination systems shows a clear improvement both in the heating of the stages, by 10\%, and in the quantity of water produced by a factor of 3.}, language = {en} } @inproceedings{SattlerCaminosUerlingsetal.2020, author = {Sattler, Johannes, Christoph and Caminos, Ricardo Alexander Chico and {\"U}rlings, Nicolas and Dutta, Siddharth and Ruiz, Victor and Kalogirou, Soteris and Ktistis, Panayiotis and Agathokleous, Rafaela and Jung, Christian and Alexopoulos, Spiros and Atti, Vikrama Nagababu and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Operational experience and behaviour of a parabolic trough collector system with concrete thermal energy storage for process steam generation in Cyprus}, series = {AIP Conference Proceedings}, booktitle = {AIP Conference Proceedings}, number = {2303}, doi = {10.1063/5.0029278}, pages = {140004-1 -- 140004-10}, year = {2020}, abstract = {As part of the transnational research project EDITOR, a parabolic trough collector system (PTC) with concrete thermal energy storage (C-TES) was installed and commissioned in Limassol, Cyprus. The system is located on the premises of the beverage manufacturer KEAN Soft Drinks Ltd. and its function is to supply process steam for the factory's pasteurisation process [1]. Depending on the factory's seasonally varying capacity for beverage production, the solar system delivers between 5 and 25 \% of the total steam demand. In combination with the C-TES, the solar plant can supply process steam on demand before sunrise or after sunset. Furthermore, the C-TES compensates the PTC during the day in fluctuating weather conditions. The parabolic trough collector as well as the control and oil handling unit is designed and manufactured by Protarget AG, Germany. The C-TES is designed and produced by CADE Soluciones de Ingenier{\´i}a, S.L., Spain. In the focus of this paper is the description of the operational experience with the PTC, C-TES and boiler during the commissioning and operation phase. Additionally, innovative optimisation measures are presented.}, language = {en} } @inproceedings{RendonSchwagerGhiasietal.2020, author = {Rendon, Carlos and Schwager, Christian and Ghiasi, Mona and Schmitz, Pascal and Bohang, Fakhri and Caminos, Ricardo Alexander Chico and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Modeling and upscaling of a pilot bayonettube reactor for indirect solar mixed methane reforming}, series = {AIP Conference Proceedings}, booktitle = {AIP Conference Proceedings}, number = {2303}, doi = {10.1063/5.0029974}, pages = {170012-1 -- 170012-9}, year = {2020}, abstract = {A 16.77 kW thermal power bayonet-tube reactor for the mixed reforming of methane using solar energy has been designed and modeled. A test bench for the experimental tests has been installed at the Synlight facility in Juelich, Germany and has just been commissioned. This paper presents the solar-heated reactor design for a combined steam and dry reforming as well as a scaled-up process simulation of a solar reforming plant for methanol production. Solar power towers are capable of providing large amounts of heat to drive high-endothermic reactions, and their integration with thermochemical processes shows a promising future. In the designed bayonet-tube reactor, the conventional burner arrangement for the combustion of natural gas has been substituted by a continuous 930 °C hot air stream, provided by means of a solar heated air receiver, a ceramic thermal storage and an auxiliary firing system. Inside the solar-heated reactor, the heat is transferred by means of convective mechanism mainly; instead of radiation mechanism as typically prevailing in fossil-based industrial reforming processes. A scaled-up solar reforming plant of 50.5 MWth was designed and simulated in Dymola® and AspenPlus®. In comparison to a fossil-based industrial reforming process of the same thermal capacity, a solar reforming plant with thermal storage promises a reduction up to 57 \% of annual natural gas consumption in regions with annual DNI-value of 2349 kWh/m2. The benchmark solar reforming plant contributes to a CO2 avoidance of approx. 79 kilotons per year. This facility can produce a nominal output of 734.4 t of synthesis gas and out of this 530 t of methanol a day.}, language = {en} } @inproceedings{OetringerDuemmlerGoettsche2020, author = {Oetringer, Kerstin and D{\"u}mmler, Andreas and G{\"o}ttsche, Joachim}, title = {Neues Modell zur 1D-Simulation der indirekten Verdunstungsk{\"u}hlung}, series = {DKV-Tagung 2020, AA II.1}, booktitle = {DKV-Tagung 2020, AA II.1}, pages = {250 -- 262}, year = {2020}, abstract = {Im Projekt Coolplan- AIR geht es um die Fortentwicklung und Feld- Validierung eines Berechnungs- und Auslegungstools zur energieeffizienten K{\"u}hlung von Geb{\"a}uden mit luftgest{\"u}tzten Systemen. Neben dem Aufbau und der Weiterentwicklung von Simulationsmodellen erfolgen Vermessungen der Gesamtsysteme anhand von Praxisanlagen im Feld. Eine der betrachteten Anlagen arbeitet mit indirekter Verdunstung. Diese Ver{\"o}ffentlichung zeigt den Entwicklungsprozess und den Aufbau des Simulationsmodells zur Verdunstungsk{\"u}hlung in der Simulationsumgebung Matlab- Simulink mit der CARNOT- Toolbox. Das besondere Augenmerk liegt dabei auf dem physikalischen Modell des W{\"a}rme{\"u}bertragers, in dem die Verdunstung implementiert ist. Dem neuen Modellansatz liegt die Annahme einer aus der Enthalpie- Betrachtung hergeleiteten effektiven W{\"a}rmekapazit{\"a}t zugrunde. Des Weiteren wird der Befeuchtungsgrad als konstant angesehen und eine standardisierte Zunahme der W{\"a}rme{\"u}bertragung des feuchten gegen{\"u}ber dem trockenen W{\"a}rme{\"u}bertrager angenommen. Die Validierung des Modells erfolgte anhand von Literaturdaten. F{\"u}r den trockenen W{\"a}rmetauscher ist der maximale absolute Fehler der berechneten Austrittstemperatur (Zuluft) kleiner als ±0.1 K und f{\"u}r den nassen W{\"a}rmetauscher (K{\"u}hlfall) unter der Annahme eines konstanten Verdunstungsgrades kleiner als ±0.4 K.}, language = {de} } @inproceedings{DuemmlerOetringerGoettsche2020, author = {D{\"u}mmler, Andreas and Oetringer, Kerstin and G{\"o}ttsche, Joachim}, title = {Auslegungstool zur energieeffizienten K{\"u}hlung von Geb{\"a}uden}, series = {DKV-Tagung 2020, AA IV}, booktitle = {DKV-Tagung 2020, AA IV}, pages = {1109}, year = {2020}, abstract = {Thematisch widmet sich das Projekt Coolplan- AIR der Fortentwicklung und Feldvalidierung eines Berechnungs- und Auslegungstools zur energieeffizienten K{\"u}hlung von Geb{\"a}uden mit luftgest{\"u}tzten Systemen. Neben dem Aufbau und der Weiterentwicklung von Simulationsmodellen erfolgen Vermessungen der Gesamtsysteme anhand von Praxisanlagen im Feld. Der Schwerpunkt des Projekts liegt auf der Vermessung, Simulation und Integration rein luftgest{\"u}tzter K{\"u}hltechnologien. Im Bereich der K{\"a}lteerzeugung wurden Luft- Luft- W{\"a}rmepumpen, Anlagen zur adiabaten K{\"u}hlung bzw. offene K{\"u}hlt{\"u}rme und VRF- Multisplit- Systeme (Variable Refrigerant Flow) im Feld bzw. auf dem Teststand der HSD vermessen. Die Komponentenmodelle werden in die Matlab/Simulink- Toolbox CARNOT integriert und anschließend auf Basis der zuvor erhaltenen Messdaten validiert. Einerseits erlauben die Messungen das Betriebsverhalten von Anlagenkomponenten zu analysieren. Andererseits soll mit der Vermessung im Feld gepr{\"u}ft werden, inwieweit die Simulationsmodelle, welche im Vorg{\"a}ngerprojekt aus Pr{\"u}fstandmessungen entwickelt wurden, auch f{\"u}r gr{\"o}ßere Ger{\"a}teleistungen G{\"u}ltigkeit besitzen. Die entwickelten und implementierten Systeme, bestehend aus verschiedensten Anlagenmodellen und Regelungskomponenten, werden gepr{\"u}ft und dahingehend qualifiziert, dass sie in Standard- Auslegungstools zuverl{\"a}ssig verwendet werden k{\"o}nnen. Zus{\"a}tzlich wird ein energetisches Monitoring eines H{\"o}rsaalgeb{\"a}udes am Campus J{\"u}lich durchgef{\"u}hrt, das u. a. zur Validierung der K{\"u}hllastberechnungen in g{\"a}ngigen Simulationsmodelle genutzt werden kann.}, language = {de} } @article{GoettscheAlexopoulosDuemmleretal.2019, author = {G{\"o}ttsche, Joachim and Alexopoulos, Spiros and D{\"u}mmler, Andreas and Maddineni, S. K.}, title = {Multi-Mirror Array Calculations With Optical Error}, pages = {1 -- 6}, year = {2019}, abstract = {The optical performance of a 2-axis solar concentrator was simulated with the COMSOL Multiphysics® software. The concentrator consists of a mirror array, which was created using the application builder. The mirror facets are preconfigured to form a focal point. During tracking all mirrors are moved simultaneously in a coupled mode by 2 motors in two axes, in order to keep the system in focus with the moving sun. Optical errors on each reflecting surface were implemented in combination with the solar angular cone of ± 4.65 mrad. As a result, the intercept factor of solar radiation that is available to the receiver was calculated as a function of the transversal and longitudinal angles of incidence. In addition, the intensity distribution on the receiver plane was calculated as a function of the incidence angles.}, language = {en} } @techreport{GhinaiyaLehmannGoettsche2022, author = {Ghinaiya, Jagdishkumar and Lehmann, Thomas and G{\"o}ttsche, Joachim}, title = {LOCAL+ - ein kreislauff{\"a}higer Holzmodulbau mit nachhaltigem Energie- und Wohnraumkonzept}, series = {Bauphysik}, volume = {44}, journal = {Bauphysik}, number = {3}, publisher = {Ernst \& Sohn}, address = {Hoboken}, issn = {0171-5445 (Print)}, doi = {10.1002/bapi.202200010}, pages = {136 -- 142}, year = {2022}, abstract = {Mit dem Beitrag des Teams der FH Aachen zum SDE 21/22 wird im Projekt LOCAL+ ein kreislauff{\"a}higer Holzmodulbau mit einem innovativen Wohnraumkonzept geplant und umgesetzt. Ziel dieses Konzeptes ist die Verringerung des stetig steigenden Wohnfl{\"a}chenbedarfs durch ein Raum-in-Raum Konzept. Geb{\"a}udetechnisch wird in dem Projekt nicht nur das Einzelgeb{\"a}ude betrachtet, sondern unter Ber{\"u}cksichtigung des Geb{\"a}udebestandes wird f{\"u}r das Quartier ein innovatives und nachhaltiges Energiekonzept entwickelt. Ein zentrales Wasserstoffsystem ist f{\"u}r ein Quartier geplant, um den Stromverbrauch aus dem Netz im Winter zu reduzieren. Zentraler Bestandteil des TGA-Konzepts ist ein unterirdischer Eisspeicher, eine PVT und eine W{\"a}rmepumpe mit intelligenter Regelstrategie. Ein Teil des neuen Geb{\"a}udes (Design Challenge DC) wird in Wuppertal als Hausdemonstrationseinheit (HDU) pr{\"a}sentiert. Eine hygrothermische Simulation der HDU wurde mit der WUFI-Software durchgef{\"u}hrt. Da im Innenraum Lehmmodule und -platten als Feuchtigkeitspuffer verwendet werden, spielen die Themen Feuchtigkeit, Holzf{\"a}ule und Schimmelwachstum eine wichtige Rolle.}, language = {de} } @article{GorzalkaSchmiedtSchorn2021, author = {Gorzalka, Philip and Schmiedt, Jacob Estevam and Schorn, Christian}, title = {Automated Generation of an Energy Simulation Model for an Existing Building from UAV Imagery}, series = {Buildings}, volume = {11}, journal = {Buildings}, number = {9}, publisher = {MDPI}, address = {Basel}, issn = {2075-5309}, doi = {10.3390/buildings11090380}, pages = {15 Seiten}, year = {2021}, abstract = {An approach to automatically generate a dynamic energy simulation model in Modelica for a single existing building is presented. It aims at collecting data about the status quo in the preparation of energy retrofits with low effort and costs. The proposed method starts from a polygon model of the outer building envelope obtained from photogrammetrically generated point clouds. The open-source tools TEASER and AixLib are used for data enrichment and model generation. A case study was conducted on a single-family house. The resulting model can accurately reproduce the internal air temperatures during synthetical heating up and cooling down. Modelled and measured whole building heat transfer coefficients (HTC) agree within a 12\% range. A sensitivity analysis emphasises the importance of accurate window characterisations and justifies the use of a very simplified interior geometry. Uncertainties arising from the use of archetype U-values are estimated by comparing different typologies, with best- and worst-case estimates showing differences in pre-retrofit heat demand of about ±20\% to the average; however, as the assumptions made are permitted by some national standards, the method is already close to practical applicability and opens up a path to quickly estimate possible financial and energy savings after refurbishment.}, language = {en} } @article{PeereBlanke2022, author = {Peere, Wouter and Blanke, Tobias}, title = {GHEtool: An open-source tool for borefield sizing in Python}, series = {Journal of Open Source Software}, volume = {7}, journal = {Journal of Open Source Software}, number = {76}, editor = {Vernon, Chris}, issn = {2475-9066}, doi = {10.21105/joss.04406}, pages = {1 -- 4, 4406}, year = {2022}, abstract = {GHEtool is a Python package that contains all the functionalities needed to deal with borefield design. It is developed for both researchers and practitioners. The core of this package is the automated sizing of borefield under different conditions. The sizing of a borefield is typically slow due to the high complexity of the mathematical background. Because this tool has a lot of precalculated data, GHEtool can size a borefield in the order of tenths of milliseconds. This sizing typically takes the order of minutes. Therefore, this tool is suited for being implemented in typical workflows where iterations are required. GHEtool also comes with a graphical user interface (GUI). This GUI is prebuilt as an exe-file because this provides access to all the functionalities without coding. A setup to install the GUI at the user-defined place is also implemented and available at: https://www.mech.kuleuven.be/en/tme/research/thermal_systems/tools/ghetool.}, language = {en} } @inproceedings{BlankeSchmidtGoettscheetal.2022, author = {Blanke, Tobias and Schmidt, Katharina S. and G{\"o}ttsche, Joachim and D{\"o}ring, Bernd and Frisch, J{\´e}r{\^o}me and van Treeck, Christoph}, title = {Time series aggregation for energy system design: review and extension of modelling seasonal storages}, series = {Energy Informatics}, volume = {5}, booktitle = {Energy Informatics}, number = {1, Article number: 17}, editor = {Weidlich, Anke and Neumann, Dirk and Gust, Gunther and Staudt, Philipp and Sch{\"a}fer, Mirko}, publisher = {Springer Nature}, issn = {2520-8942}, doi = {10.1186/s42162-022-00208-5}, pages = {14 Seiten}, year = {2022}, abstract = {Using optimization to design a renewable energy system has become a computationally demanding task as the high temporal fluctuations of demand and supply arise within the considered time series. The aggregation of typical operation periods has become a popular method to reduce effort. These operation periods are modelled independently and cannot interact in most cases. Consequently, seasonal storage is not reproducible. This inability can lead to a significant error, especially for energy systems with a high share of fluctuating renewable energy. The previous paper, "Time series aggregation for energy system design: Modeling seasonal storage", has developed a seasonal storage model to address this issue. Simultaneously, the paper "Optimal design of multi-energy systems with seasonal storage" has developed a different approach. This paper aims to review these models and extend the first model. The extension is a mathematical reformulation to decrease the number of variables and constraints. Furthermore, it aims to reduce the calculation time while achieving the same results.}, language = {en} } @article{GrossTimmer1998, author = {Groß, Rolf Fritz and Timmer, H.}, title = {Energetische und betriebswirtschaftliche Bewertung von K{\"u}hlsystemen f{\"u}r K{\"u}hllager}, series = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, volume = {49}, journal = {HLH. Heizung, L{\"u}ftung/Klima, Haustechnik}, number = {9}, publisher = {Springer}, address = {D{\"u}sseldorf}, issn = {1436-5103}, pages = {74 -- 77}, year = {1998}, language = {de} } @incollection{ThulfautGrossRenz2000, author = {Thulfaut, Christian and Groß, Rolf Fritz and Renz, Ulrich}, title = {Messwerterfassung und -auswertung mit LabView: Experimentelle Analyse der Mischungsg{\"u}te in Hybridzellenk{\"u}hlt{\"u}rmen}, series = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000}, booktitle = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000}, editor = {Jamal, Rahman and Jaschinski, Hans}, publisher = {H{\"u}thig}, address = {Heidelberg}, isbn = {3-7785-2789-4 (print)}, pages = {54 -- 60}, year = {2000}, abstract = {Zur K{\"u}hlung von Abw{\"a}rmestr{\"o}men aus Kraftwerksprozessen werden in zunehmenden Maße Hybridzellenk{\"u}hlt{\"u}rme mit Zwangskonvektion eingesetzt, deren wesentlicher Vorteil ihre geringe Bauh{\"o}he ist. Um bei derartigen K{\"u}hlt{\"u}rmen eine Sichtbehinderung oder Glatteisgef{\"a}hrdung durch bodennahen Nebel zu vermeiden, muss durch eine optimale Vermischung des Trocken- und Naßluftanteils gew{\"a}hrleistet sein, daß aus der K{\"u}hlturmkrone keine Nebelschwaden austreten. In Zusammenarbeit mit der Industrie betreibt der Lehrstuhl f{\"u}r W{\"a}rme{\"u}bertragung und Klimatechnik der RWTH Aachen einen Versuchsstand zur Erfassung der Mischungsg{\"u}te in Hybridzellenk{\"u}hlt{\"u}rmen. In maßstabsgerechter Nachbildung k{\"o}nnen dabei am Modell alle relevanten Einflußgr{\"o}ßen wie K{\"u}hlturmgeometrie, Gestaltung zus{\"a}tzlicher Mischeinbauten sowie die Betriebsparameter variiert werden. Mit Hilfe einer unter LabView 5.01 erstellten Software werden sowohl die l3etriebszust{\"u}ncle online {\"u}berwacht, als auch die ben{\"o}tigten Meßwerte zur Bestimmung der Mischungsg{\"u}te erfaßt. {\"U}ber die grafische Oberfl{\"a}che k{\"o}nnen s{\"a}mtliche Meßoptionen gesteuert sowie alle Meßdaten visualisiert und kontrolliert werden. In das LabView-Programm sind dar{\"u}ber hinaus Routinen zur Auswertung der Daten implementiert worden, die sowohl eine direkte Darstellung der Ergebnisse in Form von Diagrammen erm{\"o}glichen, als auch zur Weiterverarbeitung einen Datenexport in eine Microsoft- Excel-Tabelle vorsehen.}, language = {de} } @incollection{GrossThulfautRenz2000, author = {Groß, Rolf Fritz and Thulfaut, Christian and Renz, Ulrich}, title = {On-Line Simulation mit LabView: Experimentelle und numerische Analyse homogener Gasphasenreaktionen aus Kraftwerksprozessen,}, series = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000}, booktitle = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000}, editor = {Jamal, Rahman and Jaschinski, Hans}, publisher = {H{\"u}thig}, address = {Heidelberg}, isbn = {3-7785-2789-4 (print)}, pages = {103 -- 108}, year = {2000}, abstract = {The institute of heat transfer and air conditioning at the Aachen University of Technology operates several test facilities in order to investigate homogeneous and catalytical processes for the reduction of gaseous pollutants (e.g. nitrous oxide) of flue gases in a tempeature range up to 900°C. One test facility consists of a stainless steel reactor in which the influence of reducing additives can be investigated. The software tool, created with LabVIEW 5.01, offers the possibility to measure, visualize and control all relevant physical quantities and to gain a numerical solution of the problem by solving the one dimensional, steady state conservation equations.}, language = {de} } @techreport{ChristGrossRenz1998, author = {Christ, Ansgar and Groß, Rolf Fritz and Renz, Ulrich}, title = {Str{\"o}mungs-, Filterkuchen- und Abreinigungsmodelle f{\"u}r Heißgasfilter, Teilvorhaben "Numerische Simulation des Abreinigungsvorganges und der Rohgasstr{\"o}mung"}, doi = {10.2314/GBV:50431601X}, pages = {117 Seiten}, year = {1998}, language = {de} } @incollection{DautzenbergGrossRenz1996, author = {Dautzenberg, H. and Groß, Rolf Fritz and Renz, Ulrich}, title = {Meßtechnik auf dem Pr{\"u}fstand: Forschung zur Heißgasfiltration}, series = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 1996}, booktitle = {Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 1996}, editor = {Jamal, Rahman}, publisher = {National Instruments Germany}, address = {M{\"u}nchen}, pages = {202 -- 208}, year = {1996}, abstract = {Im Rahmen von Forschungsvorhaben des BMBF und verschiedener Industriepartner betreibt der Lehrstuhl f{\"u}r W{\"a}rme{\"u}bertragung und Klimatechnik der RWTH Aachen Pilotanlagen und Pr{\"u}fst{\"a}nde f{\"u}r Untersuchungen auf dem Gebiet der Heißgasfiltration mit keramischen Filterelementen. Als wesentlicher Garant f{\"u}r den Erfolg der Forschungsarbeit muß die auf das jeweilige Projekt genau abgestimmte Meß- und Regelungstechnik angesehen werden. Hierbei z{\"a}hlt neben der Auswahl geeigneter Hardwarekomponenten auch die Softwareentwicklung unter einer leistungsstarken und zuverl{\"a}ssigen Programmierumgebung. Anhand des Aufbaus dreier Versuchsanlagen im Technikumsmaßstab soll das Anforderungsprofil an die Meßtechnik bis hin zur Umsetzung innerhalb der Anlage skizziert werden. Der Heißgasfiltrationspr{\"u}fstand im Heizkraftwerk der RWTH Aachen dient der Beobachtung des Reinigungsverhaltens keramischer Filterelemente bei der Heißgasentstaubung im Temperaturbereich bis 850 Grad C. Wesentlich f{\"u}r die Meßwerterfassung ist hierbei die Kopplung eines Orion-Datenloggers der Firma Schlumberger mit LabView 4.0. Im Hochtemperaturofen des Lehrstuhls werden instation{\"a}re Druckmessungen an einer keramischen Filterkerze w{\"a}hrend eines Abreinigungsimpulses bei 950 Grad C mit hoher Samplingrate durchgef{\"u}hrt. Hierbei {\"u}bernimmt eine durch LabView 4.0 angesteuerte E-Series Karte der Firma National Instruments die Signalaufnahme. Die katalytische Schadstoffreduktion und Entstaubung heißer Rauchgase bei 900 Grad C sind Ziele der Untersuchungen in einer erstellten Versuchsanlage mit einem Quarzglasreaktor. Die Signalerfassung und -konditionierung erfolgt {\"u}ber SCXI in Verbindung mit LabView 4.0, die Steuerung der Anlage {\"u}bernehmen zwei Multifunktionskarten (National Instruments).}, language = {de} } @incollection{GrossMuellerHertingetal.1997, author = {Groß, Rolf Fritz and M{\"u}ller, D. and Herting, D. and Schneemann, A. and Renz, Ulrich}, title = {Modulare Messdatenerfassung in Forschung und Lehre}, series = {Virtuelle Instrumente in der Praxis : Begleitband zum Kongress VIP '97}, booktitle = {Virtuelle Instrumente in der Praxis : Begleitband zum Kongress VIP '97}, editor = {Rahman, Jamal and Jaschinski, Hans}, publisher = {H{\"u}thig}, address = {Heidelberg}, isbn = {978-3-7785-2667-5 Pp.}, pages = {282 -- 288}, year = {1997}, abstract = {The Lehrstuhl f{\"u}r W{\"a}rme{\"u}bertragung und Klimatechnik at the Aachen University of Technology operates several test facilities to investigate fundamentals of heat and mass transfer supported by the Deutsche Forschungsgemeinschaft, the Minister f{\"u}r Forschung und Technologie and the industry. In order to get high-resolution and reproselection of hardware components is as critical as the design of software routines to perform successful and accurate measurements. In the following the development of the measurement and control system for three different test facilities is presented and discussed. Special attention is given to the education of students within the framework of laboratories and scientific experiments.}, language = {de} } @inproceedings{SchulzeBuxlohGrossUlbrich2021, author = {Schulze-Buxloh, Lina and Groß, Rolf Fritz and Ulbrich, Michelle}, title = {Digital planning using building information modelling and virtual reality: new approach for students' remote practical training under lockdown conditions in the course of smart building engineering}, series = {Proceedings of International Conference on Education in Mathematics, Science and Technology 2021}, booktitle = {Proceedings of International Conference on Education in Mathematics, Science and Technology 2021}, publisher = {ISTES Organization}, address = {San Antonio, TX}, isbn = {978-1-952092-17-6}, pages = {118 -- 123}, year = {2021}, abstract = {The worldwide Corona pandemic has severely restricted student projects in the higher semesters of engineering courses. In order not to delay the graduation, a new concept had to be developed for projects under lockdown conditions. Therefore, unused rooms at the university should be digitally recorded in order to develop a new usage concept as laboratory rooms. An inventory of the actual state of the rooms was done first by taking photos and listing up all flaws and peculiarities. After that, a digital site measuring was done with a 360° laser scanner and these recorded scans were linked to a coherent point cloud and transferred to a software for planning technical building services and supporting Building Information Modelling (BIM). In order to better illustrate the difference between the actual and target state, two virtual reality models were created for realistic demonstration. During the project, the students had to go through the entire digital planning phases. Technical specifications had to be complied with, as well as documentation, time planning and cost estimate. This project turned out to be an excellent alternative to on-site practical training under lockdown conditions and increased the students' motivation to deal with complex technical questions.}, language = {en} } @inproceedings{DuranParedesMottaghyHerrmannetal.2020, author = {Duran Paredes, Ludwin and Mottaghy, Darius and Herrmann, Ulf and Groß, Rolf Fritz}, title = {Online ground temperature and soil moisture monitoring of a shallow geothermal system with non-conventional components}, series = {EGU General Assembly 2020}, booktitle = {EGU General Assembly 2020}, year = {2020}, abstract = {We present first results from a newly developed monitoring station for a closed loop geothermal heat pump test installation at our campus, consisting of helix coils and plate heat exchangers, as well as an ice-store system. There are more than 40 temperature sensors and several soil moisture content sensors distributed around the system, allowing a detailed monitoring under different operating conditions.In the view of the modern development of renewable energies along with the newly concepts known as Internet of Things and Industry 4.0 (high-tech strategy from the German government), we created a user-friendly web application, which will connect the things (sensors) with the open network (www). Besides other advantages, this allows a continuous remote monitoring of the data from the numerous sensors at an arbitrary sampling rate.Based on the recorded data, we will also present first results from numerical simulations, taking into account all relevant heat transport processes.The aim is to improve the understanding of these processes and their influence on the thermal behavior of shallow geothermal systems in the unsaturated zone. This will in turn facilitate the prediction of the performance of these systems and therefore yield an improvement in their dimensioning when designing a specific shallow geothermal installation.}, language = {en} }