@article{PoghossianBerndsenSchoening2003, author = {Poghossian, Arshak and Berndsen, Lars and Sch{\"o}ning, Michael Josef}, title = {Chemical sensor as physical sensor: ISFET-based flowvelocity, flow-direction and diffusion-coefficient sensor}, series = {Sensors and Actuators B. 95 (2003), H. 1-3}, journal = {Sensors and Actuators B. 95 (2003), H. 1-3}, isbn = {0925-4005}, pages = {384 -- 390}, year = {2003}, language = {en} } @article{HuckPoghossianBaeckeretal.2014, author = {Huck, Christina and Poghossian, Arshak and B{\"a}cker, Matthias and Reisert, Steffen and Schubert, J. and Zander, W. and Begoyan, V. K. and Buniatyan, V. V. and Sch{\"o}ning, Michael Josef}, title = {Chemical sensors based on a high-k perovskite oxide of barium strontium titanate}, series = {Procedia Engineering}, volume = {87}, journal = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2014.11.258}, pages = {28 -- 31}, year = {2014}, abstract = {High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors for liquids. In this work, BST films have been applied as a sensitive transducer material for a label-free detection of adsorbed charged macromolecules (positively charged polyelectrolytes) and concentration of hydrogen peroxide vapor as well as protection insulator layer for a contactless electrolyte-conductivity sensor. The experimental results of characterization of individual sensors are presented. Special emphasis is devoted towards the development of a capacitively-coupled contactless electrolyte-conductivity sensor.}, language = {en} } @article{PrumeTyholdtCalameetal.2007, author = {Prume, Klaus and Tyholdt, F. and Calame, F. and Raeder, H.}, title = {Chemically derived seeding layer for {100}-textured PZT thin films / Tyholdt, F. ; Calame, F. ; Prume, K. ; Raeder, H. ; Muralt, P.}, series = {Journal of Electroceramics. 19 (2007), H. 4}, journal = {Journal of Electroceramics. 19 (2007), H. 4}, isbn = {1385-3449}, pages = {311 -- 314}, year = {2007}, language = {en} } @article{DuennwaldDemirSiegertetal.2001, author = {D{\"u}nnwald, Thomas and Demir, Ayhan S. and Siegert, Petra and Pohl, Martina and M{\"u}ller, Michael}, title = {ChemInform Abstract: Enantioselective synthesis of (S)-2-Hydroxypropanone derivatives by Benzoylformate Decarboxylase Catalyzed C—C Bond Formation}, series = {Cheminform}, volume = {Vol. 32}, journal = {Cheminform}, number = {Iss. 4}, issn = {1522-2667 (E-Journal); 0931-7597 (Print)}, pages = {Publ. online}, year = {2001}, language = {en} } @article{BaeckerRakowskiPoghossianetal.2013, author = {B{\"a}cker, Matthias and Rakowski, D. and Poghossian, Arshak and Biselli, Manfred and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Chip-based amperometric enzyme sensor system for monitoring of bioprocesses by flow-injection analysis}, series = {Journal of Biotechnology}, volume = {163}, journal = {Journal of Biotechnology}, number = {4}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0168-1656}, doi = {10.1016/j.jbiotec.2012.03.014}, pages = {371 -- 376}, year = {2013}, abstract = {A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses.}, language = {en} } @article{MolinnusHardtKaeveretal.2018, author = {Molinnus, Denise and Hardt, G. and K{\"a}ver, L. and Willenberg, H.S. and Kr{\"o}ger, J.-C. and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Chip-based biosensor for the detection of low adrenaline concentrations to support adrenal venous sampling}, series = {Sensor and Actuators B: Chemical}, volume = {272}, journal = {Sensor and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2018.05.136}, pages = {21 -- 27}, year = {2018}, abstract = {A chip-based amperometric biosensor referring on using the bioelectrocatalytical amplification principle for the detection of low adrenaline concentrations is presented. The adrenaline biosensor has been prepared by modification of a platinum thin-film electrode with an enzyme membrane containing the pyrroloquinoline quinone-dependent glucose dehydrogenase and glutaraldehyde. Measuring conditions such as temperature, pH value, and glucose concentration have been optimized to achieve a high sensitivity and a low detection limit of about 1 nM adrenaline measured in phosphate buffer at neutral pH value. The response of the biosensor to different catecholamines has also been proven. Long-term stability of the adrenaline biosensor has been studied over 10 days. In addition, the biosensor has been successfully applied for adrenaline detection in human blood plasma for future biomedical applications. Furthermore, preliminary experiments have been carried to detect the adrenaline-concentration difference measured in peripheral blood and adrenal venous blood, representing the adrenal vein sampling procedure of a physician.}, language = {en} } @article{KuropkaMuellerHoeckeretal.1989, author = {Kuropka, Rolf and M{\"u}ller, Bettina and H{\"o}cker, Hartwig and Berndt, Heinz}, title = {Chiral stationary phases via hydrosilylation reaction of N-acryloylamino acids : I. Stationary phase with one chiral centre for high-performance liquid chromatography and development of a new derivatization pattern for amino acid enantiomers}, series = {Journal of chromatography A}, journal = {Journal of chromatography A}, number = {481}, isbn = {0021-9673}, pages = {380 -- 386}, year = {1989}, language = {en} } @article{ArtmannHueckHollwegetal.2000, author = {Artmann, Gerhard and Hueck, I. S. and Hollweg, H. G. and Schmid-Sch{\"o}nbein, G. W.}, title = {Chlorpromazine modulates the Morphological Macro- and Microstructure of Endothelial Cells. Hueck, I. S.; Hollweg, H. G.; Schmid-Sch{\"o}nbein, G. W.; Artmann, Gerhard Michael}, series = {American Journal of Physiology. Cell Physiology. 278 (2000), H. 5}, journal = {American Journal of Physiology. Cell Physiology. 278 (2000), H. 5}, isbn = {1522-1563}, pages = {873 -- 878}, year = {2000}, language = {en} } @article{SchoeningBrinkmannRolkaetal.2005, author = {Sch{\"o}ning, Michael Josef and Brinkmann, D. and Rolka, David and Demuth, C. and Poghossian, Arshak}, title = {CIP (cleaning-in-place) suitable "non-glass" pH sensor based on a Ta2O5-gate EIS structure}, series = {Sensors and Actuators B: Chemical. 111-112 (2005)}, journal = {Sensors and Actuators B: Chemical. 111-112 (2005)}, isbn = {0925-4005}, pages = {423 -- 429}, year = {2005}, language = {en} } @article{SchoeningBrinkmannDemuthetal.2004, author = {Sch{\"o}ning, Michael Josef and Brinkmann, D. and Demuth, C. and Poghossian, Arshak}, title = {CIP (cleaning-in-place)-suitable „non-glass" pH sensor based on a Ta2O5-gate EIS structure}, series = {Digest of technical papers : September 12 - 15, 2004, Rome, Italy, Pontificia Universitas Sancto Thoma Aquinate in Urbe / [conference chairperson: C. Di Natale].}, journal = {Digest of technical papers : September 12 - 15, 2004, Rome, Italy, Pontificia Universitas Sancto Thoma Aquinate in Urbe / [conference chairperson: C. Di Natale].}, address = {Roma}, isbn = {88-7621-282-5}, pages = {857 -- 860}, year = {2004}, language = {en} } @article{ArtmannBurnsCanavesetal.2004, author = {Artmann, Gerhard and Burns, Laura and Canaves, Jaume M. and Temiz Artmann, Ayseg{\"u}l}, title = {Circular dichroism spectra of human hemoglobin reveal a reversible structural transition at body temperature}, series = {European Biophysics Journal. 33 (2004), H. 6}, journal = {European Biophysics Journal. 33 (2004), H. 6}, isbn = {1432-1017}, pages = {490 -- 496}, year = {2004}, language = {en} } @article{WollbrinkMasloZimmeretal.2020, author = {Wollbrink, Moritz and Maslo, Semir and Zimmer, Daniel and Abbas, Karim and Arntz, Kristian and Bergs, Thomas}, title = {Clamping and substrate plate system for continuous additive build-up and post-processing of metal parts}, series = {Procedia CIRP}, volume = {93}, journal = {Procedia CIRP}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2212-8271}, doi = {10.1016/j.procir.2020.04.015}, pages = {108 -- 113}, year = {2020}, abstract = {The manufacturing share of laser powder bed fusion (L-PBF) increases in industrial application, but still many process steps are manually operated. Additionally, it is not possible to achieve tight dimensional tolerances or low surfaces roughness. Hence, a process chain has to be set up to combine additive manufacturing (AM) with further machining technologies. To achieve a continuous workpiece flow as basis for further industrialization of L-PBF, the paper presents a novel substrate system and its application on L-PBF machines and post-processing. The substrate system consists of a zero-point clamping system and a matrix-like interface of contact pins to be substantially connected to the workpiece within the L-PBF process.}, language = {en} } @article{StulpeBuschHellwig1993, author = {Stulpe, Werner and Busch, P. and Hellwig, K.-E.}, title = {Classical Representations of Finite-Dimensional Quantum Mechanics. Busch, P.; Hellwig, K.-E.; Stulpe, W.}, series = {International Journal of Theoretical Physics. 32 (1993), H. 3}, journal = {International Journal of Theoretical Physics. 32 (1993), H. 3}, isbn = {1572-9575}, pages = {399 -- 405}, year = {1993}, language = {en} } @article{GrotendorstEitrichKlessetal.2007, author = {Grotendorst, Johannes and Eitrich, T. and Kless, A. and Druska, C.}, title = {Classification of Highly Unbalanced CYP450 Data of Drugs Using Cost Sensitive Machine Learning Techniques / Eitrich, T. ; Kless, A. ; Druska, C. ; Meyer, W. ; Grotendorst J.}, series = {Journal of Chemical Information and Modeling. 47 (2007), H. 1}, journal = {Journal of Chemical Information and Modeling. 47 (2007), H. 1}, isbn = {1549-9596}, pages = {92 -- 103}, year = {2007}, language = {en} } @article{BehnamBeckerWeber2011, author = {Behnam, S. and Becker, A. and Weber, Hans-Joachim}, title = {Clinical benefit and cost-efficiency of minimized perfusion circuits for extracorporeal circulation during cardiac surgery}, series = {Zeitschrift f{\"u}r Herz-, Thorax- und Gef{\"a}ßchirurgie}, volume = {25}, journal = {Zeitschrift f{\"u}r Herz-, Thorax- und Gef{\"a}ßchirurgie}, number = {5}, publisher = {Springer}, address = {Berlin}, issn = {0930-9225}, pages = {305 -- 306}, year = {2011}, language = {en} } @article{ZhangHeimbachScheeretal.2016, author = {Zhang, Jin and Heimbach, Tycho and Scheer, Nico and Barve, Avantika and Li, Wenkui and Lin, Wen and He, Handan}, title = {Clinical Exposure Boost Predictions by Integrating Cytochrome P450 3A4-Humanized Mouse Studies With PBPK Modeling}, series = {Journal of Pharmaceutical Sciences}, volume = {Volume 105}, journal = {Journal of Pharmaceutical Sciences}, number = {Issue 4}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0022-3549}, doi = {doi.org/10.1016/j.xphs.2016.01.021}, pages = {1398 -- 1404}, year = {2016}, abstract = {NVS123 is a poorly water-soluble protease 56 inhibitor in clinical development. Data from in vitro hepatocyte studies suggested that NVS123 is mainly metabolized by CYP3A4. As a consequence of limited solubility, NVS123 therapeutic plasma exposures could not be achieved even with high doses and optimized formulations. One approach to overcome NVS123 developability issues was to increase plasma exposure by coadministrating it with an inhibitor of CYP3A4 such as ritonavir. A clinical boost effect was predicted by using physiologically based pharmacokinetic (PBPK) modeling. However, initial boost predictions lacked sufficient confidence because a key parameter, fraction of drug metabolized by CYP3A4 (ƒₘCYP3A4), could not be estimated with accuracy on account of disconnects between in vitro and in vivo preclinical data. To accurately estimate ƒₘCYP3A4 in human, an in vivo boost effect study was conducted using CYP3A4-humanized mouse model which showed a 33- to 56-fold exposure boost effect. Using a top-down approach, human ƒₘCYP3A4 for NVS123 was estimated to be very high and included in the human PBPK modeling to support subsequent clinical study design. The combined use of the in vivo boost study in CYP3A4-humanized mouse model mice along with PBPK modeling accurately predicted the clinical outcome and identified a significant NVS123 exposure boost (∼42-fold increase) with ritonavir.}, language = {en} } @article{MeyerGranrathFeyerletal.2021, author = {Meyer, Max-Arno and Granrath, Christian and Feyerl, G{\"u}nter and Richenhagen, Johannes and Kaths, Jakob and Andert, Jakob}, title = {Closed-loop platoon simulation with cooperative intelligent transportation systems based on vehicle-to-X communication}, series = {Simulation Modelling Practice and Theory}, volume = {106}, journal = {Simulation Modelling Practice and Theory}, number = {Art. 102173}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1569-190X}, doi = {10.1016/j.simpat.2020.102173}, year = {2021}, language = {en} } @article{SiepmannRupietta1993, author = {Siepmann, Thomas and Rupietta, D.}, title = {Closer to the customer with computerized product support}, series = {Technische Mitteilungen Krupp (1993)}, journal = {Technische Mitteilungen Krupp (1993)}, address = {Essen}, year = {1993}, language = {en} } @article{EngelGemuendeHoltmannetal.2019, author = {Engel, Mareike and Gem{\"u}nde, Andre and Holtmann, Dirk and M{\"u}ller-Renno, Christine and Ziegler, Christiane and Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Clostridium acetobutylicum's connecting world: cell appendage formation in bioelectrochemical systems}, series = {ChemElectroChem}, volume = {7}, journal = {ChemElectroChem}, number = {2}, publisher = {Wiley}, address = {Weinheim}, issn = {2196-0216}, doi = {10.1002/celc.201901656}, pages = {414 -- 420}, year = {2019}, abstract = {Bacterial cell appendix formation supports cell-cell interaction, cell adhesion and cell movement. Additionally, in bioelectrochemical systems (BES), cell appendages have been shown to participate in extracellular electron transfer. In this work, the cell appendix formation of Clostridium acetobutylicum in biofilms of a BES are imaged and compared with conventional biofilms. Under all observed conditions, the cells possess filamentous appendages with a higher number and density in the BES. Differences in the amount of extracellular polymeric substance in the biofilms of the electrodes lead to the conclusion that the cathode can be used as electron donor and the anode as electron acceptor by C. acetobutylicum. When using conductive atomic force microscopy, a current response of about 15 nA is found for the cell appendages from the BES. This is the first report of conductivity for clostridial cell appendices and represents the basis for further studies on their role for biofilm formation and electron transfer.}, language = {en} } @article{ValeroBungCrookston2019, author = {Valero, D. and Bung, Daniel Bernhard and Crookston, B. M.}, title = {Closure to "Energy Dissipation of a Type III Basin under Design and Adverse Conditions for Stepped and Smooth Spillways"}, series = {Journal of Hydraulic Engineering}, volume = {146}, journal = {Journal of Hydraulic Engineering}, number = {2}, publisher = {ASCE}, address = {Reston, Va.}, doi = {10.1061/(ASCE)HY.1943-7900.0001669}, year = {2019}, language = {en} }