@article{KarschuckPoghossianSeretal.2024, author = {Karschuck, Tobias and Poghossian, Arshak and Ser, Joey and Tsokolakyan, Astghik and Achtsnicht, Stefan and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Capacitive model of enzyme-modified field-effect biosensors: Impact of enzyme coverage}, series = {Sensors and Actuators B: Chemical}, volume = {408}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005 (Print)}, doi = {10.1016/j.snb.2024.135530}, pages = {12 Seiten}, year = {2024}, abstract = {Electrolyte-insulator-semiconductor capacitors (EISCAP) belong to field-effect sensors having an attractive transducer architecture for constructing various biochemical sensors. In this study, a capacitive model of enzyme-modified EISCAPs has been developed and the impact of the surface coverage of immobilized enzymes on its capacitance-voltage and constant-capacitance characteristics was studied theoretically and experimentally. The used multicell arrangement enables a multiplexed electrochemical characterization of up to sixteen EISCAPs. Different enzyme coverages have been achieved by means of parallel electrical connection of bare and enzyme-covered single EISCAPs in diverse combinations. As predicted by the model, with increasing the enzyme coverage, both the shift of capacitance-voltage curves and the amplitude of the constant-capacitance signal increase, resulting in an enhancement of analyte sensitivity of the EISCAP biosensor. In addition, the capability of the multicell arrangement with multi-enzyme covered EISCAPs for sequentially detecting multianalytes (penicillin and urea) utilizing the enzymes penicillinase and urease has been experimentally demonstrated and discussed.}, language = {en} } @article{KarschuckSchmidtAchtsnichtetal.2023, author = {Karschuck, Tobias and Schmidt, Stefan and Achtsnicht, Stefan and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Multiplexing system for automated characterization of a capacitive field-effect sensor array}, series = {Physica Status Solidi A}, volume = {220}, journal = {Physica Status Solidi A}, number = {22}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6300 (Print)}, doi = {10.1002/pssa.202300265}, pages = {7 Seiten}, year = {2023}, abstract = {In comparison to single-analyte devices, multiplexed systems for a multianalyte detection offer a reduced assay time and sample volume, low cost, and high throughput. Herein, a multiplexing platform for an automated quasi-simultaneous characterization of multiple (up to 16) capacitive field-effect sensors by the capacitive-voltage (C-V) and the constant-capacitance (ConCap) mode is presented. The sensors are mounted in a newly designed multicell arrangement with one common reference electrode and are electrically connected to the impedance analyzer via the base station. A Python script for the automated characterization of the sensors executes the user-defined measurement protocol. The developed multiplexing system is tested for pH measurements and the label-free detection of ligand-stabilized, charged gold nanoparticles.}, language = {en} } @article{KassabHanPoghossianetal.2004, author = {Kassab, T. and Han, Y. and Poghossian, Arshak and Ingebrandt, S. and Offenh{\"a}usser, A. and Sch{\"o}ning, Michael Josef}, title = {Detection of layerby-layer adsorbed polyelectrolytes by means of field-effect based capacitive EIS structures}, series = {Biomedizinische Technik. 49 (2004), H. 2}, journal = {Biomedizinische Technik. 49 (2004), H. 2}, isbn = {0932-4666}, pages = {1034 -- 1035}, year = {2004}, language = {en} } @inproceedings{KatzWillner2006, author = {Katz, Eugenii and Willner, Itamar}, title = {Magneto-controlled quantized electron transfer to surface-confined redox units and metal nanoparticles}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1528}, year = {2006}, abstract = {Hydrophobic magnetic nanoparticles (NPs) consisting of undecanoate-capped magnetite (Fe3O4, average diameter ca. 5 nm) are used to control quantized electron transfer to surface-confined redox units and metal NPs. A two-phase system consisting of an aqueous electrolyte solution and a toluene phase that includes the suspended undecanoatecapped magnetic NPs is used to control the interfacial properties of the electrode surface. The attracted magnetic NPs form a hydrophobic layer on the electrode surface resulting in the change of the mechanisms of the surface-confined electrochemical processes. A quinone-monolayer modified Au electrode demonstrates an aqueous-type of the electrochemical process (2e-+2H+ redox mechanism) for the quinone units in the absence of the hydrophobic magnetic NPs, while the attraction of the magnetic NPs to the surface results in the stepwise single-electron transfer mechanism characteristic of a dry nonaqueous medium. Also, the attraction of the hydrophobic magnetic NPs to the Au electrode surface modified with Au NPs (ca. 1.4 nm) yields a microenvironment with a low dielectric constant that results in the single-electron quantum charging of the Au NPs.}, subject = {Biosensor}, language = {en} } @article{KatzPoghossianSchoening2017, author = {Katz, Evgeny and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Enzyme-based logic gates and circuits - analytical applications and interfacing with electronics}, series = {Analytical and Bioanalytical Chemistry}, volume = {409}, journal = {Analytical and Bioanalytical Chemistry}, publisher = {Springer}, address = {Berlin}, issn = {1618-2650}, doi = {10.1007/s00216-016-0079-7}, pages = {81 -- 94}, year = {2017}, abstract = {The paper is an overview of enzyme-based logic gates and their short circuits, with specific examples of Boolean AND and OR gates, and concatenated logic gates composed of multi-step enzyme-biocatalyzed reactions. Noise formation in the biocatalytic reactions and its decrease by adding a "filter" system, converting convex to sigmoid response function, are discussed. Despite the fact that the enzyme-based logic gates are primarily considered as components of future biomolecular computing systems, their biosensing applications are promising for immediate practical use. Analytical use of the enzyme logic systems in biomedical and forensic applications is discussed and exemplified with the logic analysis of biomarkers of various injuries, e.g., liver injury, and with analysis of biomarkers characteristic of different ethnicity found in blood samples on a crime scene. Interfacing of enzyme logic systems with modified electrodes and semiconductor devices is discussed, giving particular attention to the interfaces functionalized with signal-responsive materials. Future perspectives in the design of the biomolecular logic systems and their applications are discussed in the conclusion.}, language = {en} } @article{KaulKoshkaryevArtmannetal.2008, author = {Kaul, D. K. and Koshkaryev, A. and Artmann, Gerhard and Barshtein, G. and Yedgar, S.}, title = {Additive effect of red blood cell rigidity and adherence to endothelial cells in inducing vascular resistance}, series = {American Journal of Physiology : Heart and Circulation Physiology . 295 (2008), H. 4}, volume = {295}, journal = {American Journal of Physiology : Heart and Circulation Physiology . 295 (2008), H. 4}, number = {4}, issn = {1522-1539}, pages = {H1788 -- H1793}, year = {2008}, language = {en} } @article{KaulenSchwabedalSchneideretal.2022, author = {Kaulen, Lars and Schwabedal, Justus T. C. and Schneider, Jules and Ritter, Philipp and Bialonski, Stephan}, title = {Advanced sleep spindle identification with neural networks}, series = {Scientific Reports}, volume = {12}, journal = {Scientific Reports}, number = {Article number: 7686}, publisher = {Springer Nature}, address = {London}, issn = {2045-2322}, doi = {10.1038/s41598-022-11210-y}, pages = {1 -- 10}, year = {2022}, abstract = {Sleep spindles are neurophysiological phenomena that appear to be linked to memory formation and other functions of the central nervous system, and that can be observed in electroencephalographic recordings (EEG) during sleep. Manually identified spindle annotations in EEG recordings suffer from substantial intra- and inter-rater variability, even if raters have been highly trained, which reduces the reliability of spindle measures as a research and diagnostic tool. The Massive Online Data Annotation (MODA) project has recently addressed this problem by forming a consensus from multiple such rating experts, thus providing a corpus of spindle annotations of enhanced quality. Based on this dataset, we present a U-Net-type deep neural network model to automatically detect sleep spindles. Our model's performance exceeds that of the state-of-the-art detector and of most experts in the MODA dataset. We observed improved detection accuracy in subjects of all ages, including older individuals whose spindles are particularly challenging to detect reliably. Our results underline the potential of automated methods to do repetitive cumbersome tasks with super-human performance.}, language = {en} } @phdthesis{Kelemen1999, author = {Kelemen, Christina}, title = {Analyse des phasensprungartigen Einsetzens der Passage humaner Erythrozyten durch Mikropipetten bei kritischen Temperaturen}, publisher = {Forschungszentrum, Zentralbibliothek}, address = {J{\"u}lich}, year = {1999}, language = {de} } @inproceedings{KernDikta2009, author = {Kern, Alexander and Dikta, Gerhard}, title = {Probability of damage of electrical and electronic systems due to indirect lightning flashes - investigation of data from German insurance companies}, year = {2009}, abstract = {In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not.}, subject = {Blitzschutz}, language = {en} } @article{KernSchelthoffMathieu2012, author = {Kern, Alexander and Schelthoff, Christof and Mathieu, Moritz}, title = {Detaillierte Berechnung der Einfangwirksamkeiten von Fangeinrichtungen}, series = {Elektro-Praktiker}, volume = {66}, journal = {Elektro-Praktiker}, number = {4}, publisher = {Huss Medien}, address = {Berlin}, issn = {0013-5569}, pages = {6 Seiten}, year = {2012}, abstract = {Im Beitrag wird zun{\"a}chst das Verfahren eines dynamischen elektro-geometrischen Modells vorgestellt. Dieses arbeitet im Gegensatz zum klassischen Blitzkugel-Verfahren nicht mit konstanten Radien; vielmehr wird der Radius der Blitzkugel variiert. Dabei werden ausschließlich vorhandene und in internationalen Normen anerkannte Ergebnisse, blitzphysikalische Grundlagen und Untersuchungen verwendet, und auf deren Grundlage ein numerisches Verfahren erarbeitet. Mit dem dynamischen elektro-geometrischen Modell werden dann einige Beispiele des Schutzes mit Fangstangen, die gem{\"a}ß dem klassischen Blitzkugel-Verfahren nach DIN EN 62305-3 f{\"u}r die Schutzklassen I - II - III - IV geplant sind, untersucht. Es wird gezeigt, dass die Einfangwirksamkeiten wesentlich h{\"o}her sind als in der Normenreihe DIN EN 62305 selbst angegeben. Grund daf{\"u}r ist die Tatsache, dass das Blitzkugel-Verfahren sehr konservativ aufgebaut ist und dem Planer von Blitzschutzsystemen nur die m{\"o}glichen Stellen f{\"u}r einen Einschlag aufzeigt, ohne eine Bewertung der Einschlagsh{\"a}ufigkeit zu liefern. Andererseits bedeutet dies jedoch, dass man mit dem klassischen Blitzkugel-Verfahren stets auf der „sicheren Seite" liegt.}, language = {de} } @article{KetelhutBrueggeGoelletal.2020, author = {Ketelhut, Maike and Br{\"u}gge, G. M. and G{\"o}ll, Fabian and Braunstein, Bjoern and Albracht, Kirsten and Abel, Dirk}, title = {Adaptive iterative learning control of an industrial robot during neuromuscular training}, series = {IFAC PapersOnLine}, volume = {53}, journal = {IFAC PapersOnLine}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2405-8963}, doi = {10.1016/j.ifacol.2020.12.741}, pages = {16468 -- 16475}, year = {2020}, abstract = {To prevent the reduction of muscle mass and loss of strength coming along with the human aging process, regular training with e.g. a leg press is suitable. However, the risk of training-induced injuries requires the continuous monitoring and controlling of the forces applied to the musculoskeletal system as well as the velocity along the motion trajectory and the range of motion. In this paper, an adaptive norm-optimal iterative learning control algorithm to minimize the knee joint loadings during the leg extension training with an industrial robot is proposed. The response of the algorithm is tested in simulation for patients with varus, normal and valgus alignment of the knee and compared to the results of a higher-order iterative learning control algorithm, a robust iterative learning control and a recently proposed conventional norm-optimal iterative learning control algorithm. Although significant improvements in performance are made compared to the conventional norm-optimal iterative learning control algorithm with a small learning factor, for the developed approach as well as the robust iterative learning control algorithm small steady state errors occur.}, language = {en} } @inproceedings{KetelhutGoellBraunsteinetal.2019, author = {Ketelhut, Maike and G{\"o}ll, Fabian and Braunstein, Bjoern and Albracht, Kirsten and Abel, Dirk}, title = {Iterative learning control of an industrial robot for neuromuscular training}, series = {2019 IEEE Conference on Control Technology and Applications}, booktitle = {2019 IEEE Conference on Control Technology and Applications}, publisher = {IEEE}, address = {New York}, isbn = {978-1-7281-2767-5 (ePub)}, doi = {10.1109/CCTA.2019.8920659}, pages = {7 Seiten}, year = {2019}, abstract = {Effective training requires high muscle forces potentially leading to training-induced injuries. Thus, continuous monitoring and controlling of the loadings applied to the musculoskeletal system along the motion trajectory is required. In this paper, a norm-optimal iterative learning control algorithm for the robot-assisted training is developed. The algorithm aims at minimizing the external knee joint moment, which is commonly used to quantify the loading of the medial compartment. To estimate the external knee joint moment, a musculoskeletal lower extremity model is implemented in OpenSim and coupled with a model of an industrial robot and a force plate mounted at its end-effector. The algorithm is tested in simulation for patients with varus, normal and valgus alignment of the knee. The results show that the algorithm is able to minimize the external knee joint moment in all three cases and converges after less than seven iterations.}, language = {en} } @article{KetelhutGoellBraunsteinetal.2018, author = {Ketelhut, Maike and G{\"o}ll, Fabian and Braunstein, Bj{\"o}rn and Albracht, Kirsten and Abel, Dirk}, title = {Comparison of different training algorithms for the leg extension training with an industrial robot}, series = {Current Directions in Biomedical Engineering}, volume = {4}, journal = {Current Directions in Biomedical Engineering}, number = {1}, publisher = {De Gruyter}, address = {Berlin}, issn = {2364-5504}, doi = {10.1515/cdbme-2018-0005}, pages = {17 -- 20}, year = {2018}, abstract = {In the past, different training scenarios have been developed and implemented on robotic research platforms, but no systematic analysis and comparison have been done so far. This paper deals with the comparison of an isokinematic (motion with constant velocity) and an isotonic (motion against constant weight) training algorithm. Both algorithms are designed for a robotic research platform consisting of a 3D force plate and a high payload industrial robot, which allows leg extension training with arbitrary six-dimensional motion trajectories. In the isokinematic as well as the isotonic training algorithm, individual paths are defined i n C artesian s pace by sufficient s upport p oses. I n t he i sotonic t raining s cenario, the trajectory is adapted to the measured force as the robot should only move along the trajectory as long as the force applied by the user exceeds a minimum threshold. In the isotonic training scenario however, the robot's acceleration is a function of the force applied by the user. To validate these findings, a simulative experiment with a simple linear trajectory is performed. For this purpose, the same force path is applied in both training scenarios. The results illustrate that the algorithms differ in the force dependent trajectory adaption.}, language = {en} } @article{KetelhutKolditzGoelletal.2019, author = {Ketelhut, Maike and Kolditz, Melanie and G{\"o}ll, Fabian and Braunstein, Bjoern and Albracht, Kirsten and Abel, Dirk}, title = {Admittance control of an industrial robot during resistance training}, series = {IFAC-PapersOnLine}, volume = {52}, journal = {IFAC-PapersOnLine}, number = {19}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2405-8963}, doi = {10.1016/j.ifacol.2019.12.102}, pages = {223 -- 228}, year = {2019}, abstract = {Neuromuscular strength training of the leg extensor muscles plays an important role in the rehabilitation and prevention of age and wealth related diseases. In this paper, we focus on the design and implementation of a Cartesian admittance control scheme for isotonic training, i.e. leg extension and flexion against a predefined weight. For preliminary testing and validation of the designed algorithm an experimental research and development platform consisting of an industrial robot and a force plate mounted at its end-effector has been used. Linear, diagonal and arbitrary two-dimensional motion trajectories with different weights for the leg extension and flexion part are applied. The proposed algorithm is easily adaptable to trajectories consisting of arbitrary six-dimensional poses and allows the implementation of individualized trajectories.}, language = {en} } @article{KeusgenJuengerKnobbeetal.2003, author = {Keusgen, M. and J{\"u}nger, M. and Knobbe, D.-T. and Kloock, Joachim P. and Sch{\"o}ning, Michael Josef}, title = {Entwicklung eines potentiometrischen Cyanid-Biosensors auf der Basis von EIS-Strukturen}, series = {Sensoren f{\"u}r zuk{\"u}nftige Hochtechnologien und Neuentwicklungen f{\"u}r die Verfahrenstechnik / 6. Dresdner Sensor-Symposium, 8. - 10. Dezember 2003, Dresden. J{\"o}rg Peter Baselt; Gerald Gerlach (Hg.)}, journal = {Sensoren f{\"u}r zuk{\"u}nftige Hochtechnologien und Neuentwicklungen f{\"u}r die Verfahrenstechnik / 6. Dresdner Sensor-Symposium, 8. - 10. Dezember 2003, Dresden. J{\"o}rg Peter Baselt; Gerald Gerlach (Hg.)}, publisher = {w.e.b.-Univ.-Verl.}, address = {Dresden}, isbn = {3-935712-92-8}, pages = {235 -- 238}, year = {2003}, language = {de} } @article{KeusgenJuengerKrestetal.2003, author = {Keusgen, M. and J{\"u}nger, M. and Krest, I. and Sch{\"o}ning, Michael Josef}, title = {Development of a biosensor specific for cysteine sulfoxides}, series = {Biosensors \& Bioelectronics. 18 (2003), H. 5-6}, journal = {Biosensors \& Bioelectronics. 18 (2003), H. 5-6}, isbn = {0956-5663}, pages = {805 -- 812}, year = {2003}, language = {en} } @article{KeusgenJuengerSchoening2002, author = {Keusgen, M. and J{\"u}nger, M. and Sch{\"o}ning, Michael Josef}, title = {Biosensoric detection of the cysteine sulphoxide alliin}, series = {Book of abstracts / ed. by J. Saneistr.}, journal = {Book of abstracts / ed. by J. Saneistr.}, publisher = {Czech Technical University, Faculty of Electrical Engineering, Department of Measurement}, address = {Prague}, isbn = {80-01-02576-4}, pages = {1175 -- 1178}, year = {2002}, language = {en} } @article{KeusgenKloockKnobbeetal.2004, author = {Keusgen, M. and Kloock, Joachim P. and Knobbe, D.-T. and J{\"u}nger, M. and Krest, I. and Goldbach, M. and Klein, W. and Sch{\"o}ning, Michael Josef}, title = {Direct determination of cyanides by potentiometric biosensors}, series = {Sensors and Actuators B. 103 (2004), H. 1-2}, journal = {Sensors and Actuators B. 103 (2004), H. 1-2}, isbn = {0925-4005}, pages = {380 -- 385}, year = {2004}, language = {en} } @article{KeusgenSchoening2004, author = {Keusgen, M. and Sch{\"o}ning, Michael Josef}, title = {Strategies for biosensoric detection of potential drugs in nature}, series = {Biomedizinische Technik. 49 (2004), H. 2}, journal = {Biomedizinische Technik. 49 (2004), H. 2}, isbn = {0932-4666}, pages = {1004 -- 1005}, year = {2004}, language = {en} } @article{KeusgenJuengerKrestetal.2003, author = {Keusgen, Michael and J{\"u}nger, Martina and Krest, Ingo and Sch{\"o}ning, Michael Josef}, title = {Biosensoric detection of the cysteine sulphoxide alliin}, series = {Sensors and Actuators B. 95 (2003), H. 1-3}, journal = {Sensors and Actuators B. 95 (2003), H. 1-3}, isbn = {0925-4005}, pages = {297 -- 302}, year = {2003}, language = {en} } @article{KeutmannStaatLaack2018, author = {Keutmann, Sabine and Staat, Manfred and Laack, Walter van}, title = {Untersuchung der thermischen Auswirkung von therapeutischem Ultraschall}, volume = {7}, number = {10}, publisher = {Deutscher {\"A}rzte-Verl.}, address = {K{\"o}ln}, issn = {2193-5793}, pages = {518 -- 522}, year = {2018}, abstract = {Zusammenfassung: In der Orthop{\"a}die z{\"a}hlt der therapeutische Ultraschall als Mittel zur Pr{\"a}vention und Therapiebegleitung. Er hat mechanische, thermische und physiko-chemische Auswirkungen auf den menschlichen K{\"o}rper. Um mehr Erkenntnisse {\"u}ber die thermischen Auswirkungen zu erlangen, wurden Versuche an einem Hydrogel-Phantom und an Probanden durchgef{\"u}hrt. Dabei entstand eine signifikante Erw{\"a}rmung des Gewebes, welche beim Probandenversuch an der Oberfl{\"a}che und beim Hydrogelversuch in der Tiefe gemessen wurde. Summary: In orthopaedics, therapeutic ultrasound is a tool of prevention and therapy support. It has mechanical, thermal and physico-chemical effects on the human body. Tests with a hydrogel phantom and with human probands have been performed in order to obtain more knowledge about their thermal effects. Both tests measured temperature increases in cell tissue, on the surface with the human proband test and in depth with the hydrogel phantom test.}, language = {de} } @article{KhaydukovaZadorozhnayaKirsanovetal.2014, author = {Khaydukova, M. M. and Zadorozhnaya, O. A. and Kirsanov, D. O. and Iken, Heiko and Rolka, David and Sch{\"o}ning, Michael Josef and Babain, V. A. and Vlasov, Yu. G. and Legin, A. V.}, title = {Multivariate processing of atomic-force microscopy images for detection of the response of plasticized polymeric membranes}, series = {Russian journal of applied chemistry}, volume = {87}, journal = {Russian journal of applied chemistry}, number = {3}, publisher = {Springer}, address = {Dordrecht}, issn = {1608-3296 (E-Journal); 1070-4272 (Print)}, doi = {10.1134/S1070427214030112}, pages = {307 -- 314}, year = {2014}, abstract = {The possibility of using the atomic-force microscopy as a method for detection of the analytical signal from plasticized polymeric sensor membranes was analyzed. The surfaces of cadmium-selective membranes based on two polymeric matrices were examined. The digital images were processed with multivariate image analysis techniques. A correlation was found between the surface profile of an ion-selective membrane and the concentration of the ion in solution.}, language = {en} } @article{KhodaverdiChatziioannouWeberetal.2005, author = {Khodaverdi, M. and Chatziioannou, A. F. and Weber, S. and Ziemons, Karl and Halling, H. and Pietrzyk, U.}, title = {Investigation of different MicroCT scanner configurations by GEANT4 simulations}, series = {IEEE Transactions on Nuclear Science}, volume = {52}, journal = {IEEE Transactions on Nuclear Science}, number = {1}, isbn = {0018-9499}, pages = {188 -- 192}, year = {2005}, abstract = {This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.}, language = {en} } @article{KhodaverdiChaziioannouWeberetal.2004, author = {Khodaverdi, M. and Chaziioannou, A. F. and Weber, S. and Ziemons, Karl and Halling, H. and Pietrzyk, U.}, title = {Investigation of different microCT scanner configurations by GEANT4 simulations}, series = {2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4}, journal = {2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4}, issn = {1082-3654}, pages = {2989 -- 2993}, year = {2004}, abstract = {This study has been performed to design the combination of the new ClearPET TM (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal Positron Emission Tomography (PET) system, with a microComputed Tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.}, language = {en} } @article{KhodaverdiPaulySchroderetal.2002, author = {Khodaverdi, M. and Pauly, F. and Schroder, G. and Ziemons, Karl and Sievering, R. and Halling, H.}, title = {Preliminary studies of a micro-CT for a combined small animal PET/CT scanner}, series = {2001 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, journal = {2001 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, issn = {1082-3654}, pages = {1605 -- 1606}, year = {2002}, abstract = {We are developing an X-ray computed tomography (CT) system which will be combined with a high resolution animal PET system. This permits acquisition of both molecular and anatomical images in a single machine. In particular the CT will also be utilized for the quantification of the animal PET data by providing accurate data for attenuation correction. A first prototype has been built using a commercially available plane silicon diode detector. A cone-beam reconstruction provides the images using the Feldkamp algorithm. First measurements with this system have been performed on a mouse. It could be shown that the CT setup fulfils all demands for a high quality image of the skeleton of the mouse. It is also suited for soft tissue measurements. To improve contrast and resolution and to acquire the X-ray energy further development of the system, especially the use of semiconductor detectors and iterative reconstruction algorithms are planned.}, language = {en} } @article{KhodaverdiWeberStreunetal.2006, author = {Khodaverdi, M. and Weber, S. and Streun, M. and Parl, C. and Ziemons, Karl}, title = {High resolution imaging with ClearPET™ Neuro - first animal images}, series = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, journal = {2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3}, isbn = {1082-3654}, pages = {1641 -- 1644}, year = {2006}, abstract = {The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance.}, language = {en} } @inproceedings{KirchhofKraft2004, author = {Kirchhof, M. and Kraft, Bodo}, title = {UML-based modeling of architectural knowledge and design}, year = {2004}, abstract = {IASSE-2004 - 13th International Conference on Intelligent and Adaptive Systems and Software Engineering eds. W. Dosch, N. Debnath, pp. 245-250, ISCA, Cary, NC, 1-3 July 2004, Nice, France We introduce a UML-based model for conceptual design support in civil engineering. Therefore, we identify required extensions to standard UML. Class diagrams are used for elaborating building typespecific knowledge: Object diagrams, implicitly contained in the architect's sketch, are validated against the defined knowledge. To enable the use of industrial, domain-specific tools, we provide an integrated conceptual design extension. The developed tool support is based on graph rewriting. With our approach architects are enabled to deal with semantic objects during early design phase, assisted by incremental consistency checks.}, subject = {UML}, language = {en} } @article{KirchhofKraft2012, author = {Kirchhof, Michael and Kraft, Bodo}, title = {Hybrides Vorgehensmodell : Agile und klassische Methoden im Projekt passend kombinieren}, series = {ProjektMagazin}, journal = {ProjektMagazin}, number = {11}, publisher = {Berleb Media}, address = {Taufkirchen}, pages = {11 S.}, year = {2012}, abstract = {Agil ist im Trend und immer mehr Unternehmen, die ihre Projekte bisher nach klassischen Prinzipien durchf{\"u}hrten, denken {\"u}ber den Einsatz agiler Methoden nach. Doch selbst wenn die Organisation bereits beide Philosophien unterst{\"u}tzt, gilt f{\"u}r ein Projekt meist die klare Vorgabe: agil oder klassisch. Es gibt aber noch einen anderen Ansatz, mit diesen "unterschiedlichen Welten" umzugehen: Und zwar die beiden Philosophien innerhalb eines Projekts zu kombinieren. Wie dies in der Praxis aussehen und gelingen kann, zeigen Dr. Michael Kirchhof und Prof. Dr. Bodo Kraft in diesem Beitrag.}, language = {de} } @inproceedings{KirchhofKraft2011, author = {Kirchhof, Michael and Kraft, Bodo}, title = {Dogmatisches „Entweder agil oder klassisch" im Projektmanagement hat ausgedient - die richtige Mischung macht's}, series = {Projekt-Sternstunden : strahlende Erfolge durch Kompetenz}, booktitle = {Projekt-Sternstunden : strahlende Erfolge durch Kompetenz}, publisher = {GPM}, address = {N{\"u}rnberg}, isbn = {978-3-924841-60-7}, pages = {414 -- 425}, year = {2011}, language = {de} } @inproceedings{KirchnerHenkelNaetheretal.2008, author = {Kirchner, Patrick and Henkel, H. and N{\"a}ther, Niko and Spelthahn, H. and Schneider, A. and Berger, J. and Kolstad, J. and Friedrich, P. and Sch{\"o}ning, Michael Josef}, title = {RFID-basiertes Sensorsystem zur Realisierung intelligenter Verpackungen f{\"u}r die Nahrungsmittelindustrie}, series = {KMU - innovativ: IKT 2008. CD-ROM : BMBF-Statustagung KMU - innovativ: IKT, Darmstadt, 17. - 18. Nov. 2008}, booktitle = {KMU - innovativ: IKT 2008. CD-ROM : BMBF-Statustagung KMU - innovativ: IKT, Darmstadt, 17. - 18. Nov. 2008}, number = {CD-ROM-Ausg.}, publisher = {BMBF}, address = {Berlin}, pages = {9 S.}, year = {2008}, language = {de} } @article{KirchnerLiSpelthahnetal.2009, author = {Kirchner, Patrick and Li, B. and Spelthahn, H. and Henkel, H. and Friedrich, P. and Kolstad, J. and Keusgen, M. and Sch{\"o}ning, Michael Josef}, title = {Thin-film calorimetric H2O2 gas sensor for the validation of germicidal effectivity in aseptic filling processes}, series = {Procedia Chemistry. 1 (2009), H. 1}, journal = {Procedia Chemistry. 1 (2009), H. 1}, isbn = {1876-6196}, pages = {983 -- 986}, year = {2009}, language = {en} } @article{KirchnerLiSpelthahnetal.2009, author = {Kirchner, Patrick and Li, B. and Spelthahn, H. and Henkel, H. and Schneider, A. and Kolstad, J. and Friedrich, P. and Sch{\"o}ning, Michael Josef}, title = {Realisierung eines miniaturisierten Gassensors in Chiptechnologie basierend auf einer D{\"u}nnschicht-Thermos{\"a}ule zur H2O2-Detektion in aseptischen Abf{\"u}llanlagen}, series = {9. Dresdner Sensor-Symposium : Dresden, 07.-09. Dezember 2009 / Gerlach, Gerald ; Hauptmann, Peter [Hrsg.]}, journal = {9. Dresdner Sensor-Symposium : Dresden, 07.-09. Dezember 2009 / Gerlach, Gerald ; Hauptmann, Peter [Hrsg.]}, publisher = {TUDpress}, address = {Dresden}, isbn = {978-3-941298-44-6}, pages = {293 -- 296}, year = {2009}, language = {de} } @article{KirchnerLiSpelthahnetal.2011, author = {Kirchner, Patrick and Li, Bin and Spelthahn, Heiko and Henkel, Hartmut and Schneider, Andreas and Friedrich, Peter and Kolstad, Jens and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Thin-film calorimetric H2O2 gas sensor for the validation of germicidal effectivity in aseptic filling processes}, series = {Sensors and Actuators B: Chemical. 154 (2011), H. 2}, journal = {Sensors and Actuators B: Chemical. 154 (2011), H. 2}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1873-3077}, pages = {257 -- 263}, year = {2011}, language = {en} } @article{KirchnerOberlaenderFriedrichetal.2012, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Friedrich, Peter and Berger, J{\"o}rg and Rysstad, Gunnar and Sch{\"o}ning, Michael Josef and Keusgen, Michael}, title = {Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2011.01.032}, pages = {60 -- 66}, year = {2012}, abstract = {A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(\%, v/v) in a H2O2 concentration range of 0\%, v/v to 8\%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes.}, language = {en} } @article{KirchnerOberlaenderFriedrichetal.2011, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Friedrich, Peter and Berger, J{\"o}rg and Suso, Henri-Pierre and Kupyna, Andriy and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Optimisation and fabrication of a calorimetric gas sensor built up on a polyimide substrate for H2O2 monitoring}, series = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, journal = {Physica status solidi (a) : applications and material science. 208 (2011), H. 6}, publisher = {Wiley}, address = {Weinheim}, isbn = {1862-6319}, pages = {1235 -- 1240}, year = {2011}, language = {en} } @article{KirchnerOberlaenderFriedrichetal.2010, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Friedrich, Peter and Rysstad, G. and Berger, J. and Keusgen, M. and Sch{\"o}ning, Michael Josef}, title = {Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry}, series = {Procedia Engineering. 5 (2010)}, journal = {Procedia Engineering. 5 (2010)}, isbn = {1877-7058}, pages = {264 -- 267}, year = {2010}, language = {en} } @article{KirchnerOberlaenderSucoetal.2013, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Suco, Henri-Pierre and Rysstad, Gunnar and Sch{\"o}ning, Michael Josef}, title = {Monitoring the microbicidal effectiveness of gaseous hydrogen peroxide in sterilisation processes by means of a calorimetric gas sensor}, series = {Food control}, volume = {31}, journal = {Food control}, number = {2}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0956-7135}, doi = {10.1016/j.foodcont.2012.11.048}, pages = {530 -- 538}, year = {2013}, abstract = {In the present work, a novel method for monitoring sterilisation processes with gaseous H2O2 in combination with heat activation by means of a specially designed calorimetric gas sensor was evaluated. Therefore, the sterilisation process was extensively studied by using test specimens inoculated with Bacillus atrophaeus spores in order to identify the most influencing process factors on its microbicidal effectiveness. Besides the contact time of the test specimens with gaseous H2O2 varied between 0.2 and 0.5 s, the present H2O2 concentration in a range from 0 to 8\% v/v (volume percent) had a strong influence on the microbicidal effectiveness, whereas the change of the vaporiser temperature, gas flow and humidity were almost negligible. Furthermore, a calorimetric H2O2 gas sensor was characterised in the sterilisation process with gaseous H2O2 in a wide range of parameter settings, wherein the measurement signal has shown a linear response against the H2O2 concentration with a sensitivity of 4.75 °C/(\% v/v). In a final step, a correlation model by matching the measurement signal of the gas sensor with the microbial inactivation kinetics was established that demonstrates its suitability as an efficient method for validating the microbicidal effectiveness of sterilisation processes with gaseous H2O2.}, language = {en} } @article{KirchnerOberlaenderSusoetal.2013, author = {Kirchner, Patrick and Oberl{\"a}nder, Jan and Suso, Henri-Pierre and Rysstad, Gunnar and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes}, series = {Physica status solidi (a)}, volume = {210}, journal = {Physica status solidi (a)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201200920}, pages = {877 -- 883}, year = {2013}, abstract = {A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests.}, language = {en} } @article{KirchnerReisertPuetzetal.2012, author = {Kirchner, Patrick and Reisert, Steffen and P{\"u}tz, Patrick and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Characterisation of polymeric materials as passivation layer for calorimetric H2O2 gas sensors}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100773}, pages = {859 -- 863}, year = {2012}, abstract = {Calorimetric gas sensors for monitoring the H₂O₂ concentration at elevated temperatures in industrial sterilisation processes have been presented in previous works. These sensors are built up in form of a differential set-up of a catalytically active and passive temperature-sensitive structure. Although, various types of catalytically active dispersions have been studied, the passivation layer has to be established and therefore, chemically as well as physically characterised. In the present work, fluorinated ethylene propylene (FEP), perfluoralkoxy (PFA) and epoxy-based SU-8 photoresist as temperature-stable polymeric materials have been investigated for sensor passivation in terms of their chemical inertness against H₂O₂, their hygroscopic properties as well as their morphology. The polymeric materials were deposited via spin-coating on the temperature-sensitive structure, wherein spin-coated FEP and PFA show slight agglomerates. However, they possess a low absorption of humidity due to their hydrophobic surface, whereas the SU-8 layer has a closed surface but shows a slightly higher absorption of water. All of them were inert against gaseous H₂O₂ during the characterisation in H₂O₂ atmosphere that demonstrates their suitability as passivation layer for calorimetric H₂O₂ gas sensors.}, language = {en} } @article{KirchnerSpelthahnSchoeningetal.2010, author = {Kirchner, Patrick and Spelthahn, H. and Sch{\"o}ning, Michael Josef and Henkel, H. and Schneider, A. and Friedrich, P. and Kolstad, J. and Berger, J.}, title = {Realisierung eines Polyimid-basierten kalorimetrischen Gassensors zur Inline-{\"U}berwachung der H2O2-Konzentration in aseptischen Abf{\"u}llanlagen}, series = {Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vortr{\"a}ge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in N{\"u}rnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA)}, journal = {Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vortr{\"a}ge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in N{\"u}rnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA)}, publisher = {VDE Verlag}, address = {Berlin}, isbn = {978-3-8007-3260-9}, pages = {607 -- 612}, year = {2010}, language = {de} } @article{KleefeldReissel2011, author = {Kleefeld, A. and Reißel, Martin}, title = {The Levenberg-Marquardt method applied to a parameter estimation problem arising from electrical resistivity tomography}, series = {Applied Mathematics and Computation}, volume = {217}, journal = {Applied Mathematics and Computation}, number = {9}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {0096-3003}, pages = {4490 -- 4501}, year = {2011}, language = {en} } @article{KleinesErkiZiemonsetal.1997, author = {Kleines, H. and Erki, I. and Ziemons, Karl and Zwoll, K.}, title = {ATM- und Multimedia Pilotsystem im Rahmen des Projektes M-FIBRe Aufbau und Erfahrungen}, series = {Bildverarbeitung f{\"u}r die Medizin : Algorithmen - Systeme - Anwendungen}, journal = {Bildverarbeitung f{\"u}r die Medizin : Algorithmen - Systeme - Anwendungen}, editor = {Lehmann, Thomas}, publisher = {Verl. der. Augustinus-Buchh.}, address = {Aachen}, isbn = {3-86073-519-5}, pages = {241 -- 248}, year = {1997}, language = {de} } @article{KloockMorenoBratovetal.2006, author = {Kloock, Joachim P. and Moreno, Lia and Bratov, A. and Huachupoma, S. and Xu, J. and Wagner, Torsten and Yoshinobu, T. and Ermolenko, Y. and Vlasov, Y. G. and Sch{\"o}ning, Michael Josef}, title = {PLD-prepared cadmium sensors based on chalcogenide glasses —ISFET, LAPS and \&\#956;ISE semiconductor structures}, series = {Sensors and Actuators B: Chemical. 118 (2006), H. 1-2}, journal = {Sensors and Actuators B: Chemical. 118 (2006), H. 1-2}, isbn = {0925-4005}, pages = {149 -- 155}, year = {2006}, language = {en} } @inproceedings{KloockMorenoHuachupomaetal.2005, author = {Kloock, Joachim P. and Moreno, Lia and Huachupoma, S. and Xu, J. and Wagner, Torsten and Bratov, A. and Doll, T. and Vlasov, Y. and Sch{\"o}ning, Michael Josef}, title = {Halbleiterbasierte Schwermetallsensorik auf der Basis von Chalkogenidgl{\"a}sern f{\"u}r zuk{\"u}nftige „Lab on Chip"-Anwendungen}, series = {7. Dresdner Sensor-Symposium - Neue Herausforderungen und Anwendungen in der Sensortechnik}, booktitle = {7. Dresdner Sensor-Symposium - Neue Herausforderungen und Anwendungen in der Sensortechnik}, editor = {Gerlach, Gerald}, publisher = {TUDpress, Verl. der Wissenschaften}, address = {Dresden}, isbn = {3-938863-29-3}, pages = {221 -- 224}, year = {2005}, language = {de} } @article{KloockMourzinaSchubertetal.2004, author = {Kloock, Joachim P. and Mourzina, Y. and Schubert, J. and Ermelenko, Y. and Sch{\"o}ning, Michael Josef}, title = {Pulsed laser deposition: A tool for fabricating thin-film microsensors}, series = {Biomedizinische Technik. 49 (2004), H. 2}, journal = {Biomedizinische Technik. 49 (2004), H. 2}, isbn = {0932-4666}, pages = {1032 -- 1033}, year = {2004}, language = {en} } @article{KloockMourzinaErmolenkoetal.2004, author = {Kloock, Joachim P. and Mourzina, Y.G. and Ermolenko, Y. and Doll, T. and Schubert, J. and Sch{\"o}ning, Michael Josef}, title = {Inorganic thin-film sensor membranes with PLD-prepared chalcogenide glasses: Challenges and implementation}, series = {Sensors. 4 (2004), H. 10}, journal = {Sensors. 4 (2004), H. 10}, isbn = {1424-8220}, pages = {156 -- 162}, year = {2004}, language = {en} } @article{KloockMourzinaYoshinobuetal.2002, author = {Kloock, Joachim P. and Mourzina, Y.G. and Yoshinobu, T. and Schubert, J. and Sch{\"o}ning, Michael Josef}, title = {Chalkogenidglassensoren f{\"u}r die Schwermetallanalytik}, series = {Sensoren und Mess-Systeme : Vortr{\"a}ge der 11. ITG/GMA-Fachtagung vom 11. bis 12. M{\"a}rz 2002 in Ludwigsburg / Veranst.: Informationstechnische Gesellschaft im VDE (ITG) ... Wiss. Tagungsleitung: C. D. Kohl ....}, journal = {Sensoren und Mess-Systeme : Vortr{\"a}ge der 11. ITG/GMA-Fachtagung vom 11. bis 12. M{\"a}rz 2002 in Ludwigsburg / Veranst.: Informationstechnische Gesellschaft im VDE (ITG) ... Wiss. Tagungsleitung: C. D. Kohl ....}, publisher = {VDE-Verl.}, address = {Berlin [u.a.]}, isbn = {3-8007-2675-0}, pages = {395 -- 398}, year = {2002}, language = {de} } @article{KloockPoghossianSchumacheretal.2006, author = {Kloock, Joachim P. and Poghossian, Arshak and Schumacher, K. and Rosenkranz, C. and Schultze, J. W. and M{\"u}ller-Veggian, Mattea and Sch{\"o}ning, Michael Josef}, title = {Funktionspr{\"u}fung und Charakterisierung von ionensensitiven Feldeffekttransistoren (ISFETs) auf Waferebene mittels Mikrotropfenzelle f{\"u}r den zuk{\"u}nftigen Einsatz in der Sensorproduktion}, series = {Sensoren und Messsysteme 2006 : Vortr{\"a}ge der 13. ITG/GMA-Fachtagung vom 13. bis 14. M{\"a}rz 2006 in Freiburg/Breisgau / Veranst.: Informationstechnische Gesellschaft im VDE (ITG) ; VDE/VDI-Gesellschaft Mess- und Automatisierungstechnik (GMA). Wiss. Tagungsleitung: L. M. Reindl}, journal = {Sensoren und Messsysteme 2006 : Vortr{\"a}ge der 13. ITG/GMA-Fachtagung vom 13. bis 14. M{\"a}rz 2006 in Freiburg/Breisgau / Veranst.: Informationstechnische Gesellschaft im VDE (ITG) ; VDE/VDI-Gesellschaft Mess- und Automatisierungstechnik (GMA). Wiss. Tagungsleitung: L. M. Reindl}, publisher = {VDE-Verl.}, address = {Berlin}, isbn = {3-8007-2939-3}, pages = {257 -- 260}, year = {2006}, language = {de} } @inproceedings{KloockSchubertErmelenkoetal.2006, author = {Kloock, Joachim P. and Schubert, J. and Ermelenko, Y. and Vlasov, Y. G. and Bratov, A. and Sch{\"o}ning, Michael Josef}, title = {Thin-film sensors with chalcogenide glass materials - a general survey}, series = {Biochemical sensing utilisation of micro- and nanotechnologies : Warsaw, [23rd - 26th] November 2005 / ed. by M. Mascini ...}, booktitle = {Biochemical sensing utilisation of micro- and nanotechnologies : Warsaw, [23rd - 26th] November 2005 / ed. by M. Mascini ...}, address = {Warsaw}, pages = {92 -- 97}, year = {2006}, language = {en} } @inproceedings{KloockSchoening2007, author = {Kloock, Joachim P. and Sch{\"o}ning, Michael Josef}, title = {Heavy metal detection with semiconductor devices based on PLD-prepared chalcogenide glass thin films}, series = {Armenian Journal of Physics}, booktitle = {Armenian Journal of Physics}, issn = {1829-1171}, pages = {95 -- 98}, year = {2007}, language = {en} }