@article{NoureddineKraffLaddetal.2017, author = {Noureddine, Yacine and Kraff, Oliver and Ladd, Mark E. and Wrede, Karsten H. and Chen, Bixia and Quick, Harald H. and Schaefers, Gregor and Bitz, Andreas}, title = {In vitro and in silico assessment of RF-induced heating around intracranial aneurysm clips at 7 Tesla}, series = {Magnetic Resonance in Medicine}, journal = {Magnetic Resonance in Medicine}, number = {Early view}, publisher = {Wiley}, address = {Weinheim}, issn = {1522-2594}, doi = {10.1002/mrm.26650}, pages = {14 Seiten}, year = {2017}, language = {en} } @article{NoureddineKraffLaddetal.2019, author = {Noureddine, Yacine and Kraff, Oliver and Ladd, Mark E. and Wrede, Karsten and Chen, Bixia and Quick, Harald H. and Schaefers, Georg and Bitz, Andreas}, title = {Radiofrequency induced heating around aneurysm clips using a generic birdcage head coil at 7 Tesla under consideration of the minimum distance to decouple multiple aneurysm clips}, series = {Magnetic Resonance in Medicine}, journal = {Magnetic Resonance in Medicine}, number = {Early view}, publisher = {Wiley}, address = {Weinheim}, issn = {1522-2594}, doi = {10.1002/mrm.27835}, pages = {1 -- 17}, year = {2019}, language = {en} } @article{NoureddineBitzLaddetal.2015, author = {Noureddine, Yacine and Bitz, Andreas and Ladd, Mark E. and Th{\"u}rling, Markus and Ladd, Susanne C. and Schaefers, Gregor and Kraff, Oliver}, title = {Experience with magnetic resonance imaging of human subjects with passive implants and tattoos at 7 T: a retrospective study}, series = {Magnetic Resonance Materials in Physics, Biology and Medicine}, volume = {28}, journal = {Magnetic Resonance Materials in Physics, Biology and Medicine}, number = {6}, publisher = {Springer}, address = {Berlin}, issn = {1352-8661}, doi = {10.1007/s10334-015-0499-y}, pages = {577 -- 590}, year = {2015}, language = {en} } @article{NiemuellerLakemeyerFerreinetal.2013, author = {Niem{\"u}ller, Tim and Lakemeyer, Gerhard and Ferrein, Alexander and Reuter, S. and Ewert, D. and Jeschke, S. and Pensky, D. and Karras, Ulrich}, title = {Proposal for advancements to the LLSF in 2014 and beyond}, pages = {Publ. online}, year = {2013}, language = {en} } @article{NiemuellerFerreinLakemeyer2010, author = {Niem{\"u}ller, Tim and Ferrein, Alexander and Lakemeyer, Gerhard}, title = {A Lua-based Behavior Engine for Controlling the Humanoid Robot Nao}, series = {RoboCup 2009: Robot Soccer World Cup XIII}, journal = {RoboCup 2009: Robot Soccer World Cup XIII}, pages = {240 -- 251}, year = {2010}, language = {en} } @article{NiemuellerFerreinEckeletal.2011, author = {Niem{\"u}ller, Tim and Ferrein, Alexander and Eckel, Gerhard and Pirro, David and Podbregar, Patrick and Kellner, Tobias and Rath, Christoph and Steinbauer, Gerald}, title = {Providing Ground-truth Data for the Nao Robot Platform}, series = {RoboCup 2010: Robot Soccer World Cup XIV}, journal = {RoboCup 2010: Robot Soccer World Cup XIV}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-642-20217-9}, pages = {133 -- 144}, year = {2011}, language = {en} } @article{NiemuellerFerreinBecketal.2010, author = {Niem{\"u}ller, Tim and Ferrein, Alexander and Beck, Daniel and Lakemeyer, Gerhard}, title = {Design Principles of the Component-Based Robot Software Framework Fawkes}, series = {Simulation, Modeling, and Programming for Autonomous Robots}, journal = {Simulation, Modeling, and Programming for Autonomous Robots}, pages = {300 -- 311}, year = {2010}, language = {en} } @article{NdoumbeMbonjoMbonjoStreckertBitzetal.2004, author = {Ndoumb{\`e} Mbonjo Mbonjo, H. and Streckert, J. and Bitz, Andreas and Hansen, V. and Glasmachers, A. and Gencol, S. and Rozic, D.}, title = {Generic UMTS test signal for RF bioelectromagnetic studies}, series = {Bioelectromagnetics}, volume = {25}, journal = {Bioelectromagnetics}, number = {6}, issn = {1521-186X}, doi = {10.1002/bem.20007}, pages = {415 -- 425}, year = {2004}, language = {en} } @article{MuellerLeiseLorenzetal.2020, author = {M{\"u}ller, Tim M. and Leise, Philipp and Lorenz, Imke-Sophie and Altherr, Lena and Pelz, Peter F.}, title = {Optimization and validation of pumping system design and operation for water supply in high-rise buildings}, series = {Optimization and Engineering}, volume = {2021}, journal = {Optimization and Engineering}, number = {22}, publisher = {Springer}, issn = {1573-2924}, doi = {10.1007/s11081-020-09553-4}, pages = {643 -- 686}, year = {2020}, abstract = {The application of mathematical optimization methods for water supply system design and operation provides the capacity to increase the energy efficiency and to lower the investment costs considerably. We present a system approach for the optimal design and operation of pumping systems in real-world high-rise buildings that is based on the usage of mixed-integer nonlinear and mixed-integer linear modeling approaches. In addition, we consider different booster station topologies, i.e. parallel and series-parallel central booster stations as well as decentral booster stations. To confirm the validity of the underlying optimization models with real-world system behavior, we additionally present validation results based on experiments conducted on a modularly constructed pumping test rig. Within the models we consider layout and control decisions for different load scenarios, leading to a Deterministic Equivalent of a two-stage stochastic optimization program. We use a piecewise linearization as well as a piecewise relaxation of the pumps' characteristics to derive mixed-integer linear models. Besides the solution with off-the-shelf solvers, we present a problem specific exact solving algorithm to improve the computation time. Focusing on the efficient exploration of the solution space, we divide the problem into smaller subproblems, which partly can be cut off in the solution process. Furthermore, we discuss the performance and applicability of the solution approaches for real buildings and analyze the technical aspects of the solutions from an engineer's point of view, keeping in mind the economically important trade-off between investment and operation costs.}, language = {en} } @article{MuehlBinneboeselKlingeetal.2008, author = {M{\"u}hl, Thomas and Binneb{\"o}sel, Marcel and Klinge, Uwe and Goedderz, Thomas}, title = {New objective measurement to characterize the porosity of textile implants}, series = {Journal of Biomedical Materials Research Part B: Applied Biomaterials. 84B (2008), H. 1}, journal = {Journal of Biomedical Materials Research Part B: Applied Biomaterials. 84B (2008), H. 1}, isbn = {1552-4981}, pages = {176 -- 183}, year = {2008}, language = {en} } @article{Mayer1997, author = {Mayer, Claudia}, title = {L'Est{\´e}tique et le pouvoir: Le discours chaotique de l'Allemagne unifi{\´e}e}, series = {Canadian review of comparative literature : CRCL = Revue canadienne de litt{\´e}rature compar{\´e}e : RCLC / Canadian Comparative Literature Association. 24 (1997), H. 2}, journal = {Canadian review of comparative literature : CRCL = Revue canadienne de litt{\´e}rature compar{\´e}e : RCLC / Canadian Comparative Literature Association. 24 (1997), H. 2}, isbn = {0319-051X}, pages = {297 -- 317}, year = {1997}, language = {en} } @article{Mayer1993, author = {Mayer, Claudia}, title = {Between Trans- and Interdisciplinarity. »Germanistik« and the Dialectic of Inclusion and Exclusion of the Other(s)}, series = {Language and literature today : proceedings of the XIXth triennal congress of the International Federation for Modern Languages and Literatures ; Bras{\´i}lia 22 - 30 August 1993. General ed. Neide de Faria.}, journal = {Language and literature today : proceedings of the XIXth triennal congress of the International Federation for Modern Languages and Literatures ; Bras{\´i}lia 22 - 30 August 1993. General ed. Neide de Faria.}, publisher = {Univ.}, address = {Brasilia}, isbn = {85-230-0405-x}, pages = {958 -- 966}, year = {1993}, language = {en} } @article{Mayer1995, author = {Mayer, Claudia}, title = {Between Resistance and Affirmation: Christa Wolf and German Unification}, series = {Canadian review of comparative literature : CRCL = Revue canadienne de litt{\´e}rature compar{\´e}e / Canadian Comparative Literature Association. 22 (1995), H. 3-4}, journal = {Canadian review of comparative literature : CRCL = Revue canadienne de litt{\´e}rature compar{\´e}e / Canadian Comparative Literature Association. 22 (1995), H. 3-4}, isbn = {0319-051X}, pages = {813 -- 835}, year = {1995}, language = {en} } @article{MausHoefkenSchuba2011, author = {Maus, Stefan and H{\"o}fken, Hans-Wilhelm and Schuba, Marko}, title = {Forensic Analysis of Geodata in Android Smartphones}, pages = {1 -- 11}, year = {2011}, language = {en} } @article{MaasVosLagemaatetal.2014, author = {Maas, Marnix C. and Vos, Eline K. and Lagemaat, Miriam W. and Bitz, Andreas and Orzada, Stephan and Kobus, Thiele and Kraff, Oliver and Maderwald, Stefan and Ladd, Mark E. and Scheenen, Tom W. J.}, title = {Feasibility of T₂-weighted turbo spin echo imaging of the human prostate at 7 tesla}, series = {Magnetic Resonance in Medicine}, volume = {71}, journal = {Magnetic Resonance in Medicine}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1522-2594}, doi = {10.1002/mrm.24818}, pages = {1711 -- 1719}, year = {2014}, abstract = {Purpose To demonstrate that high quality T₂-weighted (T2w) turbo spin-echo (TSE) imaging of the complete prostate can be achieved routinely and within safety limits at 7 T, using an external transceive body array coil only. Methods Nine healthy volunteers and 12 prostate cancer patients were scanned on a 7 T whole-body system. Preparation consisted of B₀ and radiofrequency shimming and localized flip angle calibration. T₁ and T₂ relaxation times were measured and used to define the T2w-TSE protocol. T2w imaging was performed using a TSE sequence (pulse repetition time/echo time 3000-3640/71 ms) with prolonged excitation and refocusing pulses to reduce specific absorption rate. Results High quality T2w TSE imaging was performed in less than 2 min in all subjects. Tumors of patients with gold-standard tumor localization (MR-guided biopsy or prostatectomy) were well visualized on 7 T imaging (n = 3). The number of consecutive slices achievable within a 10-g averaged specific absorption rate limit of 10 W/kg was ≥28 in all subjects, sufficient for full prostate coverage with 3-mm slices in at least one direction. Conclusion High quality T2w TSE prostate imaging can be performed routinely and within specific absorption rate limits at 7 T with an external transceive body array.}, language = {en} } @article{LimpertWiesenFerreinetal.2019, author = {Limpert, Nicolas and Wiesen, Patrick and Ferrein, Alexander and Kallweit, Stephan and Schiffer, Stefan}, title = {The ROSIN Project and its Outreach to South Africa}, series = {R\&D Journal}, volume = {35}, journal = {R\&D Journal}, pages = {1 -- 6}, year = {2019}, language = {en} } @article{LerchlKruegerNiehausetal.2008, author = {Lerchl, Alexander and Kr{\"u}ger, Heike and Niehaus, Michael and Streckert, Joachim R. and Bitz, Andreas and Hansen, Volkert}, title = {Effects of mobile phone electromagnetic fields at nonthermal SAR values on melatonin and body weight of Djungarian hamsters (Phodopus sungorus)}, series = {Journal of Pineal Research}, volume = {44}, journal = {Journal of Pineal Research}, number = {3}, issn = {1600-079X}, doi = {10.1111/j.1600-079X.2007.00522.x}, pages = {267 -- 272}, year = {2008}, language = {en} } @article{LeiseEsserEichenlaubetal.2021, author = {Leise, Philipp and Eßer, Arved and Eichenlaub, Tobias and Schleiffer, Jean-Eric and Altherr, Lena and Rinderknecht, Stephan and Pelz, Peter F.}, title = {Sustainable system design of electric powertrains - comparison of optimization methods}, series = {Engineering Optimization}, journal = {Engineering Optimization}, publisher = {Taylor \& Francis}, address = {London}, issn = {0305-215X}, doi = {10.1080/0305215X.2021.1928660}, year = {2021}, abstract = {The transition within transportation towards battery electric vehicles can lead to a more sustainable future. To account for the development goal 'climate action' stated by the United Nations, it is mandatory, within the conceptual design phase, to derive energy-efficient system designs. One barrier is the uncertainty of the driving behaviour within the usage phase. This uncertainty is often addressed by using a stochastic synthesis process to derive representative driving cycles and by using cycle-based optimization. To deal with this uncertainty, a new approach based on a stochastic optimization program is presented. This leads to an optimization model that is solved with an exact solver. It is compared to a system design approach based on driving cycles and a genetic algorithm solver. Both approaches are applied to find efficient electric powertrains with fixed-speed and multi-speed transmissions. Hence, the similarities, differences and respective advantages of each optimization procedure are discussed.}, language = {en} } @article{LeingartnerMaurerFerreinetal.2016, author = {Leingartner, Max and Maurer, Johannes and Ferrein, Alexander and Steinbauer, Gerald}, title = {Evaluation of Sensors and Mapping Approaches for Disasters in Tunnels}, series = {Journal of Field Robotics}, volume = {33}, journal = {Journal of Field Robotics}, number = {8}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1556-4967}, doi = {10.1002/rob.21611}, pages = {1037 -- 1057}, year = {2016}, abstract = {Ground or aerial robots equipped with advanced sensing technologies, such as three-dimensional laser scanners and advanced mapping algorithms, are deemed useful as a supporting technology for first responders. A great deal of excellent research in the field exists, but practical applications at real disaster sites are scarce. Many projects concentrate on equipping robots with advanced capabilities, such as autonomous exploration or object manipulation. In spite of this, realistic application areas for such robots are limited to teleoperated reconnaissance or search. In this paper, we investigate how well state-of-the-art and off-the-shelf components and algorithms are suited for reconnaissance in current disaster-relief scenarios. The basic idea is to make use of some of the most common sensors and deploy some widely used algorithms in a disaster situation, and to evaluate how well the components work for these scenarios. We acquired the sensor data from two field experiments, one from a disaster-relief operation in a motorway tunnel, and one from a mapping experiment in a partly closed down motorway tunnel. Based on these data, which we make publicly available, we evaluate state-of-the-art and off-the-shelf mapping approaches. In our analysis, we integrate opinions and replies from first responders as well as from some algorithm developers on the usefulness of the data and the limitations of the deployed approaches, respectively. We discuss the lessons we learned during the two missions. These lessons are interesting for the community working in similar areas of urban search and rescue, particularly reconnaissance and search.}, language = {en} } @article{LagemaatVosMaasetal.2014, author = {Lagemaat, Miriam W. and Vos, Eline K. and Maas, Marnix C. and Bitz, Andreas and Orzada, Stephan and Uden, Mark J. van and Kobus, Thiele and Heerschap, Arend and Scheenen, Tom W. J.}, title = {Phosphorus magnetic resonance spectroscopic imaging at 7 T in patients with prostate cancer}, series = {Investigative Radiology}, volume = {49}, journal = {Investigative Radiology}, number = {5}, publisher = {Lippincott Williams \& Wilkins}, address = {Philadelphia, Pa.}, issn = {1536-0210}, doi = {10.1097/RLI.0000000000000012}, pages = {363 -- 372}, year = {2014}, abstract = {Objectives The aim of this study was to identify characteristics of phosphorus (³¹P) spectra of the human prostate and to investigate changes of individual phospholipid metabolites in prostate cancer through in vivo ³¹P magnetic resonance spectroscopic imaging (MRSI) at 7 T. Materials and Methods In this institutional review board-approved study, 15 patients with biopsy-proven prostate cancer underwent T₂-weighted magnetic resonance imaging and 3-dimensional ³¹P MRSI at 7 T. Voxels were selected at the tumor location, in normal-appearing peripheral zone tissue, normal-appearing transition zone tissue, and in the base of the prostate close to the seminal vesicles. Phosphorus metabolite ratios were determined and compared between tissue types. Results Signals of phosphoethanolamine (PE) and phosphocholine (PC) were present and well resolved in most ³¹P spectra in the prostate. Glycerophosphocholine signals were observable in 43\% of the voxels in malignant tissue, but in only 10\% of the voxels in normal-appearing tissue away from the seminal vesicles. In many spectra, independent of tissue type, 2 peaks resonated in the chemical shift range of inorganic phosphate, possibly representing 2 separate pH compartments. The PC/PE ratio in the seminal vesicles was highly elevated compared with the prostate in 5 patients. A considerable overlap of ³¹P metabolite ratios was found between prostate cancer and normal-appearing prostate tissue, preventing direct discrimination of these tissues. The only 2 patients with high Gleason scores tumors (≥4+5) presented with high PC and glycerophosphocholine levels in their cancer lesions. Conclusions Phosphorus MRSI at 7 T shows distinct features of phospholipid metabolites in the prostate gland and its surrounding structures. In this exploratory study, no differences in ³¹P metabolite ratios were observed between prostate cancer and normal-appearing prostate tissue possibly because of the partial volume effects of small tumor foci in large MRSI voxels.}, language = {en} } @article{LagemaatMaasVosetal.2015, author = {Lagemaat, Miriam W. and Maas, Marnix C. and Vos, Eline K. and Bitz, Andreas and Orzada, Stephan and Weiland, Elisabeth and Uden, Mark J. van and Kobus, Thiele and Heerschap, Arend and Scheenen, Tom W. J.}, title = {(31) P MR spectroscopic imaging of the human prostate at 7 T: T1 relaxation times, Nuclear Overhauser Effect, and spectral characterization}, series = {Magnetic Resonance in Medicine}, volume = {73}, journal = {Magnetic Resonance in Medicine}, number = {3}, publisher = {Wiley}, address = {Weinheim}, issn = {1522-2594}, doi = {10.1002/mrm.25209}, pages = {909 -- 920}, year = {2015}, language = {en} } @article{LagemaatBreukelsVosetal.2016, author = {Lagemaat, Miriam W. and Breukels, Vincent and Vos, Eline K. and B., Adam and Uden, Mark J. van and Orzada, Stephan and Bitz, Andreas and Maas, Marnix C. and Scheenen, Tom W. J.}, title = {¹H MR spectroscopic imaging of the prostate at 7T using spectral-spatial pulses}, series = {Magnetic Resonance in Medicine}, volume = {75}, journal = {Magnetic Resonance in Medicine}, number = {3}, publisher = {International Society for Magnetic Resonance in Medicine}, issn = {1522-2594}, doi = {10.1002/mrm.25569}, pages = {933 -- 945}, year = {2016}, abstract = {Purpose To assess the feasibility of prostate ¹H MR spectroscopic imaging (MRSI) using low-power spectral-spatial (SPSP) pulses at 7T, exploiting accurate spectral selection and spatial selectivity simultaneously. Methods A double spin-echo sequence was equipped with SPSP refocusing pulses with a spectral selectivity of 1 ppm. Three-dimensional prostate ¹H-MRSI at 7T was performed with the SPSP-MRSI sequence using an 8-channel transmit array coil and an endorectal receive coil in three patients with prostate cancer and in one healthy subject. No additional water or lipid suppression pulses were used. Results Prostate ¹H-MRSI could be obtained well within specific absorption rate (SAR) limits in a clinically feasible time (10 min). Next to the common citrate signals, the prostate spectra exhibited high spermine signals concealing creatine and sometimes also choline. Residual lipid signals were observed at the edges of the prostate because of limitations in spectral and spatial selectivity. Conclusion It is possible to perform prostate ¹H-MRSI at 7T with a SPSP-MRSI sequence while using separate transmit and receive coils. This low-SAR MRSI concept provides the opportunity to increase spatial resolution of MRSI within reasonable scan times.}, language = {en} } @article{KoenigWolf2018, author = {K{\"o}nig, Johannes Alexander and Wolf, Martin}, title = {GHOST: An Evaluated Competence Developing Game for Cybersecurity Awareness Training}, series = {International Journal on Advances in Security}, volume = {11}, journal = {International Journal on Advances in Security}, number = {3 \& 4}, publisher = {IARIA Journals}, issn = {1942-2636}, pages = {274 -- 287}, year = {2018}, abstract = {To train end users how to interact with digital systems is indispensable to ensure a strong computer security. 'Competence Developing Game'-based approaches are particularly suitable for this purpose because of their motivation-and simulation-aspects. In this paper the Competence Developing Game 'GHOST' for cybersecurity awareness trainings and its underlying patterns are described. Accordingly, requirements for an 'Competence Developing Game' based training are discussed. Based on these requirements it is shown how a game can fulfill these requirements. A supplementary game interaction design and a corresponding evaluation study is shown. The combination of training requirements and interaction design is used to create a 'Competence Developing Game'-based training concept. A part of these concept is implemented into a playable prototype that serves around one hour of play respectively training time. This prototype is used to perform an evaluation of the game and training aspects of the awareness training. Thereby, the quality of the game aspect and the effectiveness of the training aspect are shown.}, language = {en} } @article{KoellenspergerBragardPlumetal.2009, author = {K{\"o}llensperger, P. and Bragard, Michael and Plum, T. and De Doncker, R. W.}, title = {The dual GCT : new high-power device using optimized GCT technology}, series = {IEEE transactions on industry applications}, volume = {45}, journal = {IEEE transactions on industry applications}, number = {5}, issn = {0093-9994}, doi = {10.1109/TIA.2009.2027364}, pages = {1754 -- 1762}, year = {2009}, language = {en} } @article{KoehlerRoepkeWolf2021, author = {K{\"o}hler, Klemens and R{\"o}pke, Ren{\´e} and Wolf, Martin}, title = {Through a mirror darkly - On the obscurity of teaching goals in game-based learning in IT security}, series = {ISAGA 2019: Simulation Gaming Through Times and Disciplines}, journal = {ISAGA 2019: Simulation Gaming Through Times and Disciplines}, publisher = {Springer}, address = {Cham}, doi = {10.1007/978-3-030-72132-9_6}, pages = {61 -- 73}, year = {2021}, abstract = {Teachers and instructors use very specific language communicating teaching goals. The most widely used frameworks of common reference are the Bloom's Taxonomy and the Revised Bloom's Taxonomy. The latter provides distinction of 209 different teaching goals which are connected to methods. In Competence Developing Games (CDGs - serious games to convey knowledge) and in IT security education, a two- or three level typology exists, reducing possible learning outcomes to awareness, training, and education. This study explores whether this much simpler framework succeeds in achieving the same range of learning outcomes. Method wise a keyword analysis was conducted. The results were threefold: 1. The words used to describe teaching goals in CDGs on IT security education do not reflect the whole range of learning outcomes. 2. The word choice is nevertheless different from common language, indicating an intentional use of language. 3. IT security CDGs use different sets of terms to describe learning outcomes, depending on whether they are awareness, training, or education games. The interpretation of the findings is that the reduction to just three types of CDGs reduces the capacity to communicate and think about learning outcomes and consequently reduces the outcomes that are intentionally achieved.}, language = {en} } @article{Koehler2020, author = {K{\"o}hler, Klemens}, title = {A conflict theory perspective of IT attacks - consequences for IT security education}, number = {Preprint}, year = {2020}, abstract = {Cyberspace is "the environment formed by physical and non-physical components to store, modify, and exchange data using computer networks" (NATO CCDCOE). Beyond that, it is an environment where people interact. IT attacks are hostile, non-cooperative interactions that can be described with conflict theory. Applying conflict theory to IT security leads to different objectives for end-user education, requiring different formats like agency-based competence developing games.}, language = {en} } @article{KrauseSchuppeSaureetal.1988, author = {Krause, Gregor and Schuppe, W.D. and Saure, M. and Andress, H.}, title = {Sensitive Analytical and Physical Methods for Diagnosis of Variations in Polyolefin Plaques and Cable Insulations / W.D. Schuppe, M. Saure, H. Andress, K. M{\"o}ller, D. Meurer, G. Krause}, series = {Proceedings of the 32nd session : 28th August - 3rd September.}, journal = {Proceedings of the 32nd session : 28th August - 3rd September.}, year = {1988}, language = {en} } @article{KrauseRodriguezStopicetal.2007, author = {Krause, Gregor and Rodriguez, Jackson and Stopic, Srecko and Friedrich, Bernd}, title = {Feasibility assessment of electrocoagulation towards a new sustainable wastewater treatment / Rodriguez, Jackson ; Stopic, Srecko ; Krause Gregor ; Friedrich, Bernd}, series = {Environmental Science and Pollution Research. 14 (2007), H. 7}, journal = {Environmental Science and Pollution Research. 14 (2007), H. 7}, isbn = {0944-1344}, pages = {477 -- 482}, year = {2007}, language = {en} } @article{KrauseNeubertPietsch1990, author = {Krause, Gregor and Neubert, R. and Pietsch, R.}, title = {Investigations of Electrical Aging in Polymers under High AC-Field Strength}, series = {1990 annual report : October 28 - October 31, 1990 / sponsored by the IEEE Dielectrics and Electrical Insulation Society}, journal = {1990 annual report : October 28 - October 31, 1990 / sponsored by the IEEE Dielectrics and Electrical Insulation Society}, publisher = {IEEE Service Center}, address = {Piscataway, N.J}, pages = {716 S : Ill., graph. Darst.}, year = {1990}, language = {en} } @article{KrauseMoellerMeurer1989, author = {Krause, Gregor and M{\"o}ller, K. and Meurer, D.}, title = {Dielectric phenomena in semicrystalline polymers}, series = {IEEE Transaction on Electrical Insulation. Vol. 24 (1989), H. No. 2}, journal = {IEEE Transaction on Electrical Insulation. Vol. 24 (1989), H. No. 2}, pages = {215 -- 222}, year = {1989}, language = {en} } @article{KrauseMeurerKlee1988, author = {Krause, Gregor and Meurer, D. and Klee, D.}, title = {Space Charge Formation Related to the Morphology of Polymers}, series = {ISE 6 : 6th International symposium on electrets : Papers}, journal = {ISE 6 : 6th International symposium on electrets : Papers}, publisher = {IEEE}, address = {Piscataway, NY}, pages = {XIX, 688 S. : graph. Darst.}, year = {1988}, language = {en} } @article{KrauseMeurerKlee1989, author = {Krause, Gregor and Meurer, D. and Klee, D.}, title = {Space charge formation related to the morphology of polymers}, series = {IEEE Transaction on Electrical Insulation. Vol. 24 (1989), H. No. 3}, journal = {IEEE Transaction on Electrical Insulation. Vol. 24 (1989), H. No. 3}, pages = {215 -- 222}, year = {1989}, language = {en} } @article{KrauseGoettlichMoelleretal.1989, author = {Krause, Gregor and G{\"o}ttlich, S. and M{\"o}ller, K. and Meurer, D.}, title = {Space Charge Phenomena in Partially Crystalline Polymers: On-Line Measurement of Charge Carrier Motion under High AC-Field Strength / G. Krause, S. G{\"o}ttlich, K. M{\"o}ller, D. Meurer}, series = {Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics : Trondheim, Norway ... 1989}, journal = {Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics : Trondheim, Norway ... 1989}, publisher = {IEEE}, address = {Piscataway, N.J.}, pages = {IX, 607 S.}, year = {1989}, language = {en} } @article{KrauseFruth1987, author = {Krause, Gregor and Fruth, Bernhard}, title = {Dielectric Properties of Polyolefins Stressed by High Electrical Fields. Fruth, B. ; Krause, G.}, year = {1987}, language = {en} } @article{KrauseFruth1988, author = {Krause, Gregor and Fruth, B.}, title = {Dielectric Properties of Polyolefins Stressed by High Electrical Fields / Fruth, B. ; Krause, G.}, series = {Plenary lectures and contributions presented at the International Symposium on Polymer Materials : held in San Sebastian (Donostia), Spain, 31 August - 4 September, 1987 / symposium ed. G. M. Guzm{\´a}n ; A. Santamaria}, journal = {Plenary lectures and contributions presented at the International Symposium on Polymer Materials : held in San Sebastian (Donostia), Spain, 31 August - 4 September, 1987 / symposium ed. G. M. Guzm{\´a}n ; A. Santamaria}, publisher = {Huethig \& Wepf}, address = {Basel}, isbn = {3-85739-220-7}, pages = {XIV, 629 S.}, year = {1988}, language = {en} } @article{Krause1991, author = {Krause, Gregor}, title = {High Field Phenomena of Polymeric Insulation Investigated at PE Needle-Plane Specimen}, series = {Seventh International Symposium on High Voltage Engineering : Dresden, August 26 - 30, 1991 / Technische Universit{\"a}t Dresden}, journal = {Seventh International Symposium on High Voltage Engineering : Dresden, August 26 - 30, 1991 / Technische Universit{\"a}t Dresden}, publisher = {TU Dresden}, address = {Dresden}, year = {1991}, language = {en} } @article{KraffWredeSchoembergetal.2013, author = {Kraff, Oliver and Wrede, Karsten H. and Schoemberg, Tobias and Dammann, Philipp and Noureddine, Yacine and Orzada, Stephan and Ladd, Mark E. and Bitz, Andreas}, title = {MR safety assessment of potential RF heating from cranial fixation plates at 7 T}, series = {Medical Physics}, volume = {40}, journal = {Medical Physics}, number = {4}, publisher = {Wiley}, address = {Hoboken}, issn = {2473-4209}, doi = {10.1118/1.4795347}, pages = {042302-1 -- 042302-10}, year = {2013}, language = {en} } @article{KraffBitzKruszonaetal.2009, author = {Kraff, Oliver and Bitz, Andreas and Kruszona, Stefan and Orzada, Stephan and Schaefer, Lena C. and Theysohn, Jens M. and Maderwald, Stefan and Ladd, Mark E. and Quick, Harald H.}, title = {An eight-channel phased array RF coil for spine MR imaging at 7 T}, series = {Investigative Radiology}, volume = {44}, journal = {Investigative Radiology}, number = {11}, publisher = {Lippincott Williams \& Wilkins}, issn = {1536-0210}, doi = {10.1097/RLI.0b013e3181b24ab7}, pages = {734 -- 740}, year = {2009}, language = {en} } @article{KraffBitzDammannetal.2010, author = {Kraff, Oliver and Bitz, Andreas and Dammann, Philipp and Ladd, Susanne C. and Ladd, Mark E. and Quick, Harald H.}, title = {An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T}, series = {Medical Physics}, volume = {37}, journal = {Medical Physics}, number = {12}, publisher = {Wiley}, address = {Hoboken, NJ}, issn = {2473-4209}, doi = {10.1118/1.3517176}, pages = {6368 -- 6376}, year = {2010}, abstract = {Purpose: MRI plays a leading diagnostic role in assessing the musculoskeletal (MSK) system and is well established for most questions at clinically used field strengths (up to 3 T). However, there are still limitations in imaging early stages of cartilage degeneration, very fine tendons and ligaments, or in locating nerve lesions, for example. 7 T MRI of the knee has already received increasing attention in the current published literature, but there is a strong need to develop new radiofrequency (RF) coils to assess more regions of the MSK system. In this work, an eight-channel transmit/receive RF array was built as a multipurpose coil for imaging some of the thus far neglected regions. An extensive coil characterization protocol and first in vivo results of the human wrist, shoulder, elbow, knee, and ankle imaged at 7 T will be presented. Methods: Eight surface loop coils with a dimension ofurn:x-wiley:00942405:media:mp7176:mp7176-math-0001 were machined from FR4 circuit board material. To facilitate easy positioning, two coil clusters, each with four loop elements, were combined to one RF transmit/receive array. An overlapped and shifted arrangement of the coil elements was chosen to reduce the mutual inductance between neighboring coils. A phantom made of body-simulating liquid was used for tuning and matching on the bench. Afterward, the S-parameters were verified on a human wrist, elbow, and shoulder. For safety validation, a detailed compliance test was performed including full wave simulations of the RF field distribution and the corresponding specific absorption rate (SAR) for all joints. In vivo images of four volunteers were assessed with gradient echo and spin echo sequences modified to obtain optimal image contrast, full anatomic coverage, and the highest spatial resolution within a reasonable acquisition time. The performance of the RF coil was additionally evaluated by in vivo B1 mapping. Results: A comparison of B1 per unit power, flip angle distribution, and anatomic images showed a fairly homogeneous excitation for the smaller joints (elbow, wrist, and ankle), while for the larger joints, the shoulder and especially the knee, B1 inhomogeneities and limited penetration depth were more pronounced. However, the greater part of the shoulder joint could be imaged.In vivo images rendered very fine anatomic details such as fascicles of the median nerve and the branching of the nerve bundles. High-resolution images of cartilage, labrum, and tendons could be acquired. Additionally, turbo spin echo (TSE) and inversion recovery sequences performed very well. Conclusions: This study demonstrates that the concept of two four-channel transmit/receive RF arrays can be used as a multipurpose coil for high-resolutionin vivo MR imaging of the musculoskeletal system at 7 T. Not only gradient echo but also typical clinical and SAR-intensive sequences such as STIR and TSE performed well. Imaging of small structures and peripheral nerves could in particular benefit from this technique.}, language = {en} } @article{KraffBitzBreyeretal.2011, author = {Kraff, Oliver and Bitz, Andreas and Breyer, Tobias and Kruszona, Stefan and Maderwald, Stefan and Brote, Irina and Gizewski, Elke R. and Ladd, Mark E. and Quick, Harald H.}, title = {A transmit/receive radiofrequency array for imaging the carotid arteries at 7 Tesla: coil design and first in vivo results}, series = {Investigative Radiology}, volume = {46}, journal = {Investigative Radiology}, number = {4}, publisher = {Wolters Kluwer}, address = {K{\"o}ln}, issn = {1536-0210}, doi = {10.1097/RLI.0b013e318206cee4}, pages = {246 -- 254}, year = {2011}, abstract = {Objective: To develop a transmit/receive radiofrequency (RF) array for magnetic resonance imaging (MRI) of the carotid arteries at 7 T. The prototype is characterized in numerical simulations and bench measurements, and the feasibility of plaque imaging at 7 T is demonstrated in first in vivo images. Materials and Methods: The RF phased array coil consists of 8 surface loop coils. To allow imaging of both sides of the neck, the RF array is divided into 2 coil clusters, each with 4 overlapping loop elements. For safety validation, numerical computations of the RF field distribution and the corresponding specific absorption rate were performed on the basis of a heterogeneous human body model. To validate the coil model, maps of the transmit B1+ field were compared between simulation and measurement. In vivo images of a healthy volunteer and a patient (ulcerating plaque and a 50\% stenosis of the right internal carotid artery) were acquired using a 3-dimensional FLASH sequence with a high isotropic spatial resolution of 0.54 mm as well as using pulse-triggered proton density (PD)/T2-weighted turbo spin echo sequences. Results: Measurements of the S-parameters yielded a reflection and isolation of the coil elements of better than -18 and -13 dB, respectively. Measurements of the g-factor indicated good image quality for parallel imaging acceleration factors up to 2.4. A similar distribution and a very good match of the absolute values were found between the measured and simulated B1+ transmit RF field for the validation of the coil model. In vivo images revealed good signal excitation of both sides of the neck and a high vessel-to-background image contrast for the noncontrast-enhanced 3-dimensional FLASH sequence. Imaging at 7 T could depict the extent of stenosis, and revealed the disruption and ulcer of the plaque. Conclusions: This study demonstrates that 2 four-channel transmit/receive RF arrays for each side of the neck is a suitable concept for in vivo MRI of the carotid arteries at 7 Tesla. Further studies are needed to explore and exploit the full potential of 7 T high-field MRI for carotid atherosclerotic plaque imaging.}, language = {en} } @article{KowalewskiBragardHueningetal.2023, author = {Kowalewski, Paul and Bragard, Michael and H{\"u}ning, Felix and De Doncker, Rik W.}, title = {An inexpensive Wiegand-sensor-based rotary encoder without rotating magnets for use in electrical drives}, series = {IEEE Transactions on Instrumentation and Measurement}, journal = {IEEE Transactions on Instrumentation and Measurement}, publisher = {IEEE}, issn = {0018-9456 (Print)}, doi = {10.1109/TIM.2023.3326166}, pages = {10 Seiten}, year = {2023}, abstract = {This paper introduces an inexpensive Wiegand-sensor-based rotary encoder that avoids rotating magnets and is suitable for electrical-drive applications. So far, Wiegand-sensor-based encoders usually include a magnetic pole wheel with rotating permanent magnets. These encoders combine the disadvantages of an increased magnet demand and a limited maximal speed due to the centripetal force acting on the rotating magnets. The proposed approach reduces the total demand of permanent magnets drastically. Moreover, the rotating part is manufacturable from a single piece of steel, which makes it very robust and cheap. This work presents the theoretical operating principle of the proposed approach and validates its benefits on a hardware prototype. The presented proof-of-concept prototype achieves a mechanical resolution of 4.5 ° by using only 4 permanent magnets, 2Wiegand sensors and a rotating steel gear wheel with 20 teeth.}, language = {en} } @article{KobusBitzUdenetal.2012, author = {Kobus, Thiele and Bitz, Andreas and Uden, Mark J. van and Lagemaat, Miram W. and Rothgang, Eva and Orzada, Stephan and Heerschap, Arend and Scheenen, Tom W. J.}, title = {In vivo 31P MR spectroscopic imaging of the human prostate at 7 T: safety and feasibility}, series = {Magnetic Resonance in Medicine}, volume = {68}, journal = {Magnetic Resonance in Medicine}, number = {6}, publisher = {Wiley-Liss}, address = {New York}, issn = {1522-2594}, doi = {10.1002/mrm.24175}, pages = {1683 -- 1695}, year = {2012}, abstract = {31P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D 31P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a 31P endorectal coil was developed and combined with an eight-channel 1H body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and Burn:x-wiley:07403194:media:MRM24175:tex2gif-stack-1 measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the 31P endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel 1H array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the 1H array coil was allowed. For transmitting with the 31P endorectal coil, our safety limit of less than 1°C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D 31P MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm3. The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer.}, language = {en} } @article{KlompBitzHeerschapetal.2009, author = {Klomp, D. W. J. and Bitz, Andreas and Heerschap, A. and Scheenen, T. W. J.}, title = {Proton spectroscopic imaging of the human prostate at 7 T}, series = {NMR in Biomedicine}, volume = {22}, journal = {NMR in Biomedicine}, number = {5}, issn = {1099-1492}, doi = {10.1002/nbm.1360}, pages = {495 -- 501}, year = {2009}, language = {en} } @article{KlingeOttoMuehl2015, author = {Klinge, Uwe and Otto, Jens and M{\"u}hl, Thomas}, title = {High Structural Stability of Textile Implants Prevents Pore Collapse and Preserves Effective Porosity at Strain}, series = {BioMed Research International}, volume = {2015}, journal = {BioMed Research International}, issn = {2314-6133 (Print)}, doi = {10.1155/2015/953209}, pages = {7 pages}, year = {2015}, language = {en} } @article{JensKaldenhoffKirschnerHermannsetal.2014, author = {Jens, Otto and Kaldenhoff, E. and Kirschner-Hermanns, R. and M{\"u}hl, Thomas and Klinge, Uwe}, title = {Elongation of textile pelvic floor implants under load is related to complete loss of effective porosity, thereby favoring incorporation in scar plates}, series = {Journal of biomedical materials research. Part A}, volume = {102}, journal = {Journal of biomedical materials research. Part A}, number = {4}, publisher = {Wiley}, address = {New York}, issn = {1552-4965}, doi = {10.1002/jbm.a.34767}, pages = {1079 -- 1084}, year = {2014}, abstract = {Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome.}, language = {en} } @article{HueningWilkeNakielskietal.1997, author = {H{\"u}ning, Felix and Wilke, I. and Nakielski, G. and Kotzler, J.}, title = {Dynamic conductivity of YBCO thin films from low to very high frequencies / Wilke, I. ; Nakielski, G. ; Kotzler, J. ; Subke, K. O. ; Jaekel, C. ; H{\"u}ning, F. ; Roskos, H. G. ; Kurz, Heinrich}, series = {Applied superconductivity 1997 : proceedings of EUCAS 1997, the Third European Conference on Applied Superconductivity, held in the Netherlands, 30 June - 3 July 1997 / ed. by H. Rogalla}, journal = {Applied superconductivity 1997 : proceedings of EUCAS 1997, the Third European Conference on Applied Superconductivity, held in the Netherlands, 30 June - 3 July 1997 / ed. by H. Rogalla}, publisher = {IOP}, address = {Bristol}, isbn = {0-7503-0487-1}, pages = {121 -- 124}, year = {1997}, language = {en} } @article{HueningSpartaRedhammeretal.2001, author = {H{\"u}ning, Felix and Sparta, K. and Redhammer, G. J. and Roussel, P.}, title = {Structural Phase Transition in the 2D Spin Dimer Compound SrCu2(BO3)2 / Sparta, K. ; Redhammer, G. J. ; Roussel, P. ; Heger, G. ; Roth, G. ; Ionescu, A. Lemmens, P. ; Grove, M. ; G{\"u}ntherrodt, G. ; H{\"u}ning, F. ; Lueken, H. ; Kageyama, H. ; Onizuka, K ; Ueda}, series = {The European Physical Journal B - Condensed Matter and Complex Systems. 19 (2001), H. 4}, journal = {The European Physical Journal B - Condensed Matter and Complex Systems. 19 (2001), H. 4}, publisher = {-}, isbn = {1434-6036}, pages = {507 -- 516}, year = {2001}, language = {en} } @article{HueningLukenSchilderetal.2001, author = {H{\"u}ning, Felix and Luken, Heiko and Schilder, Herbert and Eifert, Thomas}, title = {Magnetochemistry: Compounds and Concepts / Lueken, Heiko ; Schilder, Herbert ; Eifert, Thomas ; Handrick, Klaus ; H{\"u}ning, Felix}, series = {Advances in Solid State Physics. 201 (2001)}, journal = {Advances in Solid State Physics. 201 (2001)}, publisher = {-}, pages = {515 -- 532}, year = {2001}, language = {en} } @article{HueningLeineweberJacobsetal.1999, author = {H{\"u}ning, Felix and Leineweber, A. and Jacobs, H. and Lueken, H.}, title = {ε-Fe3N: magnetic structure, magnetization and temperature dependent disorder of nitrogen / Leineweber, A. ; Jacobs, H. ; H{\"u}ning, F. ; Lueken, H. ; Schilder, H. ; Kockelmann, W.}, series = {Journal of Alloys and Compounds. 288 (1999), H. 1-2}, volume = {288}, journal = {Journal of Alloys and Compounds. 288 (1999), H. 1-2}, number = {1-2}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {1873-4669}, pages = {79 -- 87}, year = {1999}, abstract = {ε-Fe3N has been investigated by time-of-flight neutron diffraction (temperature range 4.2-618 K) and SQUID magnetometry (2-700 K, B≤5 T). A ferromagnetic spin structure is observed with magnetic moments oriented perpendicular to the c-axis of the hexagonal nuclear structure. The magnetic saturation moment of iron is 2.2 μB at 4.2 K from neutron diffraction and 2.0 μB from magnetic measurements and decreases in a Brillouin-like manner on heating to TC=575 K. Above 450 K an increasing but reversible disorder of the nitrogen partial structure is observed.}, language = {en} } @article{HueningLeineweberJacobsetal.2001, author = {H{\"u}ning, Felix and Leineweber, A. and Jacobs, H. and Lueken, H.}, title = {Nitrogen Ordering and ferromagnetic properties of -Fe3N1+x (0.10  x  0.39) and -Fe3(N0.80C0.20)1.38 / Leineweber, A. ; Jacobs, H. ; H{\"u}ning, F. ; Lueken, H. ; Kockelmann, W.}, series = {Journal of Alloys and Compounds. 316 (2001), H. 1-2}, journal = {Journal of Alloys and Compounds. 316 (2001), H. 1-2}, publisher = {-}, isbn = {1873-4669}, pages = {21 -- 38}, year = {2001}, language = {en} }