@inproceedings{JabbariBhattaraiAndingetal.2017, author = {Jabbari, Medisa and Bhattarai, Aroj and Anding, Ralf and Staat, Manfred}, title = {Biomechanical simulation of different prosthetic meshes for repairing uterine/vaginal vault prolapse}, series = {2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West}, booktitle = {2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West}, editor = {Erni, Daniel and Fischerauer, Alice and Himmel, J{\"o}rg and Seeger, Thomas and Thelen, Klaus}, publisher = {Universit{\"a}t Duisburg-Essen}, address = {Duisburg}, organization = {MedTech Symposium}, isbn = {978-3-9814801-9-1}, doi = {10.17185/duepublico/43984}, pages = {118 -- 119}, year = {2017}, language = {en} } @article{KotliarSvetlovaSourjikovetal.2004, author = {Kotliar, Konstantin and Svetlova, O. V. and Sourjikov, A. V. and Zaseeva, M. V.}, title = {Biomechanical peculiarities of aqueous humor production system and outflow regulation system / Svetlova, O. V. ; Sourjikov, A. V. ; Kotliar, K. E. ; Zaseeva, M. V. ; Shukhaev, S. V. ; Koshitz, I. N.}, series = {Glaukoma (2004)}, journal = {Glaukoma (2004)}, publisher = {-}, pages = {66 -- 76}, year = {2004}, language = {en} } @inproceedings{KahmannUschokWegmannetal.2018, author = {Kahmann, Stephanie Lucina and Uschok, Stephan and Wegmann, Kilian and M{\"u}ller, Lars-P. and Staat, Manfred}, title = {Biomechanical multibody model with refined kinematics of the elbow}, series = {6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK}, booktitle = {6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK}, pages = {11 Seiten}, year = {2018}, abstract = {The overall objective of this study is to develop a new external fixator, which closely maps the native kinematics of the elbow to decrease the joint force resulting in reduced rehabilitation time and pain. An experimental setup was designed to determine the native kinematics of the elbow during flexion of cadaveric arms. As a preliminary study, data from literature was used to modify a published biomechanical model for the calculation of the joint and muscle forces. They were compared to the original model and the effect of the kinematic refinement was evaluated. Furthermore, the obtained muscle forces were determined in order to apply them in the experimental setup. The joint forces in the modified model differed slightly from the forces in the original model. The muscle force curves changed particularly for small flexion angles but their magnitude for larger angles was consistent.}, language = {en} } @article{KotliarLanzl2002, author = {Kotliar, Konstantin and Lanzl, I. M.}, title = {Biomechanical modeling of the aqueous humor outflow after non-penetrating glaucoma filtration surgery in the human eye}, series = {Acta of bioengineering and biomechanics}, volume = {Vol. 4}, journal = {Acta of bioengineering and biomechanics}, number = {Suppl. 1}, issn = {1509-409X}, pages = {728 -- 729}, year = {2002}, language = {de} } @article{HorbachStaatPerezVianaetal.2020, author = {Horbach, Andreas and Staat, Manfred and Perez-Viana, Daniel and Simmen, Hans-Peter and Neuhaus, Valentin and Pape, Hans-Christoph and Prescher, Andreas and Ciritsis, Bernhard}, title = {Biomechanical in vitro examination of a standardized low-volume tubular femoroplasty}, series = {Clinical Biomechanics}, volume = {80}, journal = {Clinical Biomechanics}, number = {Art. 105104}, publisher = {Elsevier}, address = {Amsterdam}, doi = {10.1016/j.clinbiomech.2020.105104}, year = {2020}, abstract = {Background Osteoporosis is associated with the risk of fractures near the hip. Age and comorbidities increase the perioperative risk. Due to the ageing population, fracture of the proximal femur also proves to be a socio-economic problem. Preventive surgical measures have hardly been used so far. Methods 10 pairs of human femora from fresh cadavers were divided into control and low-volume femoroplasty groups and subjected to a Hayes fall-loading fracture test. The results of the respective localization and classification of the fracture site, the Singh index determined by computed tomography (CT) examination and the parameters in terms of fracture force, work to fracture and stiffness were evaluated statistically and with the finite element method. In addition, a finite element parametric study with different position angles and variants of the tubular geometry of the femoroplasty was performed. Findings Compared to the control group, the work to fracture could be increased by 33.2\%. The fracture force increased by 19.9\%. The used technique and instrumentation proved to be standardized and reproducible with an average poly(methyl methacrylate) volume of 10.5 ml. The parametric study showed the best results for the selected angle and geometry. Interpretation The cadaver studies demonstrated the biomechanical efficacy of the low-volume tubular femoroplasty. The numerical calculations confirmed the optimal choice of positioning as well as the inner and outer diameter of the tube in this setting. The standardized minimally invasive technique with the instruments developed for it could be used in further comparative studies to confirm the measured biomechanical results.}, language = {en} } @article{KotliarKoshitzSvetlowaetal.2005, author = {Kotliar, Konstantin and Koshitz, I. N. and Svetlowa, O. V. and Makarov, F. N.}, title = {Biomechanical analysis of traditional and contemporary conceptions on pathogenesis of the primary open angle glaucoma / Koshitz, I. N. ; Svetlova, O. V. ; Kotliar, K. E. ; Makarov, F. N. ; Smolnikov, B. A.}, series = {Glaukoma (2005)}, journal = {Glaukoma (2005)}, publisher = {-}, pages = {41 -- 63}, year = {2005}, language = {en} } @phdthesis{Foeckler2016, author = {F{\"o}ckler, Nicole}, title = {Biomarker zur Prognose von Fr{\"u}hgeburten : ein biomedizintechnischer Ansatz}, publisher = {Deutsche Zentralbibliothek f{\"u}r Medizin}, address = {K{\"o}ln}, doi = {10.4126/FRL01-006401575}, pages = {VII, 117 S.}, year = {2016}, language = {de} } @book{ArtmannTemizArtmannZhubanovaetal.2018, author = {Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l and Zhubanova, Azhar A. and Digel, Ilya}, title = {Biological, physical and technical basics of cell engineering}, editor = {Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l and Zhubanova, Azhar A. and Digel, Ilya}, publisher = {Springer}, address = {Singapore}, isbn = {978-981-10-7903-0}, pages = {xxiv, 481 Seiten ; Illustrationen, Diagramme}, year = {2018}, language = {en} } @article{MaggakisKelemenBorkKayseretal.2003, author = {Maggakis-Kelemen, C. and Bork, M. and Kayser, Peter and Biselli, Manfred and Artmann, Gerhard}, title = {Biological and mechanical quality of red blood cells cultured from human umbilical cord blood stem cells}, series = {Medical and biological engineering and computing. 41 (2003), H. 3}, journal = {Medical and biological engineering and computing. 41 (2003), H. 3}, isbn = {0140-0118}, pages = {350 -- 356}, year = {2003}, language = {en} } @book{Artmann2008, author = {Artmann, Gerhard}, title = {Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.)}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-540-75408-4}, year = {2008}, language = {en} } @incollection{MansurovJandosovChenchiketal.2020, author = {Mansurov, Zulkhair A. and Jandosov, Jakpar and Chenchik, D. and Azat, Seitkhan and Savitskaya, Irina S. and Kistaubaeva, Aida and Akimbekov, Nuraly S. and Digel, Ilya and Zhubanova, Azhar Achmet}, title = {Biocomposite Materials Based on Carbonized Rice Husk in Biomedicine and Environmental Applications}, series = {Carbon Nanomaterials in Biomedicine and the Environment}, booktitle = {Carbon Nanomaterials in Biomedicine and the Environment}, publisher = {Jenny Stanford Publishing Pte. Ltd.}, address = {Singapore}, isbn = {978-981-4800-27-3}, doi = {10.1201/9780429428647-2}, pages = {3 -- 32}, year = {2020}, abstract = {This chapter describes the prospects for biomedical and environmental engineering applications of heterogeneous materials based on nanostructured carbonized rice husk. Efforts in engineering enzymology are focused on the following directions: development and optimization of immobilization methods leading to novel biotechnological and biomedical applications; construction of biocomposite materials based on individual enzymes, multi-enzyme complexes and whole cells, targeted on realization of specific industrial processes. Molecular biological and biochemical studies on cell adhesion focus predominantly on identification, isolation and structural analysis of attachment-responsible biological molecules and their genetic determinants. The chapter provides a short overview of applications of the biocomposite materials based of nanostructured carbonized adsorbents. It emphasizes that further studies and better understanding of the interactions between CNS and microbial cells are necessary. The future use of living cells as biocatalysts, especially in the environmental field, needs more systematic investigations of the microbial adsorption phenomenon.}, language = {en} } @article{AkimbekovDigelTastambeketal.2013, author = {Akimbekov, Nuraly S. and Digel, Ilya and Tastambek, K. T. and Zhubanova, A. A.}, title = {Biocompatibility of carbonized rice husk with a rat heart cells line H9c2}, series = {Experimental Biology}, volume = {59}, journal = {Experimental Biology}, number = {3/1}, issn = {1563-0218}, pages = {23 -- 25}, year = {2013}, language = {en} } @article{UysalCreutzFiratetal.2022, author = {Uysal, Karya and Creutz, Till and Firat, Ipek Seda and Artmann, Gerhard and Teusch, Nicole and Temiz Artmann, Ayseg{\"u}l}, title = {Bio-functionalized ultra-thin, large-area and waterproof silicone membranes for biomechanical cellular loading and compliance experiments}, series = {Polymers}, volume = {14}, journal = {Polymers}, number = {11}, publisher = {MDPI}, address = {Basel}, issn = {2073-4360}, pages = {2213}, year = {2022}, abstract = {Biocompatibility, flexibility and durability make polydimethylsiloxane (PDMS) membranes top candidates in biomedical applications. CellDrum technology uses large area, <10 µm thin membranes as mechanical stress sensors of thin cell layers. For this to be successful, the properties (thickness, temperature, dust, wrinkles, etc.) must be precisely controlled. The following parameters of membrane fabrication by means of the Floating-on-Water (FoW) method were investigated: (1) PDMS volume, (2) ambient temperature, (3) membrane deflection and (4) membrane mechanical compliance. Significant differences were found between all PDMS volumes and thicknesses tested (p < 0.01). They also differed from the calculated values. At room temperatures between 22 and 26 °C, significant differences in average thickness values were found, as well as a continuous decrease in thicknesses within a 4 °C temperature elevation. No correlation was found between the membrane thickness groups (between 3-4 µm) in terms of deflection and compliance. We successfully present a fabrication method for thin bio-functionalized membranes in conjunction with a four-step quality management system. The results highlight the importance of tight regulation of production parameters through quality control. The use of membranes described here could also become the basis for material testing on thin, viscous layers such as polymers, dyes and adhesives, which goes far beyond biological applications.}, language = {en} } @article{MansurovDigelBiisenbaevetal.2012, author = {Mansurov, Z. and Digel, Ilya and Biisenbaev, M. and Savistkaya, I. and Kistaubaeva, A. and Akimbekov, Nuraly S. and Zhubanova, A.}, title = {Bio-composite material on the basis of carbonized rice husk in biomedicine and environmental applications}, series = {Eurasian Chemico-Technological Journal}, volume = {14}, journal = {Eurasian Chemico-Technological Journal}, number = {2}, publisher = {Institute of Combustion Problems}, address = {Almaty}, issn = {2522-4867}, doi = {10.18321/ectj105}, pages = {115 -- 131}, year = {2012}, language = {en} } @misc{StaatHorbachGatzweiler2019, author = {Staat, Manfred and Horbach, Andreas and Gatzweiler, Karl-Heinz}, title = {Biaxiales Materialpr{\"u}fsystem und Verfahren zu dessen Anwendung}, year = {2019}, abstract = {System und Verfahren zur Durchf{\"u}hrung von Messungen biaxialer und kreuzf{\"o}rmiger Zugversuche, wobei ein Weg oder eine Kraft auf eine Materialprobe {\"u}ber mindestens zwei Nadelarme mit Nadeln geleitet wird, die in einem Geh{\"a}use gelagert sind, wobei die Arme und/oder Nadelarme f{\"u}r eine ungehinderte Querkontraktion bei gleichm{\"a}ßiger Lasteinleitung um eine Achse drehbar gelagert und seitlich auslenkbar sind.}, language = {de} } @incollection{LanzlSeidovaDuehringetal.2009, author = {Lanzl, I. and Seidova, S.-F. and D{\"u}hring, C. von and Kotliar, Konstantin}, title = {Befunde der dynamischen Gef{\"a}ßanalyse am Auge bei Gesunden und Glaukom-Patienten mit praxisrelevanter Bedeutung}, series = {Mikrozirkulation beim Glaukom}, booktitle = {Mikrozirkulation beim Glaukom}, editor = {Erb, Carl}, publisher = {Elsevier}, address = {Amsterdam}, pages = {33 -- 39}, year = {2009}, language = {de} } @incollection{StaatHeitzer2003, author = {Staat, Manfred and Heitzer, M.}, title = {Basis reduction technique for limit and shakedown problems}, series = {Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M.; Heitzer, M.}, booktitle = {Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M.; Heitzer, M.}, publisher = {John von Neumann Institute for Computing (NIC)}, address = {J{\"u}lich}, isbn = {3-00-010001-6}, url = {http://nbn-resolving.de/urn:nbn:de:0001-2018112115}, pages = {1 -- 55}, year = {2003}, language = {en} } @article{DigelTemizArtmannNishikawaetal.2005, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Nishikawa, K. and Cook, M.}, title = {Bactericidal effects of plasma-generated cluster ions}, series = {Medical and Biological Engineering and Computing. 43 (2005), H. 6}, journal = {Medical and Biological Engineering and Computing. 43 (2005), H. 6}, isbn = {1741-0444}, pages = {800 -- 807}, year = {2005}, language = {en} } @article{DigelAkimbekovRogachevetal.2023, author = {Digel, Ilya and Akimbekov, Nuraly S. and Rogachev, Evgeniy and Pogorelova, Natalia}, title = {Bacterial cellulose produced by Medusomyces gisevii on glucose and sucrose: biosynthesis and structural properties}, series = {Cellulose}, journal = {Cellulose}, publisher = {Springer Science + Business Media}, address = {Dordrecht}, issn = {1572-882X (Online)}, doi = {10.1007/s10570-023-05592-z}, pages = {15 Seiten}, year = {2023}, abstract = {In this work, the effects of carbon sources and culture media on the production and structural properties of bacterial cellulose (BC) synthesized by Medusomyces gisevii have been studied. The culture medium was composed of different initial concentrations of glucose or sucrose dissolved in 0.4\% extract of plain green tea. Parameters of the culture media (titratable acidity, substrate conversion degree etc.) were monitored daily for 20 days of cultivation. The BC pellicles produced on different carbon sources were characterized in terms of biomass yield, crystallinity and morphology by field emission scanning electron microscopy (FE-SEM), atomic force microscopy and X-ray diffraction. Our results showed that Medusomyces gisevii had higher BC yields in media with sugar concentrations close to 10 g L-1 after a 18-20 days incubation period. Glucose in general lead to a higher BC yield (173 g L-1) compared to sucrose (163.5 g L-1). The BC crystallinity degree and surface roughness were higher in the samples synthetized from sucrose. Obtained FE-SEM micrographs show that the BC pellicles synthesized in the sucrose media contained densely packed tangles of cellulose fibrils whereas the BC produced in the glucose media displayed rather linear geometry of the BC fibrils without noticeable aggregates.}, language = {en} } @article{PogorelovaRogachevDigeletal.2020, author = {Pogorelova, Natalia and Rogachev, Evgeniy and Digel, Ilya and Chernigova, Svetlana and Nardin, Dmitry}, title = {Bacterial Cellulose Nanocomposites: Morphology and Mechanical Properties}, series = {Materials}, volume = {13}, journal = {Materials}, number = {12}, publisher = {MDPI}, address = {Basel}, isbn = {1996-1944}, doi = {10.3390/ma13122849}, pages = {1 -- 16}, year = {2020}, abstract = {Bacterial cellulose (BC) is a promising material for biomedical applications due to its unique properties such as high mechanical strength and biocompatibility. This article describes the microbiological synthesis, modification, and characterization of the obtained BC-nanocomposites originating from symbiotic consortium Medusomyces gisevii. Two BC-modifications have been obtained: BC-Ag and BC-calcium phosphate (BC-Ca3(PO4)2). Structure and physicochemical properties of the BC and its modifications were investigated by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), atomic force microscopy (AFM), and infrared Fourier spectroscopy as well as by measurements of mechanical and water holding/absorbing capacities. Topographic analysis of the surface revealed multicomponent thick fibrils (150-160 nm in diameter and about 15 µm in length) constituted by 50-60 nm nanofibrils weaved into a left-hand helix. Distinctive features of Ca-phosphate-modified BC samples were (a) the presence of 500-700 nm entanglements and (b) inclusions of Ca3(PO4)2 crystals. The samples impregnated with Ag nanoparticles exhibited numerous roundish inclusions, about 110 nm in diameter. The boundaries between the organic and inorganic phases were very distinct in both cases. The Ag-modified samples also showed a prominent waving pattern in the packing of nanofibrils. The obtained BC gel films possessed water-holding capacity of about 62.35 g/g. However, the dried (to a constant mass) BC-films later exhibited a low water absorption capacity (3.82 g/g). It was found that decellularized BC samples had 2.4 times larger Young's modulus and 2.2 times greater tensile strength as compared to dehydrated native BC films. We presume that this was caused by molecular compaction of the BC structure.}, language = {en} }