@article{BehnamBeckerWeber2011, author = {Behnam, S. and Becker, A. and Weber, Hans-Joachim}, title = {Clinical benefit and cost-efficiency of minimized perfusion circuits for extracorporeal circulation during cardiac surgery}, series = {Zeitschrift f{\"u}r Herz-, Thorax- und Gef{\"a}ßchirurgie}, volume = {25}, journal = {Zeitschrift f{\"u}r Herz-, Thorax- und Gef{\"a}ßchirurgie}, number = {5}, publisher = {Springer}, address = {Berlin}, issn = {0930-9225}, pages = {305 -- 306}, year = {2011}, language = {en} } @article{BaeckerDellePoghossianetal.2011, author = {B{\"a}cker, Matthias and Delle, L. and Poghossian, Arshak and Biselli, Manfred and Zang, Werner and Wagner, P. and Sch{\"o}ning, Michael Josef}, title = {Electrochemical sensor array for bioprocess monitoring}, series = {Electrochimica Acta (2011)}, volume = {56}, journal = {Electrochimica Acta (2011)}, number = {26}, publisher = {Elsevier}, address = {Amsterdam}, pages = {9673 -- 9678}, year = {2011}, language = {en} } @article{BerretzSkorupaSanderetal.2011, author = {Berretz, Frank and Skorupa, Sasche and Sander, Volker and Belloum, Adam and Bubak, Marian}, title = {Actor-Driven Workflow Execution in Distributed Environments}, series = {Euro-Par 2010 Parallel Processing Workshops : HeteroPAR, HPCC, HiBB, CoreGrid, UCHPC, HPCF, PROPER, CCPI, VHPC ; Ischia, Italy, August 31 - September 3, 2010 ; revised selected papers / Mario R. Guarracino ... (eds.)}, journal = {Euro-Par 2010 Parallel Processing Workshops : HeteroPAR, HPCC, HiBB, CoreGrid, UCHPC, HPCF, PROPER, CCPI, VHPC ; Ischia, Italy, August 31 - September 3, 2010 ; revised selected papers / Mario R. Guarracino ... (eds.)}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-642-21877-4}, pages = {287 -- 294}, year = {2011}, language = {en} } @article{BehbahaniBehrHormesetal.2009, author = {Behbahani, Mehdi and Behr, M. and Hormes, M. and Steinseifer, U. and Arora, D. and Coronado, O. and Pasquali, M.}, title = {A Review of Computational Fluid Dynamics Analysis of Blood Pumps}, series = {European Journal of Applied Mathematics. 20 (2009), H. 4}, journal = {European Journal of Applied Mathematics. 20 (2009), H. 4}, publisher = {Cambridge Univ. Press}, address = {Cambridge}, pages = {363 -- 397}, year = {2009}, language = {en} } @article{BehbahaniFinocchiaroHeinkeetal.2009, author = {Behbahani, Mehdi and Finocchiaro, Thomas and Heinke, Stefanie and Leßmann, Marc}, title = {Methods of design, simulation, and control for the development of new VAD/TAH concepts = Methoden zur Konstruktion, Simulation und Regelung f{\"u}r die Entwicklung von neuen VAD/TAH-Konzepten / Finocchiaro, Thomas ; Heinke, Stefanie ; Behbahani, Mehdi ; Leßma}, series = {Biomedizinische Technik / Biomedical Engineering. 54 (2009), H. 5}, journal = {Biomedizinische Technik / Biomedical Engineering. 54 (2009), H. 5}, isbn = {0013-5585}, pages = {269 -- 281}, year = {2009}, language = {en} } @article{BehbahaniSpillnerKoppetal.2009, author = {Behbahani, Mehdi and Spillner, Jan and Kopp, R{\"u}diger and Finocchiaro, Thomas}, title = {Assistierte Zirkulation : ein {\"U}berblick aus klinischer Sicht = Assisted circulation: an overview from a clinical perspective / Spillner, Jan ; Kopp, R{\"u}diger ; Finocchiaro, Thomas ; Behbahani, Mehdi ; Rossaint, Rolf ; Steinseifer, Ulrich ; Behr, Marek ; Au}, series = {Biomedizinische Technik / Biomedical Engineering. 54 (2009), H. 5}, journal = {Biomedizinische Technik / Biomedical Engineering. 54 (2009), H. 5}, publisher = {De Gruyter}, address = {Berlin}, isbn = {0013-5585}, pages = {255 -- 267}, year = {2009}, language = {de} } @article{BehbahaniBehrNicolaietal.2008, author = {Behbahani, Mehdi and Behr, Marek and Nicolai, Mike and Probst, Markus}, title = {Towards Shape Optimization for Ventricular Assist Devices Using Parallel Stabilized FEM}, series = {NIC Symposium 2008 : symposium, 20 - 21 February 2008, Forschungszentrum J{\"u}lich ; proceedings / organized by John von Neumann Institute for Computing. Ed. by Gernot M{\"u}nster; Dietrich Wolf; Manfred Kremer (ed.)}, journal = {NIC Symposium 2008 : symposium, 20 - 21 February 2008, Forschungszentrum J{\"u}lich ; proceedings / organized by John von Neumann Institute for Computing. Ed. by Gernot M{\"u}nster; Dietrich Wolf; Manfred Kremer (ed.)}, publisher = {Forschungszentrum}, address = {J{\"u}lich}, isbn = {978-3-9810843-5-1}, pages = {325 -- 332}, year = {2008}, language = {en} } @article{BehbahaniNicolaiProbstetal.2007, author = {Behbahani, Mehdi and Nicolai, M. and Probst, M. and Behr, M.}, title = {Simulation of Blood Flow in a Ventricular Assist Device}, series = {inSIDE. 5 (2007), H. 1}, journal = {inSIDE. 5 (2007), H. 1}, pages = {28 -- 31}, year = {2007}, language = {en} } @article{BehbahaniBehrBischofetal.2007, author = {Behbahani, Mehdi and Behr, M. and Bischof, F. and Wolf, G. E.}, title = {Kranken Herzen helfen - Ingenieure und Informatiker entwickeln gemeinsam eine Miniaturblutpumpe / Behbahani, M. ; Behr, M. ; Bischof, F. ; Wolf, G. E.}, series = {RWTH-Themen (2007)}, journal = {RWTH-Themen (2007)}, isbn = {0179-079X}, pages = {44 -- 46}, year = {2007}, language = {de} } @article{BehbahaniNicolai2006, author = {Behbahani, Mehdi and Nicolai, M.}, title = {Interaktive Exploration von Blutstr{\"o}mungsprozessen in Herzpumpen}, series = {VRCA-Jahresbericht 2005/2006}, journal = {VRCA-Jahresbericht 2005/2006}, publisher = {Virtual Reality Center}, address = {Aachen}, pages = {88 -- 90}, year = {2006}, language = {de} } @article{BehbahaniBehrAroraetal.2006, author = {Behbahani, Mehdi and Behr, M. and Arora, D. and Coronado, O. and Pasquali, M.}, title = {CFD Analysis of MicroMed Debakey Pump and Hemolysis Prediction / Behbahani, M. ; Behr, M. ; Arora, D. ; Coronado, O. ; Pasquali, M.}, series = {Artificial Organs. 30 (2006), H. 11}, journal = {Artificial Organs. 30 (2006), H. 11}, isbn = {1525-1594}, pages = {A45 -- A46}, year = {2006}, language = {en} } @article{SteinseiferKashefiHormesetal.2009, author = {Steinseifer, Ulrich and Kashefi, Ali and Hormes, Marcus and Schoberer, Mark and Orlikowsky, Thorsten and Behbahani, Mehdi and Behr, Marek and Schmitz-Rode, Thomas}, title = {Miniaturization of ECMO Systems : Engineering Challenges and Methods}, series = {Artificial Organs. 33 (2009), H. 5}, journal = {Artificial Organs. 33 (2009), H. 5}, isbn = {1525-1594}, pages = {A55 -- A55}, year = {2009}, language = {en} } @article{BehbahaniProbstMaietal.2010, author = {Behbahani, Mehdi and Probst, M. and Mai, A. and Tran, L. and Vonderstein, K. and Keschenau, P. and Linde, T. and Steinseifer, U. and Behr, M. and Mottaghy, K.}, title = {The influence of high shear on thrombosis and hemolysis in artificial organs}, series = {Artificial Organs}, volume = {33}, journal = {Artificial Organs}, number = {7}, isbn = {0391-3988}, pages = {426 -- 426}, year = {2010}, language = {en} } @article{JansenBehbahaniLaumenetal.2010, author = {Jansen, Sebastian and Behbahani, Mehdi and Laumen, Marco and Kaufmann, Tim and Hormes, Marcus and Schmitz-Rode, Thomas and Behr, Marek and Steinseifer, Ulrich}, title = {3D Stereo-PIV Validation for CFD-Simulation of Steady Flow through the Human Aorta using Rapid-Prototyping techniques}, year = {2010}, language = {en} } @article{WagnerMiyamotoWerneretal.2011, author = {Wagner, Torsten and Miyamoto, K. and Werner, Frederik and Sch{\"o}ning, Michael Josef and Yoshinobu, T.}, title = {Flexible electrochemical imaging with "zoom-in" functionality by using a new type of light-addressable potentiometric sensor}, publisher = {IEEE}, address = {New York}, pages = {2133 -- 2135}, year = {2011}, language = {en} } @article{MiyamotoWagnerSchoeningetal.2011, author = {Miyamoto, K. and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, T.}, title = {Multi-well structure for cell culture on the chemical imaging sensor}, publisher = {IEEE}, address = {New York}, pages = {2130 -- 2132}, year = {2011}, language = {en} } @article{BehbahaniMaiBergmannetal.2010, author = {Behbahani, Mehdi and Mai, A. and Bergmann, B. and Waluga, C. and Behr, M. and Tran, L. and Vonderstein, K. and Mottaghy, K.}, title = {Modeling and Numerical Simulation of Blood Damage}, year = {2010}, language = {en} } @article{BehbahaniWalugaArltetal.2008, author = {Behbahani, Mehdi and Waluga, C. and Arlt, S. and Behr, M. and Mottaghy, K.}, title = {Computational Analysis of Platelet Aggregation in a Taylor-Couette System}, series = {The International Journal of Artificial Organs. 31 (2008), H. 7}, journal = {The International Journal of Artificial Organs. 31 (2008), H. 7}, isbn = {0391-3988}, pages = {643}, year = {2008}, language = {en} } @article{BehbahaniMaiWalugaetal.2010, author = {Behbahani, Mehdi and Mai, A. and Waluga, C. and Bergmann, B. and Tran, L. and Vonderstein, K. and Behr, M. and Mottaghy, K.}, title = {Numerical Modeling of Flow-Related Thrombus Formation under Physiological and Non-Physiological Flow Conditions}, series = {Acta Physiologica}, volume = {198}, journal = {Acta Physiologica}, number = {Supplement 677}, isbn = {1748-1716}, pages = {185}, year = {2010}, language = {en} } @article{BehbahaniTranJockenhoeveletal.2011, author = {Behbahani, Mehdi and Tran, L. and Jockenh{\"o}vel, S. and Behr, M. and Mottaghy, K.}, title = {Numerical prediction of thrombocyte reactions for application to a vascular flow model}, series = {British Journal of Surgery}, volume = {98}, journal = {British Journal of Surgery}, number = {S5}, publisher = {Oxford University Press}, address = {Oxford}, isbn = {1365-2168}, pages = {S17}, year = {2011}, language = {en} } @article{BehbahaniTranWalugaetal.2009, author = {Behbahani, Mehdi and Tran, L. and Waluga, C. and Behr, M. and Oedekoven, B. and Mottaghy, K.}, title = {Model-based Numerical Analysis of Platelet Adhesion, Thrombus Growth and Aggregation for Assist Devices}, series = {The International Journal of Artificial Organs. 32 (2009), H. 7}, journal = {The International Journal of Artificial Organs. 32 (2009), H. 7}, isbn = {0391-3988}, pages = {398 -- 398}, year = {2009}, language = {en} } @article{BehbahaniNamWalugaetal.2010, author = {Behbahani, Mehdi and Nam, J. and Waluga, C. and Behr, M. and Pasquali, M. and Mottaghy, K.}, title = {Modeling and Numerical Analysis of Platelet Activation, Adhesion and Aggregation in Artificial Organs}, doi = {10.1097/01.mat.0000369377.65122.a3}, year = {2010}, language = {en} } @article{JansenBehbahaniLaumenetal.2010, author = {Jansen, S. V. and Behbahani, Mehdi and Laumen, M. and Kaufmann, T. and Hormes, M. and Behr, M. and Schmitz-Rode, T. and Steinseifer, U.}, title = {Investigation of Steady Flow Through a Realistic Model of the Thoracic Human Aorta Using 3D Stereo PIV and CFD-Simulation}, year = {2010}, language = {en} } @article{NamAroraBehbahanietal.2010, author = {Nam, J. and Arora, D. and Behbahani, Mehdi and Probst, M. and Benkowski, R. and Behr, M. and Pasquali, M.}, title = {New computational method in hemolysis analysis for artificial heart pump}, year = {2010}, language = {en} } @article{BehbahaniProbstMaietal.2010, author = {Behbahani, Mehdi and Probst, M. and Mai, A. and Behr, M. and Tran, L. and Vonderstein, K. and Mottaghy, K.}, title = {Numerical Prediction of Blood Damage in Biomedical Devices}, year = {2010}, language = {en} } @article{ProbstBehbahaniBorrmannetal.2010, author = {Probst, M. and Behbahani, Mehdi and Borrmann, E. and Elgeti, S. and Nicolai, M. and Behr, M.}, title = {Hemodynamic Modeling for Numerical Analysis and Design of Medical Devices}, year = {2010}, language = {en} } @article{BehbahaniWalugaStocketal.2009, author = {Behbahani, Mehdi and Waluga, C. and Stock, S. and Mai, A. and Bergmann, B. and Behr, M. and Tran, L. and Vonderstein, K. and Scheidt, H. and Oedekoven, B. and Mottaghy, K.}, title = {Modelling and Numerical Analysis of Platelet Reactions and Surface Thrombus Growth}, year = {2009}, language = {en} } @article{HuckJollyWagneretal.2011, author = {Huck, Christina and Jolly, Christina and Wagner, Patrick and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {One-chip integrated dual amperometric/field-effect sensor for the detection of dissolved hydrogen}, series = {Procedia Engineering. 25 (2011)}, journal = {Procedia Engineering. 25 (2011)}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1877-7058}, pages = {1161 -- 1164}, year = {2011}, language = {en} } @article{WagnerMiyamotoShigiharaetal.2011, author = {Wagner, Torsten and Miyamoto, Ko-ichiro and Shigihara, Noriko and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Microfluidic systems with free definable sensor spots by an integrated light-addressable potentiometric sensor}, series = {Procedia Engineering. 25 (2011)}, journal = {Procedia Engineering. 25 (2011)}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1877-7058}, pages = {791 -- 794}, year = {2011}, language = {en} } @article{BohrnStuetzFuchsetal.2011, author = {Bohrn, U. and St{\"u}tz, E. and Fuchs, K. and Fleischer, M. and Sch{\"o}ning, Michael Josef and Wagner, P.}, title = {Air Quality Monitoring using a Whole-Cell based Sensor System}, series = {Procedia Engineering. 25 (2011)}, journal = {Procedia Engineering. 25 (2011)}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1877-7058}, pages = {1421 -- 1424}, year = {2011}, language = {en} } @article{WernerWagnerMiyamotoetal.2011, author = {Werner, Frederik and Wagner, Torsten and Miyamoto, Ko-ichiro and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {High speed and high resolution chemical imaging based on a new type of OLED-LAPS set-up}, series = {Procedia Engineering. 25 (2011)}, journal = {Procedia Engineering. 25 (2011)}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1877-7058}, pages = {346 -- 349}, year = {2011}, language = {en} } @article{PoghossianMalzahnAbouzaretal.2011, author = {Poghossian, Arshak and Malzahn, K. and Abouzar, Maryam H. and Mehndiratta, P. and Katz, E. and Sch{\"o}ning, Michael Josef}, title = {Integration of biomolecular logic gates with field-effect transducers}, series = {Electrochimica Acta. 56 (2011), H. 26}, journal = {Electrochimica Acta. 56 (2011), H. 26}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0013-4686}, pages = {9661 -- 9665}, year = {2011}, language = {en} } @article{LeimenaArtmannDachwaldetal.2010, author = {Leimena, W. and Artmann, Gerhard and Dachwald, Bernd and Temiz Artmann, Ayseg{\"u}l and Gossmann, Matthias and Digel, Ilya}, title = {Feasibility of an in-situ microbial decontamination of an ice-melting probe}, series = {Eurasian Chemico-Technological Journal. 12 (2010), H. 2}, journal = {Eurasian Chemico-Technological Journal. 12 (2010), H. 2}, isbn = {1562-3920}, pages = {145 -- 150}, year = {2010}, language = {en} } @article{GrinsvenBonStrauvenetal.2012, author = {Grinsven, Bart van and Bon, Natalie vanden and Strauven, Hannelore and Grieten, Lars and Murib, Mohammed and Jim{\´e}nez Monroy, Kathia L. and Janssens, Stoffel D. and Haenen, Ken and Sch{\"o}ning, Michael Josef and Vermeeren, Veronique and Ameloot, Marcel and Michiels, Luc and Thoelen, Ronald and Ceuninck, Ward de and Wagner, Patrick}, title = {Heat-Transfer Resistance at Solid-Liquid Interfaces: A Tool for The Detection of Single Nucleotide Polymorphisms in DNA.}, series = {ACS Nano}, volume = {6}, journal = {ACS Nano}, number = {3}, publisher = {ACS Publications}, address = {Washington, DC}, issn = {1936-086X}, doi = {10.1021/nn300147e}, pages = {2712 -- 2721}, year = {2012}, abstract = {In this article, we report on the heat-transfer resistance at interfaces as a novel, denaturation-based method to detect single-nucleotide polymorphisms in DNA. We observed that a molecular brush of double-stranded DNA grafted onto synthetic diamond surfaces does not notably affect the heat-transfer resistance at the solid-to-liquid interface. In contrast to this, molecular brushes of single-stranded DNA cause, surprisingly, a substantially higher heat-transfer resistance and behave like a thermally insulating layer. This effect can be utilized to identify ds-DNA melting temperatures via the switching from low- to high heat-transfer resistance. The melting temperatures identified with this method for different DNA duplexes (29 base pairs without and with built-in mutations) correlate nicely with data calculated by modeling. The method is fast, label-free (without the need for fluorescent or radioactive markers), allows for repetitive measurements, and can also be extended toward array formats. Reference measurements by confocal fluorescence microscopy and impedance spectroscopy confirm that the switching of heat-transfer resistance upon denaturation is indeed related to the thermal on-chip denaturation of DNA.}, language = {en} } @article{AridaAlhaddadSchoening2011, author = {Arida, Hassan A. and Al-haddad, Ameera and Sch{\"o}ning, Michael Josef}, title = {New Solid-State Organic Membrane Based Lead-Selective Micro-Electrode}, series = {International Journal of Electrochemical Science. 6 (2011), H. 9}, journal = {International Journal of Electrochemical Science. 6 (2011), H. 9}, isbn = {1452-3981}, pages = {3858 -- 3867}, year = {2011}, language = {en} } @article{AbouzarPoghossianCherstvyetal.2012, author = {Abouzar, Maryam H. and Poghossian, Arshak and Cherstvy, Andrey G. and Pedraza, Angela M. and Ingebrandt, Sven and Sch{\"o}ning, Michael Josef}, title = {Label-free electrical detection of DNA by means of field-effect nanoplate capacitors: Experiments and modeling}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100710}, pages = {925 -- 934}, year = {2012}, abstract = {Label-free electrical detection of consecutive deoxyribonucleic acid (DNA) hybridization/denaturation by means of an array of individually addressable field-effect-based nanoplate silicon-on-insulator (SOI) capacitors modified with gold nanoparticles (Au-NP) is investigated. The proposed device detects charge changes on Au-NP/DNA hybrids induced by the hybridization or denaturation event. DNA hybridization was performed in a high ionic-strength solution to provide a high hybridization efficiency. On the other hand, to reduce the screening of the DNA charge by counter ions and to achieve a high sensitivity, the sensor signal induced by the hybridization and denaturation events was measured in a low ionic-strength solution. High sensor signals of about 120, 90, and 80 mV were registered after the DNA hybridization, denaturation, and re-hybridization events, respectively. Fluorescence microscopy has been applied as reference method to verify the DNA immobilization, hybridization, and denaturation processes. An electrostatic charge-plane model for potential changes at the gate surface of a nanoplate field-effect sensor induced by the DNA hybridization has been developed taking into account both the Debye length and the distance of the DNA charge from the gate surface.}, language = {en} } @article{StaatTrenzLohmannetal.2012, author = {Staat, Manfred and Trenz, Eva and Lohmann, Philipp and Frotscher, Ralf and Klinge, Uwe and Tabaza, Ruth and Kirschner-Hermanns, Ruth}, title = {New measurements to compare soft tissue anchoring systems in pelvic floor surgery}, series = {Journal of Biomedical Materials Research Part B: Applied Biomaterials}, volume = {100B}, journal = {Journal of Biomedical Materials Research Part B: Applied Biomaterials}, number = {4}, publisher = {Wiley}, address = {Hoboken, NJ}, issn = {1552-4981}, doi = {10.1002/jbm.b.32654}, pages = {924 -- 933}, year = {2012}, abstract = {Suburethral slings as well as different meshes are widely used treating stress urinary incontinence and prolaps in women. With the development of MiniSlings and special meshes using less alloplastic material anchorage systems become more important to keep devices in place and to put some tension especially on the MiniSlings. To date, there are many different systems of MiniSlings of different companies on the market which differ in the structure of the used meshes and anchors. A new objective measurement method to compare different properties of MiniSling systems (mesh and anchor) is presented in this article. Ballistic gelatine acts as soft tissue surrogate. Significant differences in parameters like pull-out strength of anchors or shrinkage of meshes under loading conditions have been determined. The form and size of the anchors as well as the structural stability of the meshes are decisive for a proper integration. The tested anchorings sytems showed markedly different mechanical function at their respective load bearing capacity. As the stable fixation of the device in tissue is a prerequisite for a permanet reinforcement, the proposed test system permits further optimisation of anchor and mesh devices to improve the success of the surgical treatment}, language = {en} } @article{BergmannDemuthSander2011, author = {Bergmann, Sandra and Demuth, Bastian and Sander, Volker}, title = {A Web Framework for Workflow Submission and Monitoring via UNICORE 6 based on Distributable Scientific Workflow Templates}, series = {UNICORE Summit 2011 : proceedings, 7-8 July 2011, Torun, Poland / Mathilde Romberg ... (Eds.)}, journal = {UNICORE Summit 2011 : proceedings, 7-8 July 2011, Torun, Poland / Mathilde Romberg ... (Eds.)}, publisher = {Forschungszentrum J{\"u}lich}, address = {J{\"u}lich}, isbn = {9783893367504}, pages = {45 -- 50}, year = {2011}, language = {en} } @article{KrottGerhardsSkorupaetal.2011, author = {Krott, Daniel and Gerhards, Michael and Skorupa, Sascha and Sander, Volker}, title = {NHiLA - Bridging the Gap Between .NET and UNICORE}, series = {UNICORE Summit 2011 : proceedings, 7-8 July 2011, Torun, Poland / Mathilde Romberg ... (Eds.)}, journal = {UNICORE Summit 2011 : proceedings, 7-8 July 2011, Torun, Poland / Mathilde Romberg ... (Eds.)}, publisher = {Forschungszentrum J{\"u}lich}, address = {J{\"u}lich}, isbn = {9783893367504}, pages = {77 -- 86}, year = {2011}, language = {en} } @article{GerhardsSkorupaSanderetal.2011, author = {Gerhards, M. and Skorupa, S. and Sander, Volker and Pfeiffer, P. and Belloum, A.}, title = {Towards a security framework for a WS-HumanTask processor}, series = {7th International Conference on Network and Service Management (CNSM), 2011 Paris}, journal = {7th International Conference on Network and Service Management (CNSM), 2011 Paris}, publisher = {IEEE}, address = {New York}, isbn = {978-3-901882-44-9}, pages = {1 -- 5}, year = {2011}, language = {en} } @article{BaeckerRaueSchusseretal.2012, author = {B{\"a}cker, Matthias and Raue, Markus and Schusser, Sebastian and Jeitner, C. and Breuer, L. and Wagner, P. and Poghossian, Arshak and F{\"o}rster, Arnold and Mang, Thomas and Sch{\"o}ning, Michael Josef}, title = {Microfluidic chip with integrated microvalves based on temperature- and pH-responsive hydrogel thin films}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100763}, pages = {839 -- 845}, year = {2012}, abstract = {Two types of microvalves based on temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm) and pH-responsive poly(sodium acrylate) (PSA) hydrogel films have been developed and tested. The PNIPAAm and PSA hydrogel films were prepared by means of in situ photopolymerization directly inside the fluidic channel of a microfluidic chip fabricated by combining Si and SU-8 technologies. The swelling/shrinking properties and height changes of the PNIPAAm and PSA films inside the fluidic channel were studied at temperatures of deionized water from 14 to 36 °C and different pH values (pH 3-12) of Titrisol buffer, respectively. Additionally, in separate experiments, the lower critical solution temperature (LCST) of the PNIPAAm hydrogel was investigated by means of a differential scanning calorimetry (DSC) and a surface plasmon resonance (SPR) method. Mass-flow measurements have shown the feasibility of the prepared hydrogel films to work as an on-chip integrated temperature- or pH-responsive microvalve capable to switch the flow channel on/off.}, language = {en} } @article{SpelthahnSchubertSchoening2012, author = {Spelthahn, Heiko and Schubert, J{\"u}rgen and Sch{\"o}ning, Michael Josef}, title = {D{\"u}nnschichtsensoren f{\"u}r die Schwermetallanalytik}, series = {GIT : Labor-Fachzeitschrift}, volume = {56}, journal = {GIT : Labor-Fachzeitschrift}, number = {4}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0016-3538}, pages = {285 -- 287}, year = {2012}, abstract = {Die Detektion von Schadstoffen repr{\"a}sentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte D{\"u}nnschichtsensoren bieten eine kosteng{\"u}nstige M{\"o}glichkeit, „online"-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuf{\"u}hren. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgl{\"a}sern zur Detektion von Schwermetallen in w{\"a}ssrigen Medien vorgestellt.}, language = {en} } @article{NovacekTranKlingeetal.2012, author = {Novacek, V. and Tran, Thanh Ngoc and Klinge, U. and Tolba, R. H. and Staat, Manfred and Bronson, D. G. and Miesse, A. M. and Whiffen, J. and Turquier, F.}, title = {Finite element modelling of stapled colorectal end-to-end anastomosis : Advantages of variable height stapler design}, series = {Journal of Biomechanics}, volume = {45}, journal = {Journal of Biomechanics}, number = {115}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-2380}, doi = {10.1016/j.jbiomech.2012.07.021}, pages = {2693 -- 2697}, year = {2012}, abstract = {The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge.}, language = {en} } @article{NguyenDuongTranetal.2012, author = {Nguyen, Nhu Huynh and Duong, Minh Tuan and Tran, Thanh Ngoc and Pham, Phu Tinh and Grottke, O. and Tolba, R. and Staat, Manfred}, title = {Influence of a freeze-thaw cycle on the stress-stretch curves of tissues of porcine abdominal organs}, series = {Journal of Biomechanics}, volume = {45}, journal = {Journal of Biomechanics}, number = {14}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-2380}, doi = {10.1016/j.jbiomech.2012.07.008}, pages = {2382 -- 2386}, year = {2012}, abstract = {The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze-thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze-thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines.}, language = {en} } @article{KotliarLanzl2011, author = {Kotliar, Konstantin and Lanzl, Ines M.}, title = {Can vascular function be assessed by the interpretation of retinal vascular diameter changes?}, series = {Investigative Ophthalmology \& Visual Science, IOVS. 52 (2011), H. 1}, journal = {Investigative Ophthalmology \& Visual Science, IOVS. 52 (2011), H. 1}, publisher = {ARVO}, address = {Rockville, Md.}, isbn = {0146-0404}, pages = {635 -- 636}, year = {2011}, language = {en} } @article{KotliarMueckeVilseretal.2008, author = {Kotliar, Konstantin and M{\"u}cke, Bruno and Vilser, Walthard and Schilling, Rudolf}, title = {Effect of aging on retinal artery blood column diameter measured along the vessel axis / Kotliar, Konstantin E. ; M{\"u}cke, Bruno ; Vilser, Walthard ; Schilling, Rudolf ; Lanzl, Ines M.}, series = {Investigative Ophthalmology \& Visual Science, IOVS. 49 (2008), H. 5}, journal = {Investigative Ophthalmology \& Visual Science, IOVS. 49 (2008), H. 5}, publisher = {-}, isbn = {0146-0404}, pages = {2094 -- 2102}, year = {2008}, language = {en} } @article{KotliarLanzlHanssenetal.2012, author = {Kotliar, Konstantin and Lanzl, Ines M. and Hanssen, Henner and Eberhardt, Karla and Vilser, Walthard and Halle, Martin and Heemann, Uwe and Schmidt-Trucks{\"a}ss, Arno and Baumann, Marcus}, title = {Does increased blood pressure rather than aging influence retinal pulse wave velocity?}, series = {Investigative Ophthalmology \& Visual Science, IOVS}, volume = {53}, journal = {Investigative Ophthalmology \& Visual Science, IOVS}, number = {4}, publisher = {ARVO}, address = {Rockville, Md.}, issn = {0146-0404}, doi = {10.1167/iovs.11-8815}, pages = {2119 -- 2126}, year = {2012}, abstract = {Purpose: It was demonstrated previously that retinal pulse wave velocity (rPWV) as a measure of retinal arterial stiffness is increased in aged anamnestically healthy volunteers compared with young healthy subjects. Using novel methodology of rPWV assessment this finding was confirmed and investigated whether it might relate to the increased blood pressure usually accompanying the aging process, rather than to the aging itself. Methods: A total of 12 young 25.5-year-old (24.0-28.8) [median(1st quartile-3rd quartile)] and 12 senior 68.5-year-old (63.8-71.8) anamnestically healthy volunteers; and 12 senior 63.0-year-old (60.8-65.0) validated healthy volunteers and 12 young 33.0-year-old (29.5-35.0) hypertensive patients were examined. Time-dependent alterations of vessel diameter were assessed by the Dynamic Vessel Analyzer in a retinal artery of each subject. The data were filtered and processed using mathematical signal analysis and rPWVs were calculated. Results: rPWV amounted to 1200 (990-1470) RU (relative units)/s in the hypertensive group and to 1040 (700-2230) RU/s in anamnestically healthy seniors. These differed significantly from rPWVs in young healthy group (410 [280-500] RU/s) and in validated healthy seniors (400 [320-510] RU/s). rPWV associated with age and mean arterial pressure (MAP) in the pooled cohort excluded validated healthy seniors. In a regression model these associations remain when alternately adjusted for MAP and age. When including validated healthy seniors in the pooled cohort only association with MAP remains. Conclusions: Both aging (with not excluded cardiovascular risk factors) and mild hypertension are associated with elevated rPWV. rPWV increases to a similar extent both in young mildly hypertensive subjects and in aged anamnestically healthy persons. Healthy aging is not associated with increased rPWV.}, language = {en} } @article{LustfeldPithanReissel2012, author = {Lustfeld, H. and Pithan, C. and Reißel, Martin}, title = {Metallic electrolyte composites in the framework of the brick-layer model}, series = {Journal of the European Ceramic Society}, volume = {32}, journal = {Journal of the European Ceramic Society}, number = {4}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0955-2219}, doi = {10.1016/j.jeurceramsoc.2011.10.017}, pages = {859 -- 864}, year = {2012}, abstract = {It is well known that the already large dielectric constants of some electrolytes like BaTiO₃ can be enhanced further by adding metallic (e.g. Ni, Cu or Ag) nanoparticles. The enhancement can be quite large, a factor of more than 1000 is possible. The consequences for the properties will be discussed in the present paper applying a brick-layer model (BLM) for calculating dc-resistivities of thin layers and a modified one (PBLM) that includes percolation for calculating dielectric properties of these materials. The PBLM results in an at least qualitative description and understanding of the physical phenomena: This model gives an explanation for the steep increase of the dielectric constant below the percolation threshold and why this increase is connected to a dramatic decrease of the breakdown voltage as well as the ability of storing electrical energy. We conclude that metallic electrolyte composites like BaTiO₃ are not appropriate for energy storage.}, language = {en} } @article{KernSchelthoffMathieu2012, author = {Kern, Alexander and Schelthoff, Christof and Mathieu, Moritz}, title = {Detaillierte Berechnung der Einfangwirksamkeiten von Fangeinrichtungen}, series = {Elektro-Praktiker}, volume = {66}, journal = {Elektro-Praktiker}, number = {4}, publisher = {Huss Medien}, address = {Berlin}, issn = {0013-5569}, pages = {6 Seiten}, year = {2012}, abstract = {Im Beitrag wird zun{\"a}chst das Verfahren eines dynamischen elektro-geometrischen Modells vorgestellt. Dieses arbeitet im Gegensatz zum klassischen Blitzkugel-Verfahren nicht mit konstanten Radien; vielmehr wird der Radius der Blitzkugel variiert. Dabei werden ausschließlich vorhandene und in internationalen Normen anerkannte Ergebnisse, blitzphysikalische Grundlagen und Untersuchungen verwendet, und auf deren Grundlage ein numerisches Verfahren erarbeitet. Mit dem dynamischen elektro-geometrischen Modell werden dann einige Beispiele des Schutzes mit Fangstangen, die gem{\"a}ß dem klassischen Blitzkugel-Verfahren nach DIN EN 62305-3 f{\"u}r die Schutzklassen I - II - III - IV geplant sind, untersucht. Es wird gezeigt, dass die Einfangwirksamkeiten wesentlich h{\"o}her sind als in der Normenreihe DIN EN 62305 selbst angegeben. Grund daf{\"u}r ist die Tatsache, dass das Blitzkugel-Verfahren sehr konservativ aufgebaut ist und dem Planer von Blitzschutzsystemen nur die m{\"o}glichen Stellen f{\"u}r einen Einschlag aufzeigt, ohne eine Bewertung der Einschlagsh{\"a}ufigkeit zu liefern. Andererseits bedeutet dies jedoch, dass man mit dem klassischen Blitzkugel-Verfahren stets auf der „sicheren Seite" liegt.}, language = {de} } @article{BohrnStuetzFuchsetal.2012, author = {Bohrn, U. and St{\"u}tz, E. and Fuchs, K. and Fleischer, M. and Sch{\"o}ning, Michael Josef and Wagner, P.}, title = {Monitoring of irritant gas using a whole-cell-based sensor system}, series = {Sensors and Actuators B: Chemical}, volume = {175}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2012.05.088}, pages = {208 -- 217}, year = {2012}, abstract = {Cell-based sensors for the detection of gases have long been underrepresented, due to the cellular requirement of being cultured in a liquid environment. In this work we established a cell-based gas biosensor for the detection of toxic substances in air, by adapting a commercial sensor chip (Bionas®), previously used for the measurement of pollutants in liquids. Cells of the respiratory tract (A549, RPMI 2650, V79), which survive at a gas phase in a natural context, are used as biological receptors. The physiological cell parameters acidification, respiration and morphology are continuously monitored in parallel. Ammonia was used as a highly water-soluble model gas to test the feasibility of the sensor system. Infrared measurements confirmed the sufficiency of the medium draining method. This sensor system provides a basis for many sensor applications such as environmental monitoring, building technology and public security.}, language = {en} }