@article{AkimbekovMansurovJandosovetal.2013, author = {Akimbekov, Nuraly S. and Mansurov, Zulkhair and Jandosov, J. and Digel, Ilya and Gossmann, Matthias and Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l and Zhubanova, Azhar A.}, title = {Wound healing activity of carbonized rice husk}, publisher = {Trans Tech Publications, Switzerland}, address = {B{\"a}ch}, year = {2013}, abstract = {The carbonized rice husk (CRH) was evaluated for its wound healing activity in rats using excision models. In this study, the influences of CRH on wound healing in rat skin in vivo and cellular behavior of human dermal fibroblasts in vitro were investigated. The obtained results showed that the CRH treatment promoted wound epithelization in rats and exhibited moderate inhibition of cell proliferation in vitro. CRH with lanolin oil treated wounds were found to epithelize faster as compared to controls.}, subject = {Wundheilung}, language = {en} } @inproceedings{FunkeBoernerHendricketal.2013, author = {Funke, Harald and B{\"o}rner, Sebastian and Hendrick, P. and Recker, E. and Elsing, R.}, title = {Development and integration of a scalable low NOx combustion chamber for a hydrogen fuelled aero gas turbine}, series = {Progress in Propulsion Physics. - Vol. 4}, booktitle = {Progress in Propulsion Physics. - Vol. 4}, editor = {DeLuca, Luigi T.}, publisher = {EDP Sciences}, address = {[Les Ulis]}, isbn = {978-2-7598-0876-2}, doi = {10.1051/eucass/201304357}, pages = {357 -- 372}, year = {2013}, language = {en} } @article{PhamStaat2013, author = {Pham, Phu Tinh and Staat, Manfred}, title = {An Upper Bound Algorithm for Limit and Shakedown Analysis of Bounded Linearly Kinematic Hardening Structures}, series = {Limit State of Materials and Structures : Direct Methods 2. Saxc{\´e}, G{\´e}ry de (Hrsg.)}, journal = {Limit State of Materials and Structures : Direct Methods 2. Saxc{\´e}, G{\´e}ry de (Hrsg.)}, publisher = {Springer}, address = {Dordrecht}, isbn = {978-94-007-5424-9}, pages = {71 -- 87}, year = {2013}, language = {en} } @article{TranStaat2013, author = {Tran, Thanh Ngoc and Staat, Manfred}, title = {An Edge-Based Smoothed Finite Element Method for Primal-Dual Shakedown Analysis of Structures Under Uncertainties}, series = {Limit State of Materials and Structures : Direct Methods 2. Saxc{\´e}, G{\´e}ry de (Hrsg.)}, journal = {Limit State of Materials and Structures : Direct Methods 2. Saxc{\´e}, G{\´e}ry de (Hrsg.)}, publisher = {Springer}, address = {Dordrecht}, isbn = {978-94-007-5424-9}, pages = {89 -- 102}, year = {2013}, language = {en} } @article{BohrnStuetzFleischeretal.2013, author = {Bohrn, Ulrich and St{\"u}tz, Evamaria and Fleischer, Maximilian and Sch{\"o}ning, Michael Josef and Wagner, Patrick}, title = {Using a cell-based gas biosensor for investigation of adverse effects of acetone vapors in vitro}, series = {Biosensors and Bioelectronics. 40 (2013), H. 1}, journal = {Biosensors and Bioelectronics. 40 (2013), H. 1}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0956-5663}, pages = {393 -- 400}, year = {2013}, language = {en} } @article{HennemannKohlReisertetal.2013, author = {Hennemann, J{\"o}rg and Kohl, Claus-Dieter and Reisert, Steffen and Kirchner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Copper oxide nanofibres for detection of hydrogen peroxide vapour at high concentrations}, series = {physica status solidi (a)}, volume = {210}, journal = {physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201200775}, pages = {859 -- 863}, year = {2013}, abstract = {We present a sensor concept based on copper(II)oxide (CuO) nanofibres for the detection of hydrogen peroxide (H2O2) vapour in the percent per volume (\% v/v) range. The fibres were produced by using the electrospinning technique. To avoid water condensation in the pores, the fibres were initially modified by an exposure to H2S to get an enclosed surface. By a thermal treatment at 350 °C the fibres were oxidised back to CuO. Thereby, the visible pores disappear which was verified by SEM analysis. The fibres show a decrease of resistance with increasing H2O2 concentration which is due to the fact that hydrogen peroxide is an oxidising gas and CuO a p-type semiconductor. The sensor shows a change of resistance within the minute range to the exposure until the maximum concentration of 6.9\% v/v H2O2. At operating temperatures below 450 °C the corresponding sensor response to a concentration of 4.1\% v/v increases. The sensor shows a good reproducibility of the signal at different measurements. CuO seems to be a suitable candidate for the detection of H2O2 vapour at high concentrations. Resistance behaviour of the sensor under exposure to H2O2 vapours between 2.3 and 6.9\% v/v at an operating temperature of 450 °C.}, language = {en} } @article{ReisertSchneiderGeissleretal.2013, author = {Reisert, Steffen and Schneider, Benno and Geissler, Hanno and Gompel, Matthias van and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Multi-sensor chip for the investigation of different types of metal oxides for the detection of H2O2 in the ppm range}, series = {physica status solidi (a)}, volume = {210}, journal = {physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, pages = {898 -- 904}, year = {2013}, abstract = {In this work, a multi-sensor chip for the investigation of the sensing properties of different types of metal oxides towards hydrogen peroxide in the ppm range is presented. The fabrication process and physical characterization of the multi-sensor chip are described. Pure SnO2 and WO3 as well as Pd- and Pt-doped SnO2 films are characterized in terms of their sensitivity to H2O2. The sensing films have been prepared by drop-coating of water-dispensed nano-powders. A physical characterization, including scanning electron microscopy and X-ray diffraction analysis of the deposited metal-oxide films, was done. From the measurements in hydrogen peroxide atmosphere, it could be shown, that all of the tested metal oxide films are suitable for the detection of H2O2 in the ppm range. The highest sensitivity and reproducibility was achieved using Pt-doped SnO2. Calibration plot of a SnO2, WO3, Pt-, and Pd-doped SnO2 gas sensor for H2O2 concentrations in the ppm range.}, language = {en} } @article{KotliarHanssenEberhardtetal.2013, author = {Kotliar, Konstantin and Hanssen, Henner and Eberhardt, Karla and Vilser, Walthard and Schmaderer, Christoph and Halle, Martin and Heemann, Uwe and Baumann, M.}, title = {Retinal pulse wave velocity in young male normotensive and mildly hypertensive subjects}, series = {Microcirculation}, journal = {Microcirculation}, publisher = {Wiley}, address = {Malden}, issn = {1549-8719}, year = {2013}, language = {en} } @article{FeuchtSchoenbachLanzletal.2013, author = {Feucht, Nikolaus and Sch{\"o}nbach, Etienne Michael and Lanzl, Ines and Kotliar, Konstantin and Lohmann, Chris Patrick and Maier, Mathias}, title = {Changes in the foveal microstructure after intravitreal bevacizumab application in patients with retinal vascular disease}, series = {Clinical Ophthalmology}, volume = {7}, journal = {Clinical Ophthalmology}, publisher = {Dove Medical Press}, address = {Auckland, New Zealand}, issn = {1177-5483}, pages = {173 -- 178}, year = {2013}, language = {en} } @article{GebhardtFateri2013, author = {Gebhardt, Andreas and Fateri, Miranda}, title = {3D printing and its applications}, series = {RTejournal - Forum f{\"u}r Rapid Technologie}, volume = {10}, journal = {RTejournal - Forum f{\"u}r Rapid Technologie}, number = {1}, publisher = {Fachhochschule Aachen}, address = {Aachen}, issn = {1614-0923}, url = {http://nbn-resolving.de/urn:nbn:de:0009-2-35626}, year = {2013}, abstract = {Eine zunehmende Anzahl von Artikeln in Publikumszeitschriften und Journalen r{\"u}ckt die direkte Herstellung von Bauteilen und Figuren immer mehr in das Bewusstsein einer breiten {\"O}ffentlichkeit. Leider ergibt sich nur selten ein einigermaßen vollst{\"a}ndiges Bild davon, wie und in welchen Lebensbereichen diese Techniken unseren Alltag ver{\"a}ndern werden. Das liegt auch daran, dass die meisten Artikel sehr technisch gepr{\"a}gt sind und sich nur punktuell auf Beispiele st{\"u}tzen. Dieser Beitrag geht von den Bed{\"u}rfnissen der Menschen aus, wie sie z.B. in der Maslow'schen Bed{\"u}rfnispyramide strukturiert dargestellt sind und unterstreicht dadurch, dass 3D Printing (oder Additive Manufacturing resp. Rapid Prototyping) bereits alle Lebensbereiche erfasst hat und im Begriff ist, viele davon zu revolutionieren.}, language = {en} } @article{KirchnerOberlaenderSusoetal.2013, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Suso, Henri-Pierre and Rysstad, Gunnar and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes}, series = {Physica status solidi (a)}, volume = {210}, journal = {Physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201200920}, pages = {877 -- 883}, year = {2013}, abstract = {A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests.}, language = {en} } @inproceedings{GerhardsSanderBelloum2013, author = {Gerhards, Michael and Sander, Volker and Belloum, Adam}, title = {Seamlessly enabling the use of cloud resources in workflows}, series = {Cloud Computing 2013 : The Fourth International Conference on Cloud Computing, GRIDs, and Virtualization : May 27 - June 1, 2013 - Valencia, Spain}, booktitle = {Cloud Computing 2013 : The Fourth International Conference on Cloud Computing, GRIDs, and Virtualization : May 27 - June 1, 2013 - Valencia, Spain}, publisher = {Curren}, address = {Red Hook, NY}, organization = {International Conference on Cloud Computing, GRIDs, and Virtualization <4, 2013, Valencia>}, isbn = {978-1-61208-271-4}, pages = {108 -- 114}, year = {2013}, language = {en} } @inproceedings{NiemuellerLakemeyerFerrein2013, author = {Niem{\"u}ller, Tim and Lakemeyer, Gerhard and Ferrein, Alexander}, title = {Aspects of integrating diverse software into robotic systems extended abstract}, series = {ICRA 2013 - 8th Workshop on Software Development and Integration in Robotics (SDIR), Karlsruhe, Germany}, booktitle = {ICRA 2013 - 8th Workshop on Software Development and Integration in Robotics (SDIR), Karlsruhe, Germany}, pages = {1 -- 2}, year = {2013}, language = {en} } @article{MiyamotoIchimuraWagneretal.2013, author = {Miyamoto, Ko-ichiro and Ichimura, Hiroki and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel}, series = {Sensors and actuators. B: Chemical}, volume = {189}, journal = {Sensors and actuators. B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077 (E-Journal); 0925-4005 (Print)}, doi = {10.1016/j.snb.2013.04.057}, pages = {240 -- 245}, year = {2013}, abstract = {The chemical imaging sensor is a device to visualize the spatial distribution of chemical species based on the principle of LAPS (light-addressable potentiometric sensor), which is a field-effect chemical sensor based on semiconductor. In this study, the chemical imaging sensor has been applied to investigate the ion profile of laminar flows in a microfluidic channel. The chemical images (pH maps) were collected in a Y-shaped microfluidic channel while injecting HCl and NaCl solutions into two branches. From the chemical images, it was clearly observed that the injected solutions formed laminar flows in the channel. In addition, ion diffusion across the laminar flows was observed, and the diffusion coefficient could be derived by fitting the pH profiles to the Fick's equation.}, language = {en} } @inproceedings{SchuetzBreuerHoefkenetal.2013, author = {Sch{\"u}tz, P. and Breuer, M. and H{\"o}fken, Hans-Wilhelm and Schuba, Marko}, title = {Malware proof on mobile phone exhibits based on GSM/GPRS traces}, series = {The Second International Conference on Cyber Security, Cyber Peacefare and Digital Forensic (CyberSec 2013) : 04.03. - 06.03.2013, Kuala Lumpur, Malaysia}, booktitle = {The Second International Conference on Cyber Security, Cyber Peacefare and Digital Forensic (CyberSec 2013) : 04.03. - 06.03.2013, Kuala Lumpur, Malaysia}, publisher = {The Society of Digital Information and Wireless Communication}, isbn = {978-0-9853483-7-3}, pages = {89 -- 96}, year = {2013}, language = {en} } @article{BohrnMuchaWerneretal.2013, author = {Bohrn, Ulrich and Mucha, Andreas and Werner, Frederik and Trattner, Barbara and B{\"a}cker, Matthias and Krumbe, Christoph and Schienle, Meinrad and St{\"u}tz, Evamaria and Schmitt-Landsiedel, Doris and Fleischer, Maximilian and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {A critical comparison of cell-based sensor systems for the detection of Cr (VI) in aquatic environment}, series = {Sensors and actuators. B: Chemical}, volume = {Vol. 182}, journal = {Sensors and actuators. B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077 (E-Journal); 0925-4005 (Print)}, pages = {58 -- 65}, year = {2013}, language = {en} } @article{KramerHalamkovaPoghossianetal.2013, author = {Kramer, Friederike and Halamkova, Lenka and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Katz, Evgeny and Halamek, Jan}, title = {Biocatalytic analysis of biomarkers for forensic identification of ethnicity between Caucasian and African American}, series = {The analyst. August 2013}, volume = {Vol. 138}, journal = {The analyst. August 2013}, publisher = {Royal Society of Chemistry}, address = {Cambridge}, issn = {1364-5528 (E-Journal); 0003-2654 (Print)}, pages = {6251 -- 6257}, year = {2013}, language = {en} } @article{Laack2013, author = {Laack, Walter van}, title = {The genetic code should be seen as a positioning code}, series = {British journal of arts and social sciences. Vol. 14 (2013), No. 1}, journal = {British journal of arts and social sciences. Vol. 14 (2013), No. 1}, issn = {2046-9578}, pages = {93 -- 97}, year = {2013}, language = {en} } @inproceedings{FredebeulKreinSteingroever2013, author = {Fredebeul-Krein, Markus and Steingr{\"o}ver, Markus}, title = {Enhancing broadband development and internet usages for improving networks and services in APEC member economies: Bridging the digital divide}, series = {The 19th ITS Biennial Conference 2012 "Moving Forward with Future Technologies: Opening a Platform for All" 18 - 21 November 2012, Thailand}, booktitle = {The 19th ITS Biennial Conference 2012 "Moving Forward with Future Technologies: Opening a Platform for All" 18 - 21 November 2012, Thailand}, publisher = {ITS}, address = {Bangkok}, pages = {13 S.}, year = {2013}, language = {en} } @article{BaeckerRakowskiPoghossianetal.2013, author = {B{\"a}cker, Matthias and Rakowski, D. and Poghossian, Arshak and Biselli, Manfred and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Chip-based amperometric enzyme sensor system for monitoring of bioprocesses by flow-injection analysis}, series = {Journal of Biotechnology}, volume = {163}, journal = {Journal of Biotechnology}, number = {4}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0168-1656}, doi = {10.1016/j.jbiotec.2012.03.014}, pages = {371 -- 376}, year = {2013}, abstract = {A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses.}, language = {en} }