@article{MiyamotoSekiSutoetal.2018, author = {Miyamoto, Koichiro and Seki, Kosuke and Suto, Takeyuki and Werner, Frederik and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Improved spatial resolution of the chemical imaging sensor with a hybrid illumination that suppresses lateral diffusion of photocarriers}, series = {Sensor and Actuators B: Chemical}, volume = {273}, journal = {Sensor and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2018.07.016}, pages = {1328 -- 1333}, year = {2018}, abstract = {The chemical imaging sensor is a semiconductor-based chemical sensor capable of visualizing pH and ion distributions. The spatial resolution depends on the lateral diffusion of photocarriers generated by illumination of the semiconductor substrate. In this study, two types of optical setups, one based on a bundle of optical fibers and the other based on a binocular tube head, were developed to project a hybrid illumination of a modulated light beam and a ring-shaped constant illumination onto the sensor plate. An improved spatial resolution was realized by the ring-shaped constant illumination, which suppressed lateral diffusion of photocarriers by enhanced recombination due to the increased carrier concentration.}, language = {en} } @article{DelleHuckBaeckeretal.2015, author = {Delle, Lotta E. and Huck, Christina and B{\"a}cker, Matthias and M{\"u}ller, Frank and Grandthyll, Samuel and Jacobs, Karin and Lilischkis, Rainer and Vu, Xuan T. and Sch{\"o}ning, Michael Josef and Wagner, Patrick and Thoelen, Roland and Weil, Maryam and Ingebrandt, Sven}, title = {Impedimetric immunosensor for the detection of histamine based on reduced graphene oxide}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431863}, pages = {1327 -- 1334}, year = {2015}, language = {en} } @article{RiedelKartchemnikSchoeningetal.2014, author = {Riedel, Marc and Kartchemnik, Julia and Sch{\"o}ning, Michael Josef and Lisdat, Fred}, title = {Impedimetric DNA detection - steps forward to sensorial application}, series = {Analytical chemistry}, volume = {86 (2014)}, journal = {Analytical chemistry}, number = {15}, publisher = {ACS Publications}, address = {Columbus}, issn = {1520-6882 (E-Journal); 0003-2700 (Print); 0096-4484 (Print)}, doi = {10.1021/ac501800q}, pages = {7867 -- 7874}, year = {2014}, abstract = {This study describes a label-free impedimetric sensor based on short ssDNA recognition elements for the detection of hybridization events. We concentrate on the elucidation of the influence of target length and recognition sequence position on the sensorial performance. The impedimetric measurements are performed in the presence of the redox system ferri-/ferrocyanide and show an increase in charge transfer resistance upon hybridization of ssDNA to the sensor surface. Investigations on the impedimetric signal stability demonstrate a clear influence of the buffers used during the sensor preparation and the choice of the passivating mercaptoalcanol compound. A stable sensor system has been developed, enabling a reproducible detection of 25mer target DNA in the low nanomolar range. After hybridization, a sensor regeneration can be reached with deionized water by adjustment of effective convection conditions, ensuring a sensor reusability. By investigations of longer targets with overhangs exposed to the solution, we can demonstrate applicability of the impedimetric detection for longer ssDNA. However, a decreasing charge transfer resistance change (ΔRct) is found by extending the overhang. As a strategy to increase the impedance change for longer target strands, the position of the recognition sequence can be designed in a way that a small overhang is exposed to the electrode surface. This is found to result in an increase in the relative Rct change. These results suggest that DNA and consequently negative charge near the electrode possess a larger impact on the impedimetric signal than DNA further away.}, language = {en} } @inproceedings{OberlaenderArreolaHansenetal.2017, author = {Oberl{\"a}nder, Jan and Arreola, Julio and Hansen, Christina and Greeff, Anton and Mayer, Marlena and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Impedimetric Biosensor to Enable Fast Evaluation of Gaseous Sterilization Processes}, series = {MDPI Proceedings}, volume = {1}, booktitle = {MDPI Proceedings}, number = {4}, doi = {10.3390/proceedings1040435}, pages = {4 Seiten}, year = {2017}, language = {en} } @article{SchusserLeinhosBaeckeretal.2013, author = {Schusser, Sebastian and Leinhos, Marcel and B{\"a}cker, Matthias and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers}, series = {Physica Status Solidi (A)}, volume = {210}, journal = {Physica Status Solidi (A)}, number = {5}, publisher = {Wiley}, address = {Weinheim}, issn = {1521-396X ; 0031-8965}, doi = {10.1002/pssa.201200941}, pages = {905 -- 910}, year = {2013}, abstract = {Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution.}, language = {en} } @article{PoghossianMaiMourzinaetal.2004, author = {Poghossian, Arshak and Mai, D.-T. and Mourzina, Y. and Sch{\"o}ning, Michael Josef}, title = {Impedance effect of an ion-sensitive membrane: characterisation of an EMIS sensor by impedance spectroscopy, capacitance-voltage and constant-capacitance method}, series = {Sensors and Actuators B. 103 (2004), H. 1-2}, journal = {Sensors and Actuators B. 103 (2004), H. 1-2}, isbn = {0925-4005}, pages = {423 -- 428}, year = {2004}, language = {en} } @article{MourzinaYoshinobuErmolenkoetal.2004, author = {Mourzina, Ioulia G. and Yoshinobu, Tatsuo and Ermolenko, Yuri E. and Vlasov, Yuri G. and Sch{\"o}ning, Michael Josef and Iwasaki, H.}, title = {Immobilization of urease and cholinesterase on the surface of semiconductor transducer for the development of lightaddressable potentiometric sensors}, series = {Microchimica Acta. 144 (2004), H. 1-3}, journal = {Microchimica Acta. 144 (2004), H. 1-3}, isbn = {0026-3672}, pages = {41 -- 50}, year = {2004}, language = {en} } @article{MourzinaYoshinobuErmolenkoetal.2004, author = {Mourzina, I.G. and Yoshinobu, T. and Ermolenko, Y.E. and Vlasov, Y. G. and Sch{\"o}ning, Michael Josef and Iwasaki, H.}, title = {Immobilization of urease and cholinesterase on the surface of semiconductor transducer for the development of light-addressable potentiometric sensors}, series = {Technical digest of the 10th International Meeting on Chemical Sensors, July 11 - 14, 2004, Tsukuba, Japan / Japan Association of Chemical Sensors}, journal = {Technical digest of the 10th International Meeting on Chemical Sensors, July 11 - 14, 2004, Tsukuba, Japan / Japan Association of Chemical Sensors}, publisher = {Japan Association of Chemical Sensors}, address = {Fukuoka}, pages = {788 -- 789}, year = {2004}, language = {en} } @article{MiyamotoSugawaraKanohetal.2010, author = {Miyamoto, Ko-ichiro and Sugawara, Yuri and Kanoh, Shin´ichiro and Yoshinobu, Tatsuo and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Image correction method for the chemical imaging sensor}, series = {Sensors and Actuators B: Chemical. 144 (2010), H. 2}, journal = {Sensors and Actuators B: Chemical. 144 (2010), H. 2}, pages = {344 -- 348}, year = {2010}, language = {en} } @article{BreuerRaueStrobeletal.2016, author = {Breuer, Lars and Raue, Markus and Strobel, M. and Mang, Thomas and Sch{\"o}ning, Michael Josef and Thoelen, R. and Wagner, Torsten}, title = {Hydrogels with incorporated graphene oxide as light-addressable actuator materials for cell culture environments in lab-on-chip systems}, series = {Physica status solidi (a)}, volume = {213}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6300}, doi = {10.1002/pssa.201533056}, pages = {1520 -- 1525}, year = {2016}, abstract = {Abstractauthoren Graphene oxide (GO) nanoparticles were incorporated in temperature-sensitive Poly(N-isopropylacrylamide) (PNIPAAm) hydrogels. The nanoparticles increase the light absorption and convert light energy into heat efficiently. Thus, the hydrogels with GO can be stimulated spatially resolved by illumination as it was demonstrated by IR thermography. The temporal progression of the temperature maximum was detected for different concentrations of GO within the polymer network. Furthermore, the compatibility of PNIPAAm hydrogels with GO and cell cultures was investigated. For this purpose, culture medium was incubated with hydrogels containing GO and the viability and morphology of chinese hamster ovary (CHO) cells was examined after several days of culturing in presence of this medium.}, language = {en} } @article{MoraisSilvaDantasetal.2019, author = {Morais, Paulo V. and Silva, Anielle C. A. and Dantas, Noelio O. and Sch{\"o}ning, Michael Josef and Siqueira, Jos{\´e} R., Jr.}, title = {Hybrid Layer-by-Layer Film of Polyelectrolytes-Embedded Catalytic CoFe2O4 Nanocrystals as Sensing Units in Capacitive Electrolyte-Insulator-Semiconductor Devices}, series = {physica status solidi a : applications and materials sciences}, volume = {216}, journal = {physica status solidi a : applications and materials sciences}, number = {1900044}, publisher = {Wiley}, address = {Weinheim}, doi = {10.1002/pssa.201900044}, pages = {1 -- 9}, year = {2019}, language = {en} } @article{ItabashiKosakaMiyamotoetal.2013, author = {Itabashi, Akinori and Kosaka, Naoki and Miyamoto, Ko-ichiro and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {High-speed chemical imaging system based on front-side-illuminated LAPS}, series = {Sensors and actuators B: Chemical}, volume = {182}, journal = {Sensors and actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077}, doi = {10.1016/j.snb.2013.03.016}, pages = {315 -- 321}, year = {2013}, abstract = {The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of specific ions on the sensing surface. The conventional chemical imaging system based on the light-addressable potentiometric sensor (LAPS), however, required a long time to obtain a chemical image, due to the slow mechanical scan of a single light beam. For high-speed imaging, a plurality of light beams modulated at different frequencies can be employed to measure the ion concentrations simultaneously at different locations on the sensor plate by frequency division multiplex (FDM). However, the conventional measurement geometry of back-side illumination limited the bandwidth of the modulation frequency required for FDM measurement, because of the low-pass filtering characteristics of carrier diffusion in the Si substrate. In this study, a high-speed chemical imaging system based on front-side-illuminated LAPS was developed, which achieved high-speed spatiotemporal recording of pH change at a rate of 70 frames per second.}, language = {en} } @article{MiyamotoItabashiWagneretal.2014, author = {Miyamoto, Ko-ichiro and Itabashi, Akinori and Wagner, Torsten and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {High-speed chemical imaging inside a microfluidic channel}, series = {Sensors and actuators. B: Chemical}, volume = {194}, journal = {Sensors and actuators. B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-3077 (E-Journal); 0925-4005 (Print)}, doi = {10.1016/j.snb.2013.12.090}, pages = {521 -- 527}, year = {2014}, abstract = {In this study, a high-speed chemical imaging system was developed for visualization of the interior of a microfluidic channel. A microfluidic channel was constructed on the sensor surface of the light-addressable potentiometric sensor (LAPS), on which the ion concentrations could be measured in parallel at up to 64 points illuminated by optical fibers. The temporal change of pH distribution inside the microfluidic channel was recorded at a maximum rate of 100 frames per second (fps). The high frame rate allowed visualization of moving interfaces and plugs in the channel even at a flow velocity of 111 mm/s, which suggests the feasibility of plug-based microfluidic devices for flow-injection analysis (FIA).}, language = {en} } @article{WernerWagnerMiyamotoetal.2012, author = {Werner, Frederik and Wagner, Torsten and Miyamoto, Ko-ichiro and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {High speed and high resolution chemical imaging based on a new type of OLED-LAPS set-up}, series = {Sensors and Actuators B: Chemical}, volume = {175}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2011.12.102}, pages = {118 -- 122}, year = {2012}, abstract = {Light-addressable potentiometric sensors (LAPS) are field-effect-based sensors. A modulated light source is used to define the particular measurement spot to perform spatially resolved measurements of chemical species and to generate chemical images. In this work, an organic-LED (OLED) display has been chosen as a light source. This allows high measurement resolution and miniaturisation of the system. A new developed driving method for the OLED display optimised for LAPS-based measurements is demonstrated. The new method enables to define modulation frequencies between 1 kHz and 16 kHz and hence, reduces the measurement time of a chemical image by a factor of 40 compared to the traditional addressing of an OLED display.}, language = {en} } @article{WernerWagnerMiyamotoetal.2011, author = {Werner, Frederik and Wagner, Torsten and Miyamoto, Ko-ichiro and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {High speed and high resolution chemical imaging based on a new type of OLED-LAPS set-up}, series = {Procedia Engineering. 25 (2011)}, journal = {Procedia Engineering. 25 (2011)}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1877-7058}, pages = {346 -- 349}, year = {2011}, language = {en} } @article{MoritzYoshinobuFingeretal.2004, author = {Moritz, W. and Yoshinobu, T. and Finger, F. and Krause, S. and Martin-Fernandez, M. and Sch{\"o}ning, Michael Josef}, title = {High resolution LAPS using amorphous silicon as the semiconductor material}, series = {Sensors and Actuators B. 103 (2004), H. 1-2}, journal = {Sensors and Actuators B. 103 (2004), H. 1-2}, isbn = {0925-4005}, pages = {436 -- 444}, year = {2004}, language = {en} } @article{BresselSchultzeKhanetal.2003, author = {Bressel, A. and Schultze, J.W. and Khan, W. and Wolfaardt, G. M. and Rohns, H.-P. and Irmscher, R. and Sch{\"o}ning, Michael Josef}, title = {High resolution gravimetric, optical and electrochemical investigations of microbial biofilm formation in aqueous systems}, series = {Electrochimica Acta. 48 (2003), H. 20-22}, journal = {Electrochimica Acta. 48 (2003), H. 20-22}, isbn = {0013-4686}, pages = {3363 -- 3372}, year = {2003}, language = {en} } @article{TurekSchoeningKloocketal.2008, author = {Turek, Monika and Sch{\"o}ning, Michael Josef and Kloock, Joachim P. and Schubert, J{\"u}rgen and Zander, Willi and Kr{\"u}ger, Peter and Keusgen, Michael}, title = {Herstellung und Charakterisierung eines hybriden Sensorarrays auf Halbleiterbasis f{\"u}r die Umweltanalytik}, series = {Sensoren und Messsysteme 2008 : 14. Fachtagung Ludwigsburg, 11. und 12. M{\"a}rz 2008 / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik}, journal = {Sensoren und Messsysteme 2008 : 14. Fachtagung Ludwigsburg, 11. und 12. M{\"a}rz 2008 / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik}, publisher = {VDI-Verl.}, address = {D{\"u}sseldorf}, isbn = {978-3-18-092011-5}, pages = {803 -- 810}, year = {2008}, language = {de} } @inproceedings{KloockSchoening2007, author = {Kloock, Joachim P. and Sch{\"o}ning, Michael Josef}, title = {Heavy metal detection with semiconductor devices based on PLD-prepared chalcogenide glass thin films}, series = {Armenian Journal of Physics}, booktitle = {Armenian Journal of Physics}, issn = {1829-1171}, pages = {95 -- 98}, year = {2007}, language = {en} } @article{GrinsvenBonStrauvenetal.2012, author = {Grinsven, Bart van and Bon, Natalie vanden and Strauven, Hannelore and Grieten, Lars and Murib, Mohammed and Jim{\´e}nez Monroy, Kathia L. and Janssens, Stoffel D. and Haenen, Ken and Sch{\"o}ning, Michael Josef and Vermeeren, Veronique and Ameloot, Marcel and Michiels, Luc and Thoelen, Ronald and Ceuninck, Ward de and Wagner, Patrick}, title = {Heat-Transfer Resistance at Solid-Liquid Interfaces: A Tool for The Detection of Single Nucleotide Polymorphisms in DNA.}, series = {ACS Nano}, volume = {6}, journal = {ACS Nano}, number = {3}, publisher = {ACS Publications}, address = {Washington, DC}, issn = {1936-086X}, doi = {10.1021/nn300147e}, pages = {2712 -- 2721}, year = {2012}, abstract = {In this article, we report on the heat-transfer resistance at interfaces as a novel, denaturation-based method to detect single-nucleotide polymorphisms in DNA. We observed that a molecular brush of double-stranded DNA grafted onto synthetic diamond surfaces does not notably affect the heat-transfer resistance at the solid-to-liquid interface. In contrast to this, molecular brushes of single-stranded DNA cause, surprisingly, a substantially higher heat-transfer resistance and behave like a thermally insulating layer. This effect can be utilized to identify ds-DNA melting temperatures via the switching from low- to high heat-transfer resistance. The melting temperatures identified with this method for different DNA duplexes (29 base pairs without and with built-in mutations) correlate nicely with data calculated by modeling. The method is fast, label-free (without the need for fluorescent or radioactive markers), allows for repetitive measurements, and can also be extended toward array formats. Reference measurements by confocal fluorescence microscopy and impedance spectroscopy confirm that the switching of heat-transfer resistance upon denaturation is indeed related to the thermal on-chip denaturation of DNA.}, language = {en} } @article{MuribYeapEurlingsetal.2016, author = {Murib, M. S. and Yeap, W. S. and Eurlings, Y. and Grinsven, B. van and Boyen, H.-G. and Conings, B. and Michiels, L. and Ameloot, M. and Carleer, R. and Warmer, J. and Kaul, P. and Haenen, K. and Sch{\"o}ning, Michael Josef and Ceuninck, W. de and Wagner, P.}, title = {Heat-transfer based characterization of DNA on synthetic sapphire chips}, series = {Sensors and Actuators B: Chemical}, volume = {230}, journal = {Sensors and Actuators B: Chemical}, number = {230}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2016.02.027}, pages = {260 -- 271}, year = {2016}, abstract = {In this study, we show that synthetic sapphire (Al₂O₃), an established implant material, can also serve as a platform material for biosensors comparable to nanocrystalline diamond. Sapphire chips, beads, and powder were first modified with (3-aminopropyl) triethoxysilane (APTES), followed by succinic anhydride (SA), and finally single-stranded probe DNA was EDC coupled to the functionalized layer. The presence of the APTES-SA layer on sapphire powders was confirmed by thermogravimetric analyis and Fourier-transform infrared spectroscopy. Using planar sapphire chips as substrates and X-ray photoelectron spectroscopy (XPS) as surface-sensitive tool, the sequence of individual layers was analyzed with respect to their chemical state, enabling the quantification of areal densities of the involved molecular units. Fluorescence microscopy was used to demonstrate the hybridization of fluorescently tagged target DNA to the probe DNA, including denaturation- and re-hybridization experiments. Due to its high thermal conductivity, synthetic sapphire is especially suitable as a chip material for the heat-transfer method, which was employed to distinguish complementary- and non-complementary DNA duplexes containing single-nucleotide polymorphisms. These results indicate that it is possible to detect mutations electronically with a chemically resilient and electrically insulating chip material.}, language = {en} } @article{WagnerMolinaYoshinobuetal.2007, author = {Wagner, Torsten and Molina, Roberto and Yoshinobu, Tatsuo and Kloock, Joachim P. and Biselli, Manfred and Canzoneri, Michele and Schnitzler, Thomas and Sch{\"o}ning, Michael Josef}, title = {Handheld multi-channel LAPS device as a transducer platform for possible biological and chemical multi-sensor applications}, series = {Electrochimica Acta. 53 (2007), H. 2}, journal = {Electrochimica Acta. 53 (2007), H. 2}, isbn = {0013-4686}, pages = {305 -- 311}, year = {2007}, language = {en} } @article{WagnerMarisAckermannetal.2007, author = {Wagner, Torsten and Maris, Rob J. and Ackermann, Hans-Josef and Otto, Ralph and Beging, Stefan and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Handheld measurement device for field-effect sensor structures: Practical evaluation and limitations}, series = {Sensors and Actuators B: Chemical . 127 (2007), H. 1}, journal = {Sensors and Actuators B: Chemical . 127 (2007), H. 1}, isbn = {0925-4005}, pages = {217 -- 223}, year = {2007}, language = {en} } @inproceedings{KloockMorenoHuachupomaetal.2005, author = {Kloock, Joachim P. and Moreno, Lia and Huachupoma, S. and Xu, J. and Wagner, Torsten and Bratov, A. and Doll, T. and Vlasov, Y. and Sch{\"o}ning, Michael Josef}, title = {Halbleiterbasierte Schwermetallsensorik auf der Basis von Chalkogenidgl{\"a}sern f{\"u}r zuk{\"u}nftige „Lab on Chip"-Anwendungen}, series = {7. Dresdner Sensor-Symposium - Neue Herausforderungen und Anwendungen in der Sensortechnik}, booktitle = {7. Dresdner Sensor-Symposium - Neue Herausforderungen und Anwendungen in der Sensortechnik}, editor = {Gerlach, Gerald}, publisher = {TUDpress, Verl. der Wissenschaften}, address = {Dresden}, isbn = {3-938863-29-3}, pages = {221 -- 224}, year = {2005}, language = {de} } @article{SchoeningThustKordosetal.1998, author = {Sch{\"o}ning, Michael Josef and Thust, M. and Kordos, P. and L{\"u}th, H. and Ronkel, F. and Schultze, J. W.}, title = {Halbleiter-Schichtstrukturen mit por{\"o}sem Silizium als Chemo- und Biosensoren}, series = {ITG-Fachbericht. 148 (1998)}, journal = {ITG-Fachbericht. 148 (1998)}, isbn = {0341-0196}, pages = {33 -- 40}, year = {1998}, language = {de} } @article{SchoeningThustSteffenetal.1996, author = {Sch{\"o}ning, Michael Josef and Thust, M. and Steffen, A. and Kordos, P. and L{\"u}th, H. and Kauffmann, F. and Hoffmann, B.}, title = {Halbleiter-Biosensoren f{\"u}r den Penicillin-Nachweis in w{\"a}ßrigen L{\"o}sungen}, series = {Gesellschaft Mess- und Automatisierungstechnik: Sensoren und Messysteme : Tagung Bad Nauheim, 11. bis 13. M{\"a}rz 1996 / VDI/VDE-Gesellschaft Meß- und Automatisierungstechnik.}, journal = {Gesellschaft Mess- und Automatisierungstechnik: Sensoren und Messysteme : Tagung Bad Nauheim, 11. bis 13. M{\"a}rz 1996 / VDI/VDE-Gesellschaft Meß- und Automatisierungstechnik.}, publisher = {VDI-Verl.}, address = {D{\"u}sseldorf}, isbn = {3-18-091255-3}, pages = {143 -- 148}, year = {1996}, language = {de} } @article{NaetherBergerEmmerichetal.2008, author = {N{\"a}ther, Niko and Berger, J{\"o}rg and Emmerich, R{\"u}diger and Friedrich, P. and Henkel, H. and Sch{\"o}ning, Michael Josef}, title = {H2O2-Konzentrationsbestimmung f{\"u}r die Prozessgasanalytik mittels eines kalorimetrischen Sensoraufbaus}, series = {Sensoren und Messsysteme 2008 : 14. Fachtagung Ludwigsburg, 11. und 12. M{\"a}rz 2008 / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik}, journal = {Sensoren und Messsysteme 2008 : 14. Fachtagung Ludwigsburg, 11. und 12. M{\"a}rz 2008 / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik}, publisher = {VDI-Verl.}, address = {D{\"u}sseldorf}, isbn = {978-3-18-092011-5}, pages = {783 -- 792}, year = {2008}, language = {de} } @article{KarschuckKaulenPoghossianetal.2021, author = {Karschuck, Tobias and Kaulen, Corinna and Poghossian, Arshak and Wagner, Patrick H. and Sch{\"o}ning, Michael Josef}, title = {Gold nanoparticle-modified capacitive field-effect sensors: Studying the surface density of nanoparticles and coupling of charged polyelectrolyte macromolecules}, series = {Electrochemical Science Advances}, volume = {2}, journal = {Electrochemical Science Advances}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0938-5193}, doi = {10.1002/elsa.202100179}, pages = {10 Seiten}, year = {2021}, abstract = {The coupling of ligand-stabilized gold nanoparticles with field-effect devices offers new possibilities for label-free biosensing. In this work, we study the immobilization of aminooctanethiol-stabilized gold nanoparticles (AuAOTs) on the silicon dioxide surface of a capacitive field-effect sensor. The terminal amino group of the AuAOT is well suited for the functionalization with biomolecules. The attachment of the positively-charged AuAOTs on a capacitive field-effect sensor was detected by direct electrical readout using capacitance-voltage and constant capacitance measurements. With a higher particle density on the sensor surface, the measured signal change was correspondingly more pronounced. The results demonstrate the ability of capacitive field-effect sensors for the non-destructive quantitative validation of nanoparticle immobilization. In addition, the electrostatic binding of the polyanion polystyrene sulfonate to the AuAOT-modified sensor surface was studied as a model system for the label-free detection of charged macromolecules. Most likely, this approach can be transferred to the label-free detection of other charged molecules such as enzymes or antibodies.}, language = {en} } @article{PoghossianBaeckerMayeretal.2015, author = {Poghossian, Arshak and B{\"a}cker, Matthias and Mayer, Dirk and Sch{\"o}ning, Michael Josef}, title = {Gating capacitive field-effect sensors by the charge of nanoparticle/molecule hybrids}, series = {Nanoscale}, journal = {Nanoscale}, publisher = {Royal Society of Chemistry (RSC)}, address = {Cambridge}, issn = {2040-3372 (E-Journal); 2040-3364 (Print)}, doi = {10.1039/C4NR05987E}, pages = {1023 -- 1031}, year = {2015}, language = {en} } @article{SchoeningKirchnerNgetal.2010, author = {Sch{\"o}ning, Michael Josef and Kirchner, Patrick and Ng, Yue Ann and Spelthahn, Heiko and Schneider, Andreas and Henkel, Hartmut and Friedrich, Peter and Kolstad, Jens and Berger, J{\"o}rg and Keusgen, Michael}, title = {Gas sensor investigation based on a catalytically activated thin-film thermopile for H2O2 detection}, series = {Physica Status Solidi (A). 207 (2010), H. 4}, journal = {Physica Status Solidi (A). 207 (2010), H. 4}, isbn = {1862-6300}, pages = {787 -- 792}, year = {2010}, language = {en} } @article{BussEckenWinkelsetal.2000, author = {Buß, G. and Ecken, H. and Winkels, S. and Sch{\"o}ning, Michael Josef and L{\"u}th, H. and Schultze, J. W.}, title = {Galvanic modifications of multifunctional silicon-based microelectrode arrays}, series = {Electrochemical technology applications in electronics : proceedings of the third international symposium / [International Symposium on Electrochemical Technology Applications in Electronics, held during October 20 - 22, 1999, Honolulu, Hawaii]. Electrodeposition Division. Ed.: L. T. Romankiw}, journal = {Electrochemical technology applications in electronics : proceedings of the third international symposium / [International Symposium on Electrochemical Technology Applications in Electronics, held during October 20 - 22, 1999, Honolulu, Hawaii]. Electrodeposition Division. Ed.: L. T. Romankiw}, publisher = {Electrochemical Society}, address = {Pennington, NJ}, isbn = {1566772575}, pages = {209 -- 215}, year = {2000}, language = {en} } @article{KloockPoghossianSchumacheretal.2006, author = {Kloock, Joachim P. and Poghossian, Arshak and Schumacher, K. and Rosenkranz, C. and Schultze, J. W. and M{\"u}ller-Veggian, Mattea and Sch{\"o}ning, Michael Josef}, title = {Funktionspr{\"u}fung und Charakterisierung von ionensensitiven Feldeffekttransistoren (ISFETs) auf Waferebene mittels Mikrotropfenzelle f{\"u}r den zuk{\"u}nftigen Einsatz in der Sensorproduktion}, series = {Sensoren und Messsysteme 2006 : Vortr{\"a}ge der 13. ITG/GMA-Fachtagung vom 13. bis 14. M{\"a}rz 2006 in Freiburg/Breisgau / Veranst.: Informationstechnische Gesellschaft im VDE (ITG) ; VDE/VDI-Gesellschaft Mess- und Automatisierungstechnik (GMA). Wiss. Tagungsleitung: L. M. Reindl}, journal = {Sensoren und Messsysteme 2006 : Vortr{\"a}ge der 13. ITG/GMA-Fachtagung vom 13. bis 14. M{\"a}rz 2006 in Freiburg/Breisgau / Veranst.: Informationstechnische Gesellschaft im VDE (ITG) ; VDE/VDI-Gesellschaft Mess- und Automatisierungstechnik (GMA). Wiss. Tagungsleitung: L. M. Reindl}, publisher = {VDE-Verl.}, address = {Berlin}, isbn = {3-8007-2939-3}, pages = {257 -- 260}, year = {2006}, language = {de} } @inproceedings{PoghossianSchumacherKloocketal.2006, author = {Poghossian, Arshak and Schumacher, Kerstin and Kloock, Joachim P. and Rosenkranz, Christian and Schultze, Joachim W. and M{\"u}ller-Veggian, Mattea and Sch{\"o}ning, Michael Josef}, title = {Functional testing and characterisation of ISFETs on wafer level by means of a micro-droplet cell}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1259}, year = {2006}, abstract = {A wafer-level functionality testing and characterisation system for ISFETs (ionsensitive field-effect transistor) is realised by means of integration of a specifically designed capillary electrochemical micro-droplet cell into a commercial wafer prober-station. The developed system allows the identification and selection of "good" ISFETs at the earliest stage and to avoid expensive bonding, encapsulation and packaging processes for nonfunctioning ISFETs and thus, to decrease costs, which are wasted for bad dies. The developed system is also feasible for wafer-level characterisation of ISFETs in terms of sensitivity, hysteresis and response time. Additionally, the system might be also utilised for wafer-level testing of further electrochemical sensors.}, subject = {Biosensor}, language = {en} } @article{PoghossianWagnerSchoening2009, author = {Poghossian, Arshak and Wagner, Holger and Sch{\"o}ning, Michael Josef}, title = {Functional testing and characterisation of (bio-)chemical sensors on wafer level}, series = {Procedia Chemistry. 1 (2009), H. 1}, journal = {Procedia Chemistry. 1 (2009), H. 1}, isbn = {1876-6196}, pages = {835 -- 838}, year = {2009}, language = {en} } @article{PoghossianWagnerSchoening2011, author = {Poghossian, Arshak and Wagner, Holger and Sch{\"o}ning, Michael Josef}, title = {Functional testing and characterisation of (bio-)chemical sensors on wafer level}, series = {Sensors and Actuators B: Chemical. 154 (2011), H. 2}, journal = {Sensors and Actuators B: Chemical. 154 (2011), H. 2}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1873-3077}, pages = {169 -- 173}, year = {2011}, language = {en} } @article{WernerWagnerYoshinobuetal.2013, author = {Werner, Frederik and Wagner, Torsten and Yoshinobu, Tatsuo and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Frequency behaviour of light-addressable potentiometric sensors}, series = {Physica Status Solidi (A)}, volume = {210}, journal = {Physica Status Solidi (A)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-396X ; 0031-8965}, doi = {10.1002/pssa.201200929}, pages = {884 -- 891}, year = {2013}, abstract = {Light-addressable potentiometric sensors (LAPS) are semiconductor-based potentiometric sensors, with the advantage to detect the concentration of a chemical species in a liquid solution above the sensor surface in a spatially resolved manner. The addressing is achieved by a modulated and focused light source illuminating the semiconductor and generating a concentration-depending photocurrent. This work introduces a LAPS set-up that is able to monitor the electrical impedance in addition to the photocurrent. The impedance spectra of a LAPS structure, with and without illumination, as well as the frequency behaviour of the LAPS measurement are investigated. The measurements are supported by electrical equivalent circuits to explain the impedance and the LAPS-frequency behaviour. The work investigates the influence of different parameters on the frequency behaviour of the LAPS. Furthermore, the phase shift of the photocurrent, the influence of the surface potential as well as the changes of the sensor impedance will be discussed.}, language = {en} } @article{WagnerWernerMiyamotoetal.2010, author = {Wagner, Torsten and Werner, Frederik and Miyamoto, Ko-ichiro and Ackermann, Hans-Josef and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {FPGA-based LAPS device for the flexible design of sensing sites on functional interfaces}, series = {Physica Status Solidi (A). 207 (2010), H. 4}, journal = {Physica Status Solidi (A). 207 (2010), H. 4}, isbn = {1862-6300}, pages = {844 -- 849}, year = {2010}, language = {en} } @article{SchoeningBiselliSelmeretal.2012, author = {Sch{\"o}ning, Michael Josef and Biselli, Manfred and Selmer, Thorsten and {\"O}hlschl{\"a}ger, Peter and Baumann, Marcus and F{\"o}rster, Arnold and Poghossian, Arshak}, title = {Forschung „zwischen" den Disziplinen: das Institut f{\"u}r Nano- und Biotechnologien}, series = {Analytik news : das Online-Labormagazin f{\"u}r Labor und Analytik}, volume = {Publ. online}, journal = {Analytik news : das Online-Labormagazin f{\"u}r Labor und Analytik}, publisher = {Dr. Beyer Internet-Beratung}, address = {Ober-Ramstadt}, pages = {11 Seiten}, year = {2012}, abstract = {"Biologie trifft Mikroelektronik", das Motto des Instituts f{\"u}r Nano- und Biotechnologien (INB) an der FH Aachen, unterstreicht die zunehmende Bedeutung interdisziplin{\"a}r gepr{\"a}gter Forschungsaktivit{\"a}ten. Der thematische Zusammenschluss grundst{\"a}ndiger Disziplinen, wie die Physik, Elektrotechnik, Chemie, Biologie sowie die Materialwissenschaften, l{\"a}sst neue Forschungsgebiete entstehen, ein herausragendes Beispiel hierf{\"u}r ist die Nanotechnologie: Hier werden neue Werkstoffe und Materialien entwickelt, einzelne Nanopartikel oder Molek{\"u}le und deren Wechselwirkung untersucht oder Schichtstrukturen im Nanometerbereich aufgebaut, die neue und vorher nicht bekannte Eigenschaften hervorbringen. Vor diesem Hintergrund b{\"u}ndelt das im Jahre 2006 gegr{\"u}ndete INB die an der FH Aachen vorhandenen Kompetenzen von derzeit insgesamt sieben Laboratorien auf den Gebieten der Halbleitertechnik und Nanoelektronik, Nanostrukturen und DNA-Sensorik, der Chemo- und Biosensorik, der Enzymtechnologie, der Mikrobiologie und Pflanzenbiotechnologie, der Zellkulturtechnik, sowie der Roten Biotechnologie synergetisch. In der Nano- und Biotechnologie steckt außergew{\"o}hnliches Potenzial! Nicht zuletzt deshalb stellen sich die Forscher der Herausforderung, in diesem Bereich gemeinsam zu forschen und Schnittstellen zu nutzen, um so bei der Gestaltung neuartiger Ideen und Produkte mitzuwirken, die zuk{\"u}nftig unser allt{\"a}gliches Leben ver{\"a}ndern werden. Im Folgenden werden die verschiedenen Forschungsbereiche kurz zusammenfassend vorgestellt und vorhandene Interaktionen anhand von exemplarisch ausgew{\"a}hlten, aktuellen Forschungsprojekten skizziert.}, language = {de} } @article{PoghossianYoshinobuSchoening2003, author = {Poghossian, Arshak and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {Flow-velocity microsensors based on semiconductor field-effect structures}, series = {Sensors. 3 (2003), H. 7}, journal = {Sensors. 3 (2003), H. 7}, isbn = {1424-8220}, pages = {202 -- 212}, year = {2003}, language = {en} } @article{WangKrauseBlocketal.2003, author = {Wang, J. and Krause, R. and Block, K. and Musameh, M. and Mulchandani, A. and Sch{\"o}ning, Michael Josef}, title = {Flow injection amperometric detection of OP nerve agents based on organophosphorus-hydrolase biosensor detector}, series = {Biosensors \& Bioelectronics. 18 (2003), H. 2-3}, journal = {Biosensors \& Bioelectronics. 18 (2003), H. 2-3}, isbn = {0956-5663}, pages = {255 -- 260}, year = {2003}, language = {en} } @inproceedings{OberlaenderKirchnerKeusgenetal.2014, author = {Oberl{\"a}nder, Jan and Kirchner, Patrick and Keusgen, M. and Sch{\"o}ning, Michael Josef}, title = {Flexible polyimide-based calorimetric gas sensors for monitoring hy-drogen peroxide in sterilisation processes of aseptic filling machines}, series = {Sensoren und Messsysteme 2014 ; Beitr{\"a}ge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in N{\"u}rnberg. (ITG-Fachbericht ; 250)}, booktitle = {Sensoren und Messsysteme 2014 ; Beitr{\"a}ge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in N{\"u}rnberg. (ITG-Fachbericht ; 250)}, publisher = {VDE-Verl.}, address = {D{\"u}sseldorf}, organization = {VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik}, isbn = {978-3-8007-3622-5}, pages = {1 -- 4}, year = {2014}, language = {en} } @article{WagnerMiyamotoWerneretal.2011, author = {Wagner, Torsten and Miyamoto, K. and Werner, Frederik and Sch{\"o}ning, Michael Josef and Yoshinobu, T.}, title = {Flexible electrochemical imaging with "zoom-in" functionality by using a new type of light-addressable potentiometric sensor}, publisher = {IEEE}, address = {New York}, pages = {2133 -- 2135}, year = {2011}, language = {en} } @article{VahidpourOberlaenderSchoening2018, author = {Vahidpour, Farnoosh and Oberl{\"a}nder, Jan and Sch{\"o}ning, Michael Josef}, title = {Flexible Calorimetric Gas Sensors for Detection of a Broad Concentration Range of Gaseous Hydrogen Peroxide: A Step Forward to Online Monitoring of Food-Package Sterilization Processes}, series = {Phys. Status Solidi A}, volume = {215}, journal = {Phys. Status Solidi A}, number = {15}, publisher = {Wiley-VCH}, address = {Weinheim}, doi = {10.1002/pssa.201800044}, pages = {Artikel 1800044}, year = {2018}, abstract = {In this study, flexible calorimetric gas sensors are developed for specificdetection of gaseous hydrogen peroxide (H₂O₂) over a wide concentrationrange, which is used in sterilization processes for aseptic packaging industry.The flexibility of these sensors is an advantage for identifying the chemical components of the sterilant on the corners of the food boxes, so-called "coldspots", as critical locations in aseptic packaging, which are of great importance. These sensors are fabricated on flexible polyimide films by means of thin-film technique. Thin layers of titanium and platinum have been deposited on polyimide to define the conductive structures of the sensors. To detect the high-temperature evaporated H₂O₂, a differential temperature set-up is proposed. The sensors are evaluated in a laboratory-scaled sterilizationsystem to simulate the sterilization process. The concentration range of the evaporated H₂O₂ from 0 to 7.7\% v/v was defined and the sensors have successfully detected high as well as low H₂O₂ concentrations with a sensitivity of 5.04 °C/\% v/v. The characterizations of the sensors confirm their precise fabrication, high sensitivity and the novelty of low H₂O₂ concentration detections for future inline monitoring of food-package sterilization.}, language = {en} } @article{WernerSchusserSpalthahnetal.2011, author = {Werner, Frederik and Schusser, Sebastian and Spalthahn, Heiko and Wagner, Torsten and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {Field-programmable gate array based controller for multi spot light-addressable potentiometric sensors with integrated signal correction mode}, series = {Electrochimica Acta}, volume = {56}, journal = {Electrochimica Acta}, number = {26}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0013-4686}, doi = {10.1016/j.electacta.2011.03.012}, pages = {9656 -- 9660}, year = {2011}, abstract = {A light-addressable potentiometric sensor (LAPS) can measure the concentration of one or several analytes at the sensor surface simultaneously in a spatially resolved manner. A modulated light pointer stimulates the semiconductor structure at the area of interest and a responding photocurrent can be read out. By simultaneous stimulation of several areas with light pointers of different modulation frequencies, the read out can be performed at the same time. With the new proposed controller electronic based on a field-programmable gate array (FPGA), it is possible to control the modulation frequencies, phase shifts, and light brightness of multiple light pointers independently and simultaneously. Thus, it is possible to investigate the frequency response of the sensor, and to examine the analyte concentration by the determination of the surface potential with the help of current/voltage curves and phase/voltage curves. Additionally, the ability to individually change the light intensities of each light pointer is used to perform signal correction.}, language = {en} } @article{PoghossianAbouzarAmbergeretal.2007, author = {Poghossian, Arshak and Abouzar, Maryam H. and Amberger, F. and Mayer, D. and Han, Y. and Ingebrandt, S. and Offenh{\"a}usser, A. and Sch{\"o}ning, Michael Josef}, title = {Field-effect sensors with charged macromolecules: Characterisation by capacitance-voltage, constant-capacitance, impedance spectroscopy and atomic-force microscopy methods}, series = {Biosensors and Bioelectronics. 22 (2007), H. 9-10}, journal = {Biosensors and Bioelectronics. 22 (2007), H. 9-10}, isbn = {0956-5663}, pages = {2100 -- 2107}, year = {2007}, language = {en} } @inproceedings{PoghossianIngebrandtPlatenetal.2006, author = {Poghossian, Arshak and Ingebrandt, S. and Platen, J. and Sch{\"o}ning, Michael Josef}, title = {Field-effect sensors with charged macromolecules - from micro towards nano aspects}, series = {Biochemical Sensing Utilisation of Micro-and Nanotechnologies, Warschau, Nov. 2005 : Lecture Notes of the ICB Seminar / ed.: M. Mascini, W. Torbicz}, booktitle = {Biochemical Sensing Utilisation of Micro-and Nanotechnologies, Warschau, Nov. 2005 : Lecture Notes of the ICB Seminar / ed.: M. Mascini, W. Torbicz}, publisher = {Polish Academy Sciences Press}, address = {Warsaw}, pages = {74 -- 81}, year = {2006}, language = {en} } @article{PoghossianJablonskiMolinnusetal.2020, author = {Poghossian, Arshak and Jablonski, Melanie and Molinnus, Denise and Wege, Christina and Sch{\"o}ning, Michael Josef}, title = {Field-Effect Sensors for Virus Detection: From Ebola to SARS-CoV-2 and Plant Viral Enhancers}, series = {Frontiers in Plant Science}, volume = {11}, journal = {Frontiers in Plant Science}, number = {Article 598103}, publisher = {Frontiers}, address = {Lausanne}, doi = {10.3389/fpls.2020.598103}, pages = {1 -- 14}, year = {2020}, abstract = {Coronavirus disease 2019 (COVID-19) is a novel human infectious disease provoked by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Currently, no specific vaccines or drugs against COVID-19 are available. Therefore, early diagnosis and treatment are essential in order to slow the virus spread and to contain the disease outbreak. Hence, new diagnostic tests and devices for virus detection in clinical samples that are faster, more accurate and reliable, easier and cost-efficient than existing ones are needed. Due to the small sizes, fast response time, label-free operation without the need for expensive and time-consuming labeling steps, the possibility of real-time and multiplexed measurements, robustness and portability (point-of-care and on-site testing), biosensors based on semiconductor field-effect devices (FEDs) are one of the most attractive platforms for an electrical detection of charged biomolecules and bioparticles by their intrinsic charge. In this review, recent advances and key developments in the field of label-free detection of viruses (including plant viruses) with various types of FEDs are presented. In recent years, however, certain plant viruses have also attracted additional interest for biosensor layouts: Their repetitive protein subunits arranged at nanometric spacing can be employed for coupling functional molecules. If used as adapters on sensor chip surfaces, they allow an efficient immobilization of analyte-specific recognition and detector elements such as antibodies and enzymes at highest surface densities. The display on plant viral bionanoparticles may also lead to long-time stabilization of sensor molecules upon repeated uses and has the potential to increase sensor performance substantially, compared to conventional layouts. This has been demonstrated in different proof-of-concept biosensor devices. Therefore, richly available plant viral particles, non-pathogenic for animals or humans, might gain novel importance if applied in receptor layers of FEDs. These perspectives are explained and discussed with regard to future detection strategies for COVID-19 and related viral diseases.}, language = {en} } @article{PoghossianAbouzarSakkarietal.2006, author = {Poghossian, Arshak and Abouzar, Maryam H. and Sakkari, M. and Kassab, T. and Han, Y. and Ingebrandt, S. and Offenh{\"a}usser, A. and Sch{\"o}ning, Michael Josef}, title = {Field-effect sensors for monitoring the layer-by-layer adsorption of charged macromolecules}, series = {Sensors and Actuators B: Chemical. 118 (2006), H. 1-2}, journal = {Sensors and Actuators B: Chemical. 118 (2006), H. 1-2}, isbn = {0925-4005}, pages = {163 -- 170}, year = {2006}, language = {en} } @article{YoshinobuMiyamotoWagneretal.2024, author = {Yoshinobu, Tatsuo and Miyamoto, Ko-ichiro and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Field-effect sensors combined with the scanned light pulse technique: from artificial olfactory images to chemical imaging technologies}, series = {Chemosensors}, volume = {12}, journal = {Chemosensors}, number = {2}, publisher = {MDPI}, address = {Basel}, issn = {2227-9040}, doi = {10.3390/chemosensors12020020}, pages = {Artikel 20}, year = {2024}, abstract = {The artificial olfactory image was proposed by Lundstr{\"o}m et al. in 1991 as a new strategy for an electronic nose system which generated a two-dimensional mapping to be interpreted as a fingerprint of the detected gas species. The potential distribution generated by the catalytic metals integrated into a semiconductor field-effect structure was read as a photocurrent signal generated by scanning light pulses. The impact of the proposed technology spread beyond gas sensing, inspiring the development of various imaging modalities based on the light addressing of field-effect structures to obtain spatial maps of pH distribution, ions, molecules, and impedance, and these modalities have been applied in both biological and non-biological systems. These light-addressing technologies have been further developed to realize the position control of a faradaic current on the electrode surface for localized electrochemical reactions and amperometric measurements, as well as the actuation of liquids in microfluidic devices.}, language = {en} } @article{AbouzarIngebrandtPoghossianetal.2009, author = {Abouzar, Maryam H. and Ingebrandt, S. and Poghossian, Arshak and Zhang, Y. and Moritz, W. and Sch{\"o}ning, Michael Josef}, title = {Field-effect nanoplate capacitive pH sensor based on SOI structure}, series = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, journal = {Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009}, pages = {55 -- 58}, year = {2009}, language = {en} }