@article{WernerWagnerMiyamotoetal.2012, author = {Werner, Frederik and Wagner, Torsten and Miyamoto, Ko-ichiro and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {High speed and high resolution chemical imaging based on a new type of OLED-LAPS set-up}, series = {Sensors and Actuators B: Chemical}, volume = {175}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2011.12.102}, pages = {118 -- 122}, year = {2012}, abstract = {Light-addressable potentiometric sensors (LAPS) are field-effect-based sensors. A modulated light source is used to define the particular measurement spot to perform spatially resolved measurements of chemical species and to generate chemical images. In this work, an organic-LED (OLED) display has been chosen as a light source. This allows high measurement resolution and miniaturisation of the system. A new developed driving method for the OLED display optimised for LAPS-based measurements is demonstrated. The new method enables to define modulation frequencies between 1 kHz and 16 kHz and hence, reduces the measurement time of a chemical image by a factor of 40 compared to the traditional addressing of an OLED display.}, language = {en} } @article{WagnerWernerMiyamotoetal.2012, author = {Wagner, Torsten and Werner, Frederik and Miyamoto, Ko-Ichiro and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Development and characterisation of a compact light-addressable potentiometric sensor (LAPS) based on the digital light processing (DLP) technology for flexible chemical imaging}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2010.12.003}, pages = {34 -- 39}, year = {2012}, abstract = {Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach to read out light-addressable potentiometric sensors (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device, which allows fast and flexible generation of light patterns. With the help of these light patterns, the sensor surface of the LAPS device can be addressed. The DLP approach has several advantages compared to conventional LAPS set-ups, e.g., the spot size and the shape of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of the measurement. In addition, the modulation frequency and intensity of the light beam are important parameters of the LAPS set-up. Within this work, the authors will discuss two different ways of light modulation by the DLP set-up, investigate the influence of different modulation frequencies and different light intensities as well as demonstrate the scanning capabilities of the new set-up by pH mapping on the sensor surface.}, language = {en} } @incollection{Vismann2012, author = {Vismann, Ulrich}, title = {Stahlbeton- und Spannbetonbau nach Eurocode 2}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_12}, pages = {601 -- 775}, year = {2012}, abstract = {Die bauaufsichtliche Einf{\"u}hrung der Eurocodes steht unmittelbar bevor. F{\"u}r den Bereich des Stahl- und Spannbetonbaus soll die Anwendung zum 1. Juli 2012 verbindlich sein, d. h. mit diesem Stichtag sollte nur noch der Eurocode 2 (DIN EN 1992-1-1, Ausgabe Januar 2011) mit seinem zugeh{\"o}rigen nationalen Anhang (DIN EN 1992-1-1/NA, Ausgabe Januar 2011) Verwendung finden, die DIN 1045-1 wird zur{\"u}ckgezogen. Bereits seit M{\"a}rz 2010 gilt eine {\"U}bergangsphase, ist der die Anwendung des Eurocodes alternativ zur DIN 1045-1 als bauaufsichtlich gleichwertige L{\"o}sung m{\"o}glich.}, language = {de} } @incollection{Vismann2012, author = {Vismann, Ulrich}, title = {Beton nach DIN 1045-2}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_11}, pages = {571 -- 600}, year = {2012}, language = {de} } @incollection{Feiser2012, author = {Feiser, Johannes}, title = {Geotechnik}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_17}, pages = {1221 -- 1332}, year = {2012}, abstract = {In der nationalen und der europ{\"a}ischen Normung werden die geotechnischen Aufgaben zwecks Mindestanforderungen an Baugrunduntersuchung, rechnerische Nachweise und {\"U}berwachung der Ausf{\"u}hrung in drei Klassen (Kategorien) eingeteilt. Sie richten sich nach der zu erwartenden Reaktion des Baugrundes, nach dem geotechnischen Schwierigkeitsgrad des Tragwerks und seiner Einfl{\"u}sse auf dieUmgebung.}, language = {de} } @incollection{Strohmeier2012, author = {Strohmeier, Andreas}, title = {Siedlungswasserwirtschaft}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_19}, pages = {1393 -- 1498}, year = {2012}, language = {de} } @incollection{Biener2012, author = {Biener, Ernst}, title = {Abfallwirtschaft}, series = {Wendehorst Bautechnische Zahlentafeln}, booktitle = {Wendehorst Bautechnische Zahlentafeln}, editor = {Vismann, Ulrich}, edition = {34}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2_20}, pages = {1499 -- 1540}, year = {2012}, language = {de} } @article{AggarwalDhimanKumaretal.2012, author = {Aggarwal, P. and Dhiman, S. and Kumar, G. and Scherer, Ulrich W. and Singla, M. L. and Srivastava, A.}, title = {Optical study of poly(ethyleneterephthalate) modified by different ionizing radiation dose}, series = {Indian Journal of Pure and Applied Physics}, volume = {50}, journal = {Indian Journal of Pure and Applied Physics}, number = {2}, issn = {0019-5596}, pages = {129 -- 132}, year = {2012}, abstract = {Thin films of poly(ethyleneterephthalate) [PET]were exposed to radiation dose ranging from 10 to 30 kGy by using gamma rays in the range 12.8-177.8 MGy using swift light ions of hydrogen. There was no effect of the radiation dose on the optical behaviour of PET as a result of exposure to radiation dose up to 30 kGy brought about by gamma rays but a significant decrease in the optical band gap values was observed when PET was exposed to swift light ions of hydrogen. The data obtained are discussed in terms of optical studies carried out on PET using swift heavy ions.}, language = {en} } @book{Schmitz2012, author = {Schmitz, G{\"u}nter}, title = {Elektronik im Kraftfahrzeug : Innovationen bei System und Komponenten ; mit 7 Tabellen / Hrsg.: Schmitz, G{\"u}nter}, publisher = {expert-Verl.}, address = {Renningen}, isbn = {978-3-8169-3110-2}, pages = {185 S. : Ill., graph. Darst.}, year = {2012}, language = {de} } @book{Vismann2012, author = {Vismann, Ulrich}, title = {Wendehorst Bautechnische Zahlentafeln / hrsg. von Ulrich Vismann in Verbindung mit dem DIN Deutsches Institut f{\"u}r Normung e.V. Herwig Baumgartner ...}, edition = {34., vollst. {\"u}berarb. und erw. Aufl.}, publisher = {Vieweg + Teubner}, address = {Wiesbaden}, isbn = {978-3-8348-0960-5}, doi = {10.1007/978-3-8348-8613-2}, pages = {1688 S. : graph. Darst.}, year = {2012}, language = {de} } @article{MiyamotoKanekoMatsuoetal.2012, author = {Miyamoto, Ko-ichiro and Kaneko, Kazumi and Matsuo, Akira and Wagner, Torsten and Kanoh, Shin{\´i}chiro and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Miniaturized chemical imaging sensor system using an OLED display panel}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2011.02.029}, pages = {82 -- 87}, year = {2012}, abstract = {The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current-voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.}, language = {en} } @article{KirchnerOberlaenderFriedrichetal.2012, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Friedrich, Peter and Berger, J{\"o}rg and Rysstad, Gunnar and Sch{\"o}ning, Michael Josef and Keusgen, Michael}, title = {Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2011.01.032}, pages = {60 -- 66}, year = {2012}, abstract = {A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(\%, v/v) in a H2O2 concentration range of 0\%, v/v to 8\%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes.}, language = {en} } @article{AtlasBrealeyDharetal.2012, author = {Atlas, Glen and Brealey, David and Dhar, Sunil and Dikta, Gerhard and Singer, Meryvn}, title = {Additional hemodynamic measurements with an esophageal Doppler monitor: a preliminary report of compliance, force, kinetic energy, and afterload in the clinical setting}, series = {Journal of clinical monitoring and computing}, journal = {Journal of clinical monitoring and computing}, number = {26}, publisher = {Springer Nature}, address = {London}, isbn = {1573-2614}, doi = {10.1007/s10877-012-9386-5}, pages = {473 -- 482}, year = {2012}, abstract = {The esophageal Doppler monitor (EDM) is a minimally-invasive hemodynamic device which evaluates both cardiac output (CO), and fluid status, by estimating stroke volume (SV) and calculating heart rate (HR). The measurement of these parameters is based upon a continuous and accurate approximation of distal thoracic aortic blood flow. Furthermore, the peak velocity (PV) and mean acceleration (MA), of aortic blood flow at this anatomic location, are also determined by the EDM. The purpose of this preliminary report is to examine additional clinical hemodynamic calculations of: compliance (C), kinetic energy (KE), force (F), and afterload (TSVRi). These data were derived using both velocity-based measurements, provided by the EDM, as well as other contemporaneous physiologic parameters. Data were obtained from anesthetized patients undergoing surgery or who were in a critical care unit. A graphical inspection of these measurements is presented and discussed with respect to each patient's clinical situation. When normalized to each of their initial values, F and KE both consistently demonstrated more discriminative power than either PV or MA. The EDM offers additional applications for hemodynamic monitoring. Further research regarding the accuracy, utility, and limitations of these parameters is therefore indicated.}, language = {en} } @incollection{HelsperDressler2012, author = {Helsper, Christoph and Dressler, J{\"o}rg}, title = {Partikelmesstechnik}, series = {Reinraumtechnik}, volume = {2012}, booktitle = {Reinraumtechnik}, editor = {Gail, Lothar and Gommel, Udo and Hortig, Hans-Peter}, edition = {3}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-642-19435-1}, doi = {10.1007/978-3-642-19435-1_3}, pages = {69 -- 95}, year = {2012}, abstract = {Der Schutz von Produkten vor der Kontamination durch Partikel gilt als eine zentrale Aufgabe der Reinraumtechnik. Da es dabei um Kontaminationseffekte weit unterhalb der visuellen Wahrnehmbarkeit geht, braucht es leistungsf{\"a}hige Verfahren, um die Messgr{\"o}ße „Partikelkontamination" {\"u}ber den gesamten Bereich, den Anwender fordern, pr{\"a}zise zu bestimmen. Neben der Partikelh{\"a}ufigkeit ist dabei die Gr{\"o}ße der Partikel, die sowohl das Transportverhalten wie auch die m{\"o}gliche Wirkung auf das Produkt beeinflusst, von entscheidender Bedeutung. Ferner kann es f{\"u}r die Ermittlung von Kontaminationsquellen von Interesse sein, die Form und die chemische Natur der Partikel zu bestimmen (z. B. textile Fasern, Metallabrieb, fl{\"u}ssige Tr{\"o}pfchen). Die Partikelh{\"a}ufigkeit wird {\"u}blicherweise als Konzentration, d. h. bezogen auf das analysierte Gasvolumen angegeben. Bei den in reinen Technologien {\"u}blichen niedrigen Konzentrationen dient als H{\"a}ufigkeitsmaß die Partikelanzahlkonzentration, also die Partikelanzahl pro Volumeneinheit des Tr{\"a}germediums.}, language = {de} } @article{Frings2012, author = {Frings, Michael}, title = {Immobilienfinanzierung und Verbraucherkredit : Das neue Verbraucherkreditrecht nach der Verbraucherkreditrichtlinie}, series = {NWB : Steuer- und Wirtschaftsrecht}, volume = {2012}, journal = {NWB : Steuer- und Wirtschaftsrecht}, number = {15}, publisher = {NWB-Verlag}, address = {Herne}, issn = {0028-3460}, pages = {1237 -- 1247}, year = {2012}, abstract = {Mit Gesetz vom 29.7.2009 (BGBl 2009 I S. 2355) hat der deutsche Gesetzgeber die EU-Verbraucherkreditrichtlinie 2008/48/EG vom 23.4.2008 NWB PAAAD-28762 in nationales Recht umgesetzt. In diesem Gesetz ist auch der Immobiliardarlehensvertrag neu geregelt worden. Auf diese besondere Kreditform sind grds. die Vorschriften zum Verbraucherkredit anzuwenden, so dass der Darlehensgeber auch im Fall einer Immobilienfinanzierung zu vorvertraglicher Information des Verbrauchers verpflichtet ist. Beim finanzierten Immobilienerwerb werden Ver{\"a}ußerer und kreditgebende Bank h{\"a}ufig in Abstimmung und Zusammenarbeit t{\"a}tig, so dass f{\"u}r die Bank besondere Aufkl{\"a}rungspflichten gegen{\"u}ber dem Verbraucher entstehen. Im Fall der Verletzung dieser Pflichten drohen ihr Schadensersatzanspr{\"u}che oder ein Widerrufsrecht des Verbrauchers.}, language = {de} } @article{Timme2012, author = {Timme, Michael}, title = {Die Reichweite der "werdenden" Wohnungseigent{\"u}mergemeinschaft gegen{\"u}ber dem Zweiterwerb}, series = {Monatsschrift f{\"u}r Deutsches Recht : MdR}, volume = {2012}, journal = {Monatsschrift f{\"u}r Deutsches Recht : MdR}, number = {18}, publisher = {Verlag Dr. Otto Schmidt}, address = {K{\"o}ln}, issn = {0340-1812}, doi = {10.9785/ovs-mdtr-2012-1069}, pages = {1068 -- 1071}, year = {2012}, abstract = {Mit einer aktuellen Entscheidung hat der BGH, Urt. v. 11.5.2012 - V ZR 196/11, MDR 2012, 958 seine Rechtsprechung v. 5.6.2008 - V ZB 85/07 zur Entstehungsphase einer Wohnungseigent{\"u}mergemeinschaft fortgef{\"u}hrt. In dieser Entscheidung sieht der BGH die Erwerber von Wohnungseigentum als Kostenschuldner gem. \S 16 Abs. 2 WEG an, obwohl diese noch nicht im Grundbuch eingetragen sind. Eine andere Rechtslage besteht beim sog. Zweiterwerb. Die Abgrenzung von Erstund Zweierwerb ist aufgrund der v{\"o}llig unterschiedlichen Rechtsfolgen f{\"u}r die Praxis von großer Bedeutung.}, language = {de} } @article{SchneiderSchneider2012, author = {Schneider, Bettina and Schneider, Wilhelm}, title = {Grundlagen der Unternehmensbesteuerung}, series = {Das Wirtschaftsstudium : wisu ; Zeitschrift f{\"u}r Ausbildung, Examen, Berufseinstieg und Fortbildung}, volume = {41}, journal = {Das Wirtschaftsstudium : wisu ; Zeitschrift f{\"u}r Ausbildung, Examen, Berufseinstieg und Fortbildung}, number = {10}, publisher = {Lange}, address = {D{\"u}sseldorf}, issn = {0340-3084}, pages = {1312 -- 1318}, year = {2012}, language = {de} } @article{IkenKirsanovLeginetal.2012, author = {Iken, Heiko and Kirsanov, D. and Legin, A. and Sch{\"o}ning, Michael Josef}, title = {Novel Thin-Film Polymeric Materials for the Detection of Heavy Metals}, series = {Procedia Engineering}, journal = {Procedia Engineering}, number = {47}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2012.09.148}, pages = {322 -- 325}, year = {2012}, abstract = {A variety of transition metals, e.g., copper, zinc, cadmium, lead, etc. are widely used in industry as components for wires, coatings, alloys, batteries, paints and so on. The inevitable presence of transition metals in industrial processes implies the ambition of developing a proper analytical technique for their adequate monitoring. Most of these elements, especially lead and cadmium, are acutely toxic for biological organisms. Quantitative determination of these metals at low activity levels in different environmental and industrial samples is therefore a vital task. A promising approach to achieve an at-side or on-line monitoring on a miniaturized and cost efficient way is the combination of a common potentiometric sensor array with heavy metal-sensitive thin-film materials, like chalcogenide glasses and polymeric materials, respectively.}, language = {en} } @article{MiyamotoIchimuraWagneretal.2012, author = {Miyamoto, K. and Ichimura, H. and Wagner, Torsten and Yoshinobu, T. and Sch{\"o}ning, Michael Josef}, title = {Chemical Imaging of ion Diffusion in a Microfluidic Channel}, series = {Procedia Engineering}, journal = {Procedia Engineering}, number = {47}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2012.09.289}, pages = {886 -- 889}, year = {2012}, abstract = {The chemical imaging sensor is a chemical sensor which is capable of visualizing the spatial distribution of chemical species in sample solution. In this study, a novel measurement system based on the chemical imaging sensor was developed to observe the inside of a Y-shaped microfluidic channel while injecting two sample solutions from two branches. From the collected chemical images, it was clearly observed that the injected solutions formed laminar flows in the microfluidic channel. In addition, ion diffusion across the laminar flows was observed. This label-free method can acquire quantitative data of ion distribution and diffusion in microfluidic devices, which can be used to determine the diffusion coefficients, and therefore, the molecular weights of chemical species in the sample solution.}, language = {en} } @article{WagnerShigiaharaMiyamotoetal.2012, author = {Wagner, Torsten and Shigiahara, N. and Miyamoto, K. and Suzurikawa, J. and Finger, F. and Sch{\"o}ning, Michael Josef and Yoshinobu, T.}, title = {Light-addressable Potentiometric Sensors and Light-addressable Electrodes as a Combined Sensor-and-manipulator Microsystem with High Flexibility}, series = {Procedia Engineering}, journal = {Procedia Engineering}, number = {47}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2012.09.290}, pages = {890 -- 893}, year = {2012}, abstract = {This work describes the novel combination of the light-addressable electrode (LAE) and the light-addressable potentiometric sensor (LAPS) into a microsystem set-up. Both the LAE as well as the LAPS shares the principle of addressing the active spot by means of a light beam. This enables both systems to manipulate resp. to detect an analyte with a high spatial resolution. Hence, combining both principles into a single set-up enables the active stimulation e.g., by means of electrolysis and a simultaneous observation e.g., the response of an entrapped biological cell by detection of extracellular pH changes. The work will describe the principles of both technologies and the necessary steps to integrate them into a single set-up. Furthermore, examples of application and operation of such systems will be presented.}, language = {en} }