@article{HeuermannSchiek1992, author = {Heuermann, Holger and Schiek, Burkhard}, title = {A Generalization of the Txx Network Analyzer Self-Calibration Procedure}, series = {Conference proceedings : monday 24th to thursday 27th august 1992, Helsinki University of Technology, Espoo, Finland ; [the international conference and exhibition designed for the Microwave Community]. Vol. 2}, journal = {Conference proceedings : monday 24th to thursday 27th august 1992, Helsinki University of Technology, Espoo, Finland ; [the international conference and exhibition designed for the Microwave Community]. Vol. 2}, publisher = {Microwave Exhibitions and Publishers}, address = {Tunbridge Wells}, isbn = {0-946821-77-1}, pages = {907 -- 912}, year = {1992}, language = {en} } @article{HeuermannSchiek1997, author = {Heuermann, Holger and Schiek, B.}, title = {15-term self-calibration methods for the error-correction of on-wafer measurements}, series = {IEEE transactions on instrumentation and measurement : IM / Institute of Electrical and Electronics Engineers, Instrumentation and Measurement Group. 46 (1997), H. 5}, journal = {IEEE transactions on instrumentation and measurement : IM / Institute of Electrical and Electronics Engineers, Instrumentation and Measurement Group. 46 (1997), H. 5}, isbn = {0018-9456}, pages = {1105 -- 1110}, year = {1997}, language = {en} } @article{WolfLuczakSpringeretal.1997, author = {Wolf, Martin R. and Luczak, Holger and Springer, J. and Simon, S.}, title = {The role of metaphors in computer supported cooperative work}, series = {Proceedings of WWDU '97 Tokyo, Fifth International Scientific Conference on Work with Display Units : November 3 - 5, 1997, Tokyo /}, journal = {Proceedings of WWDU '97 Tokyo, Fifth International Scientific Conference on Work with Display Units : November 3 - 5, 1997, Tokyo /}, editor = {Miyamoto, Hiroyuki}, publisher = {-}, address = {Tokyo}, pages = {191 -- 192}, year = {1997}, language = {en} } @article{SteinbauerFerrein2016, author = {Steinbauer, Gerald and Ferrein, Alexander}, title = {20 Years of RoboCup}, series = {KI - K{\"u}nstliche Intelligenz}, volume = {30}, journal = {KI - K{\"u}nstliche Intelligenz}, number = {3-4}, publisher = {Springer}, address = {Berlin}, issn = {1610-1987}, doi = {10.1007/s13218-016-0442-z}, pages = {221 -- 224}, year = {2016}, language = {en} } @article{FerreinFritzLakemeyer2003, author = {Ferrein, Alexander and Fritz, Christian and Lakemeyer, Gerhard}, title = {Extending DTGOLOG with Options / Ferrein, Alexander ; Fritz, Christian ; Lakemeyer, Gerhard}, series = {IJCAI-03, Proceedings of the Eighteenth International Joint Conference on Artificial Intelligence, Acapulco, Mexico, August 9-15, 2003}, journal = {IJCAI-03, Proceedings of the Eighteenth International Joint Conference on Artificial Intelligence, Acapulco, Mexico, August 9-15, 2003}, pages = {1391 -- 1393}, year = {2003}, language = {en} } @article{BragardSoltauThomasetal.2010, author = {Bragard, Michael and Soltau, N. and Thomas, S. and De Doncker, R. W.}, title = {The balance of renewable sources and user demands in grids : power electronics for modular battery energy storage systems}, series = {IEEE transactions on power electronics}, volume = {25}, journal = {IEEE transactions on power electronics}, number = {12}, publisher = {IEEE}, address = {New York}, issn = {0885-8993}, doi = {10.1109/TPEL.2010.2085455}, pages = {3049 -- 3056}, year = {2010}, abstract = {The continuously growing amount of renewable sources starts compromising the stability of electrical grids. Contradictory to fossil fuel power plants, energy production of wind and photovoltaic (PV) energy is fluctuating. Although predictions have significantly improved, an outage of multi-MW offshore wind farms poses a challenging problem. One solution could be the integration of storage systems in the grid. After a short overview, this paper focuses on two exemplary battery storage systems, including the required power electronics. The grid integration, as well as the optimal usage of volatile energy reserves, is presented for a 5- kW PV system for home application, as well as for a 100- MW medium-voltage system, intended for wind farm usage. The efficiency and cost of topologies are investigated as a key parameter for large-scale integration of renewable power at medium- and low-voltage.}, language = {en} } @article{KoellenspergerBragardPlumetal.2009, author = {K{\"o}llensperger, P. and Bragard, Michael and Plum, T. and De Doncker, R. W.}, title = {The dual GCT : new high-power device using optimized GCT technology}, series = {IEEE transactions on industry applications}, volume = {45}, journal = {IEEE transactions on industry applications}, number = {5}, issn = {0093-9994}, doi = {10.1109/TIA.2009.2027364}, pages = {1754 -- 1762}, year = {2009}, language = {en} } @article{WindmuellerSchapsZantisetal.2024, author = {Windm{\"u}ller, Anna and Schaps, Kristian and Zantis, Frederik and Domgans, Anna and Taklu, Bereket Woldegbreal and Yang, Tingting and Tsai, Chih-Long and Schierholz, Roland and Yu, Shicheng and Kungl, Hans and Tempel, Hermann and Dunin-Borkowski, Rafal E. and H{\"u}ning, Felix and Hwang, Bing Joe and Eichel, R{\"u}diger-A.}, title = {Electrochemical activation of LiGaO2: implications for ga-doped garnet solid electrolytes in li-metal batteries}, series = {ACS Applied Materials \& Interfaces}, volume = {16}, journal = {ACS Applied Materials \& Interfaces}, number = {30}, publisher = {ACS Publications}, address = {Washington, DC}, issn = {39181-3919}, doi = {10.1021/acsami.4c03729}, pages = {14 Seiten}, year = {2024}, abstract = {Ga-doped Li7La3Zr2O12 garnet solid electrolytes exhibit the highest Li-ion conductivities among the oxide-type garnet-structured solid electrolytes, but instabilities toward Li metal hamper their practical application. The instabilities have been assigned to direct chemical reactions between LiGaO2 coexisting phases and Li metal by several groups previously. Yet, the understanding of the role of LiGaO2 in the electrochemical cell and its electrochemical properties is still lacking. Here, we are investigating the electrochemical properties of LiGaO2 through electrochemical tests in galvanostatic cells versus Li metal and complementary ex situ studies via confocal Raman microscopy, quantitative phase analysis based on powder X-ray diffraction, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, and electron energy loss spectroscopy. The results demonstrate considerable and surprising electrochemical activity, with high reversibility. A three-stage reaction mechanism is derived, including reversible electrochemical reactions that lead to the formation of highly electronically conducting products. The results have considerable implications for the use of Ga-doped Li7La3Zr2O12 electrolytes in all-solid-state Li-metal battery applications and raise the need for advanced materials engineering to realize Ga-doped Li7La3Zr2O12for practical use.}, language = {en} } @article{OrzadaSolbachGratzetal.2019, author = {Orzada, Stephan and Solbach, Klaus and Gratz, Marcel and Brunheim, Sascha and Fiedler, Thomas M. and Johst, S{\"o}ren and Bitz, Andreas and Shooshtary, Samaneh and Abuelhaija, Ashraf and Voelker, Maximilian N. and Rietsch, Stefan H. G. and Kraff, Oliver and Maderwald, Stefan and Fl{\"o}ser, Martina and Oehmingen, Mark and Quick, Harald H. and Ladd, Mark E.}, title = {A 32-channel parallel transmit system add-on for 7T MRI}, series = {Plos one}, journal = {Plos one}, doi = {10.1371/journal.pone.0222452}, year = {2019}, language = {en} } @article{OrzadaBitzJohstetal.2017, author = {Orzada, Stephan and Bitz, Andreas and Johst, S{\"o}ren and Gratz, Marcel and V{\"o}lker, Maximilian N. and Kraff, Oliver and Abuelhaija, Ashraf and Fiedler, Thomas M. and Solbach, Klaus and Quick, Harald H. and Ladd, Mark E.}, title = {Analysis of an integrated 8-Channel Tx/Rx body array for use as a body coil in 7-Tesla MRI}, series = {Frontiers in Physics}, volume = {5}, journal = {Frontiers in Physics}, number = {Jun}, issn = {2296-424X}, doi = {10.3389/fphy.2017.00017}, year = {2017}, language = {en} } @article{SchollPalmLehmannetal.1998, author = {Scholl, Ingrid and Palm, Christoph and Lehmann, Thomas Martin and Spitzer, Klaus}, title = {Quantitative Farbmessung in laryngoskopischen Bildern. Palm, C; Scholl, I; Lehmann, TM; Spitzer, K.}, series = {Bildverarbeitung f{\"u}r die Medizin 1998. Hrsg.: Thomas Lehmann ...}, journal = {Bildverarbeitung f{\"u}r die Medizin 1998. Hrsg.: Thomas Lehmann ...}, publisher = {Springer}, address = {Berlin}, isbn = {3-540-63885-7}, pages = {412 -- 416}, year = {1998}, language = {en} } @article{FiedlerLaddBitz2017, author = {Fiedler, Thomas M. and Ladd, Mark E. and Bitz, Andreas}, title = {RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus temperature limits}, series = {Medical Physics}, volume = {44}, journal = {Medical Physics}, number = {1}, doi = {10.1002/mp.12034}, pages = {143 -- 157}, year = {2017}, language = {en} } @article{DieringerRenzLindeletal.2011, author = {Dieringer, Matthias A. and Renz, Wolfgang and Lindel, Tomasz Dawid and Seifert, Frank and Frauenrath, Tobias and von Knobelsdorf-Brenkenhoff, Florian and Waiczies, Helmar and Hoffmann, Werner and Rieger, Jan and Pfeiffer, Harald and Ittermann, Bernd and Schulz-Menger, Jeanette and Niendorf, Thoralf}, title = {Design and application of a four-channel transmit/receive surface coil for functional cardiac imaging at 7T}, series = {Journal of Magnetic Resonance Imaging}, volume = {33}, journal = {Journal of Magnetic Resonance Imaging}, number = {3}, publisher = {Wiley-Liss}, address = {New York}, issn = {1522-2586}, doi = {10.1002/jmri.22451}, pages = {736 -- 741}, year = {2011}, abstract = {Purpose To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T. Materials and Methods A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3. Results Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach. Conclusion A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated.}, language = {en} } @article{FiedlerLaddClemensetal.2020, author = {Fiedler, Thomas M. and Ladd, Mark E. and Clemens, Markus and Bitz, Andreas}, title = {Safety of subjects during radiofrequency exposure in ultra-high-field magnetic resonance imaging}, series = {IEEE Letters on Electromagnetic Compatibility Practice and Applications}, volume = {2}, journal = {IEEE Letters on Electromagnetic Compatibility Practice and Applications}, number = {3}, publisher = {IEEE}, address = {New York, NY}, isbn = {2637-6423}, doi = {10.1109/LEMCPA.2020.3029747}, pages = {1 -- 8}, year = {2020}, abstract = {Magnetic resonance imaging (MRI) is one of the most important medical imaging techniques. Since the introduction of MRI in the mid-1980s, there has been a continuous trend toward higher static magnetic fields to obtain i.a. a higher signal-to-noise ratio. The step toward ultra-high-field (UHF) MRI at 7 Tesla and higher, however, creates several challenges regarding the homogeneity of the spin excitation RF transmit field and the RF exposure of the subject. In UHF MRI systems, the wavelength of the RF field is in the range of the diameter of the human body, which can result in inhomogeneous spin excitation and local SAR hotspots. To optimize the homogeneity in a region of interest, UHF MRI systems use parallel transmit systems with multiple transmit antennas and time-dependent modulation of the RF signal in the individual transmit channels. Furthermore, SAR increases with increasing field strength, while the SAR limits remain unchanged. Two different approaches to generate the RF transmit field in UHF systems using antenna arrays close and remote to the body are investigated in this letter. Achievable imaging performance is evaluated compared to typical clinical RF transmit systems at lower field strength. The evaluation has been performed under consideration of RF exposure based on local SAR and tissue temperature. Furthermore, results for thermal dose as an alternative RF exposure metric are presented.}, language = {en} }