@article{FoersterLepsaFreundt2007, author = {F{\"o}rster, Arnold and Lepsa, M. I. and Freundt, D.}, title = {Hot electron injector Gunn diode for advanced driver assistance systems}, series = {Applied physics A: materials science and processing. 87 (2007), H. 3}, journal = {Applied physics A: materials science and processing. 87 (2007), H. 3}, isbn = {0947-8396}, pages = {545 -- 558}, year = {2007}, language = {en} } @article{PoghossianAbouzarChristiaensetal.2007, author = {Poghossian, Arshak and Abouzar, Maryam H. and Christiaens, P. and Williams, O. A. and Haenen, K. and Wagner, P. and Sch{\"o}ning, Michael Josef}, title = {Nanocrystalline diamond-based field-effect (bio-)chemical sensor}, series = {8. Dresdner Sensor-Symposium : Sensoren f{\"u}r Umwelt, Klima und Sicherheit, Biosensoren und Biosysteme, Sensoren und Sensorsysteme f{\"u}r die Prozesstechnik, Trends in der Sensortechnik, Materialentwicklung f{\"u}r die Sensorik; 8. Dresdner Sensor-Symposium, 10. - 12. Dezember 2007, Dresden / Gerald Gerlach ... (Hg.)}, journal = {8. Dresdner Sensor-Symposium : Sensoren f{\"u}r Umwelt, Klima und Sicherheit, Biosensoren und Biosysteme, Sensoren und Sensorsysteme f{\"u}r die Prozesstechnik, Trends in der Sensortechnik, Materialentwicklung f{\"u}r die Sensorik; 8. Dresdner Sensor-Symposium, 10. - 12. Dezember 2007, Dresden / Gerald Gerlach ... (Hg.)}, publisher = {TUDpress, Verl. der Wissenschaften}, address = {Dresden}, isbn = {978-3-940046-45-1}, pages = {191 -- 194}, year = {2007}, language = {en} } @article{WagnerMolinaBisellietal.2007, author = {Wagner, Torsten and Molina, R. and Biselli, Manfred and Canzoneri, Michele and Schnitzler, Thomas and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {A light-addressable potentiometric sensor system for fast, simultaneous and spatial detection of the metabolic activity of biological cells}, series = {Transducers '07 Eurosensors XXI : digest of technical papers ; the14th International Conference on Solid-State Sensors, Actuators and Microsystems, June 10-14, 2007, Lyon, France / Gilles Delapierre (Ed.)}, journal = {Transducers '07 Eurosensors XXI : digest of technical papers ; the14th International Conference on Solid-State Sensors, Actuators and Microsystems, June 10-14, 2007, Lyon, France / Gilles Delapierre (Ed.)}, publisher = {IEEE}, address = {Piscataway}, isbn = {1-4244-0841-5}, pages = {1107 -- 1110}, year = {2007}, language = {en} } @article{ChristiaensAbouzarPoghossianetal.2007, author = {Christiaens, P. and Abouzar, Maryam H. and Poghossian, Arshak and Wagner, Torsten and Bijnens, N. and Williams, O. A. and Daenen, M. and Haenen, K. and Sch{\"o}ning, Michael Josef and Wagner, P.}, title = {Nanocrystalline diamond-based field-effect capacitive pH sensor}, series = {Transducers '07 Eurosensors XXI : digest of technical papers ; the14th International Conference on Solid-State Sensors, Actuators and Microsystems, June 10-14, 2007, Lyon, France / Gilles Delapierre (Ed.)}, journal = {Transducers '07 Eurosensors XXI : digest of technical papers ; the14th International Conference on Solid-State Sensors, Actuators and Microsystems, June 10-14, 2007, Lyon, France / Gilles Delapierre (Ed.)}, publisher = {IEEE}, address = {Piscataway}, isbn = {1-4244-0841-5}, pages = {1891 -- 1894}, year = {2007}, language = {en} } @article{SchoeningPoghossian2008, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {Detection of charged macromolecules by means of field-effect devices (FEDs): possibilities and limitations}, series = {Electrochemical sensors, biosensors and their biomedical applications / ed. by Xueji Zhang ...}, journal = {Electrochemical sensors, biosensors and their biomedical applications / ed. by Xueji Zhang ...}, publisher = {Elsevier Acad. Press}, address = {Amsterdam}, isbn = {978-0-12-373738-0}, pages = {187 -- 212}, year = {2008}, language = {en} } @article{PoghossianSchoening2007, author = {Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Chemical and biological field-effect sensors for liquids - a status report}, series = {Handbook of biosensors and biochips / ed. Robert S. Marks ... Bd. 1}, journal = {Handbook of biosensors and biochips / ed. Robert S. Marks ... Bd. 1}, publisher = {Wiley}, address = {Chichester}, isbn = {978-0-470-01905-4}, pages = {395 -- 412}, year = {2007}, language = {en} } @article{SchoeningKloock2007, author = {Sch{\"o}ning, Michael Josef and Kloock, Joachim P.}, title = {About 20 years of silicon-based thin-film sensors with chalcogenide glass materials for heavy metal analysis: Technological aspects of fabrication and miniaturization}, series = {Electroanalysis. 19 (2007), H. 19-20}, journal = {Electroanalysis. 19 (2007), H. 19-20}, isbn = {1040-0397}, pages = {2029 -- 2038}, year = {2007}, language = {en} } @article{WagnerSchoening2007, author = {Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Light-addressable potentiometric sensors (LAPS): recent trends and applications}, series = {Electrochemical sensor analysis / edited by S. Alegret ...}, journal = {Electrochemical sensor analysis / edited by S. Alegret ...}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {978-0-444-53053-0}, pages = {87 -- 128}, year = {2007}, language = {en} } @article{WagnerKloockSchoening2007, author = {Wagner, Torsten and Kloock, Joachim P. and Sch{\"o}ning, Michael Josef}, title = {Determination of cadmium concentration and pH value in aqueous solutions by means of a handheld light-addressable potentiometric sensor (LAPS) device}, series = {Electrochemical sensor analysis / edited by S. Alegret ...}, journal = {Electrochemical sensor analysis / edited by S. Alegret ...}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {978-0-444-53133-9}, pages = {e35 -- e44}, year = {2007}, language = {en} } @article{WagnerMarisAckermannetal.2007, author = {Wagner, Torsten and Maris, Rob J. and Ackermann, Hans-Josef and Otto, Ralph and Beging, Stefan and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Handheld measurement device for field-effect sensor structures: Practical evaluation and limitations}, series = {Sensors and Actuators B: Chemical . 127 (2007), H. 1}, journal = {Sensors and Actuators B: Chemical . 127 (2007), H. 1}, isbn = {0925-4005}, pages = {217 -- 223}, year = {2007}, language = {en} } @article{ChristiaensAbouzarPoghossianetal.2007, author = {Christiaens, P. and Abouzar, Maryam H. and Poghossian, Arshak and Wagner, Torsten and Bijnens, N. and Williams, O. A. and Daenen, M. and Haenen, K. and Douth{\´e}ret, O. and Haen, J. d´ and Mekhalif, Z. and Sch{\"o}ning, Michael Josef and Wagner, P.}, title = {pH sensitivity of nanocrystalline diamond films}, series = {Physica status solidi (A). 204 (2007), H. 9}, journal = {Physica status solidi (A). 204 (2007), H. 9}, isbn = {0031-8965}, pages = {2925 -- 2930}, year = {2007}, language = {en} } @article{AbouzarIngebrandtPoghossianetal.2009, author = {Abouzar, Maryam H. and Ingebrandt, S. and Poghossian, Arshak and Zhang, Y. and Moritz, W. and Sch{\"o}ning, Michael Josef}, title = {Field-effect nanoplate capacitive pH sensor based on SOI structure}, series = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, journal = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, pages = {55 -- 58}, year = {2009}, language = {en} } @article{SchoeningPoghossian2009, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {Silicon-based field-effect devices with nanostructured surfaces for bio-/chemical sensing}, series = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, journal = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, pages = {51 -- 53}, year = {2009}, language = {en} } @article{BuniatyanMatirosyanAbouzaretal.2009, author = {Buniatyan, V. V. and Matirosyan, N. W. and Abouzar, Maryam H. and Sch{\"o}ning, Michael Josef and Poghossian, Arshak and Schubert, J. and Khachatryan, V. R. and Soukiassyan, G. R.}, title = {(Ba,Sr)TiO3 based electrolyte-insulator-semiconductor pHsensors: comparitive study}, series = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, journal = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, pages = {71 -- 74}, year = {2009}, language = {en} } @article{WagnerWernerMiyamotoetal.2012, author = {Wagner, Torsten and Werner, Frederik and Miyamoto, Ko-Ichiro and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Development and characterisation of a compact light-addressable potentiometric sensor (LAPS) based on the digital light processing (DLP) technology for flexible chemical imaging}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2010.12.003}, pages = {34 -- 39}, year = {2012}, abstract = {Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach to read out light-addressable potentiometric sensors (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device, which allows fast and flexible generation of light patterns. With the help of these light patterns, the sensor surface of the LAPS device can be addressed. The DLP approach has several advantages compared to conventional LAPS set-ups, e.g., the spot size and the shape of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of the measurement. In addition, the modulation frequency and intensity of the light beam are important parameters of the LAPS set-up. Within this work, the authors will discuss two different ways of light modulation by the DLP set-up, investigate the influence of different modulation frequencies and different light intensities as well as demonstrate the scanning capabilities of the new set-up by pH mapping on the sensor surface.}, language = {en} } @article{WernerSchusserSpalthahnetal.2011, author = {Werner, Frederik and Schusser, Sebastian and Spalthahn, Heiko and Wagner, Torsten and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {Field-programmable gate array based controller for multi spot light-addressable potentiometric sensors with integrated signal correction mode}, series = {Electrochimica Acta}, volume = {56}, journal = {Electrochimica Acta}, number = {26}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0013-4686}, doi = {10.1016/j.electacta.2011.03.012}, pages = {9656 -- 9660}, year = {2011}, abstract = {A light-addressable potentiometric sensor (LAPS) can measure the concentration of one or several analytes at the sensor surface simultaneously in a spatially resolved manner. A modulated light pointer stimulates the semiconductor structure at the area of interest and a responding photocurrent can be read out. By simultaneous stimulation of several areas with light pointers of different modulation frequencies, the read out can be performed at the same time. With the new proposed controller electronic based on a field-programmable gate array (FPGA), it is possible to control the modulation frequencies, phase shifts, and light brightness of multiple light pointers independently and simultaneously. Thus, it is possible to investigate the frequency response of the sensor, and to examine the analyte concentration by the determination of the surface potential with the help of current/voltage curves and phase/voltage curves. Additionally, the ability to individually change the light intensities of each light pointer is used to perform signal correction.}, language = {en} } @article{PaczkowskiWeissbeckerSchoeningetal.2011, author = {Paczkowski, Sebastian and Weißbecker, Bernhard and Sch{\"o}ning, Michael Josef and Sch{\"u}tz, Stefan}, title = {Biosensors on the Basis of Insect Olfaction}, series = {Insect biotechnology / Andreas Vilcinskas, ed.}, journal = {Insect biotechnology / Andreas Vilcinskas, ed.}, publisher = {Springer}, address = {Dordrecht [u.a.]}, isbn = {978-90-481-9640-1}, pages = {225 -- 240}, year = {2011}, language = {en} } @article{BohrnStuetzFleischeretal.2011, author = {Bohrn, Ulrich and St{\"u}tz, Evamaria and Fleischer, Maximilian and Sch{\"o}ning, Michael Josef and Wagner, Patrick}, title = {Eukaryotic cell lines as a sensitive layer for direct monitoring of carbon monoxide}, series = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, journal = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, publisher = {Wiley}, address = {Weinheim}, isbn = {1862-6319}, pages = {1345 -- 1350}, year = {2011}, language = {en} } @article{BaeckerPouyeshmanSchnitzleretal.2011, author = {B{\"a}cker, Matthias and Pouyeshman, S. and Schnitzler, Thomas and Poghossian, Arshak and Wagner, Patrick and Biselli, Manfred and Sch{\"o}ning, Michael Josef}, title = {A silicon-based multi-sensor chip for monitoring of fermentation processes}, series = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, journal = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, publisher = {Wiley}, address = {Weinheim}, isbn = {1862-6319}, pages = {1364 -- 1369}, year = {2011}, language = {en} } @article{WernerKrumbeSchumacheretal.2011, author = {Werner, Frederik and Krumbe, Christoph and Schumacher, Katharina and Groebel, Simone and Spelthahn, Heiko and Stellberg, Michael and Wagner, Torsten and Yoshinobu, Tatsuo and Selmer, Thorsten and Keusgen, Michael and Baumann, Marcus and Sch{\"o}ning, Michael Josef}, title = {Determination of the extracellular acidification of Escherichia coli by a light-addressable potentiometric sensor}, series = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, journal = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, publisher = {Wiley}, address = {Weinheim}, isbn = {1862-6319}, pages = {1340 -- 1344}, year = {2011}, language = {en} } @article{KirchnerOberlaenderFriedrichetal.2011, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Friedrich, Peter and Berger, J{\"o}rg and Suso, Henri-Pierre and Kupyna, Andriy and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Optimisation and fabrication of a calorimetric gas sensor built up on a polyimide substrate for H2O2 monitoring}, series = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, journal = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, publisher = {Wiley}, address = {Weinheim}, isbn = {1862-6319}, pages = {1235 -- 1240}, year = {2011}, language = {en} } @article{AbouzarWernerSchoeningetal.2011, author = {Abouzar, Maryam H. and Werner, Moritz and Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {Capacitance-voltage and impedance-spectroscopy characteristics of nanoplate EISOI capacitors}, series = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, journal = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, publisher = {Wiley-VCH}, address = {Berlin}, isbn = {1862-6319}, pages = {1327 -- 1332}, year = {2011}, language = {en} } @article{ReisertGeisslerFloerkeetal.2011, author = {Reisert, Steffen and Geissler, Hanno and Fl{\"o}rke, Rudolf and N{\"a}ther, Niko and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Towards a multi-sensor system for the evaluation of aseptic processes employing hydrogen peroxide vapour (H2O2)}, series = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, journal = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, publisher = {Wiley}, address = {Weinheim}, isbn = {1862-6319}, pages = {1351 -- 1356}, year = {2011}, language = {en} } @article{PoghossianWagnerSchoening2011, author = {Poghossian, Arshak and Wagner, Holger and Sch{\"o}ning, Michael Josef}, title = {Functional testing and characterisation of (bio-)chemical sensors on wafer level}, series = {Sensors and Actuators B: Chemical. 154 (2011), H. 2}, journal = {Sensors and Actuators B: Chemical. 154 (2011), H. 2}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1873-3077}, pages = {169 -- 173}, year = {2011}, language = {en} } @article{WagnerMiyamotoShigiharaetal.2011, author = {Wagner, Torsten and Miyamoto, Ko-ichiro and Shigihara, Noriko and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Microfluidic systems with free definable sensor spots by an integrated light-addressable potentiometric sensor}, series = {Procedia Engineering. 25 (2011)}, journal = {Procedia Engineering. 25 (2011)}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1877-7058}, pages = {791 -- 794}, year = {2011}, language = {en} } @article{WernerWagnerMiyamotoetal.2011, author = {Werner, Frederik and Wagner, Torsten and Miyamoto, Ko-ichiro and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {High speed and high resolution chemical imaging based on a new type of OLED-LAPS set-up}, series = {Procedia Engineering. 25 (2011)}, journal = {Procedia Engineering. 25 (2011)}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1877-7058}, pages = {346 -- 349}, year = {2011}, language = {en} } @article{MiyamotoKanekoMatsuoetal.2012, author = {Miyamoto, Ko-ichiro and Kaneko, Kazumi and Matsuo, Akira and Wagner, Torsten and Kanoh, Shin{\´i}chiro and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Miniaturized chemical imaging sensor system using an OLED display panel}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2011.02.029}, pages = {82 -- 87}, year = {2012}, abstract = {The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current-voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.}, language = {en} } @article{SchusserPoghossianBaeckeretal.2012, author = {Schusser, Sebastian and Poghossian, Arshak and B{\"a}cker, Matthias and Leinhos, Marcel and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Characterization of biodegradable polymers with capacitive field-effect sensors}, series = {Sensors and actuators B: Chemical}, volume = {187}, journal = {Sensors and actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2012.07.099}, pages = {2 -- 7}, year = {2012}, abstract = {In vitro studies of the degradation kinetic of biopolymers are essential for the design and optimization of implantable biomedical devices. In the presented work, a field-effect capacitive sensor has been applied for the real-time and in situ monitoring of degradation processes of biopolymers for the first time. The polymer-covered field-effect sensor is, in principle, capable to detect any changes in bulk, surface and interface properties of the polymer induced by degradation processes. The feasibility of this approach has been experimentally proven by using the commercially available biomedical polymer poly(D,L-lactic acid) (PDLLA) as a model system. PDLLA films of different thicknesses were deposited on the Ta₂O₅-gate surface of the field-effect structure from a polymer solution by means of spin-coating method. The polymer-modified field-effect sensors have been characterized by means of capacitance-voltage and impedance-spectroscopy method. The degradation of the PDLLA was accelerated by changing the degradation medium from neutral (pH 7.2) to alkaline (pH 9) condition, resulting in drastic changes in the capacitance and impedance spectra of the polymer-modified field-effect sensor.}, language = {en} } @article{KirchnerOberlaenderFriedrichetal.2012, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Friedrich, Peter and Berger, J{\"o}rg and Rysstad, Gunnar and Sch{\"o}ning, Michael Josef and Keusgen, Michael}, title = {Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2011.01.032}, pages = {60 -- 66}, year = {2012}, abstract = {A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(\%, v/v) in a H2O2 concentration range of 0\%, v/v to 8\%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes.}, language = {en} } @article{IkenKirsanovLeginetal.2012, author = {Iken, Heiko and Kirsanov, D. and Legin, A. and Sch{\"o}ning, Michael Josef}, title = {Novel Thin-Film Polymeric Materials for the Detection of Heavy Metals}, series = {Procedia Engineering}, journal = {Procedia Engineering}, number = {47}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2012.09.148}, pages = {322 -- 325}, year = {2012}, abstract = {A variety of transition metals, e.g., copper, zinc, cadmium, lead, etc. are widely used in industry as components for wires, coatings, alloys, batteries, paints and so on. The inevitable presence of transition metals in industrial processes implies the ambition of developing a proper analytical technique for their adequate monitoring. Most of these elements, especially lead and cadmium, are acutely toxic for biological organisms. Quantitative determination of these metals at low activity levels in different environmental and industrial samples is therefore a vital task. A promising approach to achieve an at-side or on-line monitoring on a miniaturized and cost efficient way is the combination of a common potentiometric sensor array with heavy metal-sensitive thin-film materials, like chalcogenide glasses and polymeric materials, respectively.}, language = {en} } @article{MiyamotoIchimuraWagneretal.2012, author = {Miyamoto, K. and Ichimura, H. and Wagner, Torsten and Yoshinobu, T. and Sch{\"o}ning, Michael Josef}, title = {Chemical Imaging of ion Diffusion in a Microfluidic Channel}, series = {Procedia Engineering}, journal = {Procedia Engineering}, number = {47}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2012.09.289}, pages = {886 -- 889}, year = {2012}, abstract = {The chemical imaging sensor is a chemical sensor which is capable of visualizing the spatial distribution of chemical species in sample solution. In this study, a novel measurement system based on the chemical imaging sensor was developed to observe the inside of a Y-shaped microfluidic channel while injecting two sample solutions from two branches. From the collected chemical images, it was clearly observed that the injected solutions formed laminar flows in the microfluidic channel. In addition, ion diffusion across the laminar flows was observed. This label-free method can acquire quantitative data of ion distribution and diffusion in microfluidic devices, which can be used to determine the diffusion coefficients, and therefore, the molecular weights of chemical species in the sample solution.}, language = {en} } @article{WagnerShigiaharaMiyamotoetal.2012, author = {Wagner, Torsten and Shigiahara, N. and Miyamoto, K. and Suzurikawa, J. and Finger, F. and Sch{\"o}ning, Michael Josef and Yoshinobu, T.}, title = {Light-addressable Potentiometric Sensors and Light-addressable Electrodes as a Combined Sensor-and-manipulator Microsystem with High Flexibility}, series = {Procedia Engineering}, journal = {Procedia Engineering}, number = {47}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2012.09.290}, pages = {890 -- 893}, year = {2012}, abstract = {This work describes the novel combination of the light-addressable electrode (LAE) and the light-addressable potentiometric sensor (LAPS) into a microsystem set-up. Both the LAE as well as the LAPS shares the principle of addressing the active spot by means of a light beam. This enables both systems to manipulate resp. to detect an analyte with a high spatial resolution. Hence, combining both principles into a single set-up enables the active stimulation e.g., by means of electrolysis and a simultaneous observation e.g., the response of an entrapped biological cell by detection of extracellular pH changes. The work will describe the principles of both technologies and the necessary steps to integrate them into a single set-up. Furthermore, examples of application and operation of such systems will be presented.}, language = {en} } @article{PoghossianWeilBaeckeretal.2012, author = {Poghossian, Arshak and Weil, M. H. and B{\"a}cker, Matthias and Mayer, D. and Sch{\"o}ning, Michael Josef}, title = {Field-effect Devices Functionalised with Gold-Nanoparticle/Macromolecule Hybrids: New Opportunities for a Label-Free Biosensing}, series = {Procedia Engineering}, journal = {Procedia Engineering}, number = {47}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2012.09.136}, pages = {273 -- 276}, year = {2012}, abstract = {Field-effect capacitive electrolyte-insulator-semiconductor (EIS) sensors functionalised with citrate-capped gold nanoparticles (AuNP) have been used for the electrostatic detection of macromolecules by their intrinsic molecular charge. The EIS sensor detects the charge changes in the AuNP/macromolecule hybrids induced by the adsorption or binding events. A feasibility of the proposed detection scheme has been exemplary demonstrated by realising EIS sensors for the detection of poly-D-lysine molecules.}, language = {en} } @article{MuribTranCeunincketal.2012, author = {Murib, Mohammed S. and Tran, Anh Quang and Ceuninck, Ward de and Sch{\"o}ning, Michael Josef and Nesladek, Milos and Serpeng{\"u}zel, Ali and Wagner, Patrick}, title = {Analysis of an optical biosensor based on elastic light scattering from diamond-, glass-, and sapphire microspheres}, series = {Physica Status Solidi A}, volume = {209}, journal = {Physica Status Solidi A}, number = {9}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100795}, pages = {1804 -- 1810}, year = {2012}, abstract = {Deoxyribonucleic acid (DNA) and protein recognition are now standard tools in biology. In addition, the special optical properties of microsphere resonators expressed by the high quality factor (Q-factor) of whispering gallery modes (WGMs) or morphology dependent resonances (MDRs) have attracted the attention of the biophotonic community. Microsphere-based biosensors are considered as powerful candidates to achieve label-free recognition of single molecules due to the high sensitivity of their WGMs. When the microsphere surface is modified with biomolecules, the effective refractive index and the effective size of the microsphere change resulting in a resonant wavelength shift. The transverse electric (TE) and the transverse magnetic (TM) elastic light scattering intensity of electromagnetic waves at 600 and 1400 nm are numerically calculated for DNA and unspecific binding of proteins to the microsphere surface. The effect of changing the optical properties was studied for diamond (refractive index 2.34), glass (refractive index 1.50), and sapphire (refractive index 1.75) microspheres with a 50 µm radius. The mode spacing, the linewidth of WGMs, and the shift of resonant wavelength due to the change in radius and refractive index, were analyzed by numerical simulations. Preliminary results of unspecific binding of biomolecules are presented. The calculated shift in WGMs can be used for biomolecules detection.}, language = {en} } @article{HuckPoghossianWagneretal.2012, author = {Huck, Christina and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Combined amperometric/field-effect sensor for the detection of dissolved hydrogen}, series = {Sensors and actuators B: Chemical}, volume = {187}, journal = {Sensors and actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2012.10.050}, pages = {168 -- 173}, year = {2012}, abstract = {Real-time and reliable monitoring of the biogas process is crucial for a stable and efficient operation of biogas production in order to avoid digester breakdowns. The concentration of dissolved hydrogen (H₂) represents one of the key parameters for biogas process control. In this work, a one-chip integrated combined amperometric/field-effect sensor for monitoring the dissolved H₂ concentration has been developed for biogas applications. The combination of two different transducer principles might allow a more accurate and reliable measurement of dissolved H₂ as an early warning indicator of digester failures. The feasibility of the approach has been demonstrated by simultaneous amperometric/field-effect measurements of dissolved H₂ concentrations in electrolyte solutions. Both, the amperometric and the field-effect transducer show a linear response behaviour in the H₂ concentration range from 0.1 to 3\% (v/v) with a slope of 198.4 ± 13.7 nA/\% (v/v) and 14.9 ± 0.5 mV/\% (v/v), respectively.}, language = {en} } @article{BohrnStuetzFleischeretal.2013, author = {Bohrn, Ulrich and St{\"u}tz, Evamaria and Fleischer, Maximilian and Sch{\"o}ning, Michael Josef and Wagner, Patrick}, title = {Using a cell-based gas biosensor for investigation of adverse effects of acetone vapors in vitro}, series = {Biosensors and Bioelectronics. 40 (2013), H. 1}, journal = {Biosensors and Bioelectronics. 40 (2013), H. 1}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0956-5663}, pages = {393 -- 400}, year = {2013}, language = {en} } @article{HennemannKohlReisertetal.2013, author = {Hennemann, J{\"o}rg and Kohl, Claus-Dieter and Reisert, Steffen and Kirchner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Copper oxide nanofibres for detection of hydrogen peroxide vapour at high concentrations}, series = {physica status solidi (a)}, volume = {210}, journal = {physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201200775}, pages = {859 -- 863}, year = {2013}, abstract = {We present a sensor concept based on copper(II)oxide (CuO) nanofibres for the detection of hydrogen peroxide (H2O2) vapour in the percent per volume (\% v/v) range. The fibres were produced by using the electrospinning technique. To avoid water condensation in the pores, the fibres were initially modified by an exposure to H2S to get an enclosed surface. By a thermal treatment at 350 °C the fibres were oxidised back to CuO. Thereby, the visible pores disappear which was verified by SEM analysis. The fibres show a decrease of resistance with increasing H2O2 concentration which is due to the fact that hydrogen peroxide is an oxidising gas and CuO a p-type semiconductor. The sensor shows a change of resistance within the minute range to the exposure until the maximum concentration of 6.9\% v/v H2O2. At operating temperatures below 450 °C the corresponding sensor response to a concentration of 4.1\% v/v increases. The sensor shows a good reproducibility of the signal at different measurements. CuO seems to be a suitable candidate for the detection of H2O2 vapour at high concentrations. Resistance behaviour of the sensor under exposure to H2O2 vapours between 2.3 and 6.9\% v/v at an operating temperature of 450 °C.}, language = {en} } @article{ReisertSchneiderGeissleretal.2013, author = {Reisert, Steffen and Schneider, Benno and Geissler, Hanno and Gompel, Matthias van and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Multi-sensor chip for the investigation of different types of metal oxides for the detection of H2O2 in the ppm range}, series = {physica status solidi (a)}, volume = {210}, journal = {physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, pages = {898 -- 904}, year = {2013}, abstract = {In this work, a multi-sensor chip for the investigation of the sensing properties of different types of metal oxides towards hydrogen peroxide in the ppm range is presented. The fabrication process and physical characterization of the multi-sensor chip are described. Pure SnO2 and WO3 as well as Pd- and Pt-doped SnO2 films are characterized in terms of their sensitivity to H2O2. The sensing films have been prepared by drop-coating of water-dispensed nano-powders. A physical characterization, including scanning electron microscopy and X-ray diffraction analysis of the deposited metal-oxide films, was done. From the measurements in hydrogen peroxide atmosphere, it could be shown, that all of the tested metal oxide films are suitable for the detection of H2O2 in the ppm range. The highest sensitivity and reproducibility was achieved using Pt-doped SnO2. Calibration plot of a SnO2, WO3, Pt-, and Pd-doped SnO2 gas sensor for H2O2 concentrations in the ppm range.}, language = {en} } @article{KirchnerOberlaenderSusoetal.2013, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Suso, Henri-Pierre and Rysstad, Gunnar and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes}, series = {Physica status solidi (a)}, volume = {210}, journal = {Physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201200920}, pages = {877 -- 883}, year = {2013}, abstract = {A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests.}, language = {en} } @article{MiyamotoIchimuraWagneretal.2013, author = {Miyamoto, Ko-ichiro and Ichimura, Hiroki and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel}, series = {Sensors and actuators. B: Chemical}, volume = {189}, journal = {Sensors and actuators. B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077 (E-Journal); 0925-4005 (Print)}, doi = {10.1016/j.snb.2013.04.057}, pages = {240 -- 245}, year = {2013}, abstract = {The chemical imaging sensor is a device to visualize the spatial distribution of chemical species based on the principle of LAPS (light-addressable potentiometric sensor), which is a field-effect chemical sensor based on semiconductor. In this study, the chemical imaging sensor has been applied to investigate the ion profile of laminar flows in a microfluidic channel. The chemical images (pH maps) were collected in a Y-shaped microfluidic channel while injecting HCl and NaCl solutions into two branches. From the chemical images, it was clearly observed that the injected solutions formed laminar flows in the channel. In addition, ion diffusion across the laminar flows was observed, and the diffusion coefficient could be derived by fitting the pH profiles to the Fick's equation.}, language = {en} } @article{BohrnMuchaWerneretal.2013, author = {Bohrn, Ulrich and Mucha, Andreas and Werner, Frederik and Trattner, Barbara and B{\"a}cker, Matthias and Krumbe, Christoph and Schienle, Meinrad and St{\"u}tz, Evamaria and Schmitt-Landsiedel, Doris and Fleischer, Maximilian and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {A critical comparison of cell-based sensor systems for the detection of Cr (VI) in aquatic environment}, series = {Sensors and actuators. B: Chemical}, volume = {Vol. 182}, journal = {Sensors and actuators. B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077 (E-Journal); 0925-4005 (Print)}, pages = {58 -- 65}, year = {2013}, language = {en} } @article{KramerHalamkovaPoghossianetal.2013, author = {Kramer, Friederike and Halamkova, Lenka and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Katz, Evgeny and Halamek, Jan}, title = {Biocatalytic analysis of biomarkers for forensic identification of ethnicity between Caucasian and African American}, series = {The analyst. August 2013}, volume = {Vol. 138}, journal = {The analyst. August 2013}, publisher = {Royal Society of Chemistry}, address = {Cambridge}, issn = {1364-5528 (E-Journal); 0003-2654 (Print)}, pages = {6251 -- 6257}, year = {2013}, language = {en} } @article{VitusevichFoersterLuethetal.2001, author = {Vitusevich, S. A. and F{\"o}rster, Arnold and L{\"u}th, H. and Belyaev, A. E. and Danylyuk, S. V. and Konakova, R. V. and Sheka, D. I.}, title = {Resonant spectroscopy of electric-field-induced superlattices}, series = {Journal of Applied Physics. 90 (2001), H. 6}, journal = {Journal of Applied Physics. 90 (2001), H. 6}, isbn = {1089-7550}, doi = {10.1063/1.1392956}, pages = {2857 -- 2861}, year = {2001}, language = {en} } @article{StockMalindretosIndlekoferetal.2001, author = {Stock, J. and Malindretos, J. and Indlekofer, K.M. and P{\"o}ttgens, Michael and F{\"o}rster, Arnold and L{\"u}th, Hans}, title = {A Vertical Resonant Tunneling Transistor for Application in Digital Logic Circuits}, series = {IEEE Transactions on Electron Devices (T-ED). 48 (2001), H. 6}, journal = {IEEE Transactions on Electron Devices (T-ED). 48 (2001), H. 6}, isbn = {0018-9383}, pages = {1028 -- 1032}, year = {2001}, language = {en} } @article{HodelOrzatiMarsoetal.2000, author = {Hodel, U. and Orzati, A. and Marso, M. and Homann, O. and Fox, A. and Hart, A. v. d. and F{\"o}rster, Arnold and Kordos, P. and L{\"u}th, H.}, title = {A novel InAlAs/InGaAs layer structure for monolithically integrated photoreceiver}, series = {Conference Proceedings: 2000 International Conference on Indium Phosphide and related materials}, journal = {Conference Proceedings: 2000 International Conference on Indium Phosphide and related materials}, publisher = {IEEE Service Center}, address = {Piscataway, NJ}, isbn = {0-7803-6320-5}, pages = {466 -- 469}, year = {2000}, language = {en} } @article{HoskensRoerTolstikhinetal.2000, author = {Hoskens, R.C.P. and Roer, T.G. van de and Tolstikhin, V.I. and F{\"o}rster, Arnold}, title = {Hot electron injection laser: vertically integrated transistor-laser structure for high-speed, low-chirp direct modulation}, series = {LEOS 2000 : 2000 IEEE annual meeting conference proceedings; 13th annual meeting; IEEE Lasers and Electro-Optics Society 2000 annual meeting; 13-16 November 2000, The Westin Rio Mar Beach, Rio Grande, Puerto Rico. Vol. 2}, journal = {LEOS 2000 : 2000 IEEE annual meeting conference proceedings; 13th annual meeting; IEEE Lasers and Electro-Optics Society 2000 annual meeting; 13-16 November 2000, The Westin Rio Mar Beach, Rio Grande, Puerto Rico. Vol. 2}, publisher = {IEEE Service Center}, address = {Piscataway, NJ}, isbn = {0-7803-5947-X}, pages = {444 -- 445}, year = {2000}, language = {en} } @article{HoskensTolstikhinFoersteretal.2000, author = {Hoskens, R. C. P. and Tolstikhin, V.I. and F{\"o}rster, Arnold and Roer, T.G. van de}, title = {Vertically integrated transistor-laser structure, take 2}, series = {WOCSDICE 2000, 24th Workshop on Compound Semiconductor Devices and Integrated Circuits held in Europe : May 29 - June 02, 2000, Aegean Sea, Greece.}, journal = {WOCSDICE 2000, 24th Workshop on Compound Semiconductor Devices and Integrated Circuits held in Europe : May 29 - June 02, 2000, Aegean Sea, Greece.}, publisher = {Univ. of Michigan}, address = {Ann Arbor, Mich.}, isbn = {0970311109}, pages = {Getr. Z{\"a}hlung [ca. 200 S.]}, year = {2000}, language = {en} } @article{DarmoSchaefferFoersteretal.2000, author = {Darmo, J. and Sch{\"a}ffer, F. and F{\"o}rster, Arnold and Kordos, P.}, title = {Beryllium doped low-temperature-grown MBE GaAs: material for photomixing in the THz frequency range}, series = {ASDAM 2000 : conference proceedings / edited by Jozef Osvald ... [et al.]}, journal = {ASDAM 2000 : conference proceedings / edited by Jozef Osvald ... [et al.]}, publisher = {IEEE}, address = {Piscataway, NJ}, isbn = {0780359399}, pages = {147 -- 150}, year = {2000}, language = {en} } @article{SchmidtTonnesmannFoersteretal.2000, author = {Schmidt, R. and Tonnesmann, A. and F{\"o}rster, Arnold and Grimm, M. and Kordos, P. and L{\"u}th, H.}, title = {Metamorphic InAlAs/InGaAs HEMT's on GaAs substrates using an InP buffer layer}, series = {8th IEEE International Symposium on High Performance Electron Devices for Microwave and Optoelectronic Applications : EDMO 2000 ; [13 - 14 November 2000, University of Glasgow] / organised by Department of Electronics and Electrical Engineering, University of Glasgow, Glasgow Scotland. MTT/ED/AP/LEO Societies Joint Chapter, United Kingdom and Republic of Ireland Section. With technical co-sponsorship from IEEE Electron Device Society}, journal = {8th IEEE International Symposium on High Performance Electron Devices for Microwave and Optoelectronic Applications : EDMO 2000 ; [13 - 14 November 2000, University of Glasgow] / organised by Department of Electronics and Electrical Engineering, University of Glasgow, Glasgow Scotland. MTT/ED/AP/LEO Societies Joint Chapter, United Kingdom and Republic of Ireland Section. With technical co-sponsorship from IEEE Electron Device Society}, publisher = {IEEE Operations Center}, address = {Piscataway, NJ}, isbn = {0-7803-6550-X}, pages = {95 -- 98}, year = {2000}, language = {en} } @article{VitusevichFoersterReetzetal.2000, author = {Vitusevich, S. A. and F{\"o}rster, Arnold and Reetz, W. and L{\"u}th, H. and Belyaev, A. E. and Danylyuk, S. V.}, title = {Fine structure of photoresponse spectra in a double-barrier resonant tunnelling diode}, series = {Nanotechnology. 11 (2000), H. 4}, journal = {Nanotechnology. 11 (2000), H. 4}, isbn = {1361-6528}, pages = {305 -- 308}, year = {2000}, language = {en} }