@inproceedings{KohlSchmidtsKloeseretal.2021, author = {Kohl, Philipp and Schmidts, Oliver and Kl{\"o}ser, Lars and Werth, Henri and Kraft, Bodo and Z{\"u}ndorf, Albert}, title = {STAMP 4 NLP - an agile framework for rapid quality-driven NLP applications development}, series = {Quality of Information and Communications Technology. QUATIC 2021}, booktitle = {Quality of Information and Communications Technology. QUATIC 2021}, publisher = {Springer}, address = {Cham}, isbn = {978-3-030-85346-4}, doi = {10.1007/978-3-030-85347-1_12}, pages = {156 -- 166}, year = {2021}, abstract = {The progress in natural language processing (NLP) research over the last years, offers novel business opportunities for companies, as automated user interaction or improved data analysis. Building sophisticated NLP applications requires dealing with modern machine learning (ML) technologies, which impedes enterprises from establishing successful NLP projects. Our experience in applied NLP research projects shows that the continuous integration of research prototypes in production-like environments with quality assurance builds trust in the software and shows convenience and usefulness regarding the business goal. We introduce STAMP 4 NLP as an iterative and incremental process model for developing NLP applications. With STAMP 4 NLP, we merge software engineering principles with best practices from data science. Instantiating our process model allows efficiently creating prototypes by utilizing templates, conventions, and implementations, enabling developers and data scientists to focus on the business goals. Due to our iterative-incremental approach, businesses can deploy an enhanced version of the prototype to their software environment after every iteration, maximizing potential business value and trust early and avoiding the cost of successful yet never deployed experiments.}, language = {en} } @article{KohlerKirschnerHermannsStaatetal.2018, author = {Kohler, Annette and Kirschner-Hermanns, Ruth and Staat, Manfred and Brehmer, Bernhard}, title = {Pathogenese, funktionelle und anatomische Aspekte der weiblichen Belastungsinkontinenz}, series = {Aktuelle Urologie}, volume = {49}, journal = {Aktuelle Urologie}, number = {1}, publisher = {Thieme}, address = {Stuttgart}, issn = {1438-8820}, doi = {10.1055/s-0043-120616}, pages = {47 -- 51}, year = {2018}, abstract = {Der vorliegende Artikel fokussiert sich auf die weibliche Belastungsinkontinenz als Insuffizienz der Speicherfunktion der Blase, auch wenn im klinischen Alltag die Harninkontinenz der Frau h{\"a}ufig verschiedene Ursachen hat und insbesondere eine Belastungsinkontinenz im Alter und bei neurologischer Komorbidit{\"a}t nur selten isoliert vorkommt. Das kleine Becken der Frau ist sowohl als Funktions- als auch als strukturelle Einheit zu betrachten. Dabei unterliegen bei der Frau Blase, Harnr{\"o}hre, Geb{\"a}rmutter und Enddarm sowie die muskul{\"a}ren und ligament{\"o}sen Strukturen des kleinen Beckens durch Fertilit{\"a}tsphase, m{\"o}gliche Schwangerschaften, Geburten und Menopausen-Phase, {\"u}ber das „normale Altern" hinaus, gravierenden Ver{\"a}nderungen. This article focuses on female stress incontinence in the form of pelvic floor dysfunction and urethral sphincter deficiency, although isolated stress incontinence accounts for less than half of all incontinence cases. Especially in women of old age and those with neurological comorbidities, the causes of incontinence are mostly multifactorial. Also it has to be considered that the female bladder, urethra, uterus and rectum as well as the muscular and ligamentous structures of the female pelvis minor are affected by phases of fertility, possible pregnancies, births and menopause in addition to the normal ageing process.}, language = {de} } @article{KolditzAlbinAbeletal.2016, author = {Kolditz, Melanie and Albin, Thivaharan and Abel, Dirk and Fasse, Alessandro and Br{\"u}ggemann, Gert-Peter and Albracht, Kirsten}, title = {Evaluation of foot position and orientation as manipulated variables to control external knee adduction moments in leg extension training}, series = {Computer methods and programs in biomedicine}, volume = {171}, journal = {Computer methods and programs in biomedicine}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0169-2607}, doi = {10.1016/j.cmpb.2016.09.005}, pages = {81 -- 86}, year = {2016}, abstract = {Background and Objective Effective leg extension training at a leg press requires high forces, which need to be controlled to avoid training-induced damage. In order to avoid high external knee adduction moments, which are one reason for unphysiological loadings on knee joint structures, both training movements and the whole reaction force vector need to be observed. In this study, the applicability of lateral and medial changes in foot orientation and position as possible manipulated variables to control external knee adduction moments is investigated. As secondary parameters both the medio-lateral position of the center of pressure and the frontal-plane orientation of the reaction force vector are analyzed. Methods Knee adduction moments are estimated using a dynamic model of the musculoskeletal system together with the measured reaction force vector and the motion of the subject by solving the inverse kinematic and dynamic problem. Six different foot conditions with varying positions and orientations of the foot in a static leg press are evaluated and compared to a neutral foot position. Results Both lateral and medial wedges under the foot and medial and lateral shifts of the foot can influence external knee adduction moments in the presented study with six healthy subjects. Different effects are observed with the varying conditions: the pose of the leg is changed and the direction and center of pressure of the reaction force vector is influenced. Each effect results in a different direction or center of pressure of the reaction force vector. Conclusions The results allow the conclusion that foot position and orientation can be used as manipulated variables in a control loop to actively control knee adduction moments in leg extension training.}, language = {en} } @inproceedings{KolditzAlbinAlbrachtetal.2016, author = {Kolditz, Melanie and Albin, Thivaharan and Albracht, Kirsten and Br{\"u}ggemann, Gert-Peter and Abel, Dirk}, title = {Isokinematic leg extension training with an industrial robot}, series = {6th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) June 26-29, 2016. UTown, Singapore}, booktitle = {6th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) June 26-29, 2016. UTown, Singapore}, doi = {10.1109/BIOROB.2016.7523750}, pages = {950 -- 955}, year = {2016}, language = {de} } @article{KolditzAlbinBrueggemannetal.2016, author = {Kolditz, Melanie and Albin, Thivaharan and Br{\"u}ggemann, Gert-Peter and Abel, Dirk and Albracht, Kirsten}, title = {Robotergest{\"u}tztes System f{\"u}r ein verbessertes neuromuskul{\"a}res Aufbautraining der Beinstrecker}, series = {at - Automatisierungstechnik}, volume = {64}, journal = {at - Automatisierungstechnik}, number = {11}, publisher = {De Gruyter}, address = {Berlin}, issn = {2196-677X}, doi = {10.1515/auto-2016-0044}, pages = {905 -- 914}, year = {2016}, abstract = {Neuromuskul{\"a}res Aufbautraining der Beinstrecker ist ein wichtiger Bestandteil in der Rehabilitation und Pr{\"a}vention von Muskel-Skelett-Erkrankungen. Effektives Training erfordert hohe Muskelkr{\"a}fte, die gleichzeitig hohe Belastungen von bereits gesch{\"a}digten Strukturen bedeuten. Um trainingsinduzierte Sch{\"a}digungen zu vermeiden, m{\"u}ssen diese Kr{\"a}fte kontrolliert werden. Mit heutigen Trainingsger{\"a}ten k{\"o}nnen diese Ziele allerdings nicht erreicht werden. F{\"u}r ein sicheres und effektives Training sollen durch den Einsatz der Robotik, Sensorik, eines Regelkreises sowie Muskel-Skelett-Modellen Belastungen am Zielgewebe direkt berechnet und kontrolliert werden. Auf Basis zweier Vorstudien zu m{\"o}glichen Stellgr{\"o}ßen wird der Aufbau eines robotischen Systems vorgestellt, das sowohl f{\"u}r Forschungszwecke als auch zur Entwicklung neuartiger Trainingsger{\"a}te verwendet werden kann.}, language = {de} } @inproceedings{KolditzAlbinFasseetal.2015, author = {Kolditz, Melanie and Albin, Thivaharan and Fasse, Alessandro and Br{\"u}ggemann, Gert-Peter and Abel, Dirk and Albracht, Kirsten}, title = {Simulative Analysis of Joint Loading During Leg Press Exercise for Control Applications}, series = {IFAC-PapersOnLine}, volume = {48}, booktitle = {IFAC-PapersOnLine}, number = {20}, doi = {10.1016/j.ifacol.2015.10.179}, pages = {435 -- 440}, year = {2015}, language = {en} } @inproceedings{KolditzAlbrachtFasseetal.2015, author = {Kolditz, Melanie and Albracht, Kirsten and Fasse, Alessandro and Albin, Thivaharan and Br{\"u}ggemann, Gert-Peter and Abel, Dirk}, title = {Evaluation of an industrial robot as a leg press training device}, series = {XV International Symposium on Computer Simulation in Biomechanics July 9th - 11th 2015, Edinburgh, UK}, booktitle = {XV International Symposium on Computer Simulation in Biomechanics July 9th - 11th 2015, Edinburgh, UK}, pages = {41 -- 42}, year = {2015}, language = {en} } @inproceedings{KoplinSiemonsOcenValentinetal.2006, author = {Koplin, Tobias J. and Siemons, Maike and Oc{\´e}n-Val{\´e}ntin, C{\´e}sar and Sanders, Daniel and Simon, Ulrich}, title = {Workflow for high throughput screening of gas sensing materials}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1407}, year = {2006}, abstract = {The workflow of a high throughput screening setup for the rapid identification of new and improved sensor materials is presented. The polyol method was applied to prepare nanoparticular metal oxides as base materials, which were functionalised by surface doping. Using multi-electrode substrates and high throughput impedance spectroscopy (HT-IS) a wide range of materials could be screened in a short time. Applying HT-IS in search of new selective gas sensing materials a NO2-tolerant NO sensing material with reduced sensitivities towards other test gases was identified based on iridium doped zinc oxide. Analogous behaviour was observed for iridium doped indium oxide.}, subject = {Biosensor}, language = {en} } @article{KoppSchmeetsGosauetal.2019, author = {Kopp, Alexander and Schmeets, Ralf and Gosau, Martin and Friedrich, Reinhard E. and Fuest, Sandra and Behbahani, Mehdi and Barbeck, Mike and Rutkowski, Rico and Burg, Simon and Kluwe, Lan and Henningsen, Anders}, title = {Production and Characterization of Porous Fibroin Scaffolds for Regenerative Medical Application}, series = {In Vivo}, volume = {33}, journal = {In Vivo}, number = {3}, issn = {1791-7549}, doi = {10.21873/invivo.11536}, pages = {757 -- 762}, year = {2019}, language = {en} } @article{KoppSchunckGosauetal.2020, author = {Kopp, Alexander and Schunck, Laura and Gosau, Martin and Smeets, Ralf and Burg, Simon and Fuest, Sandra and Kr{\"o}ger, Nadja and Zinser, Max and Krohn, Sebastian and Behbahani, Mehdi and K{\"o}pf, Marius and Lauts, Lisa and Rutkowski, Rico}, title = {Influence of the casting concentration on the mechanical and optical properties of Fa/CaCl2-derived silk fibroin membranes}, series = {International Journal of Molecular Sciences}, volume = {21}, journal = {International Journal of Molecular Sciences}, number = {18 art. no. 6704}, publisher = {MDPI}, address = {Basel}, issn = {1422-0067}, doi = {10.3390/ijms21186704}, year = {2020}, abstract = {In this study, we describe the manufacturing and characterization of silk fibroin membranes derived from the silkworm Bombyx mori. To date, the dissolution process used in this study has only been researched to a limited extent, although it entails various potential advantages, such as reduced expenses and the absence of toxic chemicals in comparison to other conventional techniques. Therefore, the aim of this study was to determine the influence of different fibroin concentrations on the process output and resulting membrane properties. Casted membranes were thus characterized with regard to their mechanical, structural and optical assets via tensile testing, SEM, light microscopy and spectrophotometry. Cytotoxicity was evaluated using BrdU, XTT, and LDH assays, followed by live-dead staining. The formic acid (FA) dissolution method was proven to be suitable for the manufacturing of transparent and mechanically stable membranes. The fibroin concentration affects both thickness and transparency of the membranes. The membranes did not exhibit any signs of cytotoxicity. When compared to other current scientific and technical benchmarks, the manufactured membranes displayed promising potential for various biomedical applications. Further research is nevertheless necessary to improve reproducible manufacturing, including a more uniform thickness, less impurity and physiological pH within the membranes.}, language = {en} } @phdthesis{Kotliar2012, author = {Kotliar, Konstantin}, title = {Pathophysiologische Beurteilung und h{\"a}modynamische Analyse von mikrostrukturellen Ver{\"a}nderungen des retinalen Gef{\"a}ßl{\"a}ngsschnittsprofils}, pages = {328 S.}, year = {2012}, language = {ru} } @phdthesis{Kotliar2008, author = {Kotliar, Konstantin}, title = {Functional in-vivo assessment and biofluidmechanical analysis of age-related and pathological microstructural changes in retinal vessels [Elektronische Ressource]}, publisher = {-}, year = {2008}, language = {en} } @phdthesis{Kotliar1998, author = {Kotliar, Konstantin}, title = {Razrabotka i analiz matematicheskih modelei nezavisimogo i svyazannogo funkcionirovaniya drenazhnoi i akkomodacionnoi regulyatornyh sistem chelovecheskogo glaza}, publisher = {-}, pages = {328 S.}, year = {1998}, language = {ru} } @phdthesis{Kotliar2013, author = {Kotliar, Konstantin}, title = {Dynamische retinale Gef{\"a}ßanalyse f{\"u}r die Diagnostik und Fr{\"u}herkennung von System- und Augenerkrankungen vaskul{\"a}rer Genese}, pages = {128 Bl.}, year = {2013}, language = {de} } @incollection{Kotliar2021, author = {Kotliar, Konstantin}, title = {Ocular rigidity: clinical approach}, series = {Ocular Rigidity, Biomechanics and Hydrodynamics of the Eye}, booktitle = {Ocular Rigidity, Biomechanics and Hydrodynamics of the Eye}, editor = {Pallikaris, I. and Tsilimbaris, M. K. and Dastiridou, A. I.}, publisher = {Springer}, address = {Cham}, isbn = {978-3-030-64422-2}, doi = {10.1007/978-3-030-64422-2_2}, pages = {15 -- 43}, year = {2021}, abstract = {The term ocular rigidity is widely used in clinical ophthalmology. Generally it is assumed as a resistance of the whole eyeball to mechanical deformation and relates to biomechanical properties of the eye and its tissues. Basic principles and formulas for clinical tonometry, tonography and pulsatile ocular blood flow measurements are based on the concept of ocular rigidity. There is evidence for altered ocular rigidity in aging, in several eye diseases and after eye surgery. Unfortunately, there is no consensual view on ocular rigidity: it used to make a quite different sense for different people but still the same name. Foremost there is no clear consent between biomechanical engineers and ophthalmologists on the concept. Moreover ocular rigidity is occasionally characterized using various parameters with their different physical dimensions. In contrast to engineering approach, clinical approach to ocular rigidity claims to characterize the total mechanical response of the eyeball to its deformation without any detailed considerations on eye morphology or material properties of its tissues. Further to the previous chapter this section aims to describe clinical approach to ocular rigidity from the perspective of an engineer in an attempt to straighten out this concept, to show its advantages, disadvantages and various applications.}, language = {en} } @article{KotliarBauerZamuraev2006, author = {Kotliar, Konstantin and Bauer, S. M. and Zamuraev, L. A.}, title = {Model of the transversely isotropic spherical layer for estimation of intraocular pressure changes after intravitreal injections / Bauer, S. M. ; Zamuraev, L. A. ; Kotliar, K. E.}, series = {Rossiiskii zhurnal biomekhaniki = Russian Journal of biomechanics. 10 (2006), H. 2}, journal = {Rossiiskii zhurnal biomekhaniki = Russian Journal of biomechanics. 10 (2006), H. 2}, publisher = {-}, isbn = {1812-5123}, pages = {41 -- 47}, year = {2006}, language = {en} } @article{KotliarBaumannVilseretal.2011, author = {Kotliar, Konstantin and Baumann, Marcus and Vilser, Walthard and Lanzl, Ines M.}, title = {Pulse wave velocity in retinal arteries of healthy volunteers}, series = {British Journal of Ophthalmology (eBJO)}, volume = {95}, journal = {British Journal of Ophthalmology (eBJO)}, number = {11}, publisher = {BMJ Publ. Group}, address = {London}, isbn = {1468-2079}, pages = {675 -- 679}, year = {2011}, language = {en} } @article{KotliarDrozdovaShamshinova2006, author = {Kotliar, Konstantin and Drozdova, G. A. and Shamshinova, A. M.}, title = {Ocular hemodinamics and contemporary methods of its assessment.
 Part I. Ocular blood circulation and its quantitative estimation}, series = {National journal Glaucoma}, volume = {Vol. 5}, journal = {National journal Glaucoma}, number = {No. 3}, issn = {2078-4104}, pages = {62 -- 73}, year = {2006}, language = {ru} } @article{KotliarDrozdovaShamshinova2007, author = {Kotliar, Konstantin and Drozdova, G. A. and Shamshinova, A. M.}, title = {Ocular hemodinamics and contemporary methods of its assessment. Part III. Non-invasive methods of assessment of ocular blood flow. 2. Static and dynamic assessment of retinal vessel reaction to stimuli}, series = {National Journal Glaucoma}, volume = {Vol. 6}, journal = {National Journal Glaucoma}, number = {No. 2}, issn = {2078-4104}, pages = {64 -- 71}, year = {2007}, language = {ru} } @article{KotliarDrozdovaShamshinova2007, author = {Kotliar, Konstantin and Drozdova, G. A. and Shamshinova, A. M.}, title = {Ocular hemodinamics and contemporary methods of its assessment. Part III. Non-invasive methods of assessment of ocular blood flow. 1. Assessment of blood cell velocities and flow rates in intraocular vessels and vascular beds}, series = {Journal of Glaucoma}, volume = {Vol. 6}, journal = {Journal of Glaucoma}, number = {1}, issn = {2078-4104}, pages = {61 -- 68}, year = {2007}, language = {ru} }