@inproceedings{NixFrotscherStaat2012, author = {Nix, Yvonne and Frotscher, Ralf and Staat, Manfred}, title = {Implementation of the edge-based smoothed extended finite element method}, series = {Proceedings 6th European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Vienna, Austria, September 10-14, 2012}, booktitle = {Proceedings 6th European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Vienna, Austria, September 10-14, 2012}, editor = {Eberhardsteiner, J.}, year = {2012}, language = {en} } @misc{TkachenkovonKnobelsdorffBrenkenhoffKleindienstetal.2012, author = {Tkachenko, Valeriy and von Knobelsdorff-Brenkenhoff, Florian and Kleindienst, Denise and Winter, Lukas and Rieger, Jan and Frauenrath, Tobias and Dieringer, Matthias A. and Santoro, Davide and Niendorf, Thoralf and Schulz-Menger, Jeanette}, title = {Cardiovasular MR at 7Tesla: assessment of the right ventricle}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {The assessment of the right ventricle (RV) is a challenge in today's cardiology, but of growing clinical impact regarding patient prognosis in different cardiac diseases. The detection and differentiation of small wall motion abnormalities may help to enhance the differentiation of cardiomyopathies including Arrhythmogenic Rightventricular Cardiomyopathy. Cardiovascular magnetic resonance (CMR) at 1.5T is the accepted gold standard for RV quantification. The higher spatial resolution achievable at ultrahigh field strength (UHF) offers the potential to gain new insights into the structure and function of the RV. To approach this goal accurate RV chamber quantification at 7T has to be proven. Consequently this study examines the feasibility of assessment of RV dimensions and function at 7T using improved spatial resolution enabled by the intrinsic sensitivity gain of UHF CMR. For this purpose, a dedicated 16 channel TX/RX RF coil array is used together with 2D CINE fast gradient echo (FGRE) imaging. For comparison RV chamber quantification is conducted at 1.5T using a SSFP based state of the art clinical protocol.}, language = {en} } @misc{TippkoetterUlber2012, author = {Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Rezension zu: Encyclopedia of Industrial Biotechnology, Vol. 1-7. By MC Flickinger.}, series = {Chemie Ingenieur Technik}, volume = {6}, journal = {Chemie Ingenieur Technik}, number = {84}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201290052}, pages = {936}, year = {2012}, language = {en} } @inproceedings{SchoppNachtrodtHeuermannetal.2012, author = {Schopp, Christoph and Nachtrodt, Frederik and Heuermann, Holger and Scherer, Ulrich W. and Mostacci, Domiziano and Finger, Torsten and Tietsch, Wolfgang}, title = {A novel 2.45 GHz/200 W Microwave Plasma Jet for High Temperature Applications above 3600 K}, series = {Journal of Physics : Conference Series}, volume = {406}, booktitle = {Journal of Physics : Conference Series}, number = {012029}, issn = {1742-6596}, pages = {5}, year = {2012}, language = {en} } @misc{DuweTippkoetterLeipoldetal.2012, author = {Duwe, A. and Tippk{\"o}tter, Nils and Leipold, D. and Riemer, S. and Zorn, H. and Ulber, Roland}, title = {Holzhydrolyse als Feststoffreaktion: Charakterisierung von Inhibitoren und Erh{\"o}hung der Ausbeute durch den Einsatz lignolytischer Enzyme}, series = {Chemie Ingenieur Technik}, volume = {84}, journal = {Chemie Ingenieur Technik}, number = {8}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201250298}, pages = {1307}, year = {2012}, abstract = {Der Erhalt m{\"o}glichst hoher Zuckerkonzentrationen f{\"u}r nachfolgende Fermentationen und eine Steigerung der Produktivit{\"a}t sind Ziele der Hydrolyse bei hohen Feststoffkonzentrationen im Rahmen des Projekts „Lignocellulose Bioraffinerie". Verwendet wird durch ein Organosolv-Verfahren aufgeschlossenes Buchenholz. Die Hydrolyse des Faserstoffes erfolgt mithilfe von CTec2-Enzymen (Fa. Novozymes). Zurzeit k{\"o}nnen unter Einsatz eines neuen Feststoffreaktors Cellulosefasern in einer Konzentration bis 400 g L⁻¹ enzymatisch hydrolysiert werden. Dabei werden Ausbeuten (g Glucose/g Cellulose im Faserstoff) bis 0,86 g g⁻¹ und Glucosekonzentrationenvon 120 g L⁻¹ erreicht. Ein Nachteil ist jedoch die hierbei auftretende Abnahme der Hydrolyseausbeuten. Zahlreiche Limitierungen bez{\"u}glich der Hydrolysierbarkeit von Lignocellulose werden zurzeit diskutiert und publiziert. Ziel der Untersuchungen ist die Identifizierung hydrolysehemmender Substanzen sowie die Erh{\"o}hung der Ausbeute an Zuckermonomeren durch den Einsatz lignolytischer Enzyme. Hierbei wird eine HPLC-MS-Methode zur Charakterisierung hemmender Substanzen eingesetzt, um potenzielle Inhibitoren zu erfassen.}, language = {de} } @misc{WiesenTippkoetterDuweetal.2012, author = {Wiesen, S. and Tippk{\"o}tter, Nils and Duwe, A. and Ulber, Roland}, title = {Aceton-Butanol-Ethanol (ABE)-Fermentation von Organosolv-Holzhydrolysaten}, series = {Chemie Ingenieur Technik}, volume = {84}, journal = {Chemie Ingenieur Technik}, number = {8}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201250262}, pages = {1308}, year = {2012}, abstract = {Die L{\"o}sungsmittelherstellung durch Clostridien konnte wirtschaftlich nicht mit der chemischen Synthese von L{\"o}sungsmitteln auf Erd{\"o}lbasis konkurrieren und wurde in den fr{\"u}hen 1960er Jahren nahezu vollst{\"a}ndig eingestellt. Das Interesse an nachwachsenden Rohstoffen hat in den letzten Jahren zu einem Wiederaufleben der ABE-Fermentation gef{\"u}hrt. Aufgrund seiner h{\"o}heren Energiedichte im Vergleich zu Ethanol ist Biobutanol als Energietr{\"a}gerbesonders interessant und bietet sich z. B. als Produkt einer Bioraffinerie der 2. Generation an. F{\"u}r die beschriebenen Experimente wird durch das Organosolv-Verfahren aufgeschlossenes Buchenholz verwendet. Der Faserstoff wird mithilfe von CTec2-Enzymen hydrolysiert, wobei der erhaltene {\"U}berstand eine Glucosekonzentration von 66 g L⁻¹ aufweist. Auf der Basis dieses Materials k{\"o}nnen mit Clostridium acetobutylicum Butanol-Ausbeuten erzielt werden, die mit denen unter Verwendung von reinen Zuckern vergleichbar sind. Dem Problem der hohen Produktinhibierung wird mit einer In-situ-Produktaufarbeitung begegnet. Mithilfe von L{\"o}sungsmittelimpr{\"a}gnierten Partikeln (SIPs) kann die Produktausbeute drastisch gesteigert werden, indem die gebildeten L{\"o}sungsmittel durch das auf dem Partikel impr{\"a}gnierte L{\"o}sungsmittel w{\"a}hrend der Fermentation extrahiert werden. Zudem wird hierdurch die weitere Produktaufarbeitungstark vereinfacht.}, language = {de} } @inproceedings{PhamNguyenStaat2012, author = {Pham, Phu Tinh and Nguyen, Thanh Ngoc and Staat, Manfred}, title = {FEM based shakedown analysis of hardening structures}, series = {Proceedings International Conference on Advances in Computational Mechanics (ACOME)}, booktitle = {Proceedings International Conference on Advances in Computational Mechanics (ACOME)}, pages = {870 -- 882}, year = {2012}, language = {en} } @incollection{Laack2012, author = {Laack, Walter van}, title = {Elektro- und Ultraschalltherapie}, series = {Leitfaden Naturheilverfahren : f{\"u}r die {\"a}rztliche Praxis}, booktitle = {Leitfaden Naturheilverfahren : f{\"u}r die {\"a}rztliche Praxis}, editor = {Beer, Andr{\´e}-Michael and Adler, Martin}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {978-3-437-56103-0}, doi = {10.1016/B978-3-437-56103-0.10013-5}, pages = {285 -- 299}, year = {2012}, language = {de} } @article{Staat2012, author = {Staat, Manfred}, title = {Limit and shakedown analysis under uncertainty}, series = {Tap chi Khoa hoc \& ung dung - Dai hoc Ton Duc Thang}, volume = {19}, journal = {Tap chi Khoa hoc \& ung dung - Dai hoc Ton Duc Thang}, pages = {45 -- 47}, year = {2012}, language = {en} } @book{FaboKurz2012, author = {Fabo, Sabine and Kurz, Melanie}, title = {Vielen Dank f{\"u}r Ihren Einkauf: Konsumkultur aus Sicht von Design, Kunst und Medien / Sabine Fabo, Melanie Kurz (Hg.)}, publisher = {transcript}, address = {Bielefeld}, isbn = {978-3-8394-2170-3}, doi = {10.14361/transcript.9783839421703}, pages = {184 Seiten ; Illustrationen, Diagramme}, year = {2012}, abstract = {Auch mit der j{\"u}ngsten Finanzkrise hat die Konsumkultur nichts von ihrer Bedeutung als massenkulturelles Ph{\"a}nomen eingeb{\"u}ßt. Im Gegenteil: Das aktuelle Krisenbewusstsein sucht Halt im Konsum, der seinen Verfechtern noch immer als Modell demokratischer Teilhabe an gesellschaftlicher Produktion gilt. Zugleich ist die Konsumkritik der 1960er Jahre in Richtung eines intelligenten und nachhaltigen Konsums weitergef{\"u}hrt worden, und selbstbewusste Konsumenten treten nun als emanzipierte »Prosumer« und Mitakteure des Marktes auf. Das Buch entwickelt aus Sicht von Design, Kunst, Soziologie, Marketing und Medien neue Perspektiven auf das Ph{\"a}nomen Konsum.}, language = {de} } @book{Laack2012, author = {Laack, Walter van}, title = {Schnittstelle Tod: Warum auf ein Danach vertrauen?}, publisher = {Books on Demand}, address = {Norderstedt}, isbn = {978-3-936624-14-4}, pages = {120 S. : Ill.,graph. Darst.}, year = {2012}, language = {de} } @article{HuckPoghossianWagneretal.2012, author = {Huck, Christina and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Combined amperometric/field-effect sensor for the detection of dissolved hydrogen}, series = {Sensors and actuators B: Chemical}, volume = {187}, journal = {Sensors and actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2012.10.050}, pages = {168 -- 173}, year = {2012}, abstract = {Real-time and reliable monitoring of the biogas process is crucial for a stable and efficient operation of biogas production in order to avoid digester breakdowns. The concentration of dissolved hydrogen (H₂) represents one of the key parameters for biogas process control. In this work, a one-chip integrated combined amperometric/field-effect sensor for monitoring the dissolved H₂ concentration has been developed for biogas applications. The combination of two different transducer principles might allow a more accurate and reliable measurement of dissolved H₂ as an early warning indicator of digester failures. The feasibility of the approach has been demonstrated by simultaneous amperometric/field-effect measurements of dissolved H₂ concentrations in electrolyte solutions. Both, the amperometric and the field-effect transducer show a linear response behaviour in the H₂ concentration range from 0.1 to 3\% (v/v) with a slope of 198.4 ± 13.7 nA/\% (v/v) and 14.9 ± 0.5 mV/\% (v/v), respectively.}, language = {en} } @misc{TippkoetterStaubSohlingetal.2012, author = {Tippk{\"o}tter, Nils and Staub, C. and Sohling, U. and Ruf, N. and Ulber, Roland}, title = {Adsorptive Aufreinigung von Molkeproteinen}, series = {Chemie Ingenieur Technik}, volume = {84}, journal = {Chemie Ingenieur Technik}, number = {8}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201250395}, pages = {1285}, year = {2012}, abstract = {In der Molkeverarbeitung dominieren Membranfiltrationsverfahren die Prozessf{\"u}hrung. Hierbei werden {\"u}blicherweise Aufkonzentrierungen der Proteine und deren Trennung von dem Milchzucker Lactose durchgef{\"u}hrt. Der Prozess der adsorptiven Aufreinigung soll als kosteng{\"u}nstige Alternative zu den bisher gebr{\"a}uchlichen Verfahren dienen. Weiterhin er{\"o}ffnet sich durch das Verfahren die M{\"o}glichkeit, einzelne Proteinfraktionen w{\"a}hrend der Verarbeitung anzureichern. Als Proteinquellen wurden f{\"u}r die Untersuchungen Modellproteine, L{\"o}sungen aus Molkenproteinisolat, D{\"u}nnmolke und Molkekonzentrat verwendet. Die Eignung zur Proteinbindung wurden an Tonmaterialien, Silicaten und y-Aluminiumoxiden in Pulverform, in Form von Granulaten sowie Extrudaten als auch sph{\"a}rischen Partikeln {\"u}berpr{\"u}ft. Adsorbentien aus Bentonit/Silica und c-Aluminiumoxid k{\"o}nnen sowohl a-Lactalbumin (aLA) als auch b-Lactoglobulin (bLG) binden, wohingegen Materialien aus Siliciumoxid lediglich ein starkes Adsorptionsverhalten gegen{\"u}ber bLG zeigen. Mischmaterialien aus Siliciumoxid und a-Aluminiumoxid zeigen dasselbe Verhalten wie Materialien aus Siliciumoxid, weisen jedoch eine geringere Kapazit{\"a}t auf. Die Materialen wurden hinsichtlich ihres Einsatzes in chromatographischen Verfahren und Batch-Prozessen untersucht und ein Prozessentwurf f{\"u}r einen zweistufigen Batch-Prozess im R{\"u}hrkessel erarbeitet.}, language = {de} } @incollection{BeckerKnackstedtEggertetal.2012, author = {Becker, J{\"o}rg and Knackstedt, Ralf and Eggert, Mathias and Fleischer, Stefan}, title = {Fachkonzeptionelle Modellierung von Berichtspflichten in Finanzaufsicht und Verwaltung mit dem H2-Toolset}, series = {Auf dem Weg zu einer offenen, smarten und vernetzten Verwaltungskultur}, booktitle = {Auf dem Weg zu einer offenen, smarten und vernetzten Verwaltungskultur}, publisher = {Gesellschaft f{\"u}r Informatik}, address = {Bonn}, isbn = {978-3-88579-291-8}, pages = {83 -- 94}, year = {2012}, language = {de} } @inproceedings{PoghossianAbouzarSchoening2012, author = {Poghossian, Arshak and Abouzar, Maryam H. and Sch{\"o}ning, Michael Josef}, title = {(Bio-­)chemical sensor array based on nanoplate SOI capacitors}, series = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, booktitle = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, editor = {Abdelghani, Adnane and Sch{\"o}ning, Michael Josef}, pages = {31 -- 31}, year = {2012}, language = {en} } @inproceedings{FuchsRitzStrauch2012, author = {Fuchs, Britta and Ritz, Thomas and Strauch, Jakob}, title = {Usability of mobile applications : dissemination of usability engineering in small and medium enterprises}, series = {Proceedings of the International Conference on Data Communication Networking, e-Business and Optical Communication Systems : Rome, Italy, 24 - 27 July, 2012 ; [integrated in the ICETE (International Conference on e-Business and Telecommunications)]}, booktitle = {Proceedings of the International Conference on Data Communication Networking, e-Business and Optical Communication Systems : Rome, Italy, 24 - 27 July, 2012 ; [integrated in the ICETE (International Conference on e-Business and Telecommunications)]}, editor = {Obaidat, Mohammad S.}, publisher = {SciTePress}, address = {[Lissabon]}, isbn = {978-989-8565-23-5}, pages = {272 -- 277}, year = {2012}, language = {en} } @inproceedings{SchusserLeinhosPoghossianetal.2012, author = {Schusser, Sebastian and Leinhos, Marcel and Poghossian, Arshak and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Biopolymer-degradation monitoring by chip-­based impedance spectroscopy technique}, series = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, booktitle = {Nanoscale Science and Technology (NS\&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012}, editor = {Abdelghani, Adnane and Sch{\"o}ning, Michael Josef}, pages = {47 -- 47}, year = {2012}, language = {en} } @book{DigelZhubanovaAkimbekov2012, author = {Digel, Ilya and Zhubanova, Azhar Ahmetovna and Akimbekov, Nuraly S.}, title = {Visual Virology}, address = {Almaty}, isbn = {978-601-247-298-1}, pages = {144 S. : zahlr. Ill.}, year = {2012}, language = {en} } @article{Wolf2012, author = {Wolf, Martin R.}, title = {Von Security Awareness zum Secure Behaviour}, series = {Hakin9 Extra - IT-Forensik}, volume = {2012}, journal = {Hakin9 Extra - IT-Forensik}, number = {5}, publisher = {Software Wydawnictwo}, address = {Warszawa}, issn = {1733-7186}, pages = {18 -- 19}, year = {2012}, abstract = {Security Awareness ist derzeit ein viel diskutiertes Thema. Es reicht nicht, einfach nur ein paar technische Systeme (z.B. Firewalls) zu installieren, um ein angemessenes Schutzniveau zu erzielen. Neben einer guten Organisation von IT Security ist es auch notwendig, den Mitarbeiter einzubinden. Der vielzitierte "Faktor Mensch" ist derjenige, der die Technik korrekt anwenden muss und der durch falsches Verhalten technische und organisatorische Schutzmaßnahmen aushebeln kann. Deshalb reicht es nicht aus, wenn sich der Mitarbeiter der Gefahren bewusst ("aware") ist, er muss auch dementsprechend "sicher" handeln.}, language = {de} } @misc{FrauenrathPfeifferHezeletal.2012, author = {Frauenrath, Tobias and Pfeiffer, Harald and Hezel, Fabian and Dieringer, Matthias A. and Winter, Lukas and Gr{\"a}ßl, Andreas and Santoro, Davide and {\"O}zerdem, Celal and Renz, Wolfgang and Greiser, Andreas and Niendorf, Thoralf}, title = {Lessons learned from cardiac MRI at 7.0 T: LV function assessment at 3.0 T using local multi-channel transceiver coil arrays}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {Cardiac MR (CMR) is of proven clinical value but also an area of vigorous ongoing research since image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Recent developments of CMR at 7.0 T have been driven by pioneering explorations into novel multichannel transmit and receive coil array technology to tackle the challenges B1+-field inhomogeneities, to offset specific-absorption rate (SAR) constraints and to reduce banding artifacts in SSFP imaging. For this study, recognition of the benefits and performance of local surface Tx/Rx-array structures recently established at 7.0 T inspired migration to 3.0 T, where RF inhomogeneities and SAR limitations encountered in routine clinical CMR, though somewhat reduced versus the 7.0 T situation, remain significant. For all these reasons, this study was designed to build and examine the feasibility of a local four channel Tx/Rx cardiac coil array for anatomical and functional cardiac imaging at 3.0 T. For comparison, a homebuilt 4 channel Rx cardiac coil array exhibiting the same geometry as the Tx/Rx coil and a Rx surface coil array were used.}, language = {en} }