@article{BandodkarMolinnusMirzaetal.2014, author = {Bandodkar, Amay J. and Molinnus, Denise and Mirza, Omar and Guinovart, Tomas and Windmiller, Joshua R. and Valdes-Ramirez, Gabriela and Andrade, Francisco J. and Sch{\"o}ning, Michael Josef and Wang, Joseph}, title = {Epidermal tattoo potentiometric sodium sensors with wireless signal transduction for continuous non-invasive sweat monitoring}, series = {Biosensors and bioelectronics}, volume = {54}, journal = {Biosensors and bioelectronics}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-4235 (E-Journal); 0956-5663 (Print)}, doi = {10.1016/j.bios.2013.11.039}, pages = {603 -- 609}, year = {2014}, abstract = {This article describes the fabrication, characterization and application of an epidermal temporary-transfer tattoo-based potentiometric sensor, coupled with a miniaturized wearable wireless transceiver, for real-time monitoring of sodium in the human perspiration. Sodium excreted during perspiration is an excellent marker for electrolyte imbalance and provides valuable information regarding an individual's physical and mental wellbeing. The realization of the new skin-worn non-invasive tattoo-like sensing device has been realized by amalgamating several state-of-the-art thick film, laser printing, solid-state potentiometry, fluidics and wireless technologies. The resulting tattoo-based potentiometric sodium sensor displays a rapid near-Nernstian response with negligible carryover effects, and good resiliency against various mechanical deformations experienced by the human epidermis. On-body testing of the tattoo sensor coupled to a wireless transceiver during exercise activity demonstrated its ability to continuously monitor sweat sodium dynamics. The real-time sweat sodium concentration was transmitted wirelessly via a body-worn transceiver from the sodium tattoo sensor to a notebook while the subjects perspired on a stationary cycle. The favorable analytical performance along with the wearable nature of the wireless transceiver makes the new epidermal potentiometric sensing system attractive for continuous monitoring the sodium dynamics in human perspiration during diverse activities relevant to the healthcare, fitness, military, healthcare and skin-care domains.}, language = {en} } @article{ReisertGeisslerFloerkeetal.2013, author = {Reisert, Steffen and Geissler, Hanno and Fl{\"o}rke, Rudolf and Weiler, Christian and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Characterisation of aseptic sterilisation processes using an electronic nose}, series = {International journal of nanotechnology}, volume = {Vol. 10}, journal = {International journal of nanotechnology}, number = {No. 5-7}, publisher = {Inderscience Enterprises}, address = {Gen{\`e}ve}, issn = {1475-7435 (Print) 7141-8151 (Online)}, pages = {470 -- 484}, year = {2013}, language = {en} } @article{Dikta2014, author = {Dikta, Gerhard}, title = {Asymptotically efficient estimation under semi-parametric random censorship models}, series = {Journal of multivariate analysis}, volume = {124}, journal = {Journal of multivariate analysis}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1095-7243 (E-Journal); 0047-259X (Print)}, doi = {10.1016/j.jmva.2013.10.002}, pages = {10 -- 24}, year = {2014}, abstract = {We study the estimation of some linear functionals which are based on an unknown lifetime distribution. The observations are assumed to be generated under the semi-parametric random censorship model (SRCM), that is, a random censorship model where the conditional expectation of the censoring indicator given the observation belongs to a parametric family. Under this setup a semi-parametric estimator of the survival function was introduced by the author. If the parametric model assumption is correct, it is known that the estimated functional which is based on this semi-parametric estimator is asymptotically at least as efficient as the corresponding one which rests on the nonparametric Kaplan-Meier estimator. In this paper we show that the estimated functional which is based on this semi-parametric estimator is asymptotically efficient with respect to the class of all regular estimators under this semi-parametric model.}, language = {en} } @article{MiyamotoHirayamaWagneretal.2013, author = {Miyamoto, Ko-ichiro and Hirayama, Yuji and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Visualization of enzymatic reaction in a microfluidic channel using chemical imaging sensor}, series = {Electrochimica acta}, journal = {Electrochimica acta}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3859 (E-Journal); 0013-4686 (Print)}, pages = {Publ. online}, year = {2013}, language = {en} } @misc{IngebrandtWagnerSchoening2013, author = {Ingebrandt, Sven and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Engineering of functional interfaces / guest eds. Sven Ingebrandt ; Patrick Wagner ; Michael J. Sch{\"o}ning}, series = {Physica Status Solidi (A)}, volume = {Vol. 210}, journal = {Physica Status Solidi (A)}, number = {Iss. 5}, issn = {1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print)}, pages = {845}, year = {2013}, language = {en} } @misc{AbdelghaniMenaaObareetal.2013, author = {Abdelghani, Adnane and Menaa, Bouzid and Obare, Sherine O. and Sch{\"o}ning, Michael Josef}, title = {Special issue on nanoscale science and technology / guest eds.: Adnane Abdelghani, Bouzid Menaa, Sherine O. Obare, Michael J. Sch{\"o}ning}, series = {International journal of nanotechnology}, volume = {Vol. 10}, journal = {International journal of nanotechnology}, number = {No. 5-7}, issn = {1741-8151 (E-Journal), 1475-7435 (Print)}, pages = {373 -- 619}, year = {2013}, language = {en} } @article{JiminezGermanBehbahaniMiettinenetal.2013, author = {Jiminez German, Salvador and Behbahani, Mehdi and Miettinen, Susanna and Grijpma, Dirk W. and Haimi, Suvi P.}, title = {Proliferation and differentiation of adipose stem cells towards smooth muscle cells on poly(trimethylene carbonate) membranes}, series = {Macromolecular symposia}, volume = {Vol. 334}, journal = {Macromolecular symposia}, number = {Iss. 1}, publisher = {Wiley}, address = {Weinheim}, issn = {0258-0322}, pages = {133 -- 142}, year = {2013}, language = {en} } @inproceedings{TersteggeWeberHerzogetal.1997, author = {Terstegge, Andreas and Weber, S. and Herzog, H. and M{\"u}ller-G{\"a}rtner, H. W. and Halling, H.}, title = {Design and implementation aspects of a 3D reconstruction algorithm for the J{\"u}lich TierPET system}, series = {1997 International Meeting on Fully ThreeDimensional Image Reconstruction in Radiology and Nuclear Medicine : 3D97}, booktitle = {1997 International Meeting on Fully ThreeDimensional Image Reconstruction in Radiology and Nuclear Medicine : 3D97}, pages = {170 -- 173}, year = {1997}, language = {en} } @inproceedings{WeberTersteggeEngelsetal.1996, author = {Weber, S. and Terstegge, Andreas and Engels, R. and Herzog, H. and Reinartz, R. and Reinhart, P. and Rongen, F. and M{\"u}ller-G{\"a}rtner, H. W. and Halling, H.}, title = {The KFA TierPET: performance characteristics and measurements}, series = {Conference record / 1996 IEEE Nuclear Science Symposium [and Medical Imaging], November 2 - 9, 1996, Anaheim, California ; vol. 2}, booktitle = {Conference record / 1996 IEEE Nuclear Science Symposium [and Medical Imaging], November 2 - 9, 1996, Anaheim, California ; vol. 2}, publisher = {IEEE}, address = {Piscataway, NJ}, organization = {Institute of Electrical and Electronics Engineers}, isbn = {0-7803-3534-1}, issn = {1082-3654}, pages = {1117 -- 1119}, year = {1996}, language = {en} } @inproceedings{WeberTersteggeHallingetal.1995, author = {Weber, S. and Terstegge, Andreas and Halling, H. and Herzog, H. and Reinartz, R. and Reinhart, P. and Rongen, F. and M{\"u}ller-G{\"a}rtner, H.-W.}, title = {The design of an animal PET: flexible geometry for achieving optimal spatial resolution or high sensitivity}, series = {Conference record / 1995 IEEE Nuclear Science Symposium and Medical Imaging, October 21 - 28, 1995, San Francisco ; vol. 2}, booktitle = {Conference record / 1995 IEEE Nuclear Science Symposium and Medical Imaging, October 21 - 28, 1995, San Francisco ; vol. 2}, publisher = {IEEE}, address = {Piscataway, NJ}, organization = {Institute of Electrical and Electronics Engineers}, isbn = {078033180X ; 0780331818 ; 0780331826}, pages = {1002 -- 1005}, year = {1995}, language = {en} } @article{SawadaNakazawaTakenagaetal.2014, author = {Sawada, Kazuaki and Nakazawa, Hirokazu and Takenaga, Shoko and Hizawa, Takeshi and Futagawa, Masato and Dasai, Fumihiro and Sakurai, Takashi and Okumura, Koichi and Hattori, Toshiaki and Ishida, Makoto}, title = {Multimodal bioimage sensor}, series = {IEICE transactions on fundamentals of electronics, communidations and computer sciences}, volume = {E97-A (2014)}, journal = {IEICE transactions on fundamentals of electronics, communidations and computer sciences}, number = {3}, publisher = {IEICE}, address = {Tokyo}, issn = {0916-8508 (Print) ; 1745-1337 (Online)}, doi = {10.1587/transfun.E97.A.726}, pages = {726 -- 733}, year = {2014}, abstract = {To visualize the biochemical distribution two-dimensionally, we invented a solid-state-type ion image sensor that indicates the chemical activity of solutions and cells. The device, which consists of a CCD array covered with a functionalized membrane to detect charge accumulation, is highly sensitive to changes in the concentration and two-dimensional distribution of ions and biomaterials.}, language = {en} } @article{OberlaenderKirchnerBoyenetal.2014, author = {Oberl{\"a}nder, Jan and Kirchner, Patrick and Boyen, Hans-Gerd and Sch{\"o}ning, Michael Josef}, title = {Detection of hydrogen peroxide vapor by use of manganese(IV) oxide as catalyst for calorimetric gas sensors}, series = {Physica status solidi A: Applications and materials science}, volume = {211}, journal = {Physica status solidi A: Applications and materials science}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print)}, doi = {10.1002/pssa.201330359}, pages = {1372 -- 1376}, year = {2014}, abstract = {In this work, the catalyst manganese(IV) oxide (MnO2), of calorimetric gas sensors (to monitor the sterilization agent vaporized hydrogen peroxide) has been investigated in more detail. Chemical analyses by means of X-ray-induced photoelectron spectroscopy have been performed to unravel the surface chemistry prior and after exposure to hydrogen peroxide vapor at elevated temperature, as applied in the sterilization processes of beverage cartons. The surface characterization reveals a change in oxidation states of the metal oxide catalyst after exposure to hydrogen peroxide. Additionally, a cleaning effect of the catalyst, which itself is attached to the sensor surface by means of a polymer interlayer, could be observed.}, language = {en} } @article{FuestKotliarWalteretal.2014, author = {Fuest, Matthias and Kotliar, Konstantin and Walter, Peter and Plange, Niklas}, title = {Monitoring intraocular pressure changes after intravitreal Ranibizumab injection using rebound tonometry}, series = {Ophthalmic and physiological optics}, volume = {34}, journal = {Ophthalmic and physiological optics}, number = {4}, publisher = {Wiley-Blackwell}, address = {Oxford}, issn = {1475-1313 (E-Journal); 0275-5408 (Print)}, doi = {10.1111/opo.12134}, pages = {438 -- 444}, year = {2014}, language = {en} } @inproceedings{SchreiberHirtbachKraftetal.2013, author = {Schreiber, Marc and Hirtbach, Stefan and Kraft, Bodo and Steinmetzler, Andreas}, title = {Software in the city: visual guidance through large scale software projects}, series = {Software Engineering 2013 : Fachtagung des GI-Fachbereichs Softwaretechnik, 26. Februar-1. M{\"a}rz 2013 in Aachen. (GI-Edition ; 213)}, booktitle = {Software Engineering 2013 : Fachtagung des GI-Fachbereichs Softwaretechnik, 26. Februar-1. M{\"a}rz 2013 in Aachen. (GI-Edition ; 213)}, editor = {Kowalewski, Stefan}, publisher = {Ges. f{\"u}r Informatik}, address = {Bonn}, isbn = {978-3-88579-607-7 ; 978-3-88579-609-1}, pages = {213 -- 224}, year = {2013}, language = {en} } @inproceedings{SchreiberBarkschatKraft2014, author = {Schreiber, Marc and Barkschat, Kai and Kraft, Bodo}, title = {Using Continuous Integration to organize and monitor the annotation process of domain specific corpora}, series = {5th International Conference on Information and Communication Systems (ICICS) : 1-3 April 2014, Irbid, Jordanien}, booktitle = {5th International Conference on Information and Communication Systems (ICICS) : 1-3 April 2014, Irbid, Jordanien}, organization = {International Conference on Information and Communication Systems <5, 2014, Irbid, Jordanien>}, isbn = {978-1-4799-3022-7}, doi = {10.1109/IACS.2014.6841958}, pages = {1 -- 6}, year = {2014}, language = {en} } @article{RiedelKartchemnikSchoeningetal.2014, author = {Riedel, Marc and Kartchemnik, Julia and Sch{\"o}ning, Michael Josef and Lisdat, Fred}, title = {Impedimetric DNA detection - steps forward to sensorial application}, series = {Analytical chemistry}, volume = {86 (2014)}, journal = {Analytical chemistry}, number = {15}, publisher = {ACS Publications}, address = {Columbus}, issn = {1520-6882 (E-Journal); 0003-2700 (Print); 0096-4484 (Print)}, doi = {10.1021/ac501800q}, pages = {7867 -- 7874}, year = {2014}, abstract = {This study describes a label-free impedimetric sensor based on short ssDNA recognition elements for the detection of hybridization events. We concentrate on the elucidation of the influence of target length and recognition sequence position on the sensorial performance. The impedimetric measurements are performed in the presence of the redox system ferri-/ferrocyanide and show an increase in charge transfer resistance upon hybridization of ssDNA to the sensor surface. Investigations on the impedimetric signal stability demonstrate a clear influence of the buffers used during the sensor preparation and the choice of the passivating mercaptoalcanol compound. A stable sensor system has been developed, enabling a reproducible detection of 25mer target DNA in the low nanomolar range. After hybridization, a sensor regeneration can be reached with deionized water by adjustment of effective convection conditions, ensuring a sensor reusability. By investigations of longer targets with overhangs exposed to the solution, we can demonstrate applicability of the impedimetric detection for longer ssDNA. However, a decreasing charge transfer resistance change (ΔRct) is found by extending the overhang. As a strategy to increase the impedance change for longer target strands, the position of the recognition sequence can be designed in a way that a small overhang is exposed to the electrode surface. This is found to result in an increase in the relative Rct change. These results suggest that DNA and consequently negative charge near the electrode possess a larger impact on the impedimetric signal than DNA further away.}, language = {en} } @article{GuoSekiMiyamotoetal.2014, author = {Guo, Yuanyuan and Seki, Kosuke and Miyamoto, Ko-ichiro and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Novel photoexcitation method for light-addressable potentiometric sensor with higher spatial resolution}, series = {Applied physics express : APEX}, volume = {7}, journal = {Applied physics express : APEX}, number = {6}, publisher = {IOP}, address = {Bristol}, issn = {1882-0786 (E-Journa); 1882-0778 (Print)}, doi = {10.7567/APEX.7.067301}, pages = {067301-4}, year = {2014}, abstract = {A novel photoexcitation method for the light-addressable potentiometric sensor (LAPS) is proposed to achieve a higher spatial resolution of chemical images. The proposed method employs a combined light source that consists of a modulated light probe, which generates the alternating photocurrent signal, and a ring of constant illumination surrounding it. The constant illumination generates a sheath of carriers with increased concentration which suppresses the spread of photocarriers by enhanced recombination. A device simulation was carried out to verify the effect of constant illumination on the spatial resolution, which demonstrated that a higher spatial resolution can be obtained.}, language = {en} } @article{WagnerDollSchoening2014, author = {Wagner, Patrick and Doll, Theodor and Sch{\"o}ning, Michael Josef}, title = {Engineering of functional interfaces / Patrick Wagner ; Theodor Doll ; Michael J. Sch{\"o}ning (eds.)}, series = {Physica status solidi (A) : Applications and materials science}, volume = {211}, journal = {Physica status solidi (A) : Applications and materials science}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-396X (E-Book); 1862-6319 (E-Book); 0031-8965 (Print); 1862-6300 (Print)}, doi = {10.1002/pssa.201470241}, pages = {1339 -- 1339}, year = {2014}, language = {en} } @article{OberlaenderBrommWendeleretal.2015, author = {Oberl{\"a}nder, Jan and Bromm, Alexander and Wendeler, Luisa and Iken, Heiko and Palomar Duran, Marlena and Greeff, Anton and Kirchner, Patrick and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Towards a biosensor to monitor the sterilisation efficiency of aseptic filling machines}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431900}, pages = {1299 -- 1305}, year = {2015}, abstract = {Sterilisation processes are compulsory in medicine, pharmacy, and food industries to prevent infections of consumers and microbiological contaminations of products. Monitoring the sterilisation by conventional microbiological methods is time- and lab-consuming. To overcome this problem, in this work a novel biosensor has been proposed. The sensor enables a fast method to evaluate sterilisation processes. By means of thin-film technology the sensor's transducer structures in form of IDEs (interdigitated electrodes) have been fabricated on a silicon substrate. Physical characterisation of the developed sensor was done by AFM, SEM, and profilometry. Impedance analyses were conducted for the electrical characterisation. As microbiological layer spores of B. atrophaeus have been immobilised on the sensing structure; spores of this type are a well-known sterilisation test organism. Impedance measurements at a fixed frequency over time were performed to monitor the immobilisation process. A sterilisation process according to aseptic filling machines was applied to demonstrate the sensor functionality. After both, immobilisation and sterilisation, a change in impedance could successfully be detected.}, language = {en} } @article{JildehWagnerSchoeningetal.2015, author = {Jildeh, Zaid B. and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Pieper, Martin}, title = {Simulating the electromagnetic-thermal treatment of thin aluminium layers for adhesion improvement}, series = {Physica status solidi (a)}, volume = {Vol. 212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431893}, pages = {1234 -- 1241}, year = {2015}, abstract = {A composite layer material used in packaging industry is made from joining layers of different materials using an adhesive. An important processing step in the production of aluminium-containing composites is the surface treatment and consequent coating of adhesive material on the aluminium surface. To increase adhesion strength between aluminium layer and the adhesive material, the foil is heat treated. For efficient heating, induction heating was considered as state-of-the-art treatment process. Due to the complexity of the heating process and the unpredictable nature of the heating source, the control of the process is not yet optimised. In this work, a finite element analysis of the process was established and various process parameters were studied. The process was simplified and modelled in 3D. The numerical model contains an air domain, an aluminium layer and a copper coil fitted with a magnetic field concentrating material. The effect of changing the speed of the aluminium foil (or rolling speed) was studied with the change of the coil current. Statistical analysis was used for generating a general control equation of coil current with changing rolling speed.}, language = {en} }