@misc{TippkoetterPasteurMeyeretal.2012, author = {Tippk{\"o}tter, Nils and Pasteur, A. and Meyer, C. and Kampeis, P. and Diller, R. and Ulber, Roland}, title = {Aufreinigung von Cephalosporin C durch por{\"o}se, selektiv-beschichtete Magnetpartikel}, series = {Chemie Ingenieur Technik}, volume = {84}, journal = {Chemie Ingenieur Technik}, number = {8}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201250391}, pages = {1369 -- 1370}, year = {2012}, abstract = {Die selektive Isolierung von Cephalosporin C (CPC) aus komplexen Fermentationssuspensionen unter Einsatz magnetischer Separation ist das Ziel dieser Arbeit. Das Verfahren wird im fr{\"u}hen Stadium der Aufarbeitung genutzt, um CPC zu stabilisieren und somit die Produktausbeute zu erh{\"o}hen. Als Adsorbersysteme f{\"u}r CPC wurden neben einem projektinternen magnetischen Material ND 10322, dessen Oberfl{\"a}chenladungen spezifisch f{\"u}r die Bindung des Zielmolek{\"u}ls synthetisiert wurden, verschiedene kommerzielle Partikelsysteme verglichen. Es konnten massenspezifische Maximalbeladungen von 51 mg g⁻¹ erreicht werden. Weiterhin wurde die Stabilit{\"a}t von CPC untersucht. Unter optimalen Adsorptionsbedingungen kann CPC stabilisiert werden, so dass die Geschwindigkeitskonstante der Degradation des b-Lactam-Rings unter diesen Bedingungen unter 0,005 h⁻¹ liegt. Untersuchungen zur Wiederverwertbarkeit der neuen Adsorbers zeigten eine irreversible Bindung geringer CPC-Mengen nach dem ersten Einsatz. Nach zw{\"o}lf Zyklen tritt eine irreversible Bindung von CPC ein, was zu einer signifikanten Reduktion der Adsorptionsf{\"a}higkeit f{\"u}hrt. Die Anh{\"a}ufung des CPC auf dem Adsorber konnte durch IR-Untersuchungen auf die Bildung einer Peptidbindung zwischen Carboxylgruppen des CPC und Aminogruppe der Adsorberoberfl{\"a}che zur{\"u}ckgef{\"u}hrt werden.}, language = {de} } @misc{SiekerTippkoetterMuffleretal.2012, author = {Sieker, T. and Tippk{\"o}tter, Nils and Muffler, K. and Ulber, Roland}, title = {Herstellung von Ethanol, Phenols{\"a}uren, organischen S{\"a}uren und Biogas durch vollst{\"a}ndige Nutzung von Grassilage in einer Bioraffinerie}, series = {Chemie Ingenieur Technik}, volume = {84}, journal = {Chemie Ingenieur Technik}, number = {8}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.201250415}, pages = {1297}, year = {2012}, abstract = {Gr{\"a}ser sind in der Lage, einen großen Teil der f{\"u}r eine biobasierte Wirtschaft ben{\"o}tigten Biomasse zur Verf{\"u}gung zustellen. Um eine ganzj{\"a}hrige Nutzung des Grases zu gew{\"a}hrleisten, muss eine stabile Lagerung des Grases erreicht werden, was z. B. durch Silieren m{\"o}glich ist. Die konservierende Wirkung der Silierung beruht auf der Bildung organischer S{\"a}uren. Um diese zu gewinnen, wird die Silage gepresst, die organischen S{\"a}uren {\"u}ber Fl{\"u}ssig/Fl{\"u}ssig-Extraktion aus dem Presssaft abgetrenntund mittels chromatographischer Methoden weiter aufgereinigt. Im pr{\"a}sentierten Konzept werden die im Presskuchen enthaltenen Lignocellulosen hydrolysiert und die erhaltenen Monosaccharide zu Ethanol fermentiert. Die Phenols{\"a}uren, die in Gr{\"a}sern die Rolle des Lignins {\"u}bernehmen, k{\"o}nnen simultan mit der Hydrolyse der Polysaccharide enzymatisch abgetrennt und als Nebenprodukt gewonnen werden. Die nach der Abtrennung des Ethanols verbleibenden Fermentationsreststoffe werden f{\"u}r die Herstellung von Biogas verwendet.}, language = {de} } @misc{PothMonzonTippkoetteretal.2009, author = {Poth, S. and Monzon, M. and Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Fermentation von Hydrolysaten aus Lignocellulose}, series = {Chemie Ingenieur Technik}, volume = {81}, journal = {Chemie Ingenieur Technik}, number = {8}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.200950243}, pages = {1220}, year = {2009}, abstract = {Die {\"o}konomische Abh{\"a}ngigkeit von fossilen Brennstoffen und der klimatische Wandel durch die Nutzung dieser haben zu einer intensiven Suche nach erneuerbaren Rohstoffen f{\"u}r die Produktion von Chemikalien und Treibstoffen gef{\"u}hrt. Ein viel versprechender Rohstoff in diesem Zusammenhang sind Zucker, die mittels enzymatischer Hydrolyse aus Lignocellulose gewonnen werden k{\"o}nnen. Die Fermentation erfolgt mit Cellulose- bzw. Hemicellulose-Fraktionen, welche durch thermo-chemische Vorbehandlung von Holz gewonnen und anschließend enzymatisch hydrolysiert werden. Die in den Hydrolysaten enthaltenen Zuckermonomere dienen als Kohlenstoffquelle f{\"u}r die Produktion von Ethanol. Da sowohl Glucose als auch Xylose in den unterschiedlichen Fraktionen enthalten sind, wird zur Umsetzung dieser eine Co-Fermentation zweier Hefen durchgef{\"u}hrt. Im Rahmen der Optimierung dieser Fermentationen werden neben der Erg{\"a}nzung der Hydrolysate durch notwendige Salze auch Verfahrenweisen wie Fed-Batch-Fermentationen untersucht. Ein weiterer interessanter Ansatz, welcher in diesem Rahmen gepr{\"u}ft wird, ist die enzymatische Hydrolyse der Lignocellulose-Fraktionen und die simultane Fermentation der dabei entstehenden Zucker in einem Schritt. Des Weiteren wurde die Eignung der Hydrolysate f{\"u}r die Biomasseproduktion anderer Mikroorganismen wie Escherichia coli getestet.}, language = {de} } @misc{FrauenrathPfeifferHezeletal.2012, author = {Frauenrath, Tobias and Pfeiffer, Harald and Hezel, Fabian and Dieringer, Matthias A. and Winter, Lukas and Gr{\"a}ßl, Andreas and Santoro, Davide and {\"O}zerdem, Celal and Renz, Wolfgang and Greiser, Andreas and Niendorf, Thoralf}, title = {Lessons learned from cardiac MRI at 7.0 T: LV function assessment at 3.0 T using local multi-channel transceiver coil arrays}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {Cardiac MR (CMR) is of proven clinical value but also an area of vigorous ongoing research since image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Recent developments of CMR at 7.0 T have been driven by pioneering explorations into novel multichannel transmit and receive coil array technology to tackle the challenges B1+-field inhomogeneities, to offset specific-absorption rate (SAR) constraints and to reduce banding artifacts in SSFP imaging. For this study, recognition of the benefits and performance of local surface Tx/Rx-array structures recently established at 7.0 T inspired migration to 3.0 T, where RF inhomogeneities and SAR limitations encountered in routine clinical CMR, though somewhat reduced versus the 7.0 T situation, remain significant. For all these reasons, this study was designed to build and examine the feasibility of a local four channel Tx/Rx cardiac coil array for anatomical and functional cardiac imaging at 3.0 T. For comparison, a homebuilt 4 channel Rx cardiac coil array exhibiting the same geometry as the Tx/Rx coil and a Rx surface coil array were used.}, language = {en} } @misc{FrauenrathFuchsHezeletal.2012, author = {Frauenrath, Tobias and Fuchs, Katharina and Hezel, Fabian and Dieringer, Matthias A. and Rieger, Jan and Niendorf, Thoralf}, title = {Improved cardiac triggering by combining multiple physiological signals: a cardiac MR feasibility study at 7.0 T}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {In current clinical cardiovascular MR (CMR) practice cardiac motion is commonly dealt with using ECG based synchronization. However, ECG is corrupted by magneto-hydrodynamic (MHD) effects in magnetic fields. This leads to artifacts in the ECG trace and evokes severe T-wave elevations, which might be misinterpreted as R-waves resulting in erroneous triggering. At (ultra)high field strengths, the propensity of ECG recordings to MHD effects is further pronounced. Pulse oximetry (POX) being inherently sensitive to blood oxygenation provides an alternative approach for cardiac gating. However, due to the travel time of the blood the peak of maximum oxygenation and hence the trigger is delayed by approx. 300 ms with respect to the ECG's R-wave. Also the peak of maximum oxygenation shows a jitter of up to 65 ms. Alternative triggering approaches include acoustic cardiac triggering (ACT). In current clinical practice cardiac gating / triggering commonly relies on using single physiological signals only. Realizing this limitation this study proposes a combined triggering approach which exploits multiple physiological signals including ECG, POX or ACT to track cardiac activity. The feasibility of the coupled approach is examined for LV function assessment at 7.0 T. For this purpose, breath-held 2D-CINE imaging in conjunction with cardiac synchronization was performed paralleled by real time logging of physiological waveforms to track (mis)synchronization between the cardiac cycle and data acquisition. Combinations of the ECG, POX and ACT signals were evaluated and processed in real time to facilitate reliable trigger information.}, language = {en} } @misc{TkachenkovonKnobelsdorffBrenkenhoffKleindienstetal.2012, author = {Tkachenko, Valeriy and von Knobelsdorff-Brenkenhoff, Florian and Kleindienst, Denise and Winter, Lukas and Rieger, Jan and Frauenrath, Tobias and Dieringer, Matthias A. and Santoro, Davide and Niendorf, Thoralf and Schulz-Menger, Jeanette}, title = {Cardiovasular MR at 7Tesla: assessment of the right ventricle}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {The assessment of the right ventricle (RV) is a challenge in today's cardiology, but of growing clinical impact regarding patient prognosis in different cardiac diseases. The detection and differentiation of small wall motion abnormalities may help to enhance the differentiation of cardiomyopathies including Arrhythmogenic Rightventricular Cardiomyopathy. Cardiovascular magnetic resonance (CMR) at 1.5T is the accepted gold standard for RV quantification. The higher spatial resolution achievable at ultrahigh field strength (UHF) offers the potential to gain new insights into the structure and function of the RV. To approach this goal accurate RV chamber quantification at 7T has to be proven. Consequently this study examines the feasibility of assessment of RV dimensions and function at 7T using improved spatial resolution enabled by the intrinsic sensitivity gain of UHF CMR. For this purpose, a dedicated 16 channel TX/RX RF coil array is used together with 2D CINE fast gradient echo (FGRE) imaging. For comparison RV chamber quantification is conducted at 1.5T using a SSFP based state of the art clinical protocol.}, language = {en} } @misc{GraesslRenzHezeletal.2012, author = {Gr{\"a}ßl, Andreas and Renz, Wolfgang and Hezel, Fabian and Frauenrath, Tobias and Pfeiffer, Harald and Hoffmann, Werner and Kellmann, Peter and Martin, Conrad and Niendorf, Thoralf}, title = {Design, evaluation and application of a modular 32 channel transmit/receive surface coil array for cardiac MRI at 7T}, series = {2012 ISMRM Annual Meeting Proceedings}, journal = {2012 ISMRM Annual Meeting Proceedings}, issn = {1545-4428}, year = {2012}, abstract = {Cardiac MR (CMR) at ultrahigh (≥7.0 T) fields is regarded as one of the most challenging MRI applications. At 7.0 T image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Detrimental effects bear the potential to spoil the signal-to-noise (SNR) and contrast-to-noise (CNR) benefits of cardiac MR (CMR) at 7.0 T. B₁⁺-inhomogeneities and signal voids represent the main challenges. Various pioneering coil concepts have been proposed to tackle these issues, enabling cardiac MRI at 7.0 T. This includes a trend towards an ever larger number of transmit and receive channels. This approach affords multi-dimensional B₁⁺ modulations to improve B₁⁺ shimming performance and to enhance RF efficiency. Also, parallel imaging benefits from a high number of receive channels enabling two-dimensional acceleration. Realizing the limitations of existing coil designs tailored for UHF CMR and recognizing the opportunities of a many element TX/RX channel architecture this work proposes a modular, two dimensional 32-channel transmit and receive array using loop elements and examines its efficacy for enhanced B¹+ homogeneity and improved parallel imaging performance.}, language = {en} } @inproceedings{EggertSchadeBroehletal.2024, author = {Eggert, Mathias and Schade, Maximilian and Br{\"o}hl, Florian and Moriz, Alexander}, title = {Generating synthetic LiDAR point cloud data for object detection using the Unreal Game Engine}, series = {Design Science Research for a Resilient Future (DESRIST 2024)}, booktitle = {Design Science Research for a Resilient Future (DESRIST 2024)}, editor = {Mandviwalla, Munir and S{\"o}llner, Matthias and Tuunanen, Tuure}, publisher = {Springer}, address = {Cham}, isbn = {978-3-031-61174-2 (Print)}, doi = {10.1007/978-3-031-61175-9_20}, pages = {295 -- 309}, year = {2024}, abstract = {Object detection based on artificial intelligence is ubiquitous in today's computer vision research and application. The training of the neural networks for object detection requires large and high-quality datasets. Besides datasets based on image data, datasets derived from point clouds offer several advantages. However, training datasets are sparse and their generation requires a lot of effort, especially in industrial domains. A solution to this issue offers the generation of synthetic point cloud data. Based on the design science research method, the work at hand proposes an approach and its instantiation for generating synthetic point cloud data based on the Unreal Engine. The point cloud quality is evaluated by comparing the synthetic cloud to a real-world point cloud. Within a practical example the applicability of the Unreal Game engine for synthetic point cloud generation could be successfully demonstrated.}, language = {de} } @misc{TippkoetterUlber2009, author = {Tippk{\"o}tter, Nils and Ulber, Roland}, title = {Eine magnetische horizontale Wirbelschicht f{\"u}r die Durchmischung und R{\"u}ckhaltung von magnetisierbaren Mikropartikeln im Durchfluss}, series = {Chemie Ingenieur Technik}, volume = {81}, journal = {Chemie Ingenieur Technik}, number = {8}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.200950076}, pages = {1168}, year = {2009}, abstract = {Magnetisierbare Partikel als Tr{\"a}ger von Katalysatoren k{\"o}nnen durch Anlegen eines magnetisches Feldes einfach und schnell abgetrennt werden. Die Wiedergewinnung von wertvollen Enzymen unter geringem Energie- und Materialeinsatz der magnetischen Abtrennung er{\"o}ffnet einen Wettbewerbsvorteil f{\"u}r Produktionsprozesse. Die Abtrennung von magnetisierbaren Partikeln vom {\"U}berstand wird {\"u}blicherweise entweder durch Anlegen eines {\"a}ußeren Magnetfelds und der resultierenden Ablagerung der Partikel an den Reaktorw{\"a}nden oder durch Hochgradientenmagnetseparation (HGMS)durchgef{\"u}hrt. Beide Verfahren resultieren meist in der Bildung eines Filterkuchens aus Magnetpartikeln und den Feststoffen des Reaktionsmediums. Das magnetische horizontale Wirbelbett erm{\"o}glicht simultan eine kontinuierliche Reaktionsf{\"u}hrung und die R{\"u}ckhaltung der Partikel im Durchfluss. Die Partikelsuspension fließt durch einen Rohrreaktor, der in einem Magnetfeld mit wechselnden Feldgradienten eingebracht ist. Die {\"A}nderung des Magnetfeldgradienten erfolgt entgegen der Str{\"o}mungsrichtung der Reaktionsl{\"o}sung. Durch alternierende Feldmaxima an den beiden Seiten des Reaktors werden die magnetisierbaren Partikel zu dessen W{\"a}nden gezogen. Bei Umkehrung des Feldes wandern die Partikel an die gegen{\"u}berliegende Reaktorwand. Durch Wahl einer geeigneten Wechselfrequenz kann eine kontinuierliche Durchmischung und R{\"u}ckhaltung der Mikropartikel im durchstr{\"o}mten Rohr erreicht werden. Somit k{\"o}nnen Immobilisierungsreaktionen und Biotransformationen mit den Partikelsystemen im Durchfluss durchgef{\"u}hrt werden.}, language = {en} } @misc{FrauenrathNiendorf2012, author = {Frauenrath, Tobias and Niendorf, Thoralf}, title = {MRT-Vorrichtung und Verfahren zum Betreiben einer MRT-Vorrichtung}, year = {2012}, abstract = {A magnetic resonance tomography (MRT) apparatus (1) for the examination of a body (14) comprises parameter acquisition devices (13) for the acquisition of cardiovascular parameters of the body (14) and a control device (15) in communication with the parameter acquisition devices (13) for synchronizing the imaging, wherein the control device (15) is adapted to analyse the data of at least two parameter acquisition devices (13) and to output a control signal based on the analysis.}, language = {de} }