@article{GoettscheAlexopoulosDuemmleretal.2019, author = {G{\"o}ttsche, Joachim and Alexopoulos, Spiros and D{\"u}mmler, Andreas and Maddineni, S. K.}, title = {Multi-Mirror Array Calculations With Optical Error}, pages = {1 -- 6}, year = {2019}, abstract = {The optical performance of a 2-axis solar concentrator was simulated with the COMSOL Multiphysics® software. The concentrator consists of a mirror array, which was created using the application builder. The mirror facets are preconfigured to form a focal point. During tracking all mirrors are moved simultaneously in a coupled mode by 2 motors in two axes, in order to keep the system in focus with the moving sun. Optical errors on each reflecting surface were implemented in combination with the solar angular cone of ± 4.65 mrad. As a result, the intercept factor of solar radiation that is available to the receiver was calculated as a function of the transversal and longitudinal angles of incidence. In addition, the intensity distribution on the receiver plane was calculated as a function of the incidence angles.}, language = {en} } @article{PoghossianSchultzeSchoening2003, author = {Poghossian, Arshak and Schultze, J. W. and Sch{\"o}ning, Michael Josef}, title = {Multi-parameter detection of (bio-)chemical and physical quantities using an identical transducer principle}, series = {Sensors and Actuators B. 91 (2003), H. 1-3}, journal = {Sensors and Actuators B. 91 (2003), H. 1-3}, isbn = {0925-4005}, pages = {83 -- 91}, year = {2003}, language = {en} } @article{HuckPoghossianBaeckeretal.2015, author = {Huck, Christina and Poghossian, Arshak and B{\"a}cker, Matthias and Reisert, Steffen and Kramer, Friederike and Begoyan, Vardges K. and Buniatyan, Vahe V. and Sch{\"o}ning, Michael Josef}, title = {Multi-parameter sensing using high-k oxide of barium strontium titanate}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431911}, pages = {1259}, year = {2015}, abstract = {High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors. In this work, a Si-based sensor chip containing Pt interdigitated electrodes covered with a thin BST layer (485 nm) has been developed for multi-parameter chemical sensing. The chip has been applied for the contactless measurement of the electrolyte conductivity, the detection of adsorbed charged macromolecules (positively charged polyelectrolytes of polyethylenimine) and the concentration of hydrogen peroxide (H2O2) vapor. The experimental results of functional testing of individual sensors are presented. The mechanism of the BST sensitivity to charged polyelectrolytes and H2O2 vapor has been proposed and discussed.}, language = {en} } @article{ReisertSchneiderGeissleretal.2013, author = {Reisert, Steffen and Schneider, Benno and Geissler, Hanno and Gompel, Matthias van and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Multi-sensor chip for the investigation of different types of metal oxides for the detection of H2O2 in the ppm range}, series = {physica status solidi (a)}, volume = {210}, journal = {physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, pages = {898 -- 904}, year = {2013}, abstract = {In this work, a multi-sensor chip for the investigation of the sensing properties of different types of metal oxides towards hydrogen peroxide in the ppm range is presented. The fabrication process and physical characterization of the multi-sensor chip are described. Pure SnO2 and WO3 as well as Pd- and Pt-doped SnO2 films are characterized in terms of their sensitivity to H2O2. The sensing films have been prepared by drop-coating of water-dispensed nano-powders. A physical characterization, including scanning electron microscopy and X-ray diffraction analysis of the deposited metal-oxide films, was done. From the measurements in hydrogen peroxide atmosphere, it could be shown, that all of the tested metal oxide films are suitable for the detection of H2O2 in the ppm range. The highest sensitivity and reproducibility was achieved using Pt-doped SnO2. Calibration plot of a SnO2, WO3, Pt-, and Pd-doped SnO2 gas sensor for H2O2 concentrations in the ppm range.}, language = {en} } @article{MiyamotoWagnerSchoeningetal.2011, author = {Miyamoto, K. and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, T.}, title = {Multi-well structure for cell culture on the chemical imaging sensor}, publisher = {IEEE}, address = {New York}, pages = {2130 -- 2132}, year = {2011}, language = {en} } @article{AdelsElbersDiehletal.2023, author = {Adels, Klaudia and Elbers, Gereon and Diehl, Bernd and Monakhova, Yulia}, title = {Multicomponent analysis of dietary supplements containing glucosamine and chondroitin: comparative low- and high-field NMR spectroscopic study}, series = {Analytical Sciences}, volume = {2023}, journal = {Analytical Sciences}, publisher = {Springer Verlag}, address = {Cham}, issn = {1348-2246 (Online)}, doi = {10.1007/s44211-023-00433-2}, pages = {13 Seiten}, year = {2023}, abstract = {With the prevalence of glucosamine- and chondroitin-containing dietary supplements for people with osteoarthritis in the marketplace, it is important to have an accurate and reproducible analytical method for the quantitation of these compounds in finished products. NMR spectroscopic method based both on low- (80 MHz) and high- (500-600 MHz) field NMR instrumentation was established, compared and validated for the determination of chondroitin sulfate and glucosamine in dietary supplements. The proposed method was applied for analysis of 20 different dietary supplements. In the majority of cases, quantification results obtained on the low-field NMR spectrometer are similar to those obtained with high-field 500-600 MHz NMR devices. Validation results in terms of accuracy, precision, reproducibility, limit of detection and recovery demonstrated that the developed method is fit for purpose for the marketed products. The NMR method was extended to the analysis of methylsulfonylmethane, adulterant maltodextrin, acetate and inorganic ions. Low-field NMR can be a quicker and cheaper alternative to more expensive high-field NMR measurements for quality control of the investigated dietary supplements. High-field NMR instrumentation can be more favorable for samples with complex composition due to better resolution, simultaneously giving the possibility of analysis of inorganic species such as potassium and chloride.}, language = {en} } @article{SchubertSchoeningMourzinaetal.2001, author = {Schubert, J. and Sch{\"o}ning, Michael Josef and Mourzina, Y. G. and Legin, A. V. and Vlasov, Y. G. and Zander, W. and L{\"u}th, H.}, title = {Multicomponent thin films for electrochemical sensor applications prepared by pulsed laser deposition}, series = {Sensors and Actuators B. 76 (2001), H. 1-3}, journal = {Sensors and Actuators B. 76 (2001), H. 1-3}, isbn = {0925-4005}, pages = {327 -- 330}, year = {2001}, language = {en} } @article{JacobsQuernheim1990, author = {Jacobs, Stephan and Quernheim, Ulrich}, title = {Multicopy ARQ Error Control Techniques for Multipoint Satellite Links / Ulrich Quernheim, Stephan Jacobs}, series = {Proceedings of the IFIP TC 6 International Conference on Information Network and Data Communication : Lillehammer, Norway, 26 - 29 March, 1990 / ed. by Dipak Khakhar ...}, journal = {Proceedings of the IFIP TC 6 International Conference on Information Network and Data Communication : Lillehammer, Norway, 26 - 29 March, 1990 / ed. by Dipak Khakhar ...}, publisher = {North-Holland}, address = {Amsterdam [u.a.]}, isbn = {0-444-88696-6}, pages = {XI, 411 S. : Ill., graph. Darst.}, year = {1990}, language = {en} } @article{AltherrEdererPoettgenetal.2015, author = {Altherr, Lena and Ederer, Thorsten and P{\"o}ttgen, Philipp and Lorenz, Ulf and Pelz, Peter F.}, title = {Multicriterial optimization of technical systems considering multiple load and availability scenarios}, series = {Applied Mechanics and Materials}, volume = {807}, journal = {Applied Mechanics and Materials}, editor = {Pelz, Peter F. and Groche, Peter}, isbn = {1660-9336}, doi = {10.4028/www.scientific.net/AMM.807.247}, pages = {247 -- 256}, year = {2015}, abstract = {Cheap does not imply cost-effective -- this is rule number one of zeitgeisty system design. The initial investment accounts only for a small portion of the lifecycle costs of a technical system. In fluid systems, about ninety percent of the total costs are caused by other factors like power consumption and maintenance. With modern optimization methods, it is already possible to plan an optimal technical system considering multiple objectives. In this paper, we focus on an often neglected contribution to the lifecycle costs: downtime costs due to spontaneous failures. Consequently, availability becomes an issue.}, language = {en} } @article{HartungDondetiCastleford2007, author = {Hartung, Frank and Dondeti, L. and Castleford, F.}, title = {Multimedia Internet KEYing (MIKEY) General Extension Payload for Open Mobile Alliance BCAST LTKM/STKM Transport / Dondeti, L. ; Castleford, D. ; Hartung, F.}, pages = {1 -- 7}, year = {2007}, language = {en} } @article{SawadaNakazawaTakenagaetal.2014, author = {Sawada, Kazuaki and Nakazawa, Hirokazu and Takenaga, Shoko and Hizawa, Takeshi and Futagawa, Masato and Dasai, Fumihiro and Sakurai, Takashi and Okumura, Koichi and Hattori, Toshiaki and Ishida, Makoto}, title = {Multimodal bioimage sensor}, series = {IEICE transactions on fundamentals of electronics, communidations and computer sciences}, volume = {E97-A (2014)}, journal = {IEICE transactions on fundamentals of electronics, communidations and computer sciences}, number = {3}, publisher = {IEICE}, address = {Tokyo}, issn = {0916-8508 (Print) ; 1745-1337 (Online)}, doi = {10.1587/transfun.E97.A.726}, pages = {726 -- 733}, year = {2014}, abstract = {To visualize the biochemical distribution two-dimensionally, we invented a solid-state-type ion image sensor that indicates the chemical activity of solutions and cells. The device, which consists of a CCD array covered with a functionalized membrane to detect charge accumulation, is highly sensitive to changes in the concentration and two-dimensional distribution of ions and biomaterials.}, language = {en} } @article{MonakhovaDiehl2022, author = {Monakhova, Yulia and Diehl, Bernd W.K.}, title = {Multinuclear NMR screening of pharmaceuticals using standardization by 2H integral of a deuterated solvent}, series = {Journal of Pharmaceutical and Biomedical Analysis}, volume = {209}, journal = {Journal of Pharmaceutical and Biomedical Analysis}, number = {Article number: 114530}, publisher = {Elsevier}, isbn = {0731-7085}, doi = {10.1016/j.jpba.2021.114530}, year = {2022}, abstract = {NMR standardization approach that uses the 2H integral of deuterated solvent for quantitative multinuclear analysis of pharmaceuticals is described. As a proof of principle, the existing NMR procedure for the analysis of heparin products according to US Pharmacopeia monograph is extended to the determination of Na+ and Cl- content in this matrix. Quantification is performed based on the ratio of a 23Na (35Cl) NMR integral and 2H NMR signal of deuterated solvent, D2O, acquired using the specific spectrometer hardware. As an alternative, the possibility of 133Cs standardization using the addition of Cs2CO3 stock solution is shown. Validation characteristics (linearity, repeatability, sensitivity) are evaluated. A holistic NMR profiling of heparin products can now also be used for the quantitative determination of inorganic compounds in a single analytical run using a single sample. In general, the new standardization methodology provides an appealing alternative for the NMR screening of inorganic and organic components in pharmaceutical products.}, language = {en} } @article{PrielmeierLang1988, author = {Prielmeier, Franz and Lang, E. W.}, title = {Multinuclear Spin-Lattice Relaxation Time Studies of Supercooled Aqueous LiCl-Solutions / E .W. Lang, F. X. Prielmeier}, series = {Berichte der Bunsen-Gesellschaft f{\"u}r Physikalische Chemie. 92 (1988)}, journal = {Berichte der Bunsen-Gesellschaft f{\"u}r Physikalische Chemie. 92 (1988)}, isbn = {0005-9021}, pages = {717}, year = {1988}, language = {en} } @article{Pieper2011, author = {Pieper, Martin}, title = {Multiobjective optimization with expensive objectives applied to a thermodynamic material design problem}, series = {Proceedings in applied mathematics and mechanics : PAMM. 11 (2011), H. 1}, journal = {Proceedings in applied mathematics and mechanics : PAMM. 11 (2011), H. 1}, publisher = {Wiley}, address = {Weinheim}, isbn = {1617-7061}, pages = {733 -- 734}, year = {2011}, language = {en} } @article{HuckPoghossianKerroumietal.2014, author = {Huck, Christina and Poghossian, Arshak and Kerroumi, Iman and Schusser, Sebastian and B{\"a}cker, Matthias and Zander, Willi and Schubert, J{\"u}rgen and Buniatyan, Vahe V. and Martirosyan, Norayr W. and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Multiparameter sensor chip with Barium Strontium Titanate as multipurpose material}, series = {Electroanalysis}, volume = {26}, journal = {Electroanalysis}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-4109 (E-Journal); 1040-0397 (Print)}, doi = {10.1002/elan.201400076}, pages = {980 -- 987}, year = {2014}, abstract = {It is well known that biochemical and biotechnological processes are strongly dependent and affected by a variety of physico-chemical parameters such as pH value, temperature, pressure and electrolyte conductivity. Therefore, these quantities have to be monitored or controlled in order to guarantee a stable process operation, optimization and high yield. In this work, a sensor chip for the multiparameter detection of three physico-chemical parameters such as electrolyte conductivity, pH and temperature is realized using barium strontium titanate (BST) as multipurpose material. The chip integrates a capacitively coupled four-electrode electrolyte-conductivity sensor, a capacitive field-effect pH sensor and a thin-film Pt-temperature sensor. Due to the multifunctional properties of BST, it is utilized as final outermost coating layer of the processed sensor chip and serves as passivation and protection layer as well as pH-sensitive transducer material at the same time. The results of testing of the individual sensors of the developed multiparameter sensor chip are presented. In addition, a quasi-simultaneous multiparameter characterization of the sensor chip in buffer solutions with different pH value and electrolyte conductivity is performed. To study the sensor behavior and the suitability of BST as multifunctional material under harsh environmental conditions, the sensor chip was exemplarily tested in a biogas digestate.}, language = {en} } @article{Tran2014, author = {Tran, Duc Hung}, title = {Multiple corporate governance attributes and the cost of capital - Evidence from Germany}, series = {The British Accounting Review}, volume = {46}, journal = {The British Accounting Review}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0890-8389}, doi = {https://doi.org/10.1016/j.bar.2014.02.003}, pages = {179 -- 197}, year = {2014}, abstract = {This paper investigates the extent to which corporate governance affects the cost of debt and equity capital of German exchange-listed companies. I examine corporate governance along three dimensions: financial information quality, ownership structure and board structure. The results suggest that firms with high levels of financial transparency and bonus compensations face lower cost of equity. In addition, block ownership is negatively related to firms' cost of equity when the blockholders are other firms, managers or founding-family members. Consistent with the conjecture that agency costs increase with firm size, I find significant cost of debt effects only in the largest German companies. Here, the creditors demand lower cost of debt from firms with block ownerships held by corporations or banks. My findings demonstrate that a uniform set of governance attributes is unlikely to satisfy suppliers of debt and equity capital equally.}, language = {en} } @article{DachwaldSeboldt2005, author = {Dachwald, Bernd and Seboldt, Wolfgang}, title = {Multiple Near-Earth Asteroid Rendezvous and Sample Return Using First Generation Solar Sailcraft}, series = {Acta Astronautica. 57 (2005), H. 11}, journal = {Acta Astronautica. 57 (2005), H. 11}, isbn = {0094-5765}, pages = {864 -- 875}, year = {2005}, language = {en} } @article{PeloniDachwaldCeriotti2017, author = {Peloni, Alessandro and Dachwald, Bernd and Ceriotti, Matteo}, title = {Multiple near-earth asteroid rendezvous mission: Solar-sailing options}, series = {Advances in Space Research}, journal = {Advances in Space Research}, number = {In Press, Corrected Proof}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0273-1177}, doi = {10.1016/j.asr.2017.10.017}, year = {2017}, language = {en} } @article{DachwaldSeboldtRichter2003, author = {Dachwald, Bernd and Seboldt, Wolfgang and Richter, L.}, title = {Multiple Rendezvous and Sample Return Missions to Near-Earth Asteroids Using Solar Sailcraft}, series = {Proceedings of the Fifth IAA International Conference on Low Cost Planetary Missions : 24 - 26 September 2003, ESTEC, Noordwijk, the Netherlands / [comp. by R. A. Harris]}, journal = {Proceedings of the Fifth IAA International Conference on Low Cost Planetary Missions : 24 - 26 September 2003, ESTEC, Noordwijk, the Netherlands / [comp. by R. A. Harris]}, publisher = {ESA}, address = {Noordwijk}, isbn = {92-9092-853-0}, pages = {351 -- 358}, year = {2003}, language = {en} } @article{DachwaldSeboldtRichter2006, author = {Dachwald, Bernd and Seboldt, Wolfgang and Richter, L.}, title = {Multiple rendezvous and sample return missions to near-Earth objects using solar sailcraft / Dachwald, B. ; Seboldt, W. ; Richter, L.}, series = {Acta Astronautica. 59 (2006), H. 8-11}, journal = {Acta Astronautica. 59 (2006), H. 8-11}, isbn = {0094-5765}, pages = {768 -- 776}, year = {2006}, language = {en} }