@article{MolinnusSorichBartzetal.2016, author = {Molinnus, Denise and Sorich, Maren and Bartz, Alexander and Siegert, Petra and Willenberg, Holger S. and Lisdat, Fred and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Towards an adrenaline biosensor based on substrate recycling amplification in combination with an enzyme logic gate}, series = {Sensors and Actuators B: Chemical}, volume = {237}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2016.06.064}, pages = {190 -- 195}, year = {2016}, abstract = {An amperometric biosensor using a substrate recycling principle was realized for the detection of low adrenaline concentrations (1 nM) by measurements in phosphate buffer and Ringer's solution at pH 6.5 and pH 7.4, respectively. In proof-of-concept experiments, a Boolean logic-gate principle has been applied to develop a digital adrenaline biosensor based on an enzyme AND logic gate. The obtained results demonstrate that the developed digital biosensor is capable for a rapid qualitative determination of the presence/absence of adrenaline in a YES/NO statement. Such digital biosensor could be used in clinical diagnostics for the control of a correct insertion of a catheter in the adrenal veins during adrenal venous-sampling procedure.}, language = {en} } @article{GhoschBaierSchuetzetal.2016, author = {Ghosch, S. and Baier, M. and Sch{\"u}tz, J. and Schneider, Felix and Scherer, Ulrich W.}, title = {Analysis of electronic autoradiographs by mathematical post-processing}, series = {Radiation Effects and Defects in Solids: Incorporating plasma science and plasma technology}, volume = {171}, journal = {Radiation Effects and Defects in Solids: Incorporating plasma science and plasma technology}, number = {1-2}, publisher = {Taylor \& Francis}, address = {London}, issn = {1029-4953}, doi = {10.1080/10420150.2016.1155587}, pages = {161 -- 172}, year = {2016}, abstract = {Autoradiography is a well-established method of nuclear imaging. When different radionuclides are present simultaneously, additional processing is needed to distinguish distributions of radionuclides. In this work, a method is presented where aluminium absorbers of different thickness are used to produce images with different cut-off energies. By subtracting images pixel-by-pixel one can generate images representing certain ranges of β-particle energies. The method is applied to the measurement of irradiated reactor graphite samples containing several radionuclides to determine the spatial distribution of these radionuclides within pre-defined energy windows. The process was repeated under fixed parameters after thermal treatment of the samples. The greyscale images of the distribution after treatment were subtracted from the corresponding pre-treatment images. Significant changes in the intensity and distribution of radionuclides could be observed in some samples. Due to the thermal treatment parameters the most significant differences were observed in the ³H and ¹⁴C inventory and distribution.}, language = {en} } @book{Lauth2016, author = {Lauth, Jakob}, title = {Physikalische Chemie, 5: Elektrochemie}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-662-47559-1}, pages = {55 Seiten}, year = {2016}, language = {de} } @book{Lauth2016, author = {Lauth, Jakob}, title = {Physikalische Chemie, 4: Reaktionskinetik}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-662-47674-1}, pages = {52 Seiten}, year = {2016}, language = {de} } @book{Lauth2016, author = {Lauth, Jakob}, title = {Physikalische Chemie, 3: Phasengleichgewichte}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-662-47571-3}, pages = {57 Seiten}, year = {2016}, language = {de} } @book{Lauth2016, author = {Lauth, Jakob}, title = {Physikalische Chemie, 2: Chemische Thermodynamik}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-662-47621-5}, pages = {77 Seiten}, year = {2016}, language = {de} } @book{Lauth2016, author = {Lauth, Jakob}, title = {Physikalische Chemie, 1: Grundlagen der Thermodynamik und Verhalten der Gase}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-662-47676-5}, pages = {57 Seiten}, year = {2016}, language = {de} } @book{LauthKowalczyk2016, author = {Lauth, Jakob and Kowalczyk, J{\"u}rgen}, title = {Einf{\"u}hrung in die Physik und Chemie der Grenzfl{\"a}chen und Kolloide}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-662-47018-3}, doi = {10.1007/978-3-662-47018-3}, pages = {Online-Ressource (XIX, 522 S., 341 Abb.)}, year = {2016}, language = {de} } @book{Feuerriegel2016, author = {Feuerriegel, Uwe}, title = {Verfahrenstechnik mit EXCEL: Verfahrenstechnische Berechnungen effektiv durchf{\"u}hren und professionell dokumentieren}, publisher = {Springer Fachmedien}, address = {Wiesbaden}, isbn = {978-3-658-02902-9}, doi = {10.1007/978-3-658-02903-6}, pages = {XVII, 381 Seiten}, year = {2016}, language = {de} } @incollection{ArtmannMeruvuKizildagetal.2018, author = {Artmann, Gerhard and Meruvu, Haritha and Kizildag, Sefa and Temiz Artmann, Ayseg{\"u}l}, title = {Functional Toxicology and Pharmacology Test of Cell Induced Mechanical Tensile Stress in 2D and 3D Tissue Cultures}, series = {Biological, Physical and Technical Basics of Cell Engineering}, booktitle = {Biological, Physical and Technical Basics of Cell Engineering}, editor = {Artmann, Gerhard and Temiz Artmann, Ayseg{\"u}l and Zhubanova, Azhar A. and Digel, Ilya}, publisher = {Springer}, address = {Singapore}, isbn = {978-981-10-7904-7}, doi = {10.1007/978-981-10-7904-7_7}, pages = {157 -- 192}, year = {2018}, abstract = {Mechanical forces/tensile stresses are critical determinants of cellular growth, differentiation and migration patterns in health and disease. The innovative "CellDrum technology" was designed for measuring mechanical tensile stress of cultured cell monolayers/thin tissue constructs routinely. These are cultivated on very thin silicone membranes in the so-called CellDrum. The cell layers adhere firmly to the membrane and thus transmit the cell forces generated. A CellDrum consists of a cylinder which is sealed from below with a 4 μm thick, biocompatible, functionalized silicone membrane. The weight of cell culture medium bulbs the membrane out downwards. Membrane indentation is measured. When cells contract due to drug action, membrane, cells and medium are lifted upwards. The induced indentation changes allow for lateral drug induced mechanical tension quantification of the micro-tissues. With hiPS-induced (human) Cardiomyocytes (CM) the CellDrum opens new perspectives of individualized cardiac drug testing. Here, monolayers of self-beating hiPS-CMs were grown in CellDrums. Rhythmic contractions of the hiPS-cells induce membrane up-and-down deflections. The recorded cycles allow for single beat amplitude, single beat duration, integration of the single beat amplitude over the beat time and frequency analysis. Dose effects of agonists and antagonists acting on Ca2+ channels were sensitively and highly reproducibly observed. Data were consistent with published reference data as far as they were available. The combination of the CellDrum technology with hiPS-Cardiomyocytes offers a fast, facile and precise system for pharmacological and toxicological studies. It allows new preclinical basic as well as applied research in pharmacolgy and toxicology.}, language = {en} }