@article{ButenwegMarinkovićKubalskietal.2018, author = {Butenweg, Christoph and Marinković, Marko and Kubalski, Thomas and Fehling, Ekkehard and Pfetzing, Thomas and Meyer, Udo}, title = {Auslegung von Stahlbetonrahmentragwerken mit Ausfachungen aus Ziegelmauerwerk (Teil 2)}, series = {Ziegelindustrie international : ZI = Brick and tile industry international}, journal = {Ziegelindustrie international : ZI = Brick and tile industry international}, number = {6}, editor = {Voss, Michael}, publisher = {Bauverlag BV GmbH}, address = {G{\"u}tersloh}, issn = {0341-0552}, pages = {24 -- 43}, year = {2018}, abstract = {Im Rahmen des europ{\"a}ischen Verbundprojekts INSYSME wurden von den deutschen Partnern die Systeme IMES und INODIS zur Verbesserung des seismischen Verhaltens von ausgefachten Stahlbetonrahmen entwickelt. Ziel beider Systeme ist es, Stahlbetonrahmen und Ausfachung zu entkoppeln, anstatt die Tragf{\"a}higkeit durch aufwendige und kostspielige zus{\"a}tzliche Bewehrungseinlagen zu erh{\"o}hen. Erste Ergebnisse des Systems IMES f{\"u}r Belastungen in und senkrecht zu der Wandebene werden vorgestellt.}, language = {de} } @inproceedings{GorzalkaDahlkeGoettscheetal.2018, author = {Gorzalka, Philip and Dahlke, Dennis and G{\"o}ttsche, Joachim and Israel, Martin and Patel, Dhruvkumar and Prahl, Christoph and Schmiedt, Jacob Estevam and Frommholz, Dirk and Hoffschmidt, Bernhard and Linkiewicz, Magdalena}, title = {Building Tomograph-From Remote Sensing Data of Existing Buildings to Building Energy Simulation Input}, series = {EBC, Annex 71, Fifth expert meeting, October 17-19, 2018, Innsbruck, Austria}, booktitle = {EBC, Annex 71, Fifth expert meeting, October 17-19, 2018, Innsbruck, Austria}, pages = {17 Seiten}, year = {2018}, language = {en} } @incollection{Fabo2018, author = {Fabo, Sabine}, title = {Einspr{\"u}che gegen den informierten Himmel ; Wegsehen; Distanzschaffen, Spielen}, series = {Orbitale Irritationen / Herausgeber: REMOTEWORDS: Achim Mohn{\´e} \& Uta Kopp}, booktitle = {Orbitale Irritationen / Herausgeber: REMOTEWORDS: Achim Mohn{\´e} \& Uta Kopp}, publisher = {Herbert von Halem Verlag}, address = {K{\"o}ln}, isbn = {978-3-86962-302-3}, pages = {20 -- 45}, year = {2018}, language = {de} } @article{Wollert2018, author = {Wollert, J{\"o}rg}, title = {TSN - Schluss mit dem Feldbuskrieg?}, series = {Design \& Elektronik}, journal = {Design \& Elektronik}, number = {3}, publisher = {WEKA-Fachmedien}, address = {M{\"u}nchen}, issn = {0933-8667}, pages = {26 -- 31}, year = {2018}, language = {de} } @book{Timme2018, author = {Timme, Michael}, title = {BGB Crashkurs: der sichere Weg durch die Pr{\"u}fung}, edition = {5. Auflage}, publisher = {C.H. Beck}, address = {M{\"u}nchen}, isbn = {978-3-406-72251-6}, pages = {160 Seiten}, year = {2018}, language = {de} } @article{WeldenSchejaSchoeningetal.2018, author = {Welden, Rene and Scheja, Sabrina and Sch{\"o}ning, Michael Josef and Wagner, Patrick and Wagner, Torsten}, title = {Electrochemical Evaluation of Light-Addressable Electrodes Based on TiO2 for the Integration in Lab-on-Chip Systems}, series = {physica status solidi a : applications and materials sciences}, volume = {215}, journal = {physica status solidi a : applications and materials sciences}, number = {15}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201800150}, pages = {Article number 1800150}, year = {2018}, abstract = {In lab-on-chip systems, electrodes are important for the manipulation (e.g., cell stimulation, electrolysis) within such systems. An alternative to commonly used electrode structures can be a light-addressable electrode. Here, due to the photoelectric effect, the conducting area can be adjusted by modification of the illumination area which enables a flexible control of the electrode. In this work, titanium dioxide based light-addressable electrodes are fabricated by a sol-gel technique and a spin-coating process, to deposit a thin film on a fluorine-doped tin oxide glass. To characterize the fabricated electrodes, the thickness, and morphological structure are measured by a profilometer and a scanning electron microscope. For the electrochemical behavior, the dark current and the photocurrent are determined for various film thicknesses. For the spatial resolution behavior, the dependency of the photocurrent while changing the area of the illuminated area is studied. Furthermore, the addressing of single fluid compartments in a three-chamber system, which is added to the electrode, is demonstrated.}, language = {en} } @article{MichauxMatternKallweit2018, author = {Michaux, F. and Mattern, P. and Kallweit, Stephan}, title = {RoboPIV: how robotics enable PIV on a large industrial scale}, series = {Measurement Science and Technology}, volume = {29}, journal = {Measurement Science and Technology}, number = {7}, publisher = {IOP}, address = {Bristol}, issn = {1361-6501}, doi = {10.1088/1361-6501/aab5c1}, pages = {074009}, year = {2018}, abstract = {This work demonstrates how the interaction between particle image velocimetry (PIV) and robotics can massively increase measurement efficiency. The interdisciplinary approach is shown using the complex example of an automated, large scale, industrial environment: a typical automotive wind tunnel application. Both the high degree of flexibility in choosing the measurement region and the complete automation of stereo PIV measurements are presented. The setup consists of a combination of three robots, individually used as a 6D traversing unit for the laser illumination system as well as for each of the two cameras. Synchronised movements in the same reference frame are realised through a master-slave setup with a single interface to the user. By integrating the interface into the standard wind tunnel management system, a single measurement plane or a predefined sequence of several planes can be requested through a single trigger event, providing the resulting vector fields within minutes. In this paper, a brief overview on the demands of large scale industrial PIV and the existing solutions is given. Afterwards, the concept of RoboPIV is introduced as a new approach. In a first step, the usability of a selection of commercially available robot arms is analysed. The challenges of pose uncertainty and importance of absolute accuracy are demonstrated through comparative measurements, explaining the individual pros and cons of the analysed systems. Subsequently, the advantage of integrating RoboPIV directly into the existing wind tunnel management system is shown on basis of a typical measurement sequence. In a final step, a practical measurement procedure, including post-processing, is given by using real data and results. Ultimately, the benefits of high automation are demonstrated, leading to a drastic reduction in necessary measurement time compared to non-automated systems, thus massively increasing the efficiency of PIV measurements.}, language = {en} } @inproceedings{SchulzeMuehleisenFeyerl2018, author = {Schulze, Sven and M{\"u}hleisen, M. and Feyerl, G{\"u}nter}, title = {Adaptive energy management strategy for a heavy-duty truck with a P2-hybrid topology}, series = {18. Internationales Stuttgarter Symposium. Proceedings}, booktitle = {18. Internationales Stuttgarter Symposium. Proceedings}, publisher = {Springer Vieweg}, address = {Wiesbaden}, doi = {10.1007/978-3-658-21194-3}, pages = {75 -- 89}, year = {2018}, language = {en} } @article{JildehOberlaenderKirchneretal.2018, author = {Jildeh, Zaid B. and Oberl{\"a}nder, Jan and Kirchner, Patrick and Wagner, Patrick H. and Sch{\"o}ning, Michael Josef}, title = {Thermocatalytic Behavior of Manganese (IV) Oxide as Nanoporous Material on the Dissociation of a Gas Mixture Containing Hydrogen Peroxide}, series = {Nanomaterials}, volume = {8}, journal = {Nanomaterials}, number = {4}, publisher = {MDPI}, address = {Basel}, issn = {2079-4991}, doi = {10.3390/nano8040262}, pages = {Artikel 262}, year = {2018}, abstract = {In this article, we present an overview on the thermocatalytic reaction of hydrogen peroxide (H₂O₂) gas on a manganese (IV) oxide (MnO₂) catalytic structure. The principle of operation and manufacturing techniques are introduced for a calorimetric H₂O₂ gas sensor based on porous MnO₂. Results from surface analyses by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) of the catalytic material provide indication of the H₂O₂ dissociation reaction schemes. The correlation between theory and the experiments is documented in numerical models of the catalytic reaction. The aim of the numerical models is to provide further information on the reaction kinetics and performance enhancement of the porous MnO₂ catalyst.}, language = {en} } @article{JildehOberlaenderKirchneretal.2018, author = {Jildeh, Zaid B. and Oberl{\"a}nder, Jan and Kirchner, Patrick and Keusgen, Michael and Wagner, Patrick H. and Sch{\"o}ning, Michael Josef}, title = {Experimental and Numerical Analyzes of a Sensor Based on Interdigitated Electrodes for Studying Microbiological Alterations}, series = {physica status solidi (a): applications and materials science}, volume = {215}, journal = {physica status solidi (a): applications and materials science}, number = {15}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201700920}, pages = {Artikel 1700920}, year = {2018}, abstract = {In this work, a cell-based biosensor to evaluate the sterilization efficacy of hydrogen peroxide vapor sterilization processes is characterized. The transducer of the biosensor is based on interdigitated gold electrodes fabricated on an inert glass substrate. Impedance spectroscopy is applied to evaluate the sensor behavior and the alteration of test microorganisms due to the sterilization process. These alterations are related to changes in relative permittivity and electrical conductivity of the bacterial spores. Sensor measurements are conducted with and without bacterial spores (Bacillus atrophaeus), as well as after an industrial sterilization protocol. Equivalent two-dimensional numerical models based on finite element method of the periodic finger structures of the interdigitated gold electrodes are designed and validated using COMSOL® Multiphysics software by the application of known dielectric properties. The validated models are used to compute the electrical properties at different sensor states (blank, loaded with spores, and after sterilization). As a final result, we will derive and tabulate the frequency-dependent electrical parameters of the spore layer using a novel model that combines experimental data with numerical optimization techniques.}, language = {en} }