@inproceedings{KraftWilhelms2004, author = {Kraft, Bodo and Wilhelms, N.}, title = {Interactive distributed knowledge support for conceptual building design}, isbn = {3-86068-213-X}, year = {2004}, abstract = {In: Net-distributed Co-operation : Xth International Conference on Computing in Civil and Building Engineering, Weimar, June 02 - 04, 2004 ; proceedings / [ed. by Karl Beuke ...] . - Weimar: Bauhaus-Univ. Weimar 2004. - 1. Aufl. . Seite 1-14 ISBN 3-86068-213-X International Conference on Computing in Civil and Building Engineering <10, 2004, Weimar> Summary In our project, we develop new tools for the conceptual design phase. During conceptual design, the coarse functionality and organization of a building is more important than a detailed worked out construction. We identify two roles, first the knowledge engineer who is responsible for knowledge definition and maintenance; second the architect who elaborates the conceptual de-sign. The tool for the knowledge engineer is based on graph technology, it is specified using PROGRES and the UPGRADE framework. The tools for the architect are integrated to the in-dustrial CAD tool ArchiCAD. Consistency between knowledge and conceptual design is en-sured by the constraint checker, another extension to ArchiCAD.}, subject = {CAD}, language = {en} } @article{SchaeferMende1989, author = {Sch{\"a}fer, Horst and Mende, H. H.}, title = {Interaction between laminated g.o.3\% SiFe sheets due to gap-stray fields and edge peaks}, series = {Physica Scripta. 39 (1989), H. 3}, journal = {Physica Scripta. 39 (1989), H. 3}, isbn = {0031-8949}, pages = {397 -- 400}, year = {1989}, language = {en} } @article{PoghossianMalzahnAbouzaretal.2011, author = {Poghossian, Arshak and Malzahn, K. and Abouzar, Maryam H. and Mehndiratta, P. and Katz, E. and Sch{\"o}ning, Michael Josef}, title = {Integration of biomolecular logic gates with field-effect transducers}, series = {Electrochimica Acta. 56 (2011), H. 26}, journal = {Electrochimica Acta. 56 (2011), H. 26}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0013-4686}, pages = {9661 -- 9665}, year = {2011}, language = {en} } @article{RolkaPoghossianSchoening2004, author = {Rolka, David and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Integration of a capacitive EIS sensor into a FIA system for pH and penicillin determination}, series = {Sensors. 4 (2004)}, journal = {Sensors. 4 (2004)}, isbn = {1424-8220}, pages = {84 -- 94}, year = {2004}, language = {en} } @article{SponagelAkbayBeckeretal.1980, author = {Sponagel, Stefan and Akbay, U. and Becker, E. and Krozer, S.}, title = {Instability of slow viscometric flow}, series = {Mechanics Research Communications. 7 (1980), H. 4}, journal = {Mechanics Research Communications. 7 (1980), H. 4}, isbn = {0093-6413}, pages = {199 -- 204}, year = {1980}, language = {en} } @article{SponagelAkbayBecker1985, author = {Sponagel, Stefan and Akbay, U. and Becker, E.}, title = {Instability of plane Couette flow of viscoelastic liquids}, series = {Journal of non-Newtonian fluid mechanics. 18 (1985), H. 2}, journal = {Journal of non-Newtonian fluid mechanics. 18 (1985), H. 2}, isbn = {0377-0257}, pages = {123 -- 141}, year = {1985}, language = {en} } @article{SchrothSchoeningKordosetal.1999, author = {Schroth, P. and Sch{\"o}ning, Michael Josef and Kordos, P. and L{\"u}th, H. and Sch{\"u}tz, S. and Weißbecker, B. and Hummel, Hans E.}, title = {Insectbased BioFETs with improved signal characteristics}, series = {Biosensors \& Bioelectronics. 14 (1999), H. 3}, journal = {Biosensors \& Bioelectronics. 14 (1999), H. 3}, issn = {0956-5663}, pages = {303 -- 308}, year = {1999}, language = {en} } @article{SchuetzCzynskiHummeletal.2000, author = {Sch{\"u}tz, S. and Czynski, J. and Hummel, Hans E. and Sch{\"o}ning, Michael Josef and Schroth, P. and Kordos, P. and L{\"u}th, H.}, title = {Insect meets microelectronics: A BioFET as a first step to bioelectronic microsystems}, series = {Transducers '99 : proceedings of the Tenth International Conference on Solid-State Sensors and Actuators ; 7 - 10 June, 1999, Sendai, Japan / ed.: S. Middelhoek}, journal = {Transducers '99 : proceedings of the Tenth International Conference on Solid-State Sensors and Actuators ; 7 - 10 June, 1999, Sendai, Japan / ed.: S. Middelhoek}, publisher = {Elsevier}, address = {Amsterdam [u.a.]}, pages = {1104 -- 1107}, year = {2000}, language = {en} } @article{SchoeningSchrothLuethetal.2001, author = {Sch{\"o}ning, Michael Josef and Schroth, Peter and L{\"u}th, Hans and Hummel, Hans E. and Sch{\"u}tz, Stefan}, title = {Insect chemoreceptors coupled to silicon transistors as innovative biosensors}, series = {Proceedings of SPIE. 4205 (2001)}, journal = {Proceedings of SPIE. 4205 (2001)}, pages = {152 -- 162}, year = {2001}, language = {en} } @article{KloockMourzinaErmolenkoetal.2004, author = {Kloock, Joachim P. and Mourzina, Y.G. and Ermolenko, Y. and Doll, T. and Schubert, J. and Sch{\"o}ning, Michael Josef}, title = {Inorganic thin-film sensor membranes with PLD-prepared chalcogenide glasses: Challenges and implementation}, series = {Sensors. 4 (2004), H. 10}, journal = {Sensors. 4 (2004), H. 10}, isbn = {1424-8220}, pages = {156 -- 162}, year = {2004}, language = {en} } @article{SchoeningSchubertKloocketal.2002, author = {Sch{\"o}ning, Michael Josef and Schubert, J and Kloock, Joachim P. and Zander, W. and Mourzina, Y. G. and Legin, A. and Vlasov, Y. G. and L{\"u}th, H.}, title = {Innovative thin film techniques for microfabricating electrochemical sensors}, series = {Lecture Notes of the ICB Seminars}, journal = {Lecture Notes of the ICB Seminars}, publisher = {MCB}, address = {Warsaw}, pages = {55 -- 66}, year = {2002}, language = {en} } @article{SchoeningSchubertKloocketal.2001, author = {Sch{\"o}ning, Michael Josef and Schubert, Joachim P. and Kloock, Joachim P. and Zander, W. and Mourzina, Y. G. and Legin, A. and Vlasov, Y. G. and L{\"u}th, H.}, title = {Innovative thin film techniques for microfabricating electrochemical sensors}, series = {Biocybernetics and Biomedical Engineering. 21 (2001), H. 4}, journal = {Biocybernetics and Biomedical Engineering. 21 (2001), H. 4}, isbn = {0208-5216}, pages = {107 -- 119}, year = {2001}, language = {en} } @article{HamadBilattoAdlyetal.2016, author = {Hamad, E. M. and Bilatto, S. E. R. and Adly, N. Y. and Correa, D. S. and Wolfrum, B. and Sch{\"o}ning, Michael Josef and Offenh{\"a}usser, A. and Yakushenko, A.}, title = {Inkjet printing of UV-curable adhesive and dielectric inks for microfluidic devices}, series = {Lab on a Chip}, volume = {16}, journal = {Lab on a Chip}, number = {1}, publisher = {Royal Society of Chemistry}, address = {Cambridge}, issn = {1473-0189}, doi = {10.1039/C5LC01195G}, pages = {70 -- 74}, year = {2016}, abstract = {Bonding of polymer-based microfluidics to polymer substrates still poses a challenge for Lab-On-a-Chip applications. Especially, when sensing elements are incorporated, patterned deposition of adhesives with curing at ambient conditions is required. Here, we demonstrate a fabrication method for fully printed microfluidic systems with sensing elements using inkjet and stereolithographic 3D-printing.}, language = {en} } @article{ArtmannZhouStacheBuettneretal.2002, author = {Artmann, Gerhard and Zhou-Stache, J. and Buettner, R. and Mittermayer, C. [u.a.]}, title = {Inhibition of TNF-alpha induced cell death in HUVEC and Jurkat cells by protocatechuic acid. Zhou-Stache, J.; Buettner, R.; Artmann, Gerhard Michael; Mittermayer, C.; Bosserhoff, A. K.}, series = {Medical and Biological Engineering and Computing. 40 (2002), H. 6}, journal = {Medical and Biological Engineering and Computing. 40 (2002), H. 6}, isbn = {0140-0118}, pages = {698 -- 703}, year = {2002}, language = {en} } @article{StulpeSinger1990, author = {Stulpe, Werner and Singer, Matthias}, title = {Informational Incompleteness of the Observables Sx,Sy,Sz for Spin-1 Systems. Singer, Matthias; Stulpe, W.}, series = {Foundations of Physics. 20 (1990), H. 4}, journal = {Foundations of Physics. 20 (1990), H. 4}, isbn = {1572-9516}, pages = {471 -- 472}, year = {1990}, language = {en} } @article{AlbrachtArampatzis2006, author = {Albracht, Kirsten and Arampatzis, Adamantios}, title = {Influence of the mechanical properties of the muscle-tendon unit on force generation in runners with different running economy}, series = {Biological Cybernetics}, volume = {95}, journal = {Biological Cybernetics}, number = {1}, issn = {1432-0770}, doi = {10.1007/s00422-006-0070-z}, pages = {87 -- 96}, year = {2006}, language = {en} } @article{KoppSchunckGosauetal.2020, author = {Kopp, Alexander and Schunck, Laura and Gosau, Martin and Smeets, Ralf and Burg, Simon and Fuest, Sandra and Kr{\"o}ger, Nadja and Zinser, Max and Krohn, Sebastian and Behbahani, Mehdi and K{\"o}pf, Marius and Lauts, Lisa and Rutkowski, Rico}, title = {Influence of the casting concentration on the mechanical and optical properties of Fa/CaCl2-derived silk fibroin membranes}, series = {International Journal of Molecular Sciences}, volume = {21}, journal = {International Journal of Molecular Sciences}, number = {18 art. no. 6704}, publisher = {MDPI}, address = {Basel}, issn = {1422-0067}, doi = {10.3390/ijms21186704}, year = {2020}, abstract = {In this study, we describe the manufacturing and characterization of silk fibroin membranes derived from the silkworm Bombyx mori. To date, the dissolution process used in this study has only been researched to a limited extent, although it entails various potential advantages, such as reduced expenses and the absence of toxic chemicals in comparison to other conventional techniques. Therefore, the aim of this study was to determine the influence of different fibroin concentrations on the process output and resulting membrane properties. Casted membranes were thus characterized with regard to their mechanical, structural and optical assets via tensile testing, SEM, light microscopy and spectrophotometry. Cytotoxicity was evaluated using BrdU, XTT, and LDH assays, followed by live-dead staining. The formic acid (FA) dissolution method was proven to be suitable for the manufacturing of transparent and mechanically stable membranes. The fibroin concentration affects both thickness and transparency of the membranes. The membranes did not exhibit any signs of cytotoxicity. When compared to other current scientific and technical benchmarks, the manufactured membranes displayed promising potential for various biomedical applications. Further research is nevertheless necessary to improve reproducible manufacturing, including a more uniform thickness, less impurity and physiological pH within the membranes.}, language = {en} } @article{BertzSchoeningMolinnusetal.2024, author = {Bertz, Morten and Sch{\"o}ning, Michael Josef and Molinnus, Denise and Homma, Takayuki}, title = {Influence of temperature, light, and H₂O₂ concentration on microbial spore inactivation: in-situ Raman spectroscopy combined with optical trapping}, series = {Physica status solidi (a) applications and materials science}, journal = {Physica status solidi (a) applications and materials science}, number = {Early View}, publisher = {Wiley-VCH}, address = {Berlin}, issn = {1862-6319 (Online)}, doi = {10.1002/pssa.202300866}, pages = {8 Seiten}, year = {2024}, abstract = {To gain insight on chemical sterilization processes, the influence of temperature (up to 70 °C), intense green light, and hydrogen peroxide (H₂O₂) concentration (up to 30\% in aqueous solution) on microbial spore inactivation is evaluated by in-situ Raman spectroscopy with an optical trap. Bacillus atrophaeus is utilized as a model organism. Individual spores are isolated and their chemical makeup is monitored under dynamically changing conditions (temperature, light, and H₂O₂ concentration) to mimic industrially relevant process parameters for sterilization in the field of aseptic food processing. While isolated spores in water are highly stable, even at elevated temperatures of 70 °C, exposure to H₂O₂ leads to a loss of spore integrity characterized by the release of the key spore biomarker dipicolinic acid (DPA) in a concentration-dependent manner, which indicates damage to the inner membrane of the spore. Intensive light or heat, both of which accelerate the decomposition of H₂O₂ into reactive oxygen species (ROS), drastically shorten the spore lifetime, suggesting the formation of ROS as a rate-limiting step during sterilization. It is concluded that Raman spectroscopy can deliver mechanistic insight into the mode of action of H₂O₂-based sterilization and reveal the individual contributions of different sterilization methods acting in tandem.}, language = {en} } @article{LenzKahmannBehbahanietal.2022, author = {Lenz, Maximilian and Kahmann, Stephanie Lucina and Behbahani, Mehdi and Pennig, Lenhard and Hackl, Michael and Leschinger, Tim and M{\"u}ller, Lars Peter and Wegmann, Kilian}, title = {Influence of rotator cuff preload on fracture configuration in proximal humerus fractures: a proof of concept for fracture simulation}, series = {Archives of Orthopaedic and Trauma Surgery}, journal = {Archives of Orthopaedic and Trauma Surgery}, publisher = {Springer}, address = {Berlin, Heidelberg}, issn = {1434-3916}, doi = {10.1007/s00402-022-04471-9}, year = {2022}, abstract = {Introduction In regard of surgical training, the reproducible simulation of life-like proximal humerus fractures in human cadaveric specimens is desirable. The aim of the present study was to develop a technique that allows simulation of realistic proximal humerus fractures and to analyse the influence of rotator cuff preload on the generated lesions in regards of fracture configuration. Materials and methods Ten cadaveric specimens (6 left, 4 right) were fractured using a custom-made drop-test bench, in two groups. Five specimens were fractured without rotator cuff preload, while the other five were fractured with the tendons of the rotator cuff preloaded with 2 kg each. The humeral shaft and the shortened scapula were potted. The humerus was positioned at 90° of abduction and 10° of internal rotation to simulate a fall on the elevated arm. In two specimens of each group, the emergence of the fractures was documented with high-speed video imaging. Pre-fracture radiographs were taken to evaluate the deltoid-tuberosity index as a measure of bone density. Post-fracture X-rays and CT scans were performed to define the exact fracture configurations. Neer's classification was used to analyse the fractures. Results In all ten cadaveric specimens life-like proximal humerus fractures were achieved. Two III-part and three IV-part fractures resulted in each group. The preloading of the rotator cuff muscles had no further influence on the fracture configuration. High-speed videos of the fracture simulation revealed identical fracture mechanisms for both groups. We observed a two-step fracture mechanism, with initial impaction of the head segment against the glenoid followed by fracturing of the head and the tuberosities and then with further impaction of the shaft against the acromion, which lead to separation of the tuberosities. Conclusion A high energetic axial impulse can reliably induce realistic proximal humerus fractures in cadaveric specimens. The preload of the rotator cuff muscles had no influence on initial fracture configuration. Therefore, fracture simulation in the proximal humerus is less elaborate. Using the presented technique, pre-fractured specimens are available for real-life surgical education.}, language = {en} } @article{DuongNguyenTranetal.2015, author = {Duong, Minh Tuan and Nguyen, Nhu Huynh and Tran, Thanh Ngoc and Tolba, R. H. and Staat, Manfred}, title = {Influence of refrigerated storage on tensile mechanical properties of porcine liver and spleen}, series = {International biomechanics}, volume = {Vol. 2}, journal = {International biomechanics}, number = {Iss. 1}, publisher = {Taylor \& Francis}, address = {London}, issn = {2333-5432}, doi = {10.1080/23335432.2015.1049295}, pages = {79 -- 88}, year = {2015}, language = {en} }