@article{Staat2003, author = {Staat, Manfred}, title = {Shakedown and ratchetting under tension-torsion loadings: analysis and experiments}, year = {2003}, abstract = {Structural design analyses are conducted with the aim of verifying the exclusion of ratchetting. To this end it is important to make a clear distinction between the shakedown range and the ratchetting range. The performed experiment comprised a hollow tension specimen which was subjected to alternating axial forces, superimposed with constant moments. First, a series of uniaxial tests has been carried out in order to calibrate a bounded kinematic hardening rule. The load parameters have been selected on the basis of previous shakedown analyses with the PERMAS code using a kinematic hardening material model. It is shown that this shakedown analysis gives reasonable agreement between the experimental and the numerical results. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis.}, subject = {Einspielen }, language = {en} } @inproceedings{KraftNagl2003, author = {Kraft, Bodo and Nagl, Manfred}, title = {Semantic tool support for conceptual design}, year = {2003}, abstract = {ITCE-2003 - 4th Joint Symposium on Information Technology in Civil Engineering ed Flood, I., Seite 1-12, ASCE (CD-ROM), Nashville, USA In this paper we discussed graph based tools to support architects during the conceptual design phase. Conceptual Design is defined before constructive design; the used concepts are more abstract. We develop two graph based approaches, a topdown using the graph rewriting system PROGRES and a more industrially oriented approach, where we extend the CAD system ArchiCAD. In both approaches, knowledge can be defined by a knowledge engineer, in the top-down approach in the domain model graph, in the bottom-up approach in the in an XML file. The defined knowledge is used to incrementally check the sketch and to inform the architect about violations of the defined knowledge. Our goal is to discover design error as soon as possible and to support the architect to design buildings with consideration of conceptual knowledge.}, subject = {CAD}, language = {en} } @article{StreunBrandenburgLarueetal.2003, author = {Streun, M. and Brandenburg, G. and Larue, H. and Saleh, H. and Zimmermann, E. and Ziemons, Karl and Halling, H.}, title = {Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET}, series = {2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, journal = {2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, issn = {1082-3654}, pages = {1636 -- 1639}, year = {2003}, abstract = {A feasible way to gain the depth of interaction information in a PET scanner is the use of phoswich detectors. In general the layer of interaction is identified front the pulse shape of the corresponding scintillator material. In this work pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could he kept simple due to an additional slow component in the light decay of the LuYAP pulse. At the same time the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time.}, language = {en} } @article{StreunBrandenburgLarueetal.2003, author = {Streun, M. and Brandenburg, G. and Larue, H. and Saleh, H. and Zimmermann, E. and Ziemons, Karl and Halling, H.}, title = {Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET}, series = {IEEE Transactions on Nuclear Science}, volume = {50}, journal = {IEEE Transactions on Nuclear Science}, number = {3}, isbn = {0018-9499}, pages = {344 -- 347}, year = {2003}, abstract = {A feasible way to gain the depth of interaction information in a positron emission tomography scanner is the use of phoswich detectors. In general, the layer of interaction is identified from the pulse shape of the corresponding scintillator material. In this work, pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could be kept simple because of an additional slow component in the light decay of the LuYAP pulse. At the same time, the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time.}, language = {en} } @incollection{StaatHeitzer2003, author = {Staat, Manfred and Heitzer, Michael}, title = {Probabilistic limit and shakedown problems}, series = {Numerical methods for limit and shakedown analysis. Deterministic and probabilistic problems}, volume = {15}, booktitle = {Numerical methods for limit and shakedown analysis. Deterministic and probabilistic problems}, editor = {Staat, Manfred and Heitzer, Michael}, publisher = {John von Neumann Institute for Computing (NIC)}, address = {J{\"u}lich}, isbn = {3-00-010001-6}, pages = {217 -- 268}, year = {2003}, language = {en} } @article{StaatHeitzer2003, author = {Staat, Manfred and Heitzer, M.}, title = {Probabilistic limit and shakedown problems}, series = {Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M.}, journal = {Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M.}, publisher = {John von Neumann Institute for Computing (NIC)}, address = {J{\"u}lich}, isbn = {3-00-010001-6}, pages = {217 -- 268}, year = {2003}, language = {en} } @article{YoshinobuSchoeningOttoetal.2003, author = {Yoshinobu, T. and Sch{\"o}ning, Michael Josef and Otto, R. and Furuichi, K. and Mourzina, Y. and Ermelenko, Y. and Iwasaki, H.}, title = {Portable light-addressable potentiometric sensor (LAPS) for multisensor applications}, series = {Sensors and Actuators B. 95 (2003), H. 1-3}, journal = {Sensors and Actuators B. 95 (2003), H. 1-3}, isbn = {0925-4005}, pages = {352 -- 356}, year = {2003}, language = {en} } @inproceedings{DigelTemizArtmannNojimaetal.2003, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Nojima, H. and Artmann, Gerhard}, title = {Plasma-generated cluster ions' effects on indoor microflora : [abstract]}, year = {2003}, abstract = {Recently, SHARP corporation has developed the world's first "Plasma Cluster Ions® (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new Plasma Cluster Device releases positive and negative ions into the air, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. In the past, phenomenological tests on the efficacy of the PCI air purification technology on microbial cells have been conducted. In most cases, it has been shown that PCI demonstrated strongly pronounced killing effects on microorganisms. However, the particular mechanisms of PCI action still have to be uncovered.}, subject = {Clusterion}, language = {en} } @inproceedings{DigelTemizArtmannArtmannetal.2003, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Artmann, Gerhard and Nojima, H.}, title = {Plasma cluster ions (PCI) influence on microbial cells viability : [abstract]}, year = {2003}, abstract = {Recently, SHARP corporation has developed the world's first "Plasma Cluster Ions (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new plasma cluster device releases into the air positive and negative ions, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. A lot of phenomenological tests of the PCI air purification technology on microbial cells have been conducted. And, in most cases, it has been shown that PCI demonstrate strongly pronounced killing effect. Although, the particular mechanisms of PCI action are still not evident. We studied variations in resistance to PCI among gram-positive airborne microorganisms, as well as some dose-dependent, spatial, cultural and biochemical properties of PCI action in respect of Staphylococcus spp, Enterococcus spp, Micrococcus spp.}, subject = {Clusterion}, language = {en} } @book{StaatHeitzer2003, author = {Staat, Manfred and Heitzer, Michael}, title = {Numerical methods for limit and shakedown analysis. Deterministic and probabilistic problems.}, publisher = {John von Neumann Institute for Computing (NIC)}, address = {J{\"u}lich}, isbn = {3-00-010001-6}, pages = {2, xiii, 282 Seiten}, year = {2003}, language = {en} } @article{PoghossianSchultzeSchoening2003, author = {Poghossian, Arshak and Schultze, J. W. and Sch{\"o}ning, Michael Josef}, title = {Multi-parameter detection of (bio-)chemical and physical quantities using an identical transducer principle}, series = {Sensors and Actuators B. 91 (2003), H. 1-3}, journal = {Sensors and Actuators B. 91 (2003), H. 1-3}, isbn = {0925-4005}, pages = {83 -- 91}, year = {2003}, language = {en} } @article{YoshinobuErmelenkoMourzinaetal.2003, author = {Yoshinobu, T. and Ermelenko, Y. and Mourzina, Y. and Sch{\"o}ning, Michael Josef and Iwasaki, H. and Vlasov, Y.}, title = {Multi-component analysis based on the light-addressable potentiometric sensor (LAPS)}, series = {Proceedings : 11th international conference Sensor 2003; 13 - 15 May 2003, Exhibition Centre Nuremberg, Germany}, journal = {Proceedings : 11th international conference Sensor 2003; 13 - 15 May 2003, Exhibition Centre Nuremberg, Germany}, publisher = {AMA Service}, address = {Wunstorf}, pages = {141 -- 144}, year = {2003}, language = {en} } @article{KotliarSvetlovaMakarovetal.2003, author = {Kotliar, Konstantin and Svetlova, O. V. and Makarov, F. N. and Zaseeva, M. V.}, title = {Morfologicheskie i funktsional'nye osobennosti resnichnogo poiaska khrustalika kak kliuchevogo ispolnitel'nogo zvena v mekhanizme akkommodatsii glaza cheloveka = Morpho-functional characteristics of lens ciliary body as a key mechanism of accommodation in}, series = {Morfologiia (Saint Petersburg, Russia). 123 (2003), H. 3}, journal = {Morfologiia (Saint Petersburg, Russia). 123 (2003), H. 3}, publisher = {-}, isbn = {1026-3543}, pages = {7 -- 16}, year = {2003}, language = {en} } @article{HekmatKananiLauterbachetal.2003, author = {Hekmat, Khosro and Kanani, Reza and Lauterbach, Gerhard and S{\"u}dkamp, Michael and Ahmadpoor, Tooraj and Weber, Hans-Joachim and Mehlhorn, Uwe}, title = {Moderne Herzschrittmachersysteme wenig st{\"o}ranf{\"a}llig durch Mobilfunktelefone}, series = {Deutsches {\"A}rzteblatt. 100 (2003), H. 38}, journal = {Deutsches {\"A}rzteblatt. 100 (2003), H. 38}, pages = {A2438 -- A2445}, year = {2003}, language = {de} } @article{SchoeningPoghossianSchultze2003, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak and Schultze, Joachim W.}, title = {Measuring seven parameters by two ISFET modules in a microcell set-up}, series = {Int. Journal of Computational Engineering Science. 4 (2003), H. 2}, journal = {Int. Journal of Computational Engineering Science. 4 (2003), H. 2}, isbn = {1465-8763}, pages = {257 -- 260}, year = {2003}, language = {en} } @misc{Kraft2003, author = {Kraft, Bodo}, title = {LexiCAD Step by Step : B{\"u}rogeb{\"a}ude : Erstellen eines Grundrisses mit RoomObjects und LexiCAD}, year = {2003}, abstract = {11 Seiten, 22 Abbildungen 1. Konstruktion des Außenumrisses 2. Festlegung der inneren R{\"a}ume 3. Einf{\"u}gen der RoomLinks 4. Wallgenerator}, subject = {CAD}, language = {de} } @article{MourzinaMaiPoghossianetal.2003, author = {Mourzina, Y. and Mai, T. and Poghossian, Arshak and Ermolenko, Y. and Yoshinobu, T. and Vlasov, Y. and Iwasaki, H. and Sch{\"o}ning, Michael Josef}, title = {K+-selective field-effect sensors as transducers for bioelectronic applications}, series = {Electrochimica Acta. 48 (2003), H. 20-22}, journal = {Electrochimica Acta. 48 (2003), H. 20-22}, isbn = {0013-4686}, pages = {3333 -- 3339}, year = {2003}, language = {en} } @article{SponagelUngerSpies2003, author = {Sponagel, Stefan and Unger, J. and Spies, K. H.}, title = {H{\"a}rtebegriff im Zusammenhang mit Vernetzung, Bruchdehnung und Dauerfestigkeit eines Elastomers}, series = {Kautschuk Gummi Kunststoffe. 56 (2003), H. 11}, journal = {Kautschuk Gummi Kunststoffe. 56 (2003), H. 11}, isbn = {0948-3276}, pages = {608 -- 613}, year = {2003}, language = {de} } @article{BaroudWuBohneretal.2003, author = {Baroud, G. and Wu, J.Z. and Bohner, M and Sponagel, Stefan and Steffen, T.}, title = {How to determine the permeability for cement infiltration into osteoporotic cancellous bone}, series = {Medical Engineering \& Physics. 25 (2003), H. 4}, journal = {Medical Engineering \& Physics. 25 (2003), H. 4}, issn = {1350-4533}, pages = {283 -- 288}, year = {2003}, abstract = {Cement augmentation is an emerging surgical procedure in which bone cement is used to infiltrate and reinforce osteoporotic vertebrae. Although this infiltration procedure has been widely applied, it is performed empirically and little is known about the flow characteristics of cement during the injection process. We present a theoretical and experimental approach to investigate the intertrabecular bone permeability during the infiltration procedure. The cement permeability was considered to be dependent on time, bone porosity, and cement viscosity in our analysis. In order to determine the time-dependent permeability, ten cancellous bone cores were harvested from osteoporotic vertebrae, infiltrated with acrylic cement at a constant flow rate, and the pressure drop across the cores during the infiltration was measured. The viscosity dependence of the permeability was determined based on published experimental data. The theoretical model for the permeability as a function of bone porosity and time was then fit to the testing data. Our findings suggest that the intertrabecular bone permeability depends strongly on time. For instance, the initial permeability (60.89 mm4/N.s) reduced to approximately 63\% of its original value within 18 seconds. This study is the first to analyze cement flow through osteoporotic bone. The theoretical and experimental models provided in this paper are generic. Thus, they can be used to systematically study and optimize the infiltration process for clinical practice.}, subject = {Osteoporose}, language = {en} } @article{BresselSchultzeKhanetal.2003, author = {Bressel, A. and Schultze, J.W. and Khan, W. and Wolfaardt, G. M. and Rohns, H.-P. and Irmscher, R. and Sch{\"o}ning, Michael Josef}, title = {High resolution gravimetric, optical and electrochemical investigations of microbial biofilm formation in aqueous systems}, series = {Electrochimica Acta. 48 (2003), H. 20-22}, journal = {Electrochimica Acta. 48 (2003), H. 20-22}, isbn = {0013-4686}, pages = {3363 -- 3372}, year = {2003}, language = {en} }