@article{HasanKeilStaatetal.2012, author = {Hasan, Istabrak and Keil, Ludger and Staat, Manfred and Wahl, Gerhard and Bourauel, Christoph}, title = {Determination of the frictional coefficient of the implant-antler interface : experimental approach}, series = {Biomedical Engineering / Biomedizinische Technik}, volume = {57}, journal = {Biomedical Engineering / Biomedizinische Technik}, number = {5}, publisher = {De Gruyter}, address = {Berlin}, issn = {1862-278X}, pages = {359 -- 363}, year = {2012}, abstract = {The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5-0.7 and 0.3-0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens.}, language = {en} } @article{BassamHeschelerTemizArtmannetal.2012, author = {Bassam, Rasha and Hescheler, J{\"u}rgen and Temiz Artmann, Ayseg{\"u}l and Artmann, Gerhard and Digel, Ilya}, title = {Effects of spermine NONOate and ATP on the thermal stability of hemoglobin}, series = {BMC Biophysics}, volume = {5}, journal = {BMC Biophysics}, publisher = {BioMed Central}, address = {London}, issn = {2046-1682}, doi = {10.1186/2046-1682-5-16}, year = {2012}, abstract = {Background Minor changes in protein structure induced by small organic and inorganic molecules can result in significant metabolic effects. The effects can be even more profound if the molecular players are chemically active and present in the cell in considerable amounts. The aim of our study was to investigate effects of a nitric oxide donor (spermine NONOate), ATP and sodium/potassium environment on the dynamics of thermal unfolding of human hemoglobin (Hb). The effect of these molecules was examined by means of circular dichroism spectrometry (CD) in the temperature range between 25°C and 70°C. The alpha-helical content of buffered hemoglobin samples (0.1 mg/ml) was estimated via ellipticity change measurements at a heating rate of 1°C/min. Results Major results were: 1) spermine NONOate persistently decreased the hemoglobin unfolding temperature T u irrespectively of the Na + /K + environment, 2) ATP instead increased the unfolding temperature by 3°C in both sodium-based and potassium-based buffers and 3) mutual effects of ATP and NO were strongly influenced by particular buffer ionic compositions. Moreover, the presence of potassium facilitated a partial unfolding of alpha-helical structures even at room temperature. Conclusion The obtained data might shed more light on molecular mechanisms and biophysics involved in the regulation of protein activity by small solutes in the cell.}, language = {en} } @article{Grotendorst2012, author = {Grotendorst, Johannes}, title = {Supercomputer programmieren - ein besonderes Studienangebot in J{\"u}lich}, series = {Junge Wissenschaft}, volume = {27}, journal = {Junge Wissenschaft}, number = {94}, publisher = {Verlag Junge Wissenschaft}, address = {D{\"u}sseldorf}, isbn = {0179-8529}, pages = {12 -- 14}, year = {2012}, language = {de} } @article{Grotendorst2012, author = {Grotendorst, Johannes}, title = {IAS Winter School: Hierarchical Methods for Dynamics in Complex Molecular Systems}, series = {Innovatives Supercomputing in Deutschland : inSiDE}, volume = {10}, journal = {Innovatives Supercomputing in Deutschland : inSiDE}, pages = {104 -- 1}, year = {2012}, language = {en} } @article{MansurovJandosovKerimkulovaetal.2014, author = {Mansurov, Zulkhair A. and Jandosov, J. M. and Kerimkulova, Almagul R. and Azat, Seitkhan and Zhubanova, Azhar Achmet and Digel, Ilya and Savistkaya, I. S. and Akimbekov, Nuraly S. and Kistaubaeva, A. S.}, title = {Nanostructured carbon materials for biomedical use}, series = {Eurasian chemico-technological journal : quarterly journal of the International Higher Education Academy of Sciences}, volume = {15 (2013)}, journal = {Eurasian chemico-technological journal : quarterly journal of the International Higher Education Academy of Sciences}, number = {3}, publisher = {Institute of Combustion Problems}, address = {Almaty}, issn = {1562-3920}, doi = {10.18321/ectj224}, pages = {209 -- 217}, year = {2014}, abstract = {One of the priority trends of carbon nanotechnology is creation of nanocomposite systems. Such carbon nanostructured composites were produced using - raw materials based on the products of agricultural waste, such as grape stones, apricot stones, rice husk. These products have a - wide spectrum of application and can be obtained in large quantities. The Institute of Combustion Problems has carried out the work on synthesis of the nanostructured carbon sorbents for multiple applications including the field of biomedicine. The article presents the data on the synthesis and physico-chemical properties of carbonaceous sorbents using physicochemical methods of investigation: separation and purification of biomolecules; isolation of phytohormone - fusicoccin; adsorbent INGO-1 in the form of an adsorption column for blood detoxification, oral (entero) sorbent - INGO-2; the study of efferent and probiotic properties and sorption activity in regard to the lipopolysaccharide (LPS), new biocomposites - based on carbonized rice husk (CRH) and cellular microorganisms; the use of CRH in wound treatment. A new material for blood detoxication (INGO-1) has been obtained. Adsorption of p-cresyl sulfate and indoxyl sulfate has shown that active carbon adsorbent can remove clinically significant level of p-cresyl sulfate and indoxyl sulfate from human plasma. Enterosorbent INGO-2 possesses high adsorption activity in relation to Gram-negative bacteria and their endotoxins. INGO-2 slows down the growth of conditionally pathogenic microorganisms, without having a negative effect on bifido and lactobacteria. The use of enterosorbent INGO-2 for sorption therapy may provide a solution to a complex problem - detoxication of the digestive tract and normalization of the intestinal micro ecology. The immobilized probiotic called "Riso-lact" was registered at the Ministry of Health of the Republic of Kazakhstan as a biologically active food additive. The developed technology is patented and provides production of the medicine in the form of freeze-dried biomass immobilized in vials.}, language = {en} } @article{StaatVu2012, author = {Staat, Manfred and Vu, Duc Khoi}, title = {Limit analysis of flaws in pressurized pipes and cylindrical vessels Part II: Circumferential defects}, series = {Engineering Fracture Mechanic}, volume = {97}, journal = {Engineering Fracture Mechanic}, number = {1}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0013-7944}, doi = {10.1016/j.engfracmech.2012.05.017}, pages = {314 -- 333}, year = {2012}, abstract = {Upper and lower bound theorems of limit analyses have been presented in part I of the paper. Part II starts with the finite element discretization of these theorems and demonstrates how both can be combined in a primal-dual optimization problem. This recently proposed numerical method is used to guide the development of a new class of closed-form limit loads for circumferential defects, which show that only large defects contribute to plastic collapse with a rapid loss of strength with increasing crack sizes. The formulae are compared with primal-dual FEM limit analyses and with burst tests. Even closer predictions are obtained with iterative limit load solutions for the von Mises yield function and for the Tresca yield function. Pressure loading of the faces of interior cracks in thick pipes reduces the collapse load of circumferential defects more than for axial flaws. Axial defects have been treated in part I of the paper.}, language = {en} } @inproceedings{KirchnerHenkelNaetheretal.2008, author = {Kirchner, Patrick and Henkel, H. and N{\"a}ther, Niko and Spelthahn, H. and Schneider, A. and Berger, J{\"o}rg and Kolstad, J. and Friedrich, P. and Sch{\"o}ning, Michael Josef}, title = {RFID-basiertes Sensorsystem zur Realisierung intelligenter Verpackungen f{\"u}r die Nahrungsmittelindustrie}, series = {KMU - innovativ: IKT 2008. CD-ROM : BMBF-Statustagung KMU - innovativ: IKT, Darmstadt, 17. - 18. Nov. 2008}, booktitle = {KMU - innovativ: IKT 2008. CD-ROM : BMBF-Statustagung KMU - innovativ: IKT, Darmstadt, 17. - 18. Nov. 2008}, number = {CD-ROM-Ausg.}, publisher = {BMBF}, address = {Berlin}, pages = {9 S.}, year = {2008}, language = {de} } @article{BrockhausBehbahaniMurisetal.2021, author = {Brockhaus, Moritz K. and Behbahani, Mehdi and Muris, Farina and Jansen, Sebastian V. and Schmitz-Rode, Thomas and Steinseifer, Ulrich and Clauser, Johanna C.}, title = {In vitro thrombogenicity testing of pulsatile mechanical circulatory support systems: Design and proof-of-concept}, series = {Artificial Organs}, volume = {45}, journal = {Artificial Organs}, number = {12}, publisher = {Wiley}, address = {Weinheim}, issn = {1525-1594}, doi = {10.1111/aor.14046}, pages = {1513 -- 1521}, year = {2021}, abstract = {Thrombogenic complications are a main issue in mechanical circulatory support (MCS). There is no validated in vitro method available to quantitatively assess the thrombogenic performance of pulsatile MCS devices under realistic hemodynamic conditions. The aim of this study is to propose a method to evaluate the thrombogenic potential of new designs without the use of complex in-vivo trials. This study presents a novel in vitro method for reproducible thrombogenicity testing of pulsatile MCS systems using low molecular weight heparinized porcine blood. Blood parameters are continuously measured with full blood thromboelastometry (ROTEM; EXTEM, FIBTEM and a custom-made analysis HEPNATEM). Thrombus formation is optically observed after four hours of testing. The results of three experiments are presented each with two parallel loops. The area of thrombus formation inside the MCS device was reproducible. The implantation of a filter inside the loop catches embolizing thrombi without a measurable increase of platelet activation, allowing conclusions of the place of origin of thrombi inside the device. EXTEM and FIBTEM parameters such as clotting velocity (α) and maximum clot firmness (MCF) show a total decrease by around 6\% with a characteristic kink after 180 minutes. HEPNATEM α and MCF rise within the first 180 minutes indicate a continuously increasing activation level of coagulation. After 180 minutes, the consumption of clotting factors prevails, resulting in a decrease of α and MCF. With the designed mock loop and the presented protocol we are able to identify thrombogenic hot spots inside a pulsatile pump and characterize their thrombogenic potential.}, language = {en} } @article{ReisertHenkelSchneideretal.2009, author = {Reisert, Steffen and Henkel, H. and Schneider, A. and Sch{\"a}fer, Daniel and Friedrich, P. and Berger, J{\"o}rg and Sch{\"o}ning, Michael Josef}, title = {Entwicklung eines Handheld-Sensorsystems f{\"u}r die „On-line"-Messung der H2O2-Konzentration in aseptischen Entkeimungsprozessen}, series = {9. Dresdner Sensor-Symposium : Dresden, 07.-09. Dezember 2009 / Gerlach, Gerald ; Hauptmann, Peter [Hrsg.]}, journal = {9. Dresdner Sensor-Symposium : Dresden, 07.-09. Dezember 2009 / Gerlach, Gerald ; Hauptmann, Peter [Hrsg.]}, publisher = {TUDpress}, address = {Dresden}, isbn = {978-3-941298-44-6}, pages = {285 -- 288}, year = {2009}, language = {de} } @article{KirchnerSpelthahnSchoeningetal.2010, author = {Kirchner, Patrick and Spelthahn, H. and Sch{\"o}ning, Michael Josef and Henkel, H. and Schneider, A. and Friedrich, P. and Kolstad, J. and Berger, J{\"o}rg}, title = {Realisierung eines Polyimid-basierten kalorimetrischen Gassensors zur Inline-{\"U}berwachung der H2O2-Konzentration in aseptischen Abf{\"u}llanlagen}, series = {Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vortr{\"a}ge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in N{\"u}rnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA)}, journal = {Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vortr{\"a}ge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in N{\"u}rnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA)}, publisher = {VDE Verlag}, address = {Berlin}, isbn = {978-3-8007-3260-9}, pages = {607 -- 612}, year = {2010}, language = {de} } @incollection{PoghossianSchusserBaeckeretal.2015, author = {Poghossian, Arshak and Schusser, Sebastian and B{\"a}cker, Matthias and Leinhos, Marcel and Sch{\"o}ning, Michael Josef}, title = {Real-time in-situ electrical monitoring of the degradation of biopolymers using semiconductor field-effect devices}, series = {Biodegradable biopolymers. Vol. 1}, booktitle = {Biodegradable biopolymers. Vol. 1}, publisher = {Nova Science Publ.}, address = {Hauppauge}, isbn = {978-1-63483-632-6}, pages = {135 -- 153}, year = {2015}, language = {en} } @article{StaeudleSeynnesLapsetal.2022, author = {St{\"a}udle, Benjamin and Seynnes, Olivier and Laps, Guido and Br{\"u}ggemann, Gert-Peter and Albracht, Kirsten}, title = {Altered gastrocnemius contractile behavior in former achilles tendon rupture patients during walking}, series = {Frontiers in Physiology}, volume = {13}, journal = {Frontiers in Physiology}, publisher = {Frontiers Research Foundation}, address = {Lausanne}, issn = {1664-042X}, doi = {10.3389/fphys.2022.792576}, pages = {12 Seiten}, year = {2022}, abstract = {Achilles tendon rupture (ATR) remains associated with functional limitations years after injury. Architectural remodeling of the gastrocnemius medialis (GM) muscle is typically observed in the affected leg and may compensate force deficits caused by a longer tendon. Yet patients seem to retain functional limitations during—low-force—walking gait. To explore the potential limits imposed by the remodeled GM muscle-tendon unit (MTU) on walking gait, we examined the contractile behavior of muscle fascicles during the stance phase. In a cross-sectional design, we studied nine former patients (males; age: 45 ± 9 years; height: 180 ± 7 cm; weight: 83 ± 6 kg) with a history of complete unilateral ATR, approximately 4 years post-surgery. Using ultrasonography, GM tendon morphology, muscle architecture at rest, and fascicular behavior were assessed during walking at 1.5 m⋅s-1 on a treadmill. Walking patterns were recorded with a motion capture system. The unaffected leg served as control. Lower limbs kinematics were largely similar between legs during walking. Typical features of ATR-related MTU remodeling were observed during the stance sub-phases corresponding to series elastic element (SEE) lengthening (energy storage) and SEE shortening (energy release), with shorter GM fascicles (36 and 36\%, respectively) and greater pennation angles (8° and 12°, respectively). However, relative to the optimal fascicle length for force production, fascicles operated at comparable length in both legs. Similarly, when expressed relative to optimal fascicle length, fascicle contraction velocity was not different between sides, except at the time-point of peak series elastic element (SEE) length, where it was 39 ± 49\% lower in the affected leg. Concomitantly, fascicles rotation during contraction was greater in the affected leg during the whole stance-phase, and architectural gear ratios (AGR) was larger during SEE lengthening. Under the present testing conditions, former ATR patients had recovered a relatively symmetrical walking gait pattern. Differences in seen AGR seem to accommodate the profound changes in MTU architecture, limiting the required fascicle shortening velocity. Overall, the contractile behavior of the GM fascicles does not restrict length- or velocity-dependent force potentials during this locomotor task.}, language = {en} } @article{StaeudleSeynnesLapsetal.2021, author = {St{\"a}udle, Benjamin and Seynnes, Olivier and Laps, Guido and G{\"o}ll, Fabian and Br{\"u}ggemann, Gert-Peter and Albracht, Kirsten}, title = {Recovery from achilles tendon repair: a combination of Postsurgery Outcomes and Insufficient remodeling of muscle and tendon}, series = {Medicine \& Science in Sports \& Exercise}, volume = {53}, journal = {Medicine \& Science in Sports \& Exercise}, number = {7}, publisher = {American College of Sports Medicine}, address = {Philadelphia, Pa.}, issn = {1530-0315}, doi = {10.1249/MSS.0000000000002592}, pages = {1356 -- 1366}, year = {2021}, abstract = {Achilles tendon rupture (ATR) patients have persistent functional deficits in the triceps surae muscle-tendon unit (MTU). The complex remodeling of the MTU accompanying these deficits remains poorly understood. The purpose of the present study was to associate in vivo and in silico data to investigate the relations between changes inMTU properties and strength deficits inATR patients. Methods: Elevenmale subjects who had undergone surgical repair of complete unilateral ATR were examined 4.6 ± 2.0 (mean ± SD) yr after rupture. Gastrocnemius medialis (GM) tendon stiffness, morphology, and muscle architecture were determined using ultrasonography. The force-length relation of the plantar flexor muscles was assessed at five ankle joint angles. In addition, simulations (OpenSim) of the GM MTU force-length properties were performed with various iterations of MTU properties found between the unaffected and the affected side. Results: The affected side of the patients displayed a longer, larger, and stiffer GM tendon (13\% ± 10\%, 105\% ± 28\%, and 54\% ± 24\%, respectively) compared with the unaffected side. The GM muscle fascicles of the affected side were shorter (32\% ± 12\%) and with greater pennation angles (31\% ± 26\%). A mean deficit in plantarflexion moment of 31\% ± 10\% was measured. Simulations indicate that pairing an intact muscle with a longer tendon shifts the optimal angular range of peak force outside physiological angular ranges, whereas the shorter muscle fascicles and tendon stiffening seen in the affected side decrease this shift, albeit incompletely. Conclusions: These results suggest that the substantial changes in MTU properties found in ATR patients may partly result from compensatory remodeling, although this process appears insufficient to fully restore muscle function.}, language = {en} } @misc{Digel2010, author = {Digel, Ilya}, title = {In-situ biological decontamination of an ice melting probe}, year = {2010}, language = {en} } @article{KolditzAlbinAbeletal.2016, author = {Kolditz, Melanie and Albin, Thivaharan and Abel, Dirk and Fasse, Alessandro and Br{\"u}ggemann, Gert-Peter and Albracht, Kirsten}, title = {Evaluation of foot position and orientation as manipulated variables to control external knee adduction moments in leg extension training}, series = {Computer methods and programs in biomedicine}, volume = {171}, journal = {Computer methods and programs in biomedicine}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0169-2607}, doi = {10.1016/j.cmpb.2016.09.005}, pages = {81 -- 86}, year = {2016}, abstract = {Background and Objective Effective leg extension training at a leg press requires high forces, which need to be controlled to avoid training-induced damage. In order to avoid high external knee adduction moments, which are one reason for unphysiological loadings on knee joint structures, both training movements and the whole reaction force vector need to be observed. In this study, the applicability of lateral and medial changes in foot orientation and position as possible manipulated variables to control external knee adduction moments is investigated. As secondary parameters both the medio-lateral position of the center of pressure and the frontal-plane orientation of the reaction force vector are analyzed. Methods Knee adduction moments are estimated using a dynamic model of the musculoskeletal system together with the measured reaction force vector and the motion of the subject by solving the inverse kinematic and dynamic problem. Six different foot conditions with varying positions and orientations of the foot in a static leg press are evaluated and compared to a neutral foot position. Results Both lateral and medial wedges under the foot and medial and lateral shifts of the foot can influence external knee adduction moments in the presented study with six healthy subjects. Different effects are observed with the varying conditions: the pose of the leg is changed and the direction and center of pressure of the reaction force vector is influenced. Each effect results in a different direction or center of pressure of the reaction force vector. Conclusions The results allow the conclusion that foot position and orientation can be used as manipulated variables in a control loop to actively control knee adduction moments in leg extension training.}, language = {en} } @article{KaramanidisAlbrachtBraunsteinetal.2011, author = {Karamanidis, Kiros and Albracht, Kirsten and Braunstein, Bjoern and Catala, Maria Moreno and Goldmann, Jan-Peter and Br{\"u}ggemann, Gert-Peter}, title = {Lower leg musculoskeletal geometry and sprint performance}, series = {Gait and Posture}, volume = {34}, journal = {Gait and Posture}, number = {1}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0966-6362}, doi = {10.1016/j.gaitpost.2011.03.009}, pages = {138 -- 141}, year = {2011}, abstract = {The purpose of this study was to investigate whether sprint performance is related to lower leg musculoskeletal geometry within a homogeneous group of highly trained 100-m sprinters. Using a cluster analysis, eighteen male sprinters were divided into two groups based on their personal best (fast: N = 11, 10.30 ± 0.07 s; slow: N = 7, 10.70 ± 0.08 s). Calf muscular fascicle arrangement and Achilles tendon moment arms (calculated by the gradient of tendon excursion versus ankle joint angle) were analyzed for each athlete using ultrasonography. Achilles tendon moment arm, foot and ankle skeletal geometry, fascicle arrangement as well as the ratio of fascicle length to Achilles tendon moment arm showed no significant (p > 0.05) correlation with sprint performance, nor were there any differences in the analyzed musculoskeletal parameters between the fast and slow sprinter group. Our findings provide evidence that differences in sprint ability in world-class athletes are not a result of differences in the geometrical design of the lower leg even when considering both skeletal and muscular components.}, language = {en} } @article{KirchnerOberlaenderFriedrichetal.2010, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Friedrich, Peter and Rysstad, G. and Berger, J{\"o}rg and Keusgen, M. and Sch{\"o}ning, Michael Josef}, title = {Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry}, series = {Procedia Engineering. 5 (2010)}, journal = {Procedia Engineering. 5 (2010)}, isbn = {1877-7058}, pages = {264 -- 267}, year = {2010}, language = {en} } @inproceedings{KolditzAlbrachtFasseetal.2015, author = {Kolditz, Melanie and Albracht, Kirsten and Fasse, Alessandro and Albin, Thivaharan and Br{\"u}ggemann, Gert-Peter and Abel, Dirk}, title = {Evaluation of an industrial robot as a leg press training device}, series = {XV International Symposium on Computer Simulation in Biomechanics July 9th - 11th 2015, Edinburgh, UK}, booktitle = {XV International Symposium on Computer Simulation in Biomechanics July 9th - 11th 2015, Edinburgh, UK}, pages = {41 -- 42}, year = {2015}, language = {en} } @inproceedings{KolditzAlbinFasseetal.2015, author = {Kolditz, Melanie and Albin, Thivaharan and Fasse, Alessandro and Br{\"u}ggemann, Gert-Peter and Abel, Dirk and Albracht, Kirsten}, title = {Simulative Analysis of Joint Loading During Leg Press Exercise for Control Applications}, series = {IFAC-PapersOnLine}, volume = {48}, booktitle = {IFAC-PapersOnLine}, number = {20}, doi = {10.1016/j.ifacol.2015.10.179}, pages = {435 -- 440}, year = {2015}, language = {en} } @inproceedings{BraunsteinGoldmannAlbrachtetal.2013, author = {Braunstein, Bjoern and Goldmann, Jan-Peter and Albracht, Kirsten and Sanno, Maximilian and Willwacher, Steffen and Heinrich, Kai and Herrmann, Volker and Br{\"u}ggemann, Gert-Peter}, title = {Joint specific contribution of mechanical power and work during acceleration and top speed in elite sprinters}, series = {31 International Conference on Biomechanics in Sports, Taipei, Taiwan, July 07 - July 22, 2013}, booktitle = {31 International Conference on Biomechanics in Sports, Taipei, Taiwan, July 07 - July 22, 2013}, issn = {1999-4168}, year = {2013}, language = {en} } @inproceedings{DroszezSannoGoldmannetal.2016, author = {Droszez, Anna and Sanno, Maximilian and Goldmann, Jan-Peter and Albracht, Kirsten and Br{\"u}ggemann, Gert-Peter and Braunstein, Bjoern}, title = {Differences between take-off behavior during vertical jumps and two artistic elements}, series = {34th International Conference of Biomechanics in Sport, Tsukuba, Japan, July 18-22, 2016}, booktitle = {34th International Conference of Biomechanics in Sport, Tsukuba, Japan, July 18-22, 2016}, issn = {1999-4168}, pages = {577 -- 580}, year = {2016}, language = {en} } @inproceedings{KolditzAlbinAlbrachtetal.2016, author = {Kolditz, Melanie and Albin, Thivaharan and Albracht, Kirsten and Br{\"u}ggemann, Gert-Peter and Abel, Dirk}, title = {Isokinematic leg extension training with an industrial robot}, series = {6th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) June 26-29, 2016. UTown, Singapore}, booktitle = {6th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) June 26-29, 2016. UTown, Singapore}, doi = {10.1109/BIOROB.2016.7523750}, pages = {950 -- 955}, year = {2016}, language = {de} } @article{KozhalakovaZhubanovaMansurovetal.2010, author = {Kozhalakova, A. A. and Zhubanova, Azhar A. and Mansurov, Z. A. and Digel, Ilya and Tazhibayeva, S. M. and Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l}, title = {Adsorption of bacterial lipopolysaccharides on carbonized rice shell}, series = {Science of Central Asia}, journal = {Science of Central Asia}, pages = {50 -- 54}, year = {2010}, language = {en} } @article{BelavyAlbrachtBrueggemannetal.2016, author = {Belavy, Daniel L. and Albracht, Kirsten and Br{\"u}ggemann, Gert-Peter and Vergroesen, Pieter-Paul A. and Dieen, Jaap H. van}, title = {Can exercise positively influence the intervertebral disc?}, series = {Sports Medicine}, volume = {46}, journal = {Sports Medicine}, number = {4}, publisher = {Springer}, address = {Berlin}, issn = {1179-2035}, doi = {10.1007/s40279-015-0444-2}, pages = {473 -- 485}, year = {2016}, abstract = {To better understand what kinds of sports and exercise could be beneficial for the intervertebral disc (IVD), we performed a review to synthesise the literature on IVD adaptation with loading and exercise. The state of the literature did not permit a systematic review; therefore, we performed a narrative review. The majority of the available data come from cell or whole-disc loading models and animal exercise models. However, some studies have examined the impact of specific sports on IVD degeneration in humans and acute exercise on disc size. Based on the data available in the literature, loading types that are likely beneficial to the IVD are dynamic, axial, at slow to moderate movement speeds, and of a magnitude experienced in walking and jogging. Static loading, torsional loading, flexion with compression, rapid loading, high-impact loading and explosive tasks are likely detrimental for the IVD. Reduced physical activity and disuse appear to be detrimental for the IVD. We also consider the impact of genetics and the likelihood of a 'critical period' for the effect of exercise in IVD development. The current review summarises the literature to increase awareness amongst exercise, rehabilitation and ergonomic professionals regarding IVD health and provides recommendations on future directions in research.}, language = {en} } @article{YangKriechbaumerAlbrachtetal.2014, author = {Yang, Peng-Fei and Kriechbaumer, Andreas and Albracht, Kirsten and Sanno, Maximilian and Ganse, Bergita and Koy, Timmo and Shang, Peng and Br{\"u}ggemann, Gert-Peter and M{\"u}ller, Lars Peter and Rittweger, J{\"o}rn}, title = {A novel optical approach for assessing in vivo bone segment deformation and its application in muscle-bone relationship studies in humans}, series = {Journal of Orthopaedic Translation}, volume = {2}, journal = {Journal of Orthopaedic Translation}, number = {4}, publisher = {Elsevier}, address = {Singapore}, issn = {2214-0328}, doi = {10.1016/j.jot.2014.07.078}, pages = {238 -- 238}, year = {2014}, language = {en} } @inproceedings{GoldmannBraunsteinHeinrichetal.2015, author = {Goldmann, Jan-Peter and Braunstein, Bjoern and Heinrich, Kai and Sanno, Maximilian and St{\"a}udle, Benjamin and Ritzdorf, Wolfgang and Br{\"u}ggemann, Gert-Peter and Albracht, Kirsten}, title = {Joint work of the take-off leg during elite high jump}, series = {Proceedings of the 33th International Conference on Biomechanics in Sports (ISBS)}, booktitle = {Proceedings of the 33th International Conference on Biomechanics in Sports (ISBS)}, pages = {3 S.}, year = {2015}, language = {en} } @inproceedings{AbelBoninAlbrachtetal.2010, author = {Abel, Thomas and Bonin, Dominik and Albracht, Kirsten and Zeller, Sebastian and Br{\"u}ggemann, Gert-Peter and Burkett, Brendan and Str{\"u}der, Heiko K.}, title = {Kinematic profile of the elite handcyclist}, series = {28th International Conference on Biomechanics in Sports, Marquette, Michigan, USA, July 19 - 23, 2010}, booktitle = {28th International Conference on Biomechanics in Sports, Marquette, Michigan, USA, July 19 - 23, 2010}, issn = {1999-4168}, pages = {140 -- 141}, year = {2010}, language = {en} } @inproceedings{BegingPoghossianMlyneketal.2010, author = {Beging, Stefan and Poghossian, Arshak and Mlynek, D. and Hataihimakul, S. and Pedraza, A. and Dhawan, S. and Laube, N. and Kleinen, Lisa and Baldsiefen, Gerhard and Busch, Heinrich von and Sch{\"o}ning, Michael Josef}, title = {Ion-selective sensors for the determination of the risk of urinary stone formation}, series = {Micro- and Nanosystems in biochemical diagnosis : Principles and applications}, booktitle = {Micro- and Nanosystems in biochemical diagnosis : Principles and applications}, address = {Warsaw}, pages = {74 -- 80}, year = {2010}, language = {en} } @book{Pettrak2014, author = {Pettrak, J{\"u}rgen}, title = {Nutzung nachwachsender Rohstoffe bei der Herstellung thermoplastischer Elastomere aus Folgeprodukten der Olefinmetathese}, publisher = {Attenkofer}, address = {Straubing}, isbn = {978-3-942742-35-1}, pages = {147 Seiten}, year = {2014}, language = {de} } @article{BegingPoghossianSchoeningetal.2008, author = {Beging, Stefan and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Hataihimakul, Sudkanung and Busch, Heinz and Baldsiefen, Gerhard and Laube, N. and Kleinen, Lisa and Hosseiny, Reyhaneh}, title = {Feldeffektbasierender Ca2+-sensitiver Sensor f{\"u}r den Einsatz im Nativurin zur Bestimmung des Harnsteinbildungsrisikos}, series = {Sensoren und Messsysteme 2008 : 14. Fachtagung Ludwigsburg, 11. und 12. M{\"a}rz 2008 / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik}, journal = {Sensoren und Messsysteme 2008 : 14. Fachtagung Ludwigsburg, 11. und 12. M{\"a}rz 2008 / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik}, publisher = {VDI-Verl.}, address = {D{\"u}sseldorf}, isbn = {978-3-18-092011-5}, pages = {775 -- 782}, year = {2008}, language = {de} } @article{KolditzAlbinBrueggemannetal.2016, author = {Kolditz, Melanie and Albin, Thivaharan and Br{\"u}ggemann, Gert-Peter and Abel, Dirk and Albracht, Kirsten}, title = {Robotergest{\"u}tztes System f{\"u}r ein verbessertes neuromuskul{\"a}res Aufbautraining der Beinstrecker}, series = {at - Automatisierungstechnik}, volume = {64}, journal = {at - Automatisierungstechnik}, number = {11}, publisher = {De Gruyter}, address = {Berlin}, issn = {2196-677X}, doi = {10.1515/auto-2016-0044}, pages = {905 -- 914}, year = {2016}, abstract = {Neuromuskul{\"a}res Aufbautraining der Beinstrecker ist ein wichtiger Bestandteil in der Rehabilitation und Pr{\"a}vention von Muskel-Skelett-Erkrankungen. Effektives Training erfordert hohe Muskelkr{\"a}fte, die gleichzeitig hohe Belastungen von bereits gesch{\"a}digten Strukturen bedeuten. Um trainingsinduzierte Sch{\"a}digungen zu vermeiden, m{\"u}ssen diese Kr{\"a}fte kontrolliert werden. Mit heutigen Trainingsger{\"a}ten k{\"o}nnen diese Ziele allerdings nicht erreicht werden. F{\"u}r ein sicheres und effektives Training sollen durch den Einsatz der Robotik, Sensorik, eines Regelkreises sowie Muskel-Skelett-Modellen Belastungen am Zielgewebe direkt berechnet und kontrolliert werden. Auf Basis zweier Vorstudien zu m{\"o}glichen Stellgr{\"o}ßen wird der Aufbau eines robotischen Systems vorgestellt, das sowohl f{\"u}r Forschungszwecke als auch zur Entwicklung neuartiger Trainingsger{\"a}te verwendet werden kann.}, language = {de} }