@article{BronderJessingPoghossianetal.2018, author = {Bronder, Thomas and Jessing, Max P. and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Detection of PCR-Amplified Tuberculosis DNA Fragments with Polyelectrolyte-Modified Field-Effect Sensors}, series = {Analytical Chemistry}, volume = {90}, journal = {Analytical Chemistry}, number = {12}, publisher = {ACS Publications}, address = {Washington, DC}, issn = {0003-2700}, doi = {10.1021/acs.analchem.8b01807}, pages = {7747 -- 7753}, year = {2018}, abstract = {Field-effect-based electrolyte-insulator-semiconductor (EIS) sensors were modified with a bilayer of positively charged weak polyelectrolyte (poly(allylamine hydrochloride) (PAH)) and probe single-stranded DNA (ssDNA) and are used for the detection of complementary single-stranded target DNA (cDNA) in different test solutions. The sensing mechanism is based on the detection of the intrinsic molecular charge of target cDNA molecules after the hybridization event between cDNA and immobilized probe ssDNA. The test solutions contain synthetic cDNA oligonucleotides (with a sequence of tuberculosis mycobacteria genome) or PCR-amplified DNA (which origins from a template DNA strand that has been extracted from Mycobacterium avium paratuberculosis-spiked human sputum samples), respectively. Sensor responses up to 41 mV have been measured for the test solutions with DNA, while only small signals of ∼5 mV were detected for solutions without DNA. The lower detection limit of the EIS sensors was ∼0.3 nM, and the sensitivity was ∼7.2 mV/decade. Fluorescence experiments using SybrGreen I fluorescence dye support the electrochemical results.}, language = {en} } @incollection{GollandBaumHammingeretal.2018, author = {Golland, Alexander and Baum, Michael and Hamminger, Alexander and Olbertz, Klaus}, title = {Ein {\"U}berblick: Umsetzung der Datenschutz-Grundverordnung}, series = {Das neue Datenschutzrecht in der Praxis des Steuerberaters Beitragssammlung}, booktitle = {Das neue Datenschutzrecht in der Praxis des Steuerberaters Beitragssammlung}, publisher = {NWB Verlag}, address = {Herne}, isbn = {978-3-482-67271-2}, pages = {8 -- 14}, year = {2018}, abstract = {Datenschutz und der 25.5.2018, wie ein Damoklesschwert scheinen beide Begriffe zurzeit im Raum zu stehe. Jeder weiß oder sollte zumindest um das Inkrafttreten der europ{\"a}ischen DSGVO am 25.5.2018 wissen. Viel wurde {\"u}ber wesentliche Neuerungen im Datenschutzrecht berichtet. Nicht zuletzt {\"u}ber gesteigerte organisatorische Anforderungen, Dokumentationspflichten und drohende Bußgelder. Doch was bedeuten diese Neuerungen ganz konkret f{\"u}r die Praxis des Steuerberaters? Anders als man vermuten k{\"o}nnte, werden die datenschutzrechtlichen Neuerungen nicht nur im Bereich der Kanzleiorganisation relevant. Auch im Steuerverwaltungsverfahren sieht sich der Steuerberater datenschutzrechtlichen Fragestellungen gegen{\"u}ber, bspw. dann, wenn die Finanzbeh{\"o}rden bei der Verarbeitung der personenbezogenen Daten des Mandanten gegen die DSGVO verstoßen. Gleiches gilt in Bereichen des Besch{\"a}ftigtendatenschutzes. Sowohl der Kanzleiinhaber selbst, als auch seine Arbeitgeber-Mandanten haben die Vorschriften des Besch{\"a}ftigtendatenschutzes einzuhalten. Der Steuerberater ben{\"o}tigt datenschutzrechtliches Know How, welches unmittelbar seine t{\"a}gliche Praxis betrifft. Andernfalls besteht das Risiko, dass dieser mit mehr Fragen, als Antworten zur{\"u}ck bleibt.}, language = {de} } @article{MolinnusHardtSiegertetal.2018, author = {Molinnus, Denise and Hardt, Gabriel and Siegert, Petra and Willenberg, Holger S. and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Detection of Adrenaline in Blood Plasma as Biomarker for Adrenal Venous Sampling}, series = {Electroanalysis}, volume = {30}, journal = {Electroanalysis}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-4109}, doi = {10.1002/elan.201800026}, pages = {937 -- 942}, year = {2018}, abstract = {An amperometric bi-enzyme biosensor based on substrate recycling principle for the amplification of the sensor signal has been developed for the detection of adrenaline in blood. Adrenaline can be used as biomarker verifying successful adrenal venous sampling procedure. The adrenaline biosensor has been realized via modification of a galvanic oxygen sensor with a bi-enzyme membrane combining a genetically modified laccase and a pyrroloquinoline quinone-dependent glucose dehydrogenase. The measurement conditions such as pH value and temperature were optimized to enhance the sensor performance. A high sensitivity and a low detection limit of about 0.5-1 nM adrenaline have been achieved in phosphate buffer at pH 7.4, relevant for measurements in blood samples. The sensitivity of the biosensor to other catecholamines such as noradrenaline, dopamine and dobutamine has been studied. Finally, the sensor has been successfully applied for the detection of adrenaline in human blood plasma.}, language = {en} } @incollection{SchoeningPoghossian2018, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {Enzyme und Biosensorik}, series = {Einf{\"u}hrung in die Enzymtechnologie}, booktitle = {Einf{\"u}hrung in die Enzymtechnologie}, publisher = {Springer Spektrum}, address = {Berlin}, isbn = {978-3-662-57619-9}, doi = {10.1007/978-3-662-57619-9_18}, pages = {323 -- 347}, year = {2018}, abstract = {Enzymbasierte Biosensoren finden seit mehr als f{\"u}nf Jahrzehnten einen prosperierenden Wachstumsmarkt und werden zunehmend auch in biotechnologischen Prozessen eingesetzt. In diesem Kapitel werden, ausgehend vom Sensorbegriff und typischen Kenngr{\"o}ßen f{\"u}r Biosensoren (Abschn. 18.1), elektrochemische Enzym-Biosensoren vorgestellt und deren typischen Einsatzgebiete diskutiert (Abschn. 18.2). Ein Blick {\"u}ber den „Tellerrand" hinaus zeigt alternative Transduktorprinzipien (Abschn. 18.3) und f{\"u}hrt abschließend in aktuelle Forschungstrends ein (Abschn. 18.4).}, language = {de} } @inproceedings{BlankeDringVonteinetal.2018, author = {Blanke, Tobias and Dring, Bernd and Vontein, Marius and Kuhnhenne, Markus}, title = {Climate Change Mitigation Potentials of Vertical Building Integrated Photovoltaic}, series = {8th International Workshop on Integration of Solar Power into Power Systems : 16-17 October 2018, Stockholm, Sweden}, booktitle = {8th International Workshop on Integration of Solar Power into Power Systems : 16-17 October 2018, Stockholm, Sweden}, pages = {1 -- 7}, year = {2018}, language = {en} } @article{Golland2018, author = {Golland, Alexander}, title = {Gemeinsame Verantwortlichkeit in mehrstufigen Verarbeitungsszenarien}, volume = {21}, number = {7-8}, publisher = {dfv Mediengruppe}, address = {Frankfurt a.M.}, issn = {1434-6354}, pages = {433 -- 438}, year = {2018}, abstract = {Die Rechtsfigur der gemeinsamen Verantwortlichkeit besch{\"a}ftigt die datenschutzrechtliche Literatur seit Langem. Die Bestimmung der Verantwortlichkeit bei arbeitsteiligen Verarbeitungsverfahren, welche vor allem bei heutigen Plattformdiensten {\"u}blich sind, ist komplex: Stets sind mehrere Akteure beteiligt und in der Regel werden durch die Handlung eines Beteiligten mehrere Verarbeitungsschritte ausgel{\"o}st. Nun hat sich der EuGH in einem in mehrfacher Hinsicht bemerkenswerten Urteil ge{\"a}ußert.}, language = {de} } @article{PoghossianJablonskiKochetal.2018, author = {Poghossian, Arshak and Jablonski, Melanie and Koch, Claudia and Bronder, Thomas and Rolka, David and Wege, Christina and Sch{\"o}ning, Michael Josef}, title = {Field-effect biosensor using virus particles as scaffolds for enzyme immobilization}, series = {Biosensors and Bioelectronics}, volume = {110}, journal = {Biosensors and Bioelectronics}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0956-5663}, doi = {10.1016/j.bios.2018.03.036}, pages = {168 -- 174}, year = {2018}, abstract = {A field-effect biosensor employing tobacco mosaic virus (TMV) particles as scaffolds for enzyme immobilization is presented. Nanotubular TMV scaffolds allow a dense immobilization of precisely positioned enzymes with retained activity. To demonstrate feasibility of this new strategy, a penicillin sensor has been developed by coupling a penicillinase with virus particles as a model system. The developed field-effect penicillin biosensor consists of an Al-p-Si-SiO₂-Ta₂O₅-TMV structure and has been electrochemically characterized in buffer solutions containing different concentrations of penicillin G. In addition, the morphology of the biosensor surface with virus particles was characterized by scanning electron microscopy and atomic force microscopy methods. The sensors possessed a high penicillin sensitivity of ~ 92 mV/dec in a nearly-linear range from 0.1 mM to 10 mM, and a low detection limit of about 50 µM. The long-term stability of the penicillin biosensor was periodically tested over a time period of about one year without any significant loss of sensitivity. The biosensor has also been successfully applied for penicillin detection in bovine milk samples.}, language = {en} } @inproceedings{HarzheimHeuermann2018, author = {Harzheim, Thomas and Heuermann, Holger}, title = {Phase Repeatable Synthesizers as a New Harmonic Phase Standard for Nonlinear Network Analysis}, series = {IEEE Transactions on Microwave Theory and Techniques}, booktitle = {IEEE Transactions on Microwave Theory and Techniques}, publisher = {IEEE}, doi = {10.1109/TMTT.2018.2817513}, pages = {1 -- 8}, year = {2018}, language = {en} } @article{Golland2018, author = {Golland, Alexander}, title = {Umsetzung der Datenschutz-Grundverordnung - Neue Herausforderungen f{\"u}r Unternehmen}, series = {NWB Rechnungswesen - BBK}, journal = {NWB Rechnungswesen - BBK}, number = {1}, isbn = {0340-9848}, pages = {35 -- 39}, year = {2018}, abstract = {Nach einem intensiven politischen Diskurs wurde im vergangenen Jahr die Datenschutz-Grundverordnung (DSGVO) verabschiedet. Die DSGVO ersetzt zum 25.5.2018 die bislang geltende, aus dem Jahre 1995 stammende Datenschutz-Richtlinie 95/46/EG. Die Novellierung des Datenschutzrechts bringt zahlreiche neue Anforderungen mit sich. Unternehmen sind daher gezwungen, sich auf die {\"A}nderungen einzustellen, ihre datenschutzrelevanten Prozesse im Hinblick auf die neuen Anforderungen zu {\"u}berpr{\"u}fen und bis zum Mai 2018 an der DSGVO auszurichten. Der Beitrag gibt einen kurzen {\"U}berblick {\"u}ber die zentralen Aspekte der Datenschutzreform und die damit einhergehenden Herausforderungen f{\"u}r Unternehmen.}, language = {de} } @article{RabehiGarlanAchtsnichtetal.2018, author = {Rabehi, Amine and Garlan, Benjamin and Achtsnicht, Stefan and Krause, Hans-Joachim and Offenh{\"a}usser, Andreas and Ngo, Kieu and Neveu, Sophie and Graff-Dubois, Stephanie and Kokabi, Hamid}, title = {Magnetic detection structure for Lab-on-Chip applications based on the frequency mixing technique}, series = {Sensors}, volume = {18}, journal = {Sensors}, number = {6}, publisher = {MDPI}, address = {Basel}, issn = {1424-8220}, doi = {10.3390/s18061747}, pages = {14 Seiten}, year = {2018}, abstract = {A magnetic frequency mixing technique with a set of miniaturized planar coils was investigated for use with a completely integrated Lab-on-Chip (LoC) pathogen sensing system. The system allows the detection and quantification of superparamagnetic beads. Additionally, in terms of magnetic nanoparticle characterization ability, the system can be used for immunoassays using the beads as markers. Analytical calculations and simulations for both excitation and pick-up coils are presented; the goal was to investigate the miniaturization of simple and cost-effective planar spiral coils. Following these calculations, a Printed Circuit Board (PCB) prototype was designed, manufactured, and tested for limit of detection, linear response, and validation of theoretical concepts. Using the magnetic frequency mixing technique, a limit of detection of 15 µg/mL of 20 nm core-sized nanoparticles was achieved without any shielding.}, language = {en} }