@inproceedings{StreunAlKaddoumParletal.2012, author = {Streun, M. and Al-Kaddoum, R. and Parl, C. and Pietrzyk, U. and Ziemons, Karl and Waasen, S. van}, title = {Simulation studies of optical photons in monolithic block scintillators}, series = {2011 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, booktitle = {2011 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)}, publisher = {IEEE}, address = {New York}, isbn = {978-1-4673-0120-6 (electronic ISBN)}, doi = {10.1109/NSSMIC.2011.6154621}, pages = {1380 -- 1382}, year = {2012}, abstract = {The interest in PET detectors with monolithic block scintillators is growing. In order to obtain high spatial resolutions dedicated positioning algorithms are required. But even an ideal algorithm can only deliver information which is provided by the detector. In this simulation study we investigated the light distribution on one surface of cuboid LSO scintillators of different size. Scintillators with a large aspect ratio (small footprint and large height) showed significant position information only for a minimum interaction depth of the gamma particle. The results allow a quantitative estimate for a useful aspect ratio.}, language = {en} } @article{GebhardtFateri2013, author = {Gebhardt, Andreas and Fateri, Miranda}, title = {3D printing and its applications}, series = {RTejournal - Forum f{\"u}r Rapid Technologie}, volume = {10}, journal = {RTejournal - Forum f{\"u}r Rapid Technologie}, number = {1}, publisher = {Fachhochschule Aachen}, address = {Aachen}, issn = {1614-0923}, url = {http://nbn-resolving.de/urn:nbn:de:0009-2-35626}, year = {2013}, abstract = {Eine zunehmende Anzahl von Artikeln in Publikumszeitschriften und Journalen r{\"u}ckt die direkte Herstellung von Bauteilen und Figuren immer mehr in das Bewusstsein einer breiten {\"O}ffentlichkeit. Leider ergibt sich nur selten ein einigermaßen vollst{\"a}ndiges Bild davon, wie und in welchen Lebensbereichen diese Techniken unseren Alltag ver{\"a}ndern werden. Das liegt auch daran, dass die meisten Artikel sehr technisch gepr{\"a}gt sind und sich nur punktuell auf Beispiele st{\"u}tzen. Dieser Beitrag geht von den Bed{\"u}rfnissen der Menschen aus, wie sie z.B. in der Maslow'schen Bed{\"u}rfnispyramide strukturiert dargestellt sind und unterstreicht dadurch, dass 3D Printing (oder Additive Manufacturing resp. Rapid Prototyping) bereits alle Lebensbereiche erfasst hat und im Begriff ist, viele davon zu revolutionieren.}, language = {en} } @article{KirchnerOberlaenderSusoetal.2013, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Suso, Henri-Pierre and Rysstad, Gunnar and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes}, series = {Physica status solidi (a)}, volume = {210}, journal = {Physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201200920}, pages = {877 -- 883}, year = {2013}, abstract = {A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests.}, language = {en} } @article{KhodaverdiChatziioannouWeberetal.2005, author = {Khodaverdi, M. and Chatziioannou, A. F. and Weber, S. and Ziemons, Karl and Halling, H. and Pietrzyk, U.}, title = {Investigation of different MicroCT scanner configurations by GEANT4 simulations}, series = {IEEE Transactions on Nuclear Science}, volume = {52}, journal = {IEEE Transactions on Nuclear Science}, number = {1}, isbn = {0018-9499}, pages = {188 -- 192}, year = {2005}, abstract = {This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.}, language = {en} } @article{StreunBrandenburgLarueetal.2006, author = {Streun, M. and Brandenburg, G. and Larue, H. and Parl, C. and Ziemons, Karl}, title = {The data acquisition system of ClearPET neuro - a small animal PET scanner}, series = {IEEE Transactions on Nuclear Science}, volume = {53}, journal = {IEEE Transactions on Nuclear Science}, number = {3}, isbn = {0018-9499}, pages = {700 -- 703}, year = {2006}, abstract = {The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in J{\"u}lich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system.}, language = {en} } @article{KhodaverdiWeberStreunetal.2006, author = {Khodaverdi, M. and Weber, S. and Streun, M. and Parl, C. and Ziemons, Karl}, title = {High resolution imaging with ClearPET™ Neuro - first animal images}, series = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, journal = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, isbn = {1082-3654}, pages = {1641 -- 1644}, year = {2006}, abstract = {The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance.}, language = {en} } @article{StreunBrandenburgKhodaverdietal.2006, author = {Streun, M. and Brandenburg, G. and Khodaverdi, M. and Larue, H. and Parl, C. and Ziemons, Karl}, title = {Timemark correction for the ClearPET™ scanners}, series = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4}, journal = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4}, isbn = {1082-3654}, pages = {2057 -- 2060}, year = {2006}, abstract = {The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented}, language = {en} } @inproceedings{GerhardsSanderBelloum2013, author = {Gerhards, Michael and Sander, Volker and Belloum, Adam}, title = {Seamlessly enabling the use of cloud resources in workflows}, series = {Cloud Computing 2013 : The Fourth International Conference on Cloud Computing, GRIDs, and Virtualization : May 27 - June 1, 2013 - Valencia, Spain}, booktitle = {Cloud Computing 2013 : The Fourth International Conference on Cloud Computing, GRIDs, and Virtualization : May 27 - June 1, 2013 - Valencia, Spain}, publisher = {Curren}, address = {Red Hook, NY}, organization = {International Conference on Cloud Computing, GRIDs, and Virtualization <4, 2013, Valencia>}, isbn = {978-1-61208-271-4}, pages = {108 -- 114}, year = {2013}, language = {en} } @article{JensKaldenhoffKirschnerHermannsetal.2014, author = {Jens, Otto and Kaldenhoff, E. and Kirschner-Hermanns, R. and M{\"u}hl, Thomas and Klinge, Uwe}, title = {Elongation of textile pelvic floor implants under load is related to complete loss of effective porosity, thereby favoring incorporation in scar plates}, series = {Journal of biomedical materials research. Part A}, volume = {102}, journal = {Journal of biomedical materials research. Part A}, number = {4}, publisher = {Wiley}, address = {New York}, issn = {1552-4965}, doi = {10.1002/jbm.a.34767}, pages = {1079 -- 1084}, year = {2014}, abstract = {Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome.}, language = {en} } @inproceedings{SchwarzerVieiraMuelleretal.2003, author = {Schwarzer, Klemens and Vieira, Maria Eugenia and M{\"u}ller, Christoph and Lehmann, Harry and Coutinho, Lecimara}, title = {Modular solar thermal desalination system with flat plate collector}, series = {RIO 3 - World Climate \& Energy Event : proceedings of the international conference held in Rio de Janeiro, Brazil, 1 -5 december 2003 / chief-ed.: Stefan Krauter ...}, booktitle = {RIO 3 - World Climate \& Energy Event : proceedings of the international conference held in Rio de Janeiro, Brazil, 1 -5 december 2003 / chief-ed.: Stefan Krauter ...}, publisher = {Krauter}, address = {Rio de Janeiro}, isbn = {85-902710-2-1}, pages = {281 -- 286}, year = {2003}, language = {en} } @article{MiyamotoIchimuraWagneretal.2013, author = {Miyamoto, Ko-ichiro and Ichimura, Hiroki and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel}, series = {Sensors and actuators. B: Chemical}, volume = {189}, journal = {Sensors and actuators. B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077 (E-Journal); 0925-4005 (Print)}, doi = {10.1016/j.snb.2013.04.057}, pages = {240 -- 245}, year = {2013}, abstract = {The chemical imaging sensor is a device to visualize the spatial distribution of chemical species based on the principle of LAPS (light-addressable potentiometric sensor), which is a field-effect chemical sensor based on semiconductor. In this study, the chemical imaging sensor has been applied to investigate the ion profile of laminar flows in a microfluidic channel. The chemical images (pH maps) were collected in a Y-shaped microfluidic channel while injecting HCl and NaCl solutions into two branches. From the chemical images, it was clearly observed that the injected solutions formed laminar flows in the channel. In addition, ion diffusion across the laminar flows was observed, and the diffusion coefficient could be derived by fitting the pH profiles to the Fick's equation.}, language = {en} } @inproceedings{SchuetzBreuerHoefkenetal.2013, author = {Sch{\"u}tz, P. and Breuer, M. and H{\"o}fken, Hans-Wilhelm and Schuba, Marko}, title = {Malware proof on mobile phone exhibits based on GSM/GPRS traces}, series = {The Second International Conference on Cyber Security, Cyber Peacefare and Digital Forensic (CyberSec 2013) : 04.03. - 06.03.2013, Kuala Lumpur, Malaysia}, booktitle = {The Second International Conference on Cyber Security, Cyber Peacefare and Digital Forensic (CyberSec 2013) : 04.03. - 06.03.2013, Kuala Lumpur, Malaysia}, publisher = {The Society of Digital Information and Wireless Communication}, isbn = {978-0-9853483-7-3}, pages = {89 -- 96}, year = {2013}, language = {en} } @article{BohrnMuchaWerneretal.2013, author = {Bohrn, Ulrich and Mucha, Andreas and Werner, Frederik and Trattner, Barbara and B{\"a}cker, Matthias and Krumbe, Christoph and Schienle, Meinrad and St{\"u}tz, Evamaria and Schmitt-Landsiedel, Doris and Fleischer, Maximilian and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {A critical comparison of cell-based sensor systems for the detection of Cr (VI) in aquatic environment}, series = {Sensors and actuators. B: Chemical}, volume = {Vol. 182}, journal = {Sensors and actuators. B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077 (E-Journal); 0925-4005 (Print)}, pages = {58 -- 65}, year = {2013}, language = {en} } @inproceedings{SpaeteHafnerSchwarzer2000, author = {Sp{\"a}te, Frank and Hafner, B. and Schwarzer, Klemens}, title = {A system for solar process heat for decentralized applications in developing countries}, series = {ISES 1999 Solar World Congress, Jerusalem, Israel, July 4-9, 1999 : conference proceedings / ed. Gershon Grossman. Vol. 3}, booktitle = {ISES 1999 Solar World Congress, Jerusalem, Israel, July 4-9, 1999 : conference proceedings / ed. Gershon Grossman. Vol. 3}, publisher = {Elsevier}, address = {Oxford}, isbn = {0-080-043895-4}, pages = {236 -- 291}, year = {2000}, language = {en} } @article{MelissNeskakisPlettnerMarlianietal.1998, author = {Meliß, Michael and Neskakis, A. and Plettner-Marliani, J. and Lange, C. and H{\"o}velmann, A. and Schumacher, J.}, title = {Waste water recycling supplied by renewable energies : basic conditions and possible treatment technologies}, series = {Renewable energy. Vol. 14 (1998), iss. 1-4. 6th Arab International Solar Energy Conference: Bringing Solar Energy into the Daylight, Muscat, Sultanate of Oman, 29.03.-01.04.1998}, journal = {Renewable energy. Vol. 14 (1998), iss. 1-4. 6th Arab International Solar Energy Conference: Bringing Solar Energy into the Daylight, Muscat, Sultanate of Oman, 29.03.-01.04.1998}, issn = {1879-0682 (E-Book); 0960-1481 (Print)}, pages = {325 -- 331}, year = {1998}, language = {en} } @article{WemhoenerHafnerSchwarzer2000, author = {Wemh{\"o}ner, Carsten and Hafner, Bernd and Schwarzer, Klemens}, title = {Simulation of solar thermal systems with CARNOT blockset in the environment MATLAB-Simulink}, pages = {1 -- 6}, year = {2000}, language = {en} } @inproceedings{FredebeulKreinSteingroever2013, author = {Fredebeul-Krein, Markus and Steingr{\"o}ver, Markus}, title = {Enhancing broadband development and internet usages for improving networks and services in APEC member economies: Bridging the digital divide}, series = {The 19th ITS Biennial Conference 2012 "Moving Forward with Future Technologies: Opening a Platform for All" 18 - 21 November 2012, Thailand}, booktitle = {The 19th ITS Biennial Conference 2012 "Moving Forward with Future Technologies: Opening a Platform for All" 18 - 21 November 2012, Thailand}, publisher = {ITS}, address = {Bangkok}, pages = {13 S.}, year = {2013}, language = {en} } @article{VitusevichFoersterLuethetal.2001, author = {Vitusevich, S. A. and F{\"o}rster, Arnold and L{\"u}th, H. and Belyaev, A. E. and Danylyuk, S. V. and Konakova, R. V. and Sheka, D. I.}, title = {Resonant spectroscopy of electric-field-induced superlattices}, series = {Journal of Applied Physics. 90 (2001), H. 6}, journal = {Journal of Applied Physics. 90 (2001), H. 6}, isbn = {1089-7550}, doi = {10.1063/1.1392956}, pages = {2857 -- 2861}, year = {2001}, language = {en} } @article{StockMalindretosIndlekoferetal.2001, author = {Stock, J. and Malindretos, J. and Indlekofer, K.M. and P{\"o}ttgens, Michael and F{\"o}rster, Arnold and L{\"u}th, Hans}, title = {A Vertical Resonant Tunneling Transistor for Application in Digital Logic Circuits}, series = {IEEE Transactions on Electron Devices (T-ED). 48 (2001), H. 6}, journal = {IEEE Transactions on Electron Devices (T-ED). 48 (2001), H. 6}, isbn = {0018-9383}, pages = {1028 -- 1032}, year = {2001}, language = {en} } @article{SchwarzerSchlenger1988, author = {Schwarzer, Klemens and Schlenger, Barbara J.}, title = {Investigation of fission product aerosol behavior in an HTR containment during severe core-heatup accidents / Barbara J. Schlenger ; K. Schwarzer}, series = {Tagungsbericht : Maritim Kongresszentrum, 17. - 19. Mai '88 Travem{\"u}nde / Kerntechnische Gesellschaft e.V.; Deutsches Atomforum e.V. [Red.: K. G. Bauer]}, journal = {Tagungsbericht : Maritim Kongresszentrum, 17. - 19. Mai '88 Travem{\"u}nde / Kerntechnische Gesellschaft e.V.; Deutsches Atomforum e.V. [Red.: K. G. Bauer]}, publisher = {Inforum}, address = {Bonn}, isbn = {0720-9207}, pages = {179 -- 182}, year = {1988}, language = {en} }