@article{ParlLarueStreunetal.2011, author = {Parl, C. and Larue, H. and Streun, M. and Ziemons, Karl}, title = {Double-side-readout technique for SiPM-matrices}, series = {2010 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, journal = {2010 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, publisher = {IEEE}, address = {New York}, issn = {1095-7863}, pages = {1486 -- 1487}, year = {2011}, abstract = {In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit.}, language = {en} } @article{KirchnerOberlaenderSusoetal.2013, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Suso, Henri-Pierre and Rysstad, Gunnar and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes}, series = {Physica status solidi (a)}, volume = {210}, journal = {Physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201200920}, pages = {877 -- 883}, year = {2013}, abstract = {A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests.}, language = {en} } @article{StreunBrandenburgLarueetal.2006, author = {Streun, M. and Brandenburg, G. and Larue, H. and Parl, C. and Ziemons, Karl}, title = {The data acquisition system of ClearPET neuro - a small animal PET scanner}, series = {IEEE Transactions on Nuclear Science}, volume = {53}, journal = {IEEE Transactions on Nuclear Science}, number = {3}, isbn = {0018-9499}, pages = {700 -- 703}, year = {2006}, abstract = {The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in J{\"u}lich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system.}, language = {en} } @article{KhodaverdiWeberStreunetal.2006, author = {Khodaverdi, M. and Weber, S. and Streun, M. and Parl, C. and Ziemons, Karl}, title = {High resolution imaging with ClearPET™ Neuro - first animal images}, series = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, journal = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, isbn = {1082-3654}, pages = {1641 -- 1644}, year = {2006}, abstract = {The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance.}, language = {en} } @article{StreunBrandenburgKhodaverdietal.2006, author = {Streun, M. and Brandenburg, G. and Khodaverdi, M. and Larue, H. and Parl, C. and Ziemons, Karl}, title = {Timemark correction for the ClearPET™ scanners}, series = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4}, journal = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4}, isbn = {1082-3654}, pages = {2057 -- 2060}, year = {2006}, abstract = {The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented}, language = {en} } @article{MiyamotoIchimuraWagneretal.2013, author = {Miyamoto, Ko-ichiro and Ichimura, Hiroki and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel}, series = {Sensors and actuators. B: Chemical}, volume = {189}, journal = {Sensors and actuators. B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077 (E-Journal); 0925-4005 (Print)}, doi = {10.1016/j.snb.2013.04.057}, pages = {240 -- 245}, year = {2013}, abstract = {The chemical imaging sensor is a device to visualize the spatial distribution of chemical species based on the principle of LAPS (light-addressable potentiometric sensor), which is a field-effect chemical sensor based on semiconductor. In this study, the chemical imaging sensor has been applied to investigate the ion profile of laminar flows in a microfluidic channel. The chemical images (pH maps) were collected in a Y-shaped microfluidic channel while injecting HCl and NaCl solutions into two branches. From the chemical images, it was clearly observed that the injected solutions formed laminar flows in the channel. In addition, ion diffusion across the laminar flows was observed, and the diffusion coefficient could be derived by fitting the pH profiles to the Fick's equation.}, language = {en} } @article{BohrnMuchaWerneretal.2013, author = {Bohrn, Ulrich and Mucha, Andreas and Werner, Frederik and Trattner, Barbara and B{\"a}cker, Matthias and Krumbe, Christoph and Schienle, Meinrad and St{\"u}tz, Evamaria and Schmitt-Landsiedel, Doris and Fleischer, Maximilian and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {A critical comparison of cell-based sensor systems for the detection of Cr (VI) in aquatic environment}, series = {Sensors and actuators. B: Chemical}, volume = {Vol. 182}, journal = {Sensors and actuators. B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077 (E-Journal); 0925-4005 (Print)}, pages = {58 -- 65}, year = {2013}, language = {en} } @article{TemizArtmannKayatekinUysaletal.2005, author = {Temiz Artmann, Ayseg{\"u}l and Kayatekin, Muammer B. and Uysal, N. and Resmi, H.}, title = {Does antioxidant supplementation alter the effects of acute exercise on erythrocyte aggregation, deformability and endothelium adhesion in untrained rats? Kayatekin, Muammer B.; Uysal N.; Resmi, H.; Bediz, Seref C.; Temiz Artmann, A.; Gen{\c{c}}, S.; Tugyan, K.}, series = {International Journal for Vitamin and Nutrition Research. 75 (2005), H. 4}, journal = {International Journal for Vitamin and Nutrition Research. 75 (2005), H. 4}, isbn = {0300-9831}, pages = {243 -- 250}, year = {2005}, language = {en} } @article{TemizArtmannResmiAkhunlaretal.2005, author = {Temiz Artmann, Ayseg{\"u}l and Resmi, Halil and Akhunlar, H{\"u}lya and G{\"u}ner, G{\"u}l}, title = {In vitro effects of high glucose concentrations on membrane protein sulfhydryl oxidation, G-actin and deformability of human erythrocytes. Resmi, Halil ; Akhunlar, H{\"u}lya ; Temiz Artmann, Ayseg{\"u}l ; G{\"u}ner, G{\"u}l}, series = {Cell biochemistry and function. 23 (2005), H. 3}, journal = {Cell biochemistry and function. 23 (2005), H. 3}, isbn = {0263-6484}, pages = {163 -- 168}, year = {2005}, language = {en} } @article{TemizArtmannCavdarYeniceriogluetal.2003, author = {Temiz Artmann, Ayseg{\"u}l and Cavdar, C. and Yenicerioglu, Y. and Caliskan, S.}, title = {The effects of intravenous iron treatment on oxidant stress and erythrocyte deformability in haemodialysis patients. Cavdar, C.; Temiz, A.; Yenicerioglu, Y.; Caliskan, S.; Celik, A.; Sifil, A.; Onvural, B.; Camsari, T.}, series = {Scandinavian Journal of Urology and Nephrology. 37 (2003), H. 1}, journal = {Scandinavian Journal of Urology and Nephrology. 37 (2003), H. 1}, isbn = {0036-5599}, pages = {77 -- 82}, year = {2003}, language = {en} } @article{TemizArtmannYolcuogluOnaletal.1999, author = {Temiz Artmann, Ayseg{\"u}l and Yolcuoglu, B. and Onal, M. A. and Sipahi, O.}, title = {The effect of skin transplantation on tumour growth in mice. Yolcuoglu, B.; Onal, M. A.; Sipahi, O.; Temiz, A.; Pekcetin, C.; Acikg{\"o}z, O.; Kar, H.; G{\"u}re A.}, series = {The American Journal of Surgery. 178 (1999), H. 4}, journal = {The American Journal of Surgery. 178 (1999), H. 4}, isbn = {0002-9610}, pages = {329 -- 330}, year = {1999}, language = {en} } @article{TemizArtmannAtesUeretmenetal.1998, author = {Temiz Artmann, Ayseg{\"u}l and Ates, H. and {\"U}retmen, {\"O}. and Andac, K.}, title = {Erythrocyte deformability in high-tension and normal tension glaucoma. Ates, H.; {\"U}retmen, {\"O}.; Temiz, A.; Andac, K.}, series = {International Ophthalmology. 22 (1998), H. 1}, journal = {International Ophthalmology. 22 (1998), H. 1}, isbn = {0165-5701}, pages = {7 -- 12}, year = {1998}, language = {en} } @article{TemizArtmannAkhisarogluSercanetal.2005, author = {Temiz Artmann, Ayseg{\"u}l and Akhisaroglu, M. and Sercan, Z. and Kayatekin, B. M.}, title = {Adhesion of Erythrocytes to Endothelial Cells After Acute Exercise: Differences in Red Blood Cells from Juvenile and Adult Rats. Temiz Artmann, A.; Akhisaroglu, M.; Sercan, Z.; Kayatekin, BM.; Yorukoglu, K.; Kirkali, G.}, series = {Physiological Research (2005)}, journal = {Physiological Research (2005)}, isbn = {0862-8408}, year = {2005}, language = {en} } @article{PawelkeButzer1968, author = {Pawelke, Siegfried and Butzer, Paul L.}, title = {Semi-groups and resolvent operators}, series = {Archive for Rational Mechanics and Analysis}, volume = {30}, journal = {Archive for Rational Mechanics and Analysis}, number = {2}, publisher = {Springer}, address = {Berlin}, issn = {0003-9527}, doi = {10.1007/BF00250941}, pages = {127 -- 147}, year = {1968}, language = {en} } @article{Pawelke1980, author = {Pawelke, Siegfried}, title = {Weak smoothness conditions for the uniform convergence of Fourier-Jacobi series}, series = {Functiones et Approximatio. Commentarii Mathematici. 9 (1980)}, journal = {Functiones et Approximatio. Commentarii Mathematici. 9 (1980)}, isbn = {0208-6573}, pages = {9 -- 13}, year = {1980}, language = {en} } @article{TurekKettererClassenetal.2007, author = {Turek, Monika and Ketterer, Lothar and Claßen, Melanie and Berndt, Heinz and Elbers, Gereon and Kr{\"u}ger, Peter and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Development and Electrochemical Investigations of an EIS-(Electrolyte-Insulator-Semiconductor) based Biosensor for Cyanide Detection}, series = {Sensors}, volume = {7}, journal = {Sensors}, number = {8}, isbn = {1424-8220}, pages = {1415 -- 1426}, year = {2007}, language = {en} } @article{WagnerMolinaYoshinobuetal.2007, author = {Wagner, Torsten and Molina, Roberto and Yoshinobu, Tatsuo and Kloock, Joachim P. and Biselli, Manfred and Canzoneri, Michele and Schnitzler, Thomas and Sch{\"o}ning, Michael Josef}, title = {Handheld multi-channel LAPS device as a transducer platform for possible biological and chemical multi-sensor applications}, series = {Electrochimica Acta. 53 (2007), H. 2}, journal = {Electrochimica Acta. 53 (2007), H. 2}, isbn = {0013-4686}, pages = {305 -- 311}, year = {2007}, language = {en} } @article{PawelkeSchmittMeissen1990, author = {Pawelke, Siegfried and Schmitt, W. and Meissen, Th.}, title = {Aachen 3D finger. 3D digitizer for application in dentistry / Schmitt, W. ; Pawelke, S. ; Meissen, Th.}, series = {Biomedizinische Technik. 35 (1990), H. 4}, journal = {Biomedizinische Technik. 35 (1990), H. 4}, isbn = {0013-5585}, pages = {69 -- 71}, year = {1990}, language = {en} } @article{Pawelke2000, author = {Pawelke, Siegfried}, title = {Note on Jackson and Bernstein type approximation theorems in the case of approximation by algebraic polynomial in the spaces L and C}, series = {Studia Scientiarum Mathematicarum Hungarica. 36 (2000), H. 3-4}, journal = {Studia Scientiarum Mathematicarum Hungarica. 36 (2000), H. 3-4}, isbn = {0081-6906}, pages = {353 -- 358}, year = {2000}, language = {en} } @article{SanderErwinHuber1999, author = {Sander, Volker and Erwin, Dietmar and Huber, Valentina}, title = {High-performance computer management based on Java}, series = {Future Generation Computer Systems. 15 (1999), H. 3}, journal = {Future Generation Computer Systems. 15 (1999), H. 3}, isbn = {0167-739X}, pages = {425 -- 432}, year = {1999}, language = {en} }