@article{MoseleyHalamekKrameretal.2014, author = {Moseley, Fiona and Halamek, Jan and Kramer, Friederike and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Katz, Evgeny}, title = {An enzyme-based reversible CNOT logic gate realized in a flow system}, series = {Analyst}, volume = {139}, journal = {Analyst}, number = {8}, publisher = {Royal Society of Chemistry}, address = {Cambridge}, issn = {1364-5528 (E-Journal) ; 0003-2654 (Print)}, doi = {10.1039/C4AN00133H}, pages = {1839 -- 1842}, year = {2014}, abstract = {An enzyme system organized in a flow device was used to mimic a reversible Controlled NOT (CNOT) gate with two input and two output signals. Reversible conversion of NAD⁺ and NADH cofactors was used to perform a XOR logic operation, while biocatalytic hydrolysis of p-nitrophenyl phosphate resulted in an Identity operation working in parallel. The first biomolecular realization of a CNOT gate is promising for integration into complex biomolecular networks and future biosensor/biomedical applications.}, language = {en} } @article{HonarvarfardGamellaPoghossianetal.2017, author = {Honarvarfard, Elham and Gamella, Maria and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Katz, Evgeny}, title = {An enzyme-based reversible Controlled NOT (CNOT) logic gate operating on a semiconductor transducer}, series = {Applied Materials Today}, volume = {9}, journal = {Applied Materials Today}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2352-9407}, doi = {10.1016/j.apmt.2017.08.003}, pages = {266 -- 270}, year = {2017}, abstract = {An enzyme-based biocatalytic system mimicking operation of a logically reversible Controlled NOT (CNOT) gate has been interfaced with semiconductor electronic transducers. Electrolyte-insulator-semiconductor (EIS) structures have been used to transduce chemical changes produced by the enzyme system to an electronically readable capacitive output signal using field-effect features of the EIS device. Two enzymes, urease and esterase, were immobilized on the insulating interface of EIS structure producing local pH changes performing XOR logic operation controlled by various combinations of the input signals represented by urea and ethyl butyrate. Another EIS transducer was functionalized with esterase only, thus performing Identity (ID) logic operation for the ethyl butyrate input. Both semiconductor devices assembled in parallel operated as a logically reversible CNOT gate. The present system, despite its simplicity, demonstrated for the first time logically reversible function of the enzyme system transduced electronically with the semiconductor devices. The biomolecular realization of a CNOT gate interfaced with semiconductors is promising for integration into complex biomolecular networks and future biosensor/biomedical applications.}, language = {en} } @article{SchiffelsPinkenburgScheldenetal.2013, author = {Schiffels, Johannes and Pinkenburg, Olaf and Schelden, Maximilian and Aboulnaga, El-Hussiny A. A. and Baumann, Marcus and Selmer, Thorsten}, title = {An innovative cloning platform enables large-scale production and maturation of an oxygen-tolerant [NiFe]-hydrogenase from cupriavidus necator in Escherichia coli}, series = {PLOS one. 2013}, journal = {PLOS one. 2013}, publisher = {Public Library of Science}, address = {San Francisco, California}, issn = {1932-6203}, doi = {10.1371/journal.pone.0068812}, year = {2013}, language = {en} } @article{SchuetzSchoeningSchrothetal.2000, author = {Sch{\"u}tz, S. and Sch{\"o}ning, Michael Josef and Schroth, P. and Weißbecker, B. and Kordos, P. and L{\"u}th, H. and Hummel, Hans E.}, title = {An insectbased BioFET as a bioelectronic nose}, series = {Sensors and Actuators B. 65 (2000), H. 1-3}, journal = {Sensors and Actuators B. 65 (2000), H. 1-3}, isbn = {0925-4005}, pages = {291 -- 295}, year = {2000}, language = {en} } @article{PoghossianSchoeningSchrothetal.2001, author = {Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Schroth, P. and Simonis, A. and L{\"u}th, H.}, title = {An ISFET-based penicillin sensor with high sensitivity, low detection limit and long lifetime}, series = {Sensors and Actuators B. 76 (2001), H. 1-3}, journal = {Sensors and Actuators B. 76 (2001), H. 1-3}, isbn = {0925-4005}, pages = {519 -- 526}, year = {2001}, language = {en} } @article{MuribTranCeunincketal.2012, author = {Murib, Mohammed S. and Tran, Anh Quang and Ceuninck, Ward de and Sch{\"o}ning, Michael Josef and Nesladek, Milos and Serpeng{\"u}zel, Ali and Wagner, Patrick}, title = {Analysis of an optical biosensor based on elastic light scattering from diamond-, glass-, and sapphire microspheres}, series = {Physica Status Solidi A}, volume = {209}, journal = {Physica Status Solidi A}, number = {9}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100795}, pages = {1804 -- 1810}, year = {2012}, abstract = {Deoxyribonucleic acid (DNA) and protein recognition are now standard tools in biology. In addition, the special optical properties of microsphere resonators expressed by the high quality factor (Q-factor) of whispering gallery modes (WGMs) or morphology dependent resonances (MDRs) have attracted the attention of the biophotonic community. Microsphere-based biosensors are considered as powerful candidates to achieve label-free recognition of single molecules due to the high sensitivity of their WGMs. When the microsphere surface is modified with biomolecules, the effective refractive index and the effective size of the microsphere change resulting in a resonant wavelength shift. The transverse electric (TE) and the transverse magnetic (TM) elastic light scattering intensity of electromagnetic waves at 600 and 1400 nm are numerically calculated for DNA and unspecific binding of proteins to the microsphere surface. The effect of changing the optical properties was studied for diamond (refractive index 2.34), glass (refractive index 1.50), and sapphire (refractive index 1.75) microspheres with a 50 µm radius. The mode spacing, the linewidth of WGMs, and the shift of resonant wavelength due to the change in radius and refractive index, were analyzed by numerical simulations. Preliminary results of unspecific binding of biomolecules are presented. The calculated shift in WGMs can be used for biomolecules detection.}, language = {en} } @article{HeidenTurekSchoening2011, author = {Heiden, W. and Turek, M. and Sch{\"o}ning, Michael Josef}, title = {Analysis of chemical sensor data}, series = {Proceedings of the 4th Russian-German Workshop "Innovation Information Technologies: Theory and practice" : Ufa, Russia, April 8-13, 2011 / eds. Yupsova, Nafisa ...}, journal = {Proceedings of the 4th Russian-German Workshop "Innovation Information Technologies: Theory and practice" : Ufa, Russia, April 8-13, 2011 / eds. Yupsova, Nafisa ...}, publisher = {State Aviation Technical Univ.}, address = {Ufa}, isbn = {978-5-4221-0159-7}, pages = {76 -- 81}, year = {2011}, language = {en} } @article{MourzinaErmelenkoYoshinobuetal.2003, author = {Mourzina, Y. G. and Ermelenko, Y. E. and Yoshinobu, T. and Vlasov, Y. and Iwasaki, H. and Sch{\"o}ning, Michael Josef}, title = {Anionselective light-addressable potentiometric sensors (LAPS) for the determination of nitrate and suphate ions}, series = {Sensors and Actuators B. 91 (2003), H. 1-3}, journal = {Sensors and Actuators B. 91 (2003), H. 1-3}, isbn = {0925-4005}, pages = {32 -- 38}, year = {2003}, language = {en} } @article{PoghossianSchultzeSchoening2003, author = {Poghossian, Arshak and Schultze, J. W. and Sch{\"o}ning, Michael Josef}, title = {Application of a (bio-)chemical sensor (ISFET) for the detection of physical parameters in liquids}, series = {Electrochimica Acta. 48 (2003), H. 20-22}, journal = {Electrochimica Acta. 48 (2003), H. 20-22}, pages = {3289 -- 3297}, year = {2003}, language = {en} } @article{PilasYaziciSelmeretal.2018, author = {Pilas, Johanna and Yazici, Y. and Selmer, Thorsten and Keusgen, M. and Sch{\"o}ning, Michael Josef}, title = {Application of a portable multi-analyte biosensor for organic acid determination in silage}, series = {Sensors}, volume = {18}, journal = {Sensors}, number = {5}, publisher = {MDPI}, address = {Basel}, issn = {1424-8220}, doi = {10.3390/s18051470}, pages = {12 Seiten}, year = {2018}, abstract = {Multi-analyte biosensors may offer the opportunity to perform cost-effective and rapid analysis with reduced sample volume, as compared to electrochemical biosensing of each analyte individually. This work describes the development of an enzyme-based biosensor system for multi-parametric determination of four different organic acids. The biosensor array comprises five working electrodes for simultaneous sensing of ethanol, formate, d-lactate, and l-lactate, and an integrated counter electrode. Storage stability of the biosensor was evaluated under different conditions (stored at +4 °C in buffer solution and dry at -21 °C, +4 °C, and room temperature) over a period of 140 days. After repeated and regular application, the individual sensing electrodes exhibited the best stability when stored at -21 °C. Furthermore, measurements in silage samples (maize and sugarcane silage) were conducted with the portable biosensor system. Comparison with a conventional photometric technique demonstrated successful employment for rapid monitoring of complex media.}, language = {en} } @article{MiyamatoSakakitaWagneretal.2015, author = {Miyamato, Ko-ichiro and Sakakita, Sakura and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Application of chemical imaging sensor to in-situ pH imaging in the vicinity of a corroding metal surface}, series = {Electrochimica Acta}, volume = {183}, journal = {Electrochimica Acta}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0013-4686}, doi = {10.1016/j.electacta.2015.07.184}, pages = {137 -- 142}, year = {2015}, abstract = {The chemical imaging sensor was applied to in-situ pH imaging of the solution in the vicinity of a corroding surface of stainless steel under potentiostatic polarization. A test piece of polished stainless steel was placed on the sensing surface leaving a narrow gap filled with artificial seawater and the stainless steel was corroded under polarization. The pH images obtained during polarization showed correspondence between the region of lower pH and the site of corrosion. It was also found that the pH value in the gap became as low as 2 by polarization, which triggered corrosion.}, language = {en} } @article{PoghossianBaadeEmonsetal.2001, author = {Poghossian, Arshak and Baade, A. and Emons, H. and Sch{\"o}ning, Michael Josef}, title = {Application of ISFET for pH measurements in rain droplets}, series = {Sensors and Actuators B. 76 (2001), H. 1-3}, journal = {Sensors and Actuators B. 76 (2001), H. 1-3}, isbn = {0925-4005}, pages = {634 -- 638}, year = {2001}, language = {en} } @article{YoshinobuMoritzFingeretal.2006, author = {Yoshinobu, Tatsuo and Moritz, Werner and Finger, Friedhelm and Sch{\"o}ning, Michael Josef}, title = {Application of thin-film amorphous silicon to chemical imaging}, series = {Nanostructured materials and hybrid composites for gas sensors and biomedical applications : symposium held April 18-20, 2006, San Francisco , California, U.S.A.}, journal = {Nanostructured materials and hybrid composites for gas sensors and biomedical applications : symposium held April 18-20, 2006, San Francisco , California, U.S.A.}, number = {Paper 0910-A-20-01}, editor = {Comini, Elisabetta}, isbn = {9781558998711}, pages = {1 -- 10}, year = {2006}, language = {en} } @article{YoshinobuYasuhitoIwasakietal.2004, author = {Yoshinobu, T. and Yasuhito, U. and Iwasaki, H. and N{\"a}ther, Niko and Sch{\"o}ning, Michael Josef and Koudelka-Hep, M.}, title = {Applications of the light-addressable potentiometric sensor to microfluidic devices}, series = {Digest of technical papers : September 12 - 15, 2004, Rome, Italy, Pontificia Universitas Sancto Thoma Aquinate in Urbe / [conference chairperson: C. Di Natale].}, journal = {Digest of technical papers : September 12 - 15, 2004, Rome, Italy, Pontificia Universitas Sancto Thoma Aquinate in Urbe / [conference chairperson: C. Di Natale].}, address = {Roma}, isbn = {88-7621-282-5}, pages = {434 -- 437}, year = {2004}, language = {en} } @article{FigueroaMirandaFengShiuetal.2018, author = {Figueroa-Miranda, Gabriela and Feng, Lingyan and Shiu, Simon Chi-Chin and Dirkzwager, Roderick Marshall and Cheung, Yee-Wai and Tanner, Julian Alexander and Sch{\"o}ning, Michael Josef and Offenh{\"a}usser, Andreas and Mayer, Dirk}, title = {Aptamer-based electrochemical biosensor for highly sensitive and selective malaria detection with adjustable dynamic response range and reusability}, series = {Sensor and Actuators B: Chemical}, volume = {255}, journal = {Sensor and Actuators B: Chemical}, number = {P1}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2017.07.117}, pages = {235 -- 243}, year = {2018}, abstract = {Malaria infection remains a significant risk for much of the population of tropical and subtropical areas, particularly in developing countries. Therefore, it is of high importance to develop sensitive, accurate and inexpensive malaria diagnosis tests. Here, we present a novel aptamer-based electrochemical biosensor (aptasensor) for malaria detection by impedance spectroscopy, through the specific recognition between a highly discriminatory DNA aptamer and its target Plasmodium falciparum lactate dehydrogenase (PfLDH). Interestingly, due to the isoelectric point (pI) of PfLDH, the aptasensor response showed an adjustable detection range based on the different protein net-charge at variable pH environments. The specific aptamer recognition allows sensitive protein detection with an expanded detection range and a low detection limit, as well as a high specificity for PfLDH compared to analogous proteins. The specific feasibility of the aptasensor is further demonstrated by detection of the target PfLDH in human serum. Furthermore, the aptasensor can be easily regenerated and thus applied for multiple usages. The robustness, sensitivity, and reusability of the presented aptasensor make it a promising candidate for point-of-care diagnostic systems.}, language = {en} } @article{SchoeningTurekHeidenetal.2009, author = {Sch{\"o}ning, Michael Josef and Turek, M. and Heiden, W. and Riesen, A. and Chhabda, T. A. and Schubert, J. and Kr{\"u}ger, P. and Keusgen, M.}, title = {Artificial intelligence/fuzzy logic method for analysis of combined signals from heavy metal chemical sensors}, series = {Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI}, journal = {Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI}, publisher = {Elsevier}, address = {New York}, isbn = {0013-4686}, pages = {6082 -- 6088}, year = {2009}, language = {en} } @article{VahidpourGuthmanArreolaetal.2022, author = {Vahidpour, Farnoosh and Guthman, Eric and Arreola, Julia and Alghazali, Yousef H. M. and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Assessment of Various Process Parameters for Optimized Sterilization Conditions Using a Multi-Sensing Platform}, series = {Foods}, volume = {11}, journal = {Foods}, number = {5}, publisher = {MDPI}, address = {Basel}, issn = {2304-8158}, doi = {10.3390/foods11050660}, pages = {Artikel 660}, year = {2022}, abstract = {In this study, an online multi-sensing platform was engineered to simultaneously evaluate various process parameters of food package sterilization using gaseous hydrogen peroxide (H₂O₂). The platform enabled the validation of critical aseptic parameters. In parallel, one series of microbiological count reduction tests was performed using highly resistant spores of B. atrophaeus DSM 675 to act as the reference method for sterility validation. By means of the multi-sensing platform together with microbiological tests, we examined sterilization process parameters to define the most effective conditions with regards to the highest spore kill rate necessary for aseptic packaging. As these parameters are mutually associated, a correlation between different factors was elaborated. The resulting correlation indicated the need for specific conditions regarding the applied H₂O₂ gas temperature, the gas flow and concentration, the relative humidity and the exposure time. Finally, the novel multi-sensing platform together with the mobile electronic readout setup allowed for the online and on-site monitoring of the sterilization process, selecting the best conditions for sterility and, at the same time, reducing the use of the time-consuming and costly microbiological tests that are currently used in the food package industry.}, language = {en} } @article{SiqueiraBaeckerPoghossianetal.2010, author = {Siqueira, Jos{\´e} R. Jr. and B{\"a}cker, Matthias and Poghossian, Arshak and Zucolotto, Valtencir and Oliveira, Osvaldo N. Jr. and Sch{\"o}ning, Michael Josef}, title = {Associating biosensing properties with the morphological structure of multilayers containing carbon nanotubes on field-effect devices}, series = {Physica status solidi (a). 207 (2010), H. 4}, journal = {Physica status solidi (a). 207 (2010), H. 4}, isbn = {1862-6300}, pages = {781 -- 786}, year = {2010}, language = {en} } @article{BuniatyanHuckPoghossianetal.2013, author = {Buniatyan, V. and Huck, Christina and Poghossian, Arshak and Aroutiounian, V. M. and Sch{\"o}ning, Michael Josef}, title = {BaxSr1-x TiO3/pc-Si heterojunction}, series = {Armenian journal of physics}, volume = {6}, journal = {Armenian journal of physics}, number = {4}, publisher = {National Academy of Sciences of Armenia}, address = {Yerevan}, issn = {1829-1171}, pages = {177 -- 187}, year = {2013}, language = {en} } @article{BuniatyanHuckPoghossianetal.2013, author = {Buniatyan, V. and Huck, Christina and Poghossian, Arshak and Aroutiounian, V. M. and Sch{\"o}ning, Michael Josef}, title = {BaxSr1-x TiO3/pc-Si heterojunction capacitance}, series = {Armenian journal of physics}, volume = {6}, journal = {Armenian journal of physics}, number = {4}, publisher = {National Academy of Sciences of Armenia}, address = {Yerevan}, issn = {1829-1171}, pages = {188 -- 197}, year = {2013}, language = {en} }