@article{BlankeRegerDoeringetal.2021, author = {Blanke, Tobias and Reger, Vitali and D{\"o}ring, Bernd and G{\"o}ttsche, Joachim and Kuhnhenne, Markus}, title = {Koaxiale Stahlenergiepf{\"a}hle}, series = {Stahlbau}, volume = {90. 2021}, journal = {Stahlbau}, number = {6}, publisher = {Wiley}, address = {Weinheim}, pages = {417 -- 424}, year = {2021}, abstract = {Ein entscheidender Teil der Energiewende ist die W{\"a}rmewende im Geb{\"a}udesektor. Ein Schl{\"u}sselelement sind hier W{\"a}rmepumpen. Diese ben{\"o}tigen eine W{\"a}rmequelle, der sie Energie entziehen k{\"o}nnen, um sie auf ein h{\"o}heres Temperaturniveau zu transformieren. Diese W{\"a}rmequelle kann bspw. das Erdreich sein, dessen W{\"a}rme durch Erdsonden erschlossen werden kann. In diesem Beitrag werden in Stahlpf{\"a}hle integrierte Koaxialsonden mit dem Stand der Technik von Erdsonden gleichen Durchmessers bez{\"u}glich ihrer thermischen Leistungsmerkmale verglichen. Die Stahlenergiepf{\"a}hle bieten neben der W{\"a}rmegewinnung weitere Vorteile, da sie auch eine statische Funktion {\"u}bernehmen und r{\"u}ckstandsfrei zur{\"u}ckgebaut werden k{\"o}nnen. Es werden analytische und numerische Berechnungen vorgestellt, um die thermischen Potenziale beider Systeme zu vergleichen. Außerdem wird ein Testaufbau gezeigt, bei dem Stahlenergiepf{\"a}hle in zwei verschiedenen L{\"a}ngen mit vorhandenen g{\"a}ngigen Erdsonden verglichen werden k{\"o}nnen. Die Berechnungen zeigen einen deutlichen thermischen Mehrertrag zwischen 26 \% und 148 \% der Stahlenergiepf{\"a}hle gegen{\"u}ber dem Stand der Technik abh{\"a}ngig vom Erdreich. Die Messergebnisse zeigen einen thermischen Mehrertrag von {\"u}ber 100 \%. Es l{\"a}sst sich also signifikante Erdsondenl{\"a}nge einsparen. Dabei ist zu beachten, dass sich damit der thermisch genutzte Bereich des Erdreichs reduziert, wodurch die thermische Regeneration und/oder das Langzeitverhalten des Erdreichs an Bedeutung gewinnt.}, language = {de} } @article{BlassUibel2009, author = {Blaß, Hans Joachim and Uibel, Thomas}, title = {Bemessungsvorschl{\"a}ge f{\"u}r Verbindungsmittel in Brettsperrholz}, series = {Bauen mit Holz}, volume = {111}, journal = {Bauen mit Holz}, number = {2}, publisher = {Rudolf M{\"u}ller}, address = {K{\"o}ln}, issn = {0005-6545}, pages = {46 -- 53}, year = {2009}, language = {de} } @article{BleckenHolthausSellheier2011, author = {Blecken, Udo and Holthaus-Sellheier, Ursula}, title = {Quantitative Prognoseverfahren f{\"u}r den B{\"u}roimmobilienmarkt, Tl.1}, series = {GuG : Grundst{\"u}cksmarkt und Grundst{\"u}ckswert}, volume = {21}, journal = {GuG : Grundst{\"u}cksmarkt und Grundst{\"u}ckswert}, number = {1}, publisher = {Werner}, address = {K{\"o}ln}, isbn = {0938-0175}, pages = {30 -- 39}, year = {2011}, language = {de} } @article{BleckenHolthausSellheier2011, author = {Blecken, Udo and Holthaus-Sellheier, Ursula}, title = {Quantitative Prognoseverfahren f{\"u}r den B{\"u}roimmobilienmarkt. Tl. 2}, series = {GuG : Grundst{\"u}cksmarkt und Grundst{\"u}ckswert}, volume = {21}, journal = {GuG : Grundst{\"u}cksmarkt und Grundst{\"u}ckswert}, number = {3}, publisher = {Werner}, address = {K{\"o}ln}, isbn = {0938-0175}, pages = {156 -- 163}, year = {2011}, language = {de} } @article{BleckenHolthausSellheier2012, author = {Blecken, Udo and Holthaus-Sellheier, Ursula}, title = {Quantitative Prognoseverfahren f{\"u}r Mietpreise von Bueroimmobilien am Beispiel D{\"u}sseldorf}, series = {GuG : Grundst{\"u}cksmarkt und Grundst{\"u}ckswert}, volume = {23}, journal = {GuG : Grundst{\"u}cksmarkt und Grundst{\"u}ckswert}, number = {1}, publisher = {Werner}, address = {K{\"o}ln}, issn = {0938-0175}, pages = {12 -- 21}, year = {2012}, language = {de} } @article{Bung2013, author = {Bung, Daniel B.}, title = {Non-intrusive detection of air-water surface roughness in self-aerated chute flows}, series = {Journal of hydraulic research}, volume = {Vol. 51}, journal = {Journal of hydraulic research}, number = {Iss. 3}, publisher = {Taylor \& Francis}, address = {London}, issn = {1814-2079 (E-Journal); 0022-1686 (Print)}, pages = {322 -- 329}, year = {2013}, language = {en} } @article{Bung2011, author = {Bung, Daniel B.}, title = {Developing flow in skimming flow regime on embankment stepped spillways}, series = {Journal of hydraulic research}, volume = {Vol. 49}, journal = {Journal of hydraulic research}, number = {Iss. 5}, publisher = {Taylor \& Francis}, address = {London}, issn = {1814-2079 (E-Journal); 0022-1686 (Print)}, pages = {639 -- 648}, year = {2011}, language = {en} } @article{Bung2011, author = {Bung, Daniel B.}, title = {Fließcharakteristik und Sauerstoffeintrag bei selbstbel{\"u}fteten Gerinnestr{\"o}mungen auf Kaskaden mit gem{\"a}ßigter Neigung}, series = {{\"O}sterreichische Wasser- und Abfallwirtschaft}, volume = {Vol. 63}, journal = {{\"O}sterreichische Wasser- und Abfallwirtschaft}, number = {Iss. 3-4}, publisher = {Springer}, address = {Berlin}, issn = {1613-7566 (E-Journal); 0945-358X (Print)}, pages = {76 -- 81}, year = {2011}, language = {de} } @article{BungCrookstonValero2020, author = {Bung, Daniel B. and Crookston, Brian M. and Valero, Daniel}, title = {Turbulent free-surface monitoring with an RGB-D sensor: the hydraulic jump case}, series = {Journal of Hydraulic Research}, journal = {Journal of Hydraulic Research}, publisher = {Taylor \& Francis}, address = {London}, issn = {1814-2079}, doi = {10.1080/00221686.2020.1844810}, year = {2020}, language = {en} } @article{BungValero2018, author = {Bung, Daniel B. and Valero, Daniel}, title = {Re-aeration on stepped spillways with special consideration of entrained and entrapped air}, series = {Geosciences}, volume = {8}, journal = {Geosciences}, number = {9}, publisher = {MDPI}, address = {Basel}, issn = {2076-3263}, pages = {Article number 333}, year = {2018}, abstract = {As with most high-velocity free-surface flows, stepped spillway flows become self-aerated when the drop height exceeds a critical value. Due to the step-induced macro-roughness, the flow field becomes more turbulent than on a similar smooth-invert chute. For this reason, cascades are oftentimes used as re-aeration structures in wastewater treatment. However, for stepped spillways as flood release structures downstream of deoxygenated reservoirs, gas transfer is also of crucial significance to meet ecological requirements. Prediction of mass transfer velocities becomes challenging, as the flow regime differs from typical previously studied flow conditions. In this paper, detailed air-water flow measurements are conducted on stepped spillway models with different geometry, with the aim to estimate the specific air-water interface. Re-aeration performances are determined by applying the absorption method. In contrast to earlier studies, the aerated water body is considered a continuous mixture up to a level where 75\% air concentration is reached. Above this level, a homogenous surface wave field is considered, which is found to significantly affect the total air-water interface available for mass transfer. Geometrical characteristics of these surface waves are obtained from high-speed camera investigations. The results show that both the mean air concentration and the mean flow velocity have influence on the mass transfer. Finally, an empirical relationship for the mass transfer on stepped spillway models is proposed.}, language = {en} } @article{BungValero2016, author = {Bung, Daniel B. and Valero, Daniel}, title = {Optical flow estimation in aerated flows}, series = {Journal of Hydraulic Research}, volume = {54}, journal = {Journal of Hydraulic Research}, number = {5}, publisher = {Taylor \& Francis}, address = {London}, doi = {10.1080/00221686.2016.1173600}, pages = {575 -- 580}, year = {2016}, abstract = {Optical flow estimation is known from Computer Vision where it is used to determine obstacle movements through a sequence of images following an assumption of brightness conservation. This paper presents the first study on application of the optical flow method to aerated stepped spillway flows. For this purpose, the flow is captured with a high-speed camera and illuminated with a synchronized LED light source. The flow velocities, obtained using a basic Horn-Schunck method for estimation of the optical flow coupled with an image pyramid multi-resolution approach for image filtering, compare well with data from intrusive conductivity probe measurements. Application of the Horn-Schunck method yields densely populated flow field data sets with velocity information for every pixel. It is found that the image pyramid approach has the most significant effect on the accuracy compared to other image processing techniques. However, the final results show some dependency on the pixel intensity distribution, with better accuracy found for grey values between 100 and 150.}, language = {en} } @article{BungErpicumTullis2020, author = {Bung, Daniel Bernhard and Erpicum, S{\´e}bastien and Tullis, Blanke P.}, title = {Advances in hydraulic structures engineering}, series = {Journal of Hydraulic Engineering}, volume = {147}, journal = {Journal of Hydraulic Engineering}, number = {1}, publisher = {ASCE}, address = {Reston, Va.}, issn = {0733-9429 (Druckausgabe)}, doi = {10.1061/(ASCE)HY.1943-7900.0001851}, pages = {1 Seite}, year = {2020}, language = {en} } @article{CheenakulaGriebelMontagetal.2023, author = {Cheenakula, Dheeraja and Griebel, Kai and Montag, David and Gr{\"o}mping, Markus}, title = {Concept development of a mainstream deammonification and comparison with conventional process in terms of energy, performance and economical construction perspectives}, series = {Frontiers in Microbiology}, volume = {14}, journal = {Frontiers in Microbiology}, number = {11155235}, editor = {Huang, Xiaowu}, publisher = {Frontiers}, issn = {1664-302X}, doi = {10.3389/fmicb.2023.1155235}, pages = {1 -- 15}, year = {2023}, abstract = {Deammonification for nitrogen removal in municipal wastewater in temperate and cold climate zones is currently limited to the side stream of municipal wastewater treatment plants (MWWTP). This study developed a conceptual model of a mainstream deammonification plant, designed for 30,000 P.E., considering possible solutions corresponding to the challenging mainstream conditions in Germany. In addition, the energy-saving potential, nitrogen elimination performance and construction-related costs of mainstream deammonification were compared to a conventional plant model, having a single-stage activated sludge process with upstream denitrification. The results revealed that an additional treatment step by combining chemical precipitation and ultra-fine screening is advantageous prior the mainstream deammonification. Hereby chemical oxygen demand (COD) can be reduced by 80\% so that the COD:N ratio can be reduced from 12 to 2.5. Laboratory experiments testing mainstream conditions of temperature (8-20°C), pH (6-9) and COD:N ratio (1-6) showed an achievable volumetric nitrogen removal rate (VNRR) of at least 50 gN/(m3∙d) for various deammonifying sludges from side stream deammonification systems in the state of North Rhine-Westphalia, Germany, where m3 denotes reactor volume. Assuming a retained Norganic content of 0.0035 kgNorg./(P.E.∙d) from the daily loads of N at carbon removal stage and a VNRR of 50 gN/(m3∙d) under mainstream conditions, a resident-specific reactor volume of 0.115 m3/(P.E.) is required for mainstream deammonification. This is in the same order of magnitude as the conventional activated sludge process, i.e., 0.173 m3/(P.E.) for an MWWTP of size class of 4. The conventional plant model yielded a total specific electricity demand of 35 kWh/(P.E.∙a) for the operation of the whole MWWTP and an energy recovery potential of 15.8 kWh/(P.E.∙a) through anaerobic digestion. In contrast, the developed mainstream deammonification model plant would require only a 21.5 kWh/(P.E.∙a) energy demand and result in 24 kWh/(P.E.∙a) energy recovery potential, enabling the mainstream deammonification model plant to be self-sufficient. The retrofitting costs for the implementation of mainstream deammonification in existing conventional MWWTPs are nearly negligible as the existing units like activated sludge reactors, aerators and monitoring technology are reusable. However, the mainstream deammonification must meet the performance requirement of VNRR of about 50 gN/(m3∙d) in this case.}, language = {en} } @article{CheenakulaHoffstadtKrafftetal.2022, author = {Cheenakula, Dheeraja and Hoffstadt, Kevin and Krafft, Simone and Reinecke, Diana and Klose, Holger and Kuperjans, Isabel and Gr{\"o}mping, Markus}, title = {Anaerobic digestion of algal-bacterial biomass of an Algal Turf Scrubber system}, series = {Biomass Conversion and Biorefinery}, volume = {13}, journal = {Biomass Conversion and Biorefinery}, publisher = {Springer}, address = {Berlin}, issn = {2190-6823}, doi = {10.1007/s13399-022-03236-z}, pages = {15 Seiten}, year = {2022}, abstract = {This study investigated the anaerobic digestion of an algal-bacterial biofilm grown in artificial wastewater in an Algal Turf Scrubber (ATS). The ATS system was located in a greenhouse (50°54′19ʺN, 6°24′55ʺE, Germany) and was exposed to seasonal conditions during the experiment period. The methane (CH4) potential of untreated algal-bacterial biofilm (UAB) and thermally pretreated biofilm (PAB) using different microbial inocula was determined by anaerobic batch fermentation. Methane productivity of UAB differed significantly between microbial inocula of digested wastepaper, a mixture of manure and maize silage, anaerobic sewage sludge, and percolated green waste. UAB using sewage sludge as inoculum showed the highest methane productivity. The share of methane in biogas was dependent on inoculum. Using PAB, a strong positive impact on methane productivity was identified for the digested wastepaper (116.4\%) and a mixture of manure and maize silage (107.4\%) inocula. By contrast, the methane yield was significantly reduced for the digested anaerobic sewage sludge (50.6\%) and percolated green waste (43.5\%) inocula. To further evaluate the potential of algal-bacterial biofilm for biogas production in wastewater treatment and biogas plants in a circular bioeconomy, scale-up calculations were conducted. It was found that a 0.116 km2 ATS would be required in an average municipal wastewater treatment plant which can be viewed as problematic in terms of space consumption. However, a substantial amount of energy surplus (4.7-12.5 MWh a-1) can be gained through the addition of algal-bacterial biomass to the anaerobic digester of a municipal wastewater treatment plant. Wastewater treatment and subsequent energy production through algae show dominancy over conventional technologies.}, language = {en} } @article{CheenakulaPaulsenOttetal.2023, author = {Cheenakula, Dheeraja and Paulsen, Svea and Ott, Fabian and Gr{\"o}mping, Markus}, title = {Operational window of a deammonifying sludge for mainstream application in a municipal wastewater treatment plant}, series = {Water and Environment Journal}, journal = {Water and Environment Journal}, number = {Early View}, publisher = {Wiley}, address = {Chichester}, issn = {1747-6593}, doi = {10.1111/wej.12898}, pages = {1 -- 12}, year = {2023}, abstract = {The present work aimed to study the mainstream feasibility of the deammonifying sludge of side stream of municipal wastewater treatment plant (MWWTP) in Kaster, Germany. For this purpose, the deammonifying sludge available at the side stream was investigated for nitrogen (N) removal with respect to the operational factors temperature (15-30°C), pH value (6.0-8.0) and chemical oxygen demand (COD)/N ratio (≤1.5-6.0). The highest and lowest N-removal rates of 0.13 and 0.045 kg/(m³ d) are achieved at 30 and 15°C, respectively. Different conditions of pH and COD/N ratios in the SBRs of Partial nitritation/anammox (PN/A) significantly influenced both the metabolic processes and associated N-removal rates. The scientific insights gained from the current work signifies the possibility of mainstream PN/A at WWTPs. The current study forms a solid basis of operational window for the upcoming semi-technical trails to be conducted prior to the full-scale mainstream PN/A at WWTP Kaster and WWTPs globally.}, language = {en} } @article{DemnyHebel2014, author = {Demny, Andreas and Hebel, Christoph}, title = {Rechnergest{\"u}tzte Ermittlung der Verbindungsfunktionsstufen und der verbindungsbezogenen Angebotsqualit{\"a}t nach den Richtlinien f{\"u}r integrierte Netzgestaltung nach RIN 2008}, series = {Straßenverkehrstechnik : Organ der Forschungsgesellschaft f{\"u}r Straßen- und Verkehrswesen, der Bundesvereinigung der Straßenbau- und Verkehrsingenieure und der {\"O}sterreichischen Forschungsgesellschaft Straße und Verkehr ; Zeitschrift f{\"u}r Verkehrsplanung, Verkehrsmanagement, Verkehrssicherheit, Verkehrstechnik}, volume = {Jg. 58}, journal = {Straßenverkehrstechnik : Organ der Forschungsgesellschaft f{\"u}r Straßen- und Verkehrswesen, der Bundesvereinigung der Straßenbau- und Verkehrsingenieure und der {\"O}sterreichischen Forschungsgesellschaft Straße und Verkehr ; Zeitschrift f{\"u}r Verkehrsplanung, Verkehrsmanagement, Verkehrssicherheit, Verkehrstechnik}, number = {H. 12}, publisher = {Kirschbaum Verlag}, address = {Bonn}, issn = {0039-2219}, pages = {811 -- 820}, year = {2014}, language = {de} } @article{Dienst1971, author = {Dienst, Karl-Jakob}, title = {Bewegungsgruppen projektiv-metrischer Ebenen von Char. 2}, series = {Journal f{\"u}r die reine und angewandte Mathematik}, volume = {250}, journal = {Journal f{\"u}r die reine und angewandte Mathematik}, publisher = {De Gruyter}, address = {Berlin}, isbn = {0075-4102}, doi = {10.1515/crll.1971.250.130}, pages = {130 -- 140}, year = {1971}, language = {de} } @article{Dienst1977, author = {Dienst, Karl-Jakob}, title = {Schnitt- und Zykelgeometrien}, series = {Geometriae Dedicata (1977)}, journal = {Geometriae Dedicata (1977)}, pages = {23 -- 54}, year = {1977}, language = {de} } @article{DienstOtt1972, author = {Dienst, Karl-Jakob and Ott, Udo}, title = {Spezielle nichtkommutative pappussche affine zweiseitige Inzidenzgruppen}, series = {Archiv der Mathematik}, volume = {23}, journal = {Archiv der Mathematik}, number = {1}, publisher = {Springer}, address = {Heidelberg}, isbn = {0003-889X}, doi = {10.1007/BF01304890}, pages = {329 -- 336}, year = {1972}, language = {de} } @article{DoeringFeldmannKuhnhenne2009, author = {D{\"o}ring, Bernd and Feldmann, Markus and Kuhnhenne, Markus}, title = {Der Beitrag von Profilblechdecken zur passiven K{\"u}hlung}, series = {Bauphysik}, volume = {Vol. 31}, journal = {Bauphysik}, number = {Iss. 2}, publisher = {Wiley}, address = {Weinheim}, isbn = {1437-0980 (E-Journal); 0171-5445 (Print)}, pages = {65 -- 71}, year = {2009}, language = {de} }