@article{SimonisDawgulLuethetal.2005, author = {Simonis, A. and Dawgul, M. and L{\"u}th, H. and Sch{\"o}ning, Michael Josef}, title = {Miniaturised reference electrodes for field-effect sensors compatible to silicon chip technology}, series = {Electrochimica Acta. 51 (2005), H. 5}, journal = {Electrochimica Acta. 51 (2005), H. 5}, isbn = {0013-4686}, doi = {10.1016/j.electacta.2005.04.063}, pages = {930 -- 937}, year = {2005}, language = {en} } @article{SchoeningJacobsMucketal.2005, author = {Sch{\"o}ning, Michael Josef and Jacobs, M. and Muck, A. and Knobbe, D.-T. and Wang, J. and Chatrathi, M. and Spillmann, S.}, title = {Amperometric PDMS/glass capillary electrophoresis-based biosensor microchip for catechol and dopamin detection}, series = {Sensors and Actuators B. 108 (2005), H. 1-2}, journal = {Sensors and Actuators B. 108 (2005), H. 1-2}, isbn = {0925-4005}, pages = {688 -- 694}, year = {2005}, language = {en} } @article{SchoeningWagnerWangetal.2005, author = {Sch{\"o}ning, Michael Josef and Wagner, Torsten and Wang, C. and Otto, R. and Yoshinobu, T.}, title = {Development of a handheld 16 channel pen-type LAPS for electrochemical sensing}, series = {Sensors and Actuators B. 108 (2005)}, journal = {Sensors and Actuators B. 108 (2005)}, isbn = {0925-4005}, pages = {808 -- 814}, year = {2005}, language = {en} } @article{Schoening2005, author = {Sch{\"o}ning, Michael Josef}, title = {"Playing around" with field-effect sensors on the basis of EIS structures, LAPS and ISFETs}, series = {Sensors. 5 (2005), H. 3}, journal = {Sensors. 5 (2005), H. 3}, isbn = {1424-8220}, pages = {126 -- 138}, year = {2005}, language = {en} } @article{WagnerYoshinobuRaoetal.2005, author = {Wagner, Torsten and Yoshinobu, T. and Rao, C. and Otto, R. and Sch{\"o}ning, Michael Josef}, title = {„All-in-one" solid-state device based on a lightaddressable potentiometric sensor platform}, series = {Transducers '05 : the 13th International Conference on Solid-State Sensors, Actuators and Microsystems ; Seoul, Korea, [June 5 - 9, 2005] ; digest of technical papers / sponsored by Korean Sensors Society. Technical co-sponsors: IEEE Electron Devices Society}, journal = {Transducers '05 : the 13th International Conference on Solid-State Sensors, Actuators and Microsystems ; Seoul, Korea, [June 5 - 9, 2005] ; digest of technical papers / sponsored by Korean Sensors Society. Technical co-sponsors: IEEE Electron Devices Society}, publisher = {IEEE Operations Center}, address = {Piscataway, NJ}, isbn = {0-7803-83995-6}, pages = {1872 -- 1875}, year = {2005}, language = {en} } @article{YoshinobuIwasakiUietal.2005, author = {Yoshinobu, T. and Iwasaki, H. and Ui, Y. and Furuichi, K. and Ermelenko, Y. and Mourzina, Y. and Wagner, Torsten and N{\"a}ther, Niko and Sch{\"o}ning, Michael Josef}, title = {The light-addressable potentiometric sensor for multi-ion sensing and imaging}, series = {Methods. 37 (2005), H. 1}, journal = {Methods. 37 (2005), H. 1}, isbn = {1046-2023}, pages = {99 -- 102}, year = {2005}, language = {en} } @article{MuellerVeggianTurekColautti2005, author = {M{\"u}ller-Veggian, Mattea and Turek, M. and Colautti, P.}, title = {The new Twin mini TEPC: an advanced tool for Boron Neutron Capture Therapy}, series = {Annual report / Istituto Nazionale di Fisica Nucleare, LNL, Laboratori Nazionali di Legnaro. 2004 (2005)}, journal = {Annual report / Istituto Nazionale di Fisica Nucleare, LNL, Laboratori Nazionali di Legnaro. 2004 (2005)}, isbn = {88-7337-008-X}, pages = {244 -- 245}, year = {2005}, language = {en} } @article{MuellerVeggianDeNardoBalbinotetal.2005, author = {M{\"u}ller-Veggian, Mattea and De Nardo, L. and Balbinot, G. and Colautti, P.}, title = {Leak Microstructures Operation at low pressure of propane: application at the Trigger\&Anti-Trigger system of the STARTRACK Experiment}, series = {Annual report / Istituto Nazionale di Fisica Nucleare, LNL, Laboratori Nazionali di Legnaro. 2004 (2005)}, journal = {Annual report / Istituto Nazionale di Fisica Nucleare, LNL, Laboratori Nazionali di Legnaro. 2004 (2005)}, isbn = {88-7337-008-X}, pages = {242 -- 243}, year = {2005}, language = {en} } @article{MuellerVeggianGarbeNouretal.2005, author = {M{\"u}ller-Veggian, Mattea and Garbe, S. and Nour, Y. and Wolf, K.}, title = {Scattered dose determination using the semiconductor diodes for a mask based whole brain radiotherapy (WBRT) with high-energy photons}, series = {Biomedizinische Technik. 50 (2005), H. 2}, journal = {Biomedizinische Technik. 50 (2005), H. 2}, isbn = {0932-4666}, pages = {1069 -- 1070}, year = {2005}, language = {en} } @article{MuellerVeggianGarbeNouretal.2005, author = {M{\"u}ller-Veggian, Mattea and Garbe, S. and Nour, Y. and Wolf, K.}, title = {468 Scatter dose determination at the eye lens during a mask based whole brain radiotherapy (WBRT)}, series = {Radiotherapy and Oncology}, volume = {76}, journal = {Radiotherapy and Oncology}, number = {Suppl. 2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0167-8140}, doi = {10.1016/S0167-8140(05)81444-6}, pages = {S202}, year = {2005}, language = {en} } @article{KotliarKoshitzSvetlowaetal.2005, author = {Kotliar, Konstantin and Koshitz, I. N. and Svetlowa, O. V. and Makarov, F. N.}, title = {Biomechanical analysis of traditional and contemporary conceptions on pathogenesis of the primary open angle glaucoma / Koshitz, I. N. ; Svetlova, O. V. ; Kotliar, K. E. ; Makarov, F. N. ; Smolnikov, B. A.}, series = {Glaukoma (2005)}, journal = {Glaukoma (2005)}, publisher = {-}, pages = {41 -- 63}, year = {2005}, language = {en} } @article{StreunChristHellendungetal.2005, author = {Streun, M. and Christ, D. and Hellendung, A. and Larue, H. and Ziemons, Karl and Halling, H.}, title = {Effects of crosstalk and gain nonuniformity using multichannel PMTs in the Clearpet® scanner}, series = {Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, volume = {537}, journal = {Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, number = {1-2}, isbn = {0168-9002}, pages = {402 -- 405}, year = {2005}, abstract = {The ClearPET® scanners developed by the Crystal Clear Collaboration use multichannel PMTs as photodetectors with scintillator pixels coupled individually to each channel. In order to localize an event each channel anode is connected to a comparator that triggers when the anode signal exceeds a common predefined threshold. Two major difficulties here are crosstalk of light and the gain nonuniformity of the PMT channels. Crosstalk can generate false triggering in channels adjacent to the actual event. On the one hand this can be suppressed by sufficiently increasing the threshold, but on the other hand a threshold too high can already prevent valid events on the lower gain channels from being detected. Finally, both effects restrict the dynamic range of pulse heights that can be processed. The requirements to the dynamic range are not low as the ClearPET® scanners detect the depth of interaction by phoswich pixels consisting of LSO and Lu0.7Y0.3AP, two scintillators with different light yields. We will present a model to estimate the achievable dynamic range and show solutions to increase it.}, language = {en} } @article{TemizArtmannKayatekinUysaletal.2005, author = {Temiz Artmann, Ayseg{\"u}l and Kayatekin, Muammer B. and Uysal, N. and Resmi, H.}, title = {Does antioxidant supplementation alter the effects of acute exercise on erythrocyte aggregation, deformability and endothelium adhesion in untrained rats? Kayatekin, Muammer B.; Uysal N.; Resmi, H.; Bediz, Seref C.; Temiz Artmann, A.; Gen{\c{c}}, S.; Tugyan, K.}, series = {International Journal for Vitamin and Nutrition Research. 75 (2005), H. 4}, journal = {International Journal for Vitamin and Nutrition Research. 75 (2005), H. 4}, isbn = {0300-9831}, pages = {243 -- 250}, year = {2005}, language = {en} } @article{TemizArtmannResmiAkhunlaretal.2005, author = {Temiz Artmann, Ayseg{\"u}l and Resmi, Halil and Akhunlar, H{\"u}lya and G{\"u}ner, G{\"u}l}, title = {In vitro effects of high glucose concentrations on membrane protein sulfhydryl oxidation, G-actin and deformability of human erythrocytes. Resmi, Halil ; Akhunlar, H{\"u}lya ; Temiz Artmann, Ayseg{\"u}l ; G{\"u}ner, G{\"u}l}, series = {Cell biochemistry and function. 23 (2005), H. 3}, journal = {Cell biochemistry and function. 23 (2005), H. 3}, isbn = {0263-6484}, pages = {163 -- 168}, year = {2005}, language = {en} } @article{TemizArtmannAkhisarogluSercanetal.2005, author = {Temiz Artmann, Ayseg{\"u}l and Akhisaroglu, M. and Sercan, Z. and Kayatekin, B. M.}, title = {Adhesion of Erythrocytes to Endothelial Cells After Acute Exercise: Differences in Red Blood Cells from Juvenile and Adult Rats. Temiz Artmann, A.; Akhisaroglu, M.; Sercan, Z.; Kayatekin, BM.; Yorukoglu, K.; Kirkali, G.}, series = {Physiological Research (2005)}, journal = {Physiological Research (2005)}, isbn = {0862-8408}, year = {2005}, language = {en} } @article{SanderFidlerKlimala2005, author = {Sander, Volker and Fidler, Markus and Klimala, Wojciech}, title = {Traffic shaping in aggregate-based networks: implementation and analysis / Fidler, Markus ; Sander, Volker ; Klimala, Wojciech}, series = {Computer Communications. 28 (2005), H. 3}, journal = {Computer Communications. 28 (2005), H. 3}, isbn = {0140-3664}, pages = {274 -- 286}, year = {2005}, language = {en} } @article{TemizArtmannSaklamazComlekcietal.2005, author = {Temiz Artmann, Ayseg{\"u}l and Saklamaz, Ali and Comlekci, Abdurrahman and Caliskan, Sezer}, title = {The beneficial effects of lipid-lowering drugs beyond lipid-lowering effects: A comparative study with pravastatin, atorvastatin, and fenofibrate in patients with type IIa and type IIb hyperlipidemia / Saklamaz, Ali ; Comlekci, Abdurrahman ; Temiz, Aysegu}, series = {Metabolism. 54 (2005), H. 5}, journal = {Metabolism. 54 (2005), H. 5}, isbn = {0026-0495}, pages = {677 -- 681}, year = {2005}, language = {en} } @book{GrotendorstScottMannetal.2005, author = {Grotendorst, Johannes and Scott, Tony C. and Mann, Robert and Martinez Il, Roberto E.}, title = {General Relativity and Quantum Mechanics: Towards a Generalization of the Lambert W Function / Scott, Tony C. ; Mann, Robert ; Martinez Il, Roberto E. ; Grotendorst, Johannes}, address = {J{\"u}lich}, pages = {15 S.}, year = {2005}, language = {en} } @article{DiktaGhoraiSchmidt2005, author = {Dikta, Gerhard and Ghorai, Jugal and Schmidt, Christian}, title = {The Central Limit Theorem under Semiparametric Random Censorship Models}, series = {Journal of Statistical Planning and Inference. 127 (2005), H. 1}, journal = {Journal of Statistical Planning and Inference. 127 (2005), H. 1}, isbn = {0378-3758}, pages = {23 -- 51}, year = {2005}, language = {en} } @article{KaminskySimonsGatzweileretal.2005, author = {Kaminsky, Randolph and Simons, Antoine and Gatzweiler, Karl-Heinz and Weber, Hans-Joachim}, title = {Flow visualization by means of PIV of an artificial aortic heart valve fixed into a mock aorta}, series = {Acta Mechanica Slovaka 2-A. 9 (2005)}, journal = {Acta Mechanica Slovaka 2-A. 9 (2005)}, pages = {343 -- 348}, year = {2005}, language = {en} } @article{KaminskyWeberSimonsetal.2005, author = {Kaminsky, Randolph and Weber, Hans-Joachim and Simons, Antoine and Kallweit, Stephan and Kramm, K. and Verdonck, Pascale}, title = {Comparison of the flow downstream two prototypes of a new monoleaflet artificial aortic heart valve by means of PIV visualization}, series = {Computer methods in biomechanics and biomedical engineering. 8 (2005), H. 4, Suppl. 1}, journal = {Computer methods in biomechanics and biomedical engineering. 8 (2005), H. 4, Suppl. 1}, isbn = {1476-8259}, pages = {159 -- 160}, year = {2005}, language = {en} } @book{WeberKaminskyKallweitetal.2005, author = {Weber, Hans-Joachim and Kaminsky, Radoslav and Kallweit, Stephan and Simons, Antoine}, title = {PIV measurements with high temporal resolution behind artificial heart valves}, pages = {9 S.}, year = {2005}, language = {en} } @article{Staat2005, author = {Staat, Manfred}, title = {Local and global collapse pressure of longitudinally flawed pipes and cylindrical vessels}, series = {International Journal of Pressure Vessels and Piping. 82 (2005), H. 3}, journal = {International Journal of Pressure Vessels and Piping. 82 (2005), H. 3}, isbn = {0308-0161}, pages = {217 -- 225}, year = {2005}, language = {en} } @article{GrajewskiHronTurek2005, author = {Grajewski, Matthias and Hron, Jaroslav and Turek, Stefan}, title = {Dual weighted a posteriori error estimation for a new nonconforming linear finite element on quadrilaterals}, series = {Applied Numerical Mathematics}, volume = {54}, journal = {Applied Numerical Mathematics}, number = {3-4}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0168-9274}, doi = {10.1016/j.apnum.2004.09.016}, pages = {504 -- 518}, year = {2005}, abstract = {After a short introduction of a new nonconforming linear finite element on quadrilaterals recently developed by Park, we derive a dual weighted residual-based a posteriori error estimator (in the sense of Becker and Rannacher) for this finite element. By computing a corresponding dual solution we estimate the error with respect to a given target error functional. The reliability and efficiency of this estimator is analyzed in several numerical experiments.}, language = {en} } @article{Staat2005, author = {Staat, Manfred}, title = {Local and global collapse pressure of longitudinally flawed pipes and cylindrical vessels}, year = {2005}, abstract = {Limit loads can be calculated with the finite element method (FEM) for any component, defect geometry, and loading. FEM suggests that published long crack limit formulae for axial defects under-estimate the burst pressure for internal surface defects in thick pipes while limit loads are not conservative for deep cracks and for pressure loaded crack-faces. Very deep cracks have a residual strength, which is modelled by a global collapse load. These observations are combined to derive new analytical local and global collapse loads. The global collapse loads are close to FEM limit analyses for all crack dimensions.}, subject = {Finite-Elemente-Methode}, language = {en} } @article{Staat2005, author = {Staat, Manfred}, title = {Direct finite element route for design-by-analysis of pressure components}, year = {2005}, abstract = {In the new European standard for unfired pressure vessels, EN 13445-3, there are two approaches for carrying out a Design-by-Analysis that cover both the stress categorization method (Annex C) and the direct route method (Annex B) for a check against global plastic deformation and against progressive plastic deformation. This paper presents the direct route in the language of limit and shakedown analysis. This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for mechanical and thermal actions. One observation from the examples is that the so-called 3f (3Sm) criterion fails to be a reliable check against progressive plastic deformation. Precise conditions are given, which greatly restrict the applicability of the 3f criterion.}, subject = {Einspielen }, language = {en} } @article{DigelTemizArtmannNishikawaetal.2005, author = {Digel, Ilya and Temiz Artmann, Ayseg{\"u}l and Nishikawa, K. and Cook, M.}, title = {Bactericidal effects of plasma-generated cluster ions}, series = {Medical and Biological Engineering and Computing. 43 (2005), H. 6}, journal = {Medical and Biological Engineering and Computing. 43 (2005), H. 6}, isbn = {1741-0444}, pages = {800 -- 807}, year = {2005}, language = {en} } @article{StaatHeitzerLangetal.2005, author = {Staat, Manfred and Heitzer, M. and Lang, H. and Wirtz, K.}, title = {Direct Finite Element Route for Design-by-Analysis of Pressure Components}, series = {International Journal of Pressure Vessels and Piping. 82 (2005), H. 1}, journal = {International Journal of Pressure Vessels and Piping. 82 (2005), H. 1}, isbn = {0308-0161}, pages = {61 -- 67}, year = {2005}, language = {en} } @article{SchoeningNaetherAugeretal.2005, author = {Sch{\"o}ning, Michael Josef and N{\"a}ther, Niko and Auger, V. and Poghossian, Arshak and Koudelka-Hep, M.}, title = {Miniaturised flow-through cell with integrated capacitive EIS sensor fabricated at wafer level using Si and SU-8 technologies}, series = {Sensors and Actuators B. 108 (2005), H. 1-2}, journal = {Sensors and Actuators B. 108 (2005), H. 1-2}, isbn = {0925-4005}, pages = {986 -- 992}, year = {2005}, language = {en} } @article{SchoeningBrinkmannRolkaetal.2005, author = {Sch{\"o}ning, Michael Josef and Brinkmann, D. and Rolka, David and Demuth, C. and Poghossian, Arshak}, title = {CIP (cleaning-in-place) suitable "non-glass" pH sensor based on a Ta2O5-gate EIS structure}, series = {Sensors and Actuators B: Chemical. 111-112 (2005)}, journal = {Sensors and Actuators B: Chemical. 111-112 (2005)}, isbn = {0925-4005}, pages = {423 -- 429}, year = {2005}, language = {en} } @article{NaetherRolkaPoghossianetal.2005, author = {N{\"a}ther, Niko and Rolka, David and Poghossian, Arshak and Koudelka-Hep, M. and Sch{\"o}ning, Michael Josef}, title = {Two microcell flow-injection analysis (FIA) platforms for capacitive silicon-based field-effect sensors}, series = {Electrochimica Acta. 51 (2005), H. 5}, journal = {Electrochimica Acta. 51 (2005), H. 5}, isbn = {0013-4686}, doi = {10.1016/j.electacta.2005.04.066}, pages = {924 -- 929}, year = {2005}, language = {en} } @article{StulpeBjelakovic2005, author = {Stulpe, Werner and Bjelakovic, Igor}, title = {The Projective Hilbert Space as a Classical Phase Space for Nonrelativistic Quantum Dynamics. Bjelakovic, Igor; Stulpe, Werner}, series = {International Journal of Theoretical Physics. 44 (2005), H. 11}, journal = {International Journal of Theoretical Physics. 44 (2005), H. 11}, isbn = {1572-9575}, pages = {2041 -- 2049}, year = {2005}, language = {en} } @article{PoghossianCherstvyIngebrandtetal.2005, author = {Poghossian, Arshak and Cherstvy, A. and Ingebrandt, S. and Offenh{\"a}usser, A. and Sch{\"o}ning, Michael Josef}, title = {Possibilities and limitations of label-free detection of DNA hybridization with field-effect-based devices}, series = {Sensors and Actuators B. 111-112 (2005)}, journal = {Sensors and Actuators B. 111-112 (2005)}, isbn = {0925-4005}, pages = {470 -- 480}, year = {2005}, language = {en} } @article{MaggakisKelemenDigelArtmann2005, author = {Maggakis-Kelemen, Christina and Digel, Ilya and Artmann, Gerhard}, title = {Polystyrene sulfonate/Polyallylamine hydrochloride microcapsules as potential artificial red blood cells - improvement of capsule flexibility}, series = {Biomedizinische Technik. 50 (2005), H. Erg.-Bd. 1}, journal = {Biomedizinische Technik. 50 (2005), H. Erg.-Bd. 1}, pages = {324 -- 326}, year = {2005}, language = {en} } @article{PoghossianPlatenSchoening2005, author = {Poghossian, Arshak and Platen, J. and Sch{\"o}ning, Michael Josef}, title = {Towards self-aligned nanostructures by means of layerexpansion technique}, series = {Electrochimica Acta. 51 (2005), H. 5}, journal = {Electrochimica Acta. 51 (2005), H. 5}, isbn = {0013-4686}, pages = {838 -- 843}, year = {2005}, language = {en} } @article{ZiemonsAuffrayBarbieretal.2005, author = {Ziemons, Karl and Auffray, Etiennette and Barbier, R. and Brandenburg, G. and Bruyndonckx, P.}, title = {The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner}, series = {Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, volume = {537}, journal = {Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, number = {1-2}, issn = {0168-9002}, pages = {307 -- 311}, year = {2005}, abstract = {Second generation high-performance PET scanners, called ClearPET™1, have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and high spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8×8 crystals of 2×2×10 mm3 are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm.The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time, which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view. Preliminary data shows a correct identification of the crystal layer about (98±1)\%. Typically the energy resolution is (23.3±0.5)\% for the luyap layer and (15.4±0.4)\% for the lso layer. early studies showed the timing resolution of 2 ns FWHM and 4.8 ns FWTM. the intrinsic spatial resolution ranges from 1.37 mm to 1.61 mm full-width of half-maximum (FWHM) with a mean of 1.48 mm FWHM. further improvements in image and energy resolution are expected when the system geometry is fully modeled.}, language = {en} } @article{TemizArtmannLinderKayseretal.2005, author = {Temiz Artmann, Ayseg{\"u}l and Linder, Peter and Kayser, Peter and Digel, Ilya}, title = {NMR in vitro effects on proliferation, apoptosis, and viability of human chondrocytes and osteoblasts}, series = {Methods and findings in Experimental and Clinical Pharmacology. 27 (2005), H. 6}, journal = {Methods and findings in Experimental and Clinical Pharmacology. 27 (2005), H. 6}, isbn = {0379-0355}, pages = {391 -- 394}, year = {2005}, language = {en} } @article{KhodaverdiChatziioannouWeberetal.2005, author = {Khodaverdi, M. and Chatziioannou, A. F. and Weber, S. and Ziemons, Karl and Halling, H. and Pietrzyk, Uwe}, title = {Investigation of different MicroCT scanner configurations by GEANT4 simulations}, series = {IEEE Transactions on Nuclear Science}, volume = {52}, journal = {IEEE Transactions on Nuclear Science}, number = {1}, isbn = {0018-9499}, pages = {188 -- 192}, year = {2005}, abstract = {This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.}, language = {en} } @inproceedings{WagnerSchoening2006, author = {Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Preface of the Special Issue of I3S 2005 in J{\"u}lich (Germany)}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1365}, year = {2006}, abstract = {International Symposium on Sensor Science, I3S 2005 <3; 2005; Juelich, Germany> In: Sensors 2006, 6, 260-261 ISSN 1424-8220}, subject = {Biosensor}, language = {en} } @inproceedings{SrivastavaSinghDhandetal.2006, author = {Srivastava, Alok and Singh, Virendra and Dhand, Chetna and Kaur, Manindar and Singh, Tejvir and Witte, Katrin and Scherer, Ulrich W.}, title = {Study of swift heavy ion modified conduction polymer composites for application as gas sensor}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1345}, year = {2006}, abstract = {A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas.}, subject = {Biosensor}, language = {en} } @inproceedings{ChaiybounTrauteKiesewetteretal.2006, author = {Chaiyboun, Ali and Traute, R{\"u}diger and Kiesewetter, Olaf and Ahlers, Simon and M{\"u}ller, Gerhard and Doll, Theodor}, title = {Modular analytical multicomponent analysis in gas sensor arrays}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1358}, year = {2006}, abstract = {A multi-sensor system is a chemical sensor system which quantitatively and qualitatively records gases with a combination of cross-sensitive gas sensor arrays and pattern recognition software. This paper addresses the issue of data analysis for identification of gases in a gas sensor array. We introduce a software tool for gas sensor array configuration and simulation. It concerns thereby about a modular software package for the acquisition of data of different sensors. A signal evaluation algorithm referred to as matrix method was used specifically for the software tool. This matrix method computes the gas concentrations from the signals of a sensor array. The software tool was used for the simulation of an array of five sensors to determine gas concentration of CH4, NH3, H2, CO and C2H5OH. The results of the present simulated sensor array indicate that the software tool is capable of the following: (a) identify a gas independently of its concentration; (b) estimate the concentration of the gas, even if the system was not previously exposed to this concentration; (c) tell when a gas concentration exceeds a certain value. A gas sensor data base was build for the configuration of the software. With the data base one can create, generate and manage scenarios and source files for the simulation. With the gas sensor data base and the simulation software an on-line Web-based version was developed, with which the user can configure and simulate sensor arrays on-line.}, subject = {Biosensor}, language = {en} } @inproceedings{SakthivelWeppner2006, author = {Sakthivel, Mariappan and Weppner, Werner}, title = {Response behaviour of a hydrogen sensor based on ionic conducting polymer-metal interfaces prepared by the chemical reduction method}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1399}, year = {2006}, abstract = {A solid-state amperometric hydrogen sensor based on a protonated Nafion membrane and catalytic active electrode operating at room temperature was fabricated and tested. Ionic conducting polymer-metal electrode interfaces were prepared chemically by using the impregnation-reduction method. The polymer membrane was impregnated with tetra-ammine platinum chloride hydrate and the metal ions were subsequently reduced by using either sodium tetrahydroborate or potassium tetrahydroborate. The hydrogen sensing characteristics with air as reference gas is reported. The sensors were capable of detecting hydrogen concentrations from 10 ppm to 10\% in nitrogen. The response time was in the range of 10-30 s and a stable linear current output was observed. The thin Pt films were characterized by XRD, Infrared Spectroscopy, Optical Microscopy, Atomic Force Microscopy, Scanning Electron Microscopy and EDAX.}, subject = {Biosensor}, language = {en} } @inproceedings{KoplinSiemonsOcenValentinetal.2006, author = {Koplin, Tobias J. and Siemons, Maike and Oc{\´e}n-Val{\´e}ntin, C{\´e}sar and Sanders, Daniel and Simon, Ulrich}, title = {Workflow for high throughput screening of gas sensing materials}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1407}, year = {2006}, abstract = {The workflow of a high throughput screening setup for the rapid identification of new and improved sensor materials is presented. The polyol method was applied to prepare nanoparticular metal oxides as base materials, which were functionalised by surface doping. Using multi-electrode substrates and high throughput impedance spectroscopy (HT-IS) a wide range of materials could be screened in a short time. Applying HT-IS in search of new selective gas sensing materials a NO2-tolerant NO sensing material with reduced sensitivities towards other test gases was identified based on iridium doped zinc oxide. Analogous behaviour was observed for iridium doped indium oxide.}, subject = {Biosensor}, language = {en} } @inproceedings{SpannhakeSchulzHelwigetal.2006, author = {Spannhake, Jan and Schulz, Olaf and Helwig, Andreas and Krenkow, Angelika and M{\"u}ller, Gerhard and Doll, Theodor}, title = {High-temperature MEMS heater platforms: long-term performance of metal and semiconductor heater materials}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1513}, year = {2006}, abstract = {Micromachined thermal heater platforms offer low electrical power consumption and high modulation speed, i.e. properties which are advantageous for realizing nondispersive infrared (NDIR) gas- and liquid monitoring systems. In this paper, we report on investigations on silicon-on-insulator (SOI) based infrared (IR) emitter devices heated by employing different kinds of metallic and semiconductor heater materials. Our results clearly reveal the superior high-temperature performance of semiconductor over metallic heater materials. Long-term stable emitter operation in the vicinity of 1300 K could be attained using heavily antimony-doped tin dioxide (SnO2:Sb) heater elements.}, subject = {Biosensor}, language = {en} } @inproceedings{KatzWillner2006, author = {Katz, Eugenii and Willner, Itamar}, title = {Magneto-controlled quantized electron transfer to surface-confined redox units and metal nanoparticles}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1528}, year = {2006}, abstract = {Hydrophobic magnetic nanoparticles (NPs) consisting of undecanoate-capped magnetite (Fe3O4, average diameter ca. 5 nm) are used to control quantized electron transfer to surface-confined redox units and metal NPs. A two-phase system consisting of an aqueous electrolyte solution and a toluene phase that includes the suspended undecanoatecapped magnetic NPs is used to control the interfacial properties of the electrode surface. The attracted magnetic NPs form a hydrophobic layer on the electrode surface resulting in the change of the mechanisms of the surface-confined electrochemical processes. A quinone-monolayer modified Au electrode demonstrates an aqueous-type of the electrochemical process (2e-+2H+ redox mechanism) for the quinone units in the absence of the hydrophobic magnetic NPs, while the attraction of the magnetic NPs to the surface results in the stepwise single-electron transfer mechanism characteristic of a dry nonaqueous medium. Also, the attraction of the hydrophobic magnetic NPs to the Au electrode surface modified with Au NPs (ca. 1.4 nm) yields a microenvironment with a low dielectric constant that results in the single-electron quantum charging of the Au NPs.}, subject = {Biosensor}, language = {en} } @inproceedings{PijanowskaRemiszewska2006, author = {Pijanowska, Dorota G. and Remiszewska, Elzbieta}, title = {pH-based detection of phenylalnine by potentiometric and colorimetric methods}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1536}, year = {2006}, abstract = {In this paper, methods of sample preparation for potentiometric measurement of phenylalanine are presented. Basing on the spectrophotometric measurements of phenylalanine, the concentrations of reagents of the enzymatic reaction (10 mM L-Phe, 0,4 mM NAD+, 2U L-PheDH) were determined. Then, the absorption spectrum of the reaction product, NADH, was monitored (maximum peak at 340 nm). The results obtained by the spectrophotometric method were compared with the results obtained by the colourimetry, using pH indicators. The above-mentioned two methods will be used as references for potentiometric measurements of phenylalanine concentration.}, subject = {Biosensor}, language = {en} } @inproceedings{AridaKloockSchoening2006, author = {Arida, Hassan A. and Kloock, Joachim P. and Sch{\"o}ning, Michael Josef}, title = {Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1545}, year = {2006}, abstract = {A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors.}, subject = {Biosensor}, language = {en} } @inproceedings{BarekFischerNavratiletal.2006, author = {Barek, Jiri and Fischer, Jan and Navratil, Tomas and Peckova, Karolina and Yosypchuk, Bogdan}, title = {Silver solid amalgam electrodes as sensors for chemical carcinogens}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1554}, year = {2006}, abstract = {The applicability of differential pulse voltammetry (DPV) and adsorptive stripping voltammetry (AdSV) at a non-toxic meniscus-modified silver solid amalgam electrode (m-AgSAE) for the determination of trace amounts of genotoxic substances was demonstrated on the determination of micromolar and submicromolar concentrations of 3-nitrofluoranthene using methanol - 0.01 mol L-1 NaOH (9:1) mixture as a base electrolyte and of Ostazine Orange using 0.01 mol L-1 NaOH as a base electrolyte.}, subject = {Biosensor}, language = {en} } @inproceedings{BaronasIvanauskasKulys2006, author = {Baronas, Romas and Ivanauskas, Feliksas and Kulys, Juozas}, title = {Mathematical modeling of biosensors based on an array of enzyme microreactors}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1569}, year = {2006}, abstract = {This paper presents a two-dimensional-in-space mathematical model of biosensors based on an array of enzyme microreactors immobilised on a single electrode. The modeling system acts under amperometric conditions. The microreactors were modeled by particles and by strips. The model is based on the diffusion equations containing a nonlinear term related to the Michaelis-Menten kinetics of the enzymatic reaction. The model involves three regions: an array of enzyme microreactors where enzyme reaction as well as mass transport by diffusion takes place, a diffusion limiting region where only the diffusion takes place, and a convective region, where the analyte concentration is maintained constant. Using computer simulation, the influence of the geometry of the microreactors and of the diffusion region on the biosensor response was investigated. The digital simulation was carried out using the finite difference technique.}, subject = {Biosensor}, language = {en} } @inproceedings{LeiMulchandaniChenetal.2006, author = {Lei, Yu and Mulchandani, Priti and Chen, Wilfred and Mulchandani, Ashok}, title = {Biosensor for direct determination of fenitrothion and EPN using recombinant Pseudomonas putida JS444 with surface expressed organophosphorus hydrolase. 1. modified clark oxygen electrode}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1573}, year = {2006}, abstract = {This paper reports a first microbial biosensor for rapid and cost-effective determination of organophosphorus pesticides fenitrothion and EPN. The biosensor consisted of recombinant PNP-degrading/oxidizing bacteria Pseudomonas putida JS444 anchoring and displaying organophosphorus hydrolase (OPH) on its cell surface as biological sensing element and a dissolved oxygen electrode as the transducer. Surfaceexpressed OPH catalyzed the hydrolysis of fenitrothion and EPN to release 3-methyl-4-nitrophenol and p-nitrophenol, respectively, which were oxidized by the enzymatic machinery of Pseudomonas putida JS444 to carbon dioxide while consuming oxygen, which was measured and correlated to the concentration of organophosphates. Under the optimum operating conditions, the biosensor was able to measure as low as 277 ppb of fenitrothion and 1.6 ppm of EPN without interference from phenolic compounds and other commonly used pesticides such as carbamate pesticides, triazine herbicides and organophosphate pesticides without nitrophenyl substituent. The applicability of the biosensor to lake water was also demonstrated.}, subject = {Biosensor}, language = {en} }