@article{ReisgenOlschokJakobsetal.2012, author = {Reisgen, Uwe and Olschok, Simon and Jakobs, Stefan and Schleser, Markus and Mokrov, Oleg and Rossiter, Eduardo}, title = {Laser beam submerged arc hybrid welding}, series = {Physics procedia}, volume = {39}, journal = {Physics procedia}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1875-3892}, doi = {10.1016/j.phpro.2012.10.016}, pages = {75 -- 83}, year = {2012}, abstract = {The laser beam-submerged arc hybrid welding method originates from the knowledge that, with increasing penetration depth, the laser beam process has a tendency to pore formation in the lower weld regions. The coupling with the energy-efficient submerged-arc process improves degassing and reduces the tendency to pore formation. The high deposition rate of the SA process in combination with the laser beam process offers, providing the appropriate choice of weld preparation, the possibility of welding plates with a thickness larger than 20° mm in a single pass, and also of welding thicker plates with the double-sided single pass technique.}, language = {en} } @article{WincklerKruegerSchnitzleretal.2014, author = {Winckler, Silvia and Krueger, Rolf and Schnitzler, Thomas and Zang, Werner and Fischer, Rainer and Biselli, Manfred}, title = {A sensitive monitoring system for mammalian cell cultivation processes: a PAT approach}, series = {Bioprocess and biosystems engineering}, volume = {37}, journal = {Bioprocess and biosystems engineering}, number = {5}, publisher = {Springer}, address = {Berlin, Heidelberg}, issn = {1615-7591 (Print) 1615-7605 (Online)}, doi = {10.1007/s00449-013-1062-8}, pages = {901 -- 912}, year = {2014}, abstract = {Biopharmaceuticals such as antibodies are produced in cultivated mammalian cells, which must be monitored to comply with good manufacturing practice. We, therefore, developed a fully automated system comprising a specific exhaust gas analyzer, inline analytics and a corresponding algorithm to precisely determine the oxygen uptake rate, carbon dioxide evolution rate, carbon dioxide transfer rate, transfer quotient and respiratory quotient without interrupting the ongoing cultivation, in order to assess its reproducibility. The system was verified using chemical simulation experiments and was able to measure the respiratory activity of hybridoma cells and DG44 cells (derived from Chinese hamster ovary cells) with satisfactory results at a minimum viable cell density of ~2.0 × 10⁵ cells ml⁻¹. The system was suitable for both batch and fed-batch cultivations in bubble-aerated and membrane-aerated reactors, with and without the control of pH and dissolved oxygen.}, language = {en} } @article{Schnitzler2009, author = {Schnitzler, Thomas}, title = {Cultivation of hybridoma cell line CF-10H5 (DSMZ ACC477)}, series = {Application notes / Sartorius stedim biotech}, journal = {Application notes / Sartorius stedim biotech}, pages = {1 -- 4}, year = {2009}, language = {en} } @article{Schnitzler2009, author = {Schnitzler, Thomas}, title = {Kultivierung der Hybridomazelllinie CF-10H5 (DSMZ ACC477)}, series = {Application notes / Sartorius stedim biotech}, journal = {Application notes / Sartorius stedim biotech}, publisher = {Sartorius Stedim Biotec}, address = {Aubagne}, year = {2009}, language = {de} } @article{SchnitzlerBiselli2005, author = {Schnitzler, Thomas and Biselli, Manfred}, title = {Cultivo de lineas celulares de hibridoma por CF-10H5 (DSMZ ACC477) en el BIOSTAT B plus}, series = {Noticias tecnicas del laboratorio}, volume = {13}, journal = {Noticias tecnicas del laboratorio}, number = {3}, pages = {7 -- 8}, year = {2005}, language = {es} } @article{HellmannsBoehmDilger2006, author = {Hellmanns, Mark and B{\"o}hm, Stefan and Dilger, Klaus}, title = {Manual applications of adhesives}, series = {Journal of adhesion and interface}, volume = {Vol. 7}, journal = {Journal of adhesion and interface}, number = {No. 4}, pages = {24 -- 27}, year = {2006}, language = {en} } @article{ReisgenSchleserAbdurakhmanovetal.2012, author = {Reisgen, Uwe and Schleser, Markus and Abdurakhmanov, Aydemir and Gumenyuk, Andrey}, title = {Measuring of plasma properties induced by non-vacuum electron beam welding}, series = {Physics of plasma}, volume = {19}, journal = {Physics of plasma}, number = {1}, publisher = {AIP Publishing}, address = {Melville, NY}, issn = {1089-7674 (E-Journal); 1070-664X (Print)}, doi = {10.1063/1.3675874}, pages = {1 -- 7}, year = {2012}, abstract = {Electron beam plasma measurement was realised by means of DIABEAM system invented by ISF RWTH Aachen. The Langmuir probe method is used for measurement. The relative simplicity of the method and the possibility of dispersion of high power on the probe allow its application for the investigation of high-power electron beams. The key element of the method is a rotating thin tungsten wire, which intersects the beam transversely on its axis and collects part of the current by itself. The signals, which are registered in the DIABEAM as a voltage, were taken in the form of amplitude. The conversion of the probe current into the distribution along the beam radius was realised using the Abel's method. A voltage-current characteristic was built for the beam current. The local electron density as well as the electron temperature, the floating potential and the plasma potential were measured and calculated by means of this characteristic.}, language = {en} } @article{ReisgenSchleserMokrovetal.2012, author = {Reisgen, Uwe and Schleser, Markus and Mokrov, Oleg and Zabirov, Alexander and F{\"u}ssel, Uwe and Schnick, Michael and Hertel, Martin and Jaeckel, Sebastian}, title = {Modellierung und Visualisierung der MSG-Lichtbogenprozesse}, series = {Schweissen und Schneiden : Fachzeitschrift f{\"u}r Schweißen und verwandte Verfahren}, volume = {64}, journal = {Schweissen und Schneiden : Fachzeitschrift f{\"u}r Schweißen und verwandte Verfahren}, number = {4}, publisher = {DVS Verlag}, address = {D{\"u}sseldorf}, issn = {0036-7184}, pages = {166 -- 174}, year = {2012}, language = {de} } @article{ScheikSchleserReisgen2012, author = {Scheik, Sven and Schleser, Markus and Reisgen, Uwe}, title = {Thermisches Direktf{\"u}gen von Metall und Kusntstoff: eine Alternative zur Klebtechnik}, series = {Adh{\"a}sion : Kleben \& Dichten}, volume = {56}, journal = {Adh{\"a}sion : Kleben \& Dichten}, number = {11}, publisher = {Springer Vieweg}, address = {Wiesbaden}, issn = {0001-8198 (E-Journal); 0001-8198 (Print)}, doi = {10.1007/s35145-012-0005-x}, pages = {36 -- 40}, year = {2012}, abstract = {Im Rahmen des Exzellenzclusters „Integrative Produktionstechnik f{\"u}r Hochlohnl{\"a}nder" der RWTHAachen University werden derzeit alternative Verfahren zur Herstellung von Metall/Kunststoff- Verbindungen untersucht. Eines davon ist das thermische Direktf{\"u}gen, das eine stoffschl{\"u}ssige Verbindung zwischen Kunststoff und Metall erm{\"o}glicht und ohne die Verwendung von Klebstoffen, Haftvermittlern oder mechanischen Verbindungshilfen auskommt.}, language = {de} } @article{ReisgenSchleserMokrovetal.2012, author = {Reisgen, Uwe and Schleser, Markus and Mokrov, Oleg and Zabirov, Alexander and F{\"u}ssel, Uwe and Schnick, Michael and Hertel, Martin and Jaeckel, Sebastian}, title = {Modelling and visualisation of the GMA process}, series = {Welding and Cutting}, volume = {11}, journal = {Welding and Cutting}, number = {4}, publisher = {DVS Verlag}, address = {D{\"u}sseldorf}, issn = {1612-3433}, pages = {242 -- 249}, year = {2012}, language = {en} }