@article{ArtmannZhouStacheBuettneretal.2002, author = {Artmann, Gerhard and Zhou-Stache, J. and Buettner, R. and Mittermayer, C. [u.a.]}, title = {Inhibition of TNF-alpha induced cell death in HUVEC and Jurkat cells by protocatechuic acid. Zhou-Stache, J.; Buettner, R.; Artmann, Gerhard Michael; Mittermayer, C.; Bosserhoff, A. K.}, series = {Medical and Biological Engineering and Computing. 40 (2002), H. 6}, journal = {Medical and Biological Engineering and Computing. 40 (2002), H. 6}, isbn = {0140-0118}, pages = {698 -- 703}, year = {2002}, language = {en} } @article{WeberHekmatKananietal.2002, author = {Weber, Hans-Joachim and Hekmat, Khosro and Kanani, Reza and Ahmadpour, R. [u.a.]}, title = {Haben Mobiltelefone einen negativen Einfluss auf moderne Herzschrittmacher? / K. Hekmat, R. Kanani, R. Ahmadpour, G. Lauterbach, M. S{\"u}dkamp, H.-J. Weber, E. R. de Vivie}, series = {Kardiotechnik. 11 (2002), H. 2}, journal = {Kardiotechnik. 11 (2002), H. 2}, isbn = {0941-2670}, pages = {45 -- 47}, year = {2002}, language = {de} } @inproceedings{KraftMeyerNagl2002, author = {Kraft, Bodo and Meyer, Oliver and Nagl, Manfred}, title = {Graph technology support for conceptual design in civil engineering}, isbn = {3-18-318004-9}, year = {2002}, abstract = {In: Advances in intelligent computing in engineering : proceedings of the 9.International EG-ICE Workshop ; Darmstadt, (01 - 03 August) 2002 / Martina Schnellenbach-Held ... (eds.) . - D{\"u}sseldorf: VDI-Verl., 2002 .- Fortschritt-Berichte VDI, Reihe 4, Bauingenieurwesen ; 180 ; S. 1-35 The paper describes a novel way to support conceptual design in civil engineering. The designer uses semantical tools guaranteeing certain internal structures of the design result but also the fulfillment of various constraints. Two different approaches and corresponding tools are discussed: (a) Visually specified tools with automatic code generation to determine a design structure as well as fixing various constraints a design has to obey. These tools are also valuable for design knowledge specialist. (b) Extensions of existing CAD tools to provide semantical knowledge to be used by an architect. It is sketched how these different tools can be combined in the future. The main part of the paper discusses the concepts and realization of two prototypes following the two above approaches. The paper especially discusses that specific graphs and the specification of their structure are useful for both tool realization projects.}, subject = {CAD}, language = {en} } @article{MuellerVeggianCesariDeNardoetal.2002, author = {M{\"u}ller-Veggian, Mattea and Cesari, V. and De Nardo, L. and Colautti, P.}, title = {First microdosimetric measurements with a 10b-loaded TEPC}, series = {Annual report / Istituto Nazionale di Fisica Nucleare, LNL, Laboratori Nazionali di Legnaro. 2001 (2002)}, journal = {Annual report / Istituto Nazionale di Fisica Nucleare, LNL, Laboratori Nazionali di Legnaro. 2001 (2002)}, isbn = {88-7337-002-0}, pages = {110 -- 111}, year = {2002}, language = {en} } @article{SchoeningPoghossianSchultzeetal.2002, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak and Schultze, J. W. and L{\"u}th, H.}, title = {Field-effect based multifunctional hybrid sensor module for the determination of both (bio-)chemical and physical paramters}, series = {Proceedings of SPIE. 4576 (2002)}, journal = {Proceedings of SPIE. 4576 (2002)}, pages = {149 -- 159}, year = {2002}, language = {en} } @article{SchoeningSimonisKringsetal.2002, author = {Sch{\"o}ning, Michael Josef and Simonis, A. and Krings, T. and L{\"u}th, H. and Wang, J.}, title = {Evaluation of a chip-based thin-film / thick-film sensor hybrid for (bio-)chemical analysis}, series = {Electroanalysis}, volume = {14}, journal = {Electroanalysis}, number = {13}, issn = {1040-0397}, pages = {955 -- 958}, year = {2002}, language = {en} } @book{Laack2002, author = {Laack, Walter van}, title = {Eine bessere Geschichte unserer Welt / Bd. 3. Der Tod}, publisher = {van Laack}, address = {Aachen}, isbn = {978-3-8311-3581-3}, pages = {248 S.}, year = {2002}, language = {de} } @article{SchoeningWangKrauseetal.2002, author = {Sch{\"o}ning, Michael Josef and Wang, Josepf and Krause, Robin and Block, Kirstin and Musameh, Mustafa and Mulchandani, Ashok and Mulchandani, Priti and Chen, Wilfred}, title = {Dual amperometric-potentiometric biosensor detection system for monitoring organophosphorus neurotoxins}, series = {Analyica Chimica Acta. 469 (2002), H. 2}, journal = {Analyica Chimica Acta. 469 (2002), H. 2}, isbn = {0378-4304}, pages = {197 -- 203}, year = {2002}, language = {en} } @article{MaggakisKelemenBiselliArtmann2002, author = {Maggakis-Kelemen, Christina and Biselli, Manfred and Artmann, Gerhard}, title = {Determination of the elastic shear modulus of cultured human red blood cells}, series = {Biomedizinische Technik. 47 (2002), H. Suppl. 1 Pt. 1}, journal = {Biomedizinische Technik. 47 (2002), H. Suppl. 1 Pt. 1}, isbn = {0013-5585}, pages = {106 -- 109}, year = {2002}, language = {en} } @article{StreunBrandenburgLarueetal.2002, author = {Streun, M. and Brandenburg, G. and Larue, H. and Zimmermann, E. and Ziemons, Karl and Halling, H.}, title = {Coincidence detection by digital processing of free-running sampled pulses}, series = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, volume = {487}, journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, number = {3}, isbn = {0168-9002}, pages = {530 -- 534}, year = {2002}, abstract = {Coincident events in two scintillator crystals coupled to photomultipliers (PMT) are detected by processing just the digital data of the recorded pulses. For this purpose the signals from both PMTs are continuously sampled by free-running ADCs at a sampling rate of 40 MHz. For each sampled pulse the starting time is determined by processing the pulse data. Even a fairly simple interpolating algorithm results in a FWHM of about 2 ns.}, language = {en} } @article{PoghossianBerndsenSchoening2002, author = {Poghossian, Arshak and Berndsen, L. and Sch{\"o}ning, Michael Josef}, title = {Chemical sensor as a physical sensor: ISFET-based flowvelocity, flow-direction and diffusion-coefficient sensor}, series = {Book of abstracts / ed. by J. Saneistr.}, journal = {Book of abstracts / ed. by J. Saneistr.}, publisher = {Czech Technical University, Faculty of Electrical Engineering, Department of Measurement}, address = {Prague}, isbn = {80-01-02576-4}, pages = {649 -- 652}, year = {2002}, language = {en} } @article{KloockMourzinaYoshinobuetal.2002, author = {Kloock, Joachim P. and Mourzina, Y.G. and Yoshinobu, T. and Schubert, J. and Sch{\"o}ning, Michael Josef}, title = {Chalkogenidglassensoren f{\"u}r die Schwermetallanalytik}, series = {Sensoren und Mess-Systeme : Vortr{\"a}ge der 11. ITG/GMA-Fachtagung vom 11. bis 12. M{\"a}rz 2002 in Ludwigsburg / Veranst.: Informationstechnische Gesellschaft im VDE (ITG) ... Wiss. Tagungsleitung: C. D. Kohl ....}, journal = {Sensoren und Mess-Systeme : Vortr{\"a}ge der 11. ITG/GMA-Fachtagung vom 11. bis 12. M{\"a}rz 2002 in Ludwigsburg / Veranst.: Informationstechnische Gesellschaft im VDE (ITG) ... Wiss. Tagungsleitung: C. D. Kohl ....}, publisher = {VDE-Verl.}, address = {Berlin [u.a.]}, isbn = {3-8007-2675-0}, pages = {395 -- 398}, year = {2002}, language = {de} } @article{TemizArtmannYalcinResmietal.2002, author = {Temiz Artmann, Ayseg{\"u}l and Yalcin, Ozlem and Resmi, Halil and Baskurt, Oguz K.}, title = {Can white blood cell activation be one of the major factors that affect hemorheological parameters during and after exercise?}, series = {Clinical Hemorheology and Microcirculation. 26 (2002), H. 3}, journal = {Clinical Hemorheology and Microcirculation. 26 (2002), H. 3}, isbn = {1386-0291}, pages = {189 -- 193}, year = {2002}, language = {en} } @article{KeusgenJuengerSchoening2002, author = {Keusgen, M. and J{\"u}nger, M. and Sch{\"o}ning, Michael Josef}, title = {Biosensoric detection of the cysteine sulphoxide alliin}, series = {Book of abstracts / ed. by J. Saneistr.}, journal = {Book of abstracts / ed. by J. Saneistr.}, publisher = {Czech Technical University, Faculty of Electrical Engineering, Department of Measurement}, address = {Prague}, isbn = {80-01-02576-4}, pages = {1175 -- 1178}, year = {2002}, language = {en} } @article{KotliarLanzl2002, author = {Kotliar, Konstantin and Lanzl, I. M.}, title = {Biomechanical modeling of the aqueous humor outflow after non-penetrating glaucoma filtration surgery in the human eye}, series = {Acta of bioengineering and biomechanics}, volume = {Vol. 4}, journal = {Acta of bioengineering and biomechanics}, number = {Suppl. 1}, issn = {1509-409X}, pages = {728 -- 729}, year = {2002}, language = {de} } @article{SchrothWeissbeckerSchuetzetal.2002, author = {Schroth, P. and Weißbecker, B. and Sch{\"u}tz, S. and Ecken, H. and Yoshinobu, T. and L{\"u}th, H. and Sch{\"o}ning, Michael Josef}, title = {Bioelectronic signal processing - intact chemoreceptors coupled to field-effect devices}, series = {Lecture Notes of the ICB Seminars}, journal = {Lecture Notes of the ICB Seminars}, publisher = {MCB}, address = {Warsaw}, pages = {28 -- 42}, year = {2002}, language = {en} } @article{ReisselBitschKiesslingetal.2002, author = {Reißel, Martin and Bitsch, G. and Kießling, A. and Mawick, G.}, title = {Betriebsfestigkeitsanalyse von T{\"u}rschließvorg{\"a}ngen auf der Basis transienter FEM Simulationen / Bitsch, G. ; Kießling, A. ; Mawick, G. ; Reißel, M. ; Tokar, G. ; Wirth, C.}, series = {LS DYNA Forum, 2002; V25}, journal = {LS DYNA Forum, 2002; V25}, pages = {1 -- 10}, year = {2002}, language = {de} } @article{HillenUnglaubenWirtz2002, author = {Hillen, Walter and Unglauben, F. and Wirtz, G.}, title = {Architectures and Modeling of Distributed Image Information Systems. Unglauben, F.; Hillen, W.; Wirtz, G.}, series = {Proceedings : July 14 - 18, 2002, Orlando, Florida, USA ; [jointly with the 8th International Conference on Information Systems Analysis and Synthesis (ISAS 2002)] / organized by IIIS, International Institute of Informatics and Systemics. Ed. by Nagib Callaos}, journal = {Proceedings : July 14 - 18, 2002, Orlando, Florida, USA ; [jointly with the 8th International Conference on Information Systems Analysis and Synthesis (ISAS 2002)] / organized by IIIS, International Institute of Informatics and Systemics. Ed. by Nagib Callaos}, publisher = {IIIS}, address = {Orlando, Fla.}, isbn = {9800781501}, year = {2002}, language = {en} } @book{SanderRoy2002, author = {Sander, Volker and Roy, Alain}, title = {Advance Reservation API / Roy, Alain ; Sander, Volker}, publisher = {Global Grid Forum}, pages = {26 S.}, year = {2002}, language = {en} } @article{StreunBrandenburgLarueetal.2002, author = {Streun, M. and Brandenburg, G. and Larue, H. and Zimmermann, E. and Ziemons, Karl and Halling, H.}, title = {A PET system with free running ADCs}, series = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, volume = {486}, journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, number = {1-2}, issn = {0168-9002}, pages = {18 -- 21}, year = {2002}, abstract = {A small PET system has been built up with two multichannel photomultipliers, which are attached to a matrix of 64 single LSO crystals each. The signal from each multiplier is being sampled continuously by a 12 bit ADC at a sampling frequency of 40 MHz. In case of a scintillation pulse a subsequent FPGA sends the corresponding set of samples together with the channel information and a time mark to the host computer. The data transfer is performed with a rate of 20 MB/s. On the host all necessary information is extracted from the data. The pulse energy is determined, coincident events are detected and multiple hits within one matrix can be identified. In order to achieve a narrow time window the pulse starting time is refined further than the resolution of the time mark (=25 ns) would allow. This is possible by interpolating between the pulse samples. First data obtained from this system will be presented. The system is part of developments for a much larger system and has been created to study the feasibility and performance of the technique and the hardware architecture.}, language = {en} }