@inproceedings{MahdiRendonSchwageretal.2019, author = {Mahdi, Zahra and Rend{\´o}n, Carlos and Schwager, Christian and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Novel concept for indirect solar-heated methane reforming}, series = {AIP Conference Proceedings}, volume = {2126}, booktitle = {AIP Conference Proceedings}, publisher = {AIP Publishing}, address = {Melville, NY}, issn = {0094-243X}, doi = {10.1063/1.5117694}, pages = {180014-1 -- 180014-7}, year = {2019}, language = {en} } @inproceedings{AugensteinHerbergsKuperjans2005, author = {Augenstein, Eckardt and Herbergs, S. and Kuperjans, Isabel}, title = {TOP-Energy : softwaregest{\"u}tzte Analyse und Optimierung industrieller Energieversorgungssysteme ; Postershow}, series = {Optimierung in der Energiewirtschaft : Tagung Stuttgart, 27. und 28. Oktober 2005. - (VDI-Berichte ; 1908)}, booktitle = {Optimierung in der Energiewirtschaft : Tagung Stuttgart, 27. und 28. Oktober 2005. - (VDI-Berichte ; 1908)}, publisher = {VDI-Verl.}, address = {D{\"u}sseldorf}, isbn = {3-18-091908-6}, pages = {279 -- 282}, year = {2005}, language = {de} } @inproceedings{PauksztatKuperjansdeHesselle2006, author = {Pauksztat, Anja and Kuperjans, Isabel and de Hesselle, M.}, title = {Referenzformeln f{\"u}r Energiebedarf und CO2-Emissionen in der Glasindustrie}, series = {Energieeffizienz - Chancen f{\"u}r die Zukunft : Tagung Berlin, 14. und 15. November 2006. - (VDI-Berichte ; 1951)}, booktitle = {Energieeffizienz - Chancen f{\"u}r die Zukunft : Tagung Berlin, 14. und 15. November 2006. - (VDI-Berichte ; 1951)}, edition = {Nichtred. Ms.-Dr.}, publisher = {VDI-Verl.}, address = {D{\"u}sseldorf}, isbn = {3-18-091951-5}, pages = {179 -- 190}, year = {2006}, language = {de} } @inproceedings{GeimerSauerbornHoffschmidtetal.2010, author = {Geimer, Konstantin and Sauerborn, Markus and Hoffschmidt, Bernhard and Schmitz, Mark and G{\"o}ttsche, Joachim}, title = {Test facility for absorber specimens of solar tower power plants}, series = {Advances in Science and Technology}, volume = {74}, booktitle = {Advances in Science and Technology}, publisher = {Trans Tech Publications}, address = {Baech}, doi = {10.4028/www.scientific.net/AST.74.266}, pages = {266 -- 271}, year = {2010}, abstract = {The Solar-Institute J{\"u}lich (SIJ) has initiated the construction of the first and only German solar tower power plant and is now involved in the accompanying research. The power plant for experimental and demonstration purposes in the town of J{\"u}lich started supplying electric energy in the beginning of 2008. The central receiver plant features as central innovation an open volumetric receiver, consisting of porous ceramic elements that simultaneously absorb the concentrated sunlight and transfer the heat to ambient air passing through the pores so that an average temperature of 680°C is reached. The subsequent steam cycle generates up to 1.5 MWe. A main field of research at the SIJ is the optimization of the absorber structures. To analyze the capability of new absorber specimens a special test facility was developed and set up in the laboratory. A high-performance near-infrared radiator offers for single test samples a variable and repeatable beam with a power of up to 320 kW/m² peak. The temperatures achieved on the absorber surface can reach more than 1000°C. To suck ambient air through the open absorber - like on the tower - it is mounted on a special blower system. An overview about the test facility and some recent results will be presented.}, language = {en} } @inproceedings{BouquegneauKernRousseau2010, author = {Bouquegneau, Christian and Kern, Alexander and Rousseau, Alain}, title = {Lightning safety guidelines}, pages = {6 Seiten}, year = {2010}, abstract = {This paper introduces lightning to the layman, noting the right behaviour in front of thunderstorms as well as protective measures against lightning. It also contributes to the prevention of lightning injuries and damages. This report was prepared by the authors inside the AHG1 Group for IEC TC81 (Lightning Protection).}, language = {en} } @inproceedings{KernFrentzelBehrens2010, author = {Kern, Alexander and Frentzel, Ralf and Behrens, J{\"o}rg}, title = {Simulation of the transient voltages in the auxiliary power network of a large power plant in case of a direct lightning strike to the high-voltage overhead transmission line}, publisher = {IEEE}, address = {New York}, isbn = {978-88-905519-0-1}, doi = {10.1109/ICLP.2010.7845756}, pages = {749-1 -- 749-7}, year = {2010}, abstract = {Large power plants can be endangered by lightning strikes with possible consequences regarding their safety and availability. A special scenario is a lightning strike to the HV overhead transmission line close to the power plant's connection to the power grid. If then additionally a so-called shielding failure of the overhead ground wire on top of the overhead transmission line is assumed, i.e. the lightning strikes directly into a phase conductor, this is an extreme electromagnetic disturbance. The paper deals with the numerical simulation of such a lightning strike and the consequences on the components of the power plant's auxiliary power network connected to different voltage levels.}, language = {en} } @inproceedings{KernSchelthoffMathieu2010, author = {Kern, Alexander and Schelthoff, Christof and Mathieu, Moritz}, title = {Probability of lightning strikes to air-terminations of structures using the electro-geometrical model theory and the statistics of lightning current parameters}, publisher = {IEEE}, address = {New York}, isbn = {978-88-905519-0-1}, doi = {10.1109/ICLP.2010.7845757}, pages = {750-1 -- 750-8}, year = {2010}, abstract = {Planning the air-terminations for a structure to be protected the use of the rolling-sphere method (electro-geometrical model) is the best way from the physics of lightning point-of-view. Therefore, international standards prefer this method. However, using the rolling-sphere method only results in possible point-of-strikes on a structure without giving information about the probability of strikes at the individual points compared to others.}, language = {en} } @inproceedings{SattlerAttiAlexopoulosetal.2022, author = {Sattler, Johannes Christoph and Atti, Vikrama Naga Babu and Alexopoulos, Spiros and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf and Dutta, Siddharth and Kioutsioukis, Ioannis}, title = {DNI forecast tool for the smart operation of a parabolic trough collector system with concrete thermal energy storage: Theory, results and outlook}, series = {SolarPACES 2022 conference proceedings}, booktitle = {SolarPACES 2022 conference proceedings}, number = {1}, publisher = {TIB Open Publishing}, address = {Hannover}, issn = {2751-9899 (online)}, doi = {10.52825/solarpaces.v1i.731}, pages = {9 Seiten}, year = {2022}, abstract = {This work presents a basic forecast tool for predicting direct normal irradiance (DNI) in hourly resolution, which the Solar-Institut J{\"u}lich (SIJ) is developing within a research project. The DNI forecast data shall be used for a parabolic trough collector (PTC) system with a concrete thermal energy storage (C-TES) located at the company KEAN Soft Drinks Ltd in Limassol, Cyprus. On a daily basis, 24-hour DNI prediction data in hourly resolution shall be automatically produced using free or very low-cost weather forecast data as input. The purpose of the DNI forecast tool is to automatically transfer the DNI forecast data on a daily basis to a main control unit (MCU). The MCU automatically makes a smart decision on the operation mode of the PTC system such as steam production mode and/or C-TES charging mode. The DNI forecast tool was evaluated using historical data of measured DNI from an on-site weather station, which was compared to the DNI forecast data. The DNI forecast tool was tested using data from 56 days between January and March 2022, which included days with a strong variation in DNI due to cloud passages. For the evaluation of the DNI forecast reliability, three categories were created and the forecast data was sorted accordingly. The result was that the DNI forecast tool has a reliability of 71.4 \% based on the tested days. The result fulfils SIJ's aim to achieve a reliability of around 70 \%, but SIJ aims to still improve the DNI forecast quality.}, language = {en} } @inproceedings{DuranParedesMottaghyHerrmannetal.2020, author = {Duran Paredes, Ludwin and Mottaghy, Darius and Herrmann, Ulf and Groß, Rolf Fritz}, title = {Online ground temperature and soil moisture monitoring of a shallow geothermal system with non-conventional components}, series = {EGU General Assembly 2020}, booktitle = {EGU General Assembly 2020}, year = {2020}, abstract = {We present first results from a newly developed monitoring station for a closed loop geothermal heat pump test installation at our campus, consisting of helix coils and plate heat exchangers, as well as an ice-store system. There are more than 40 temperature sensors and several soil moisture content sensors distributed around the system, allowing a detailed monitoring under different operating conditions.In the view of the modern development of renewable energies along with the newly concepts known as Internet of Things and Industry 4.0 (high-tech strategy from the German government), we created a user-friendly web application, which will connect the things (sensors) with the open network (www). Besides other advantages, this allows a continuous remote monitoring of the data from the numerous sensors at an arbitrary sampling rate.Based on the recorded data, we will also present first results from numerical simulations, taking into account all relevant heat transport processes.The aim is to improve the understanding of these processes and their influence on the thermal behavior of shallow geothermal systems in the unsaturated zone. This will in turn facilitate the prediction of the performance of these systems and therefore yield an improvement in their dimensioning when designing a specific shallow geothermal installation.}, language = {en} } @inproceedings{SattlerChicoCaminosUerlingsetal.2020, author = {Sattler, Johannes Christoph and Chico Caminos, Ricardo Alexander and {\"U}rlings, Nicolas and Dutta, Siddharth and Ruiz, Victor and Kalogirou, Soteris and Ktistis, Panayiotis and Agathokleous, Rafaela and Jung, Christian and Alexopoulos, Spiros and Atti, Vikrama Naga Babu and Teixeira Boura, Cristiano Jos{\´e} and Herrmann, Ulf}, title = {Operational experience and behaviour of a parabolic trough collector system with concrete thermal energy storage for process steam generation in Cyprus}, series = {AIP Conference Proceedings}, booktitle = {AIP Conference Proceedings}, number = {2303}, doi = {10.1063/5.0029278}, pages = {140004-1 -- 140004-10}, year = {2020}, abstract = {As part of the transnational research project EDITOR, a parabolic trough collector system (PTC) with concrete thermal energy storage (C-TES) was installed and commissioned in Limassol, Cyprus. The system is located on the premises of the beverage manufacturer KEAN Soft Drinks Ltd. and its function is to supply process steam for the factory's pasteurisation process [1]. Depending on the factory's seasonally varying capacity for beverage production, the solar system delivers between 5 and 25 \% of the total steam demand. In combination with the C-TES, the solar plant can supply process steam on demand before sunrise or after sunset. Furthermore, the C-TES compensates the PTC during the day in fluctuating weather conditions. The parabolic trough collector as well as the control and oil handling unit is designed and manufactured by Protarget AG, Germany. The C-TES is designed and produced by CADE Soluciones de Ingenier{\´i}a, S.L., Spain. In the focus of this paper is the description of the operational experience with the PTC, C-TES and boiler during the commissioning and operation phase. Additionally, innovative optimisation measures are presented.}, language = {en} } @inproceedings{HardtAbdelGawadMartinetal.1975, author = {Hardt, Arno and Abdel-Gawad, A and Martin, Siegfried A. and Reich, J.}, title = {Design procedures for the Juelich QQDDQ high resolution spectrometer}, series = {Proceedings, 5th International Conference on Magnet Technology (MT-5) : Rome, Italy, April 21-25, 1975}, booktitle = {Proceedings, 5th International Conference on Magnet Technology (MT-5) : Rome, Italy, April 21-25, 1975}, pages = {45 -- 51}, year = {1975}, language = {en} } @inproceedings{MartinBergHardtetal.1979, author = {Martin, Siegfried A. and Berg, G. and Hardt, Arno and H{\"u}rlimann, Werner and K{\"o}hler, M. and Meißberger, J. and Sagefka, Thomas and Schult, Otto W. B.}, title = {First experience with the magnet spectrometer 'BIG KARL'}, series = {Use of magnetic spectrometers in nuclear physics : proceedings of the Daresbury study weekend 10 - 11 March 1979}, booktitle = {Use of magnetic spectrometers in nuclear physics : proceedings of the Daresbury study weekend 10 - 11 March 1979}, editor = {Sanderson, N. E.}, publisher = {Daresbury Lab.}, address = {Daresbury}, pages = {38 -- 42}, year = {1979}, language = {en} } @inproceedings{LuBeyerBosiljkovetal.2016, author = {Lu, S. and Beyer, Katrin and Bosiljkov, V. and Butenweg, Christoph and D'Ayala, D. and Degee, H. and Gams, M. and Klouda, J. and Lagomarsino, S. and Penna, A. and Mojsilovic, N. and da Porto, F. and Sorrentino, L. and Vintzileou, E.}, title = {Next generation of Eurocode 8, masonry chapter}, series = {Brick and Block Masonry Proceedings of the 16th International Brick and Block Masonry Conference, Padova, Italy, 26-30 June 2016}, booktitle = {Brick and Block Masonry Proceedings of the 16th International Brick and Block Masonry Conference, Padova, Italy, 26-30 June 2016}, editor = {Modena, Claudio and da Porto, F. and Valluzzi, M.R.}, publisher = {Taylor \& Francis}, address = {London}, isbn = {978-1-138-02999-6 (Print)}, pages = {695 -- 700}, year = {2016}, abstract = {This paper describes the procedure on the evaluation of the masonry chapter for the next generation of Eurocode 8, the European Standard for earthquake-resistant design. In CEN, TC 250/SC8, working group WG 1 has been established to support the subcommittee on the topic of masonry on both design of new structures (EN1998-1) and assessment of existing structures (EN1998-3). The aim is to elaborate suggestions for amendments which fit the current state of the art in masonry and earthquake-resistant design. Focus will be on modelling, simplified methods, linear-analysis (q-values, overstrength-values), nonlinear procedures, out-of-plane design as well as on clearer definition of limit states. Beside these, topics related to general material properties, reinforced masonry, confined masonry, mixed structures and non-structural infills will be covered too. This paper presents the preliminary work and results up to the submission date.}, language = {en} }