@inproceedings{WeilPoghossianSchoeningetal.2012, author = {Weil, M. and Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Cherstvy, A.}, title = {Electrical monitoring of layer-by-layer adsorption of oppositely charged macromolecules by means of capacitive field-effect devices}, isbn = {978-3-9813484-2-2}, doi = {10.5162/IMCS2012/P2.5.2}, pages = {1575 -- 1578}, year = {2012}, language = {en} } @article{LaackRefisch1989, author = {Laack, Walter van and Refisch, A.}, title = {Neuralgic amyotrophy of the lumbar area. Case Report / Refisch, A. ; Laack, W. van}, series = {Archives of Orthopaedic and Trauma Surgery. 108 (1989), H. 5}, journal = {Archives of Orthopaedic and Trauma Surgery. 108 (1989), H. 5}, isbn = {0936-8051}, pages = {329 -- 332}, year = {1989}, language = {en} } @article{Digel2011, author = {Digel, Ilya}, title = {Primary thermosensory events in cells}, series = {Transient receptor potential channels / Md. Shahidul Islam, ed.}, journal = {Transient receptor potential channels / Md. Shahidul Islam, ed.}, publisher = {Springer}, address = {Dordrecht [u.a.]}, isbn = {978-94-007-0264-6}, pages = {451 -- 468}, year = {2011}, language = {en} } @inproceedings{StaatHeitzerHicken1999, author = {Staat, Manfred and Heitzer, Michael and Hicken, E. F.}, title = {LISA - ein europ{\"a}isches Projekt zur FEM-basierten Traglast- und Einspielanalyse}, year = {1999}, abstract = {Traglast- und Einspielanalysen sind vereinfachte doch exakte Verfahren der Plastizit{\"a}t, die neben ausreichender Verformbarkeit keine einschr{\"a}nkenden Voraussetzungen beinhalten. Die Vereinfachungen betreffen die Beschaffung der Daten und Modelle f{\"u}r Details der Lastgeschichte und des Stoffverhaltens. Anders als die klassische Behandlung nichtlinearer Probleme der Strukturmechanik f{\"u}hrt die Methode auf Optimierungsprobleme. Diese sind bei realistischen FEM-Modellen sehr groß. Das hat die industrielle Anwendung der Traglast- und Einspielanalysen stark verz{\"o}gert. Diese Situation wird durch das Brite-EuRam Projekt LISA grundlegend ge{\"a}ndert. In LISA entsteht auf der Basis des industriellen FEM-Programms PERMAS ein Verfahren zur direkten Berechnung der Tragf{\"a}higkeit duktiler Strukturen. Damit kann der Betriebsbereich von Komponenten und Bauwerken auf den plastischen Bereich erweitert werden, ohne den Aufwand gegen{\"u}ber elastischen Analysen wesentlich zu erh{\"o}hen. Die beachtlichen Rechenzeitgewinne erlauben Parameterstudien und die Berechnung von Interaktionsdiagrammen, die einen schnellen {\"U}berblick {\"u}ber m{\"o}gliche Betriebsbereiche vermitteln. Es zeigt sich, daß abh{\"a}ngig von der Komponente und ihren Belastungen teilweise entscheidende Sicherheitsgewinne zur Erweiterung der Betriebsbereiche erzielt werden k{\"o}nnen. Das Vorgehen erfordert vom Anwender oft ein gewisses Umdenken. Es werden keine Spannungen berechnet, um damit Sicherheit und Lebensdauer zu interpretieren. Statt dessen berechnet man direkt die gesuchte Sicherheit. Der Post-Prozessor wird nur noch zur Modell- und Rechenkontrolle ben{\"o}tigt. Das Vorgehen ist {\"a}hnlich der Stabilit{\"a}tsanalyse (Knicken, Beulen). Durch namhafte industrielle Projektpartner werden Validierung und die Anwendbarkeit auf eine breite Palette technischer Probleme garantiert. Die ebenfalls in LISA entwickelten Zuverl{\"a}ssigkeitsanalysen sind nichlinear erst auf der Basis direkter Verfahren effektiv m{\"o}glich. Ohne Traglast- und Einspielanalyse ist plastische Strukturoptimierung auch heute kaum durchf{\"u}hrbar. Auf die vorgesehenen Erweiterungen der Werkstoffmodellierung f{\"u}r nichtlineare Verfestigung und f{\"u}r Sch{\"a}digung konnte hier nicht eingegangen werden. Es herrscht ein deutlicher Mangel an Experimenten zum Nachweis der Grenzen zwischen elastischem Einspielen und dem Versagen durch LCF oder durch Ratchetting.}, subject = {Einspielen }, language = {de} } @article{SchoeningNaetherAugeretal.2005, author = {Sch{\"o}ning, Michael Josef and N{\"a}ther, Niko and Auger, V. and Poghossian, Arshak and Koudelka-Hep, M.}, title = {Miniaturised flow-through cell with integrated capacitive EIS sensor fabricated at wafer level using Si and SU-8 technologies}, series = {Sensors and Actuators B. 108 (2005), H. 1-2}, journal = {Sensors and Actuators B. 108 (2005), H. 1-2}, isbn = {0925-4005}, pages = {986 -- 992}, year = {2005}, language = {en} } @incollection{Laack2014, author = {Laack, Walter van}, title = {Gefahren heutiger neurologischer Schlussfolgerungen f{\"u}r ethische Verantwortung}, series = {Ethik und Moral in Staat, Wirtschaft und Gesellschaft : 5. Rotary-Tag, 14.-15.2.2014, Kleve}, booktitle = {Ethik und Moral in Staat, Wirtschaft und Gesellschaft : 5. Rotary-Tag, 14.-15.2.2014, Kleve}, publisher = {Edition Virgines}, address = {Lingen}, organization = {Rotary-Tag <5, 2014, Kleve>}, isbn = {978-3-944011-21-9}, pages = {98 -- 114}, year = {2014}, language = {de} } @article{JablonskiPoghossianKeusgenetal.2021, author = {Jablonski, Melanie and Poghossian, Arshak and Keusgen, Michael and Wege, Christina and Sch{\"o}ning, Michael Josef}, title = {Detection of plant virus particles with a capacitive field-effect sensor}, series = {Analytical and Bioanalytical Chemistry}, volume = {413}, journal = {Analytical and Bioanalytical Chemistry}, publisher = {Springer Nature}, address = {Cham}, issn = {1618-2650}, doi = {10.1007/s00216-021-03448-8}, pages = {5669 -- 5678}, year = {2021}, abstract = {Plant viruses are major contributors to crop losses and induce high economic costs worldwide. For reliable, on-site and early detection of plant viral diseases, portable biosensors are of great interest. In this study, a field-effect SiO2-gate electrolyte-insulator-semiconductor (EIS) sensor was utilized for the label-free electrostatic detection of tobacco mosaic virus (TMV) particles as a model plant pathogen. The capacitive EIS sensor has been characterized regarding its TMV sensitivity by means of constant-capacitance method. The EIS sensor was able to detect biotinylated TMV particles from a solution with a TMV concentration as low as 0.025 nM. A good correlation between the registered EIS sensor signal and the density of adsorbed TMV particles assessed from scanning electron microscopy images of the SiO2-gate chip surface was observed. Additionally, the isoelectric point of the biotinylated TMV particles was determined via zeta potential measurements and the influence of ionic strength of the measurement solution on the TMV-modified EIS sensor signal has been studied.}, language = {en} } @article{PoghossianSchoening2021, author = {Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Recent progress in silicon-based biologically sensitive field-effect devices}, series = {Current Opinion in Electrochemistry}, journal = {Current Opinion in Electrochemistry}, number = {Article number: 100811}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2451-9103}, doi = {10.1016/j.coelec.2021.100811}, year = {2021}, abstract = {Biologically sensitive field-effect devices (BioFEDs) advantageously combine the electronic field-effect functionality with the (bio)chemical receptor's recognition ability for (bio)chemical sensing. In this review, basic and widely applied device concepts of silicon-based BioFEDs (ion-sensitive field-effect transistor, silicon nanowire transistor, electrolyte-insulator-semiconductor capacitor, light-addressable potentiometric sensor) are presented and recent progress (from 2019 to early 2021) is discussed. One of the main advantages of BioFEDs is the label-free sensing principle enabling to detect a large variety of biomolecules and bioparticles by their intrinsic charge. The review encompasses applications of BioFEDs for the label-free electrical detection of clinically relevant protein biomarkers, deoxyribonucleic acid molecules and viruses, enzyme-substrate reactions as well as recording of the cell acidification rate (as an indicator of cellular metabolism) and the extracellular potential.}, language = {en} } @article{PoghossianSchoeningSchrothetal.2001, author = {Poghossian, Arshak and Sch{\"o}ning, Michael Josef and Schroth, P. and Simonis, A. and L{\"u}th, H.}, title = {An ISFET-based penicillin sensor with high sensitivity, low detection limit and long lifetime}, series = {Sensors and Actuators B. 76 (2001), H. 1-3}, journal = {Sensors and Actuators B. 76 (2001), H. 1-3}, isbn = {0925-4005}, pages = {519 -- 526}, year = {2001}, language = {en} } @article{HuckSchiffelsHerreraetal.2013, author = {Huck, Christina and Schiffels, Johannes and Herrera, Cony N. and Schelden, Maximilian and Selmer, Thorsten and Poghossian, Arshak and Baumann, Marcus and Wagner, Patrick and Sch{\"o}ning, Michael Josef}, title = {Metabolic responses of Escherichia coli upon glucose pulses captured by a capacitive field-effect sensor}, series = {Physica Status Solidi (A)}, volume = {210}, journal = {Physica Status Solidi (A)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0031-8965}, doi = {10.1002/pssa.201200900}, pages = {926 -- 931}, year = {2013}, abstract = {Living cells are complex biological systems transforming metabolites taken up from the surrounding medium. Monitoring the responses of such cells to certain substrate concentrations is a challenging task and offers possibilities to gain insight into the vitality of a community influenced by the growth environment. Cell-based sensors represent a promising platform for monitoring the metabolic activity and thus, the "welfare" of relevant organisms. In the present study, metabolic responses of the model bacterium Escherichia coli in suspension, layered onto a capacitive field-effect structure, were examined to pulses of glucose in the concentration range between 0.05 and 2 mM. It was found that acidification of the surrounding medium takes place immediately after glucose addition and follows Michaelis-Menten kinetic behavior as a function of the glucose concentration. In future, the presented setup can, therefore, be used to study substrate specificities on the enzymatic level and may as well be used to perform investigations of more complex metabolic responses. Conclusions and perspectives highlighting this system are discussed.}, language = {en} } @inproceedings{WeldenSeverinsPoghossianetal.2022, author = {Welden, Melanie and Severins, Robin and Poghossian, Arshak and Wege, Christina and Siegert, Petra and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Studying the immobilization of acetoin reductase with Tobacco mosaic virus particles on capacitive field-effect sensors}, series = {2022 IEEE International Symposium on Olfaction and Electronic Nose (ISOEN)}, booktitle = {2022 IEEE International Symposium on Olfaction and Electronic Nose (ISOEN)}, publisher = {IEEE}, isbn = {978-1-6654-5860-3 (Online)}, doi = {10.1109/ISOEN54820.2022.9789657}, pages = {4 Seiten}, year = {2022}, abstract = {A capacitive electrolyte-insulator-semiconductor (EISCAP) biosensor modified with Tobacco mosaic virus (TMV) particles for the detection of acetoin is presented. The enzyme acetoin reductase (AR) was immobilized on the surface of the EISCAP using TMV particles as nanoscaffolds. The study focused on the optimization of the TMV-assisted AR immobilization on the Ta 2 O 5 -gate EISCAP surface. The TMV-assisted acetoin EISCAPs were electrochemically characterized by means of leakage-current, capacitance-voltage, and constant-capacitance measurements. The TMV-modified transducer surface was studied via scanning electron microscopy.}, language = {en} } @inproceedings{PoghossianBronderSchejaetal.2016, author = {Poghossian, Arshak and Bronder, Thomas and Scheja, S. and Wu, Chunsheng and Metzger-Boddien, C. and Keusgen, M. and Sch{\"o}ning, Michael Josef}, title = {Label-free Electrostatic Detection of DNA Amplification by PCR Using Capacitive Field-effect Devices}, series = {Procedia Engineering}, volume = {Vol. 168}, booktitle = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2016.11.512}, pages = {514 -- 517}, year = {2016}, abstract = {A capacitive field-effect EIS (electrolyte-insulator-semiconductor) sensor modified with a positively charged weak polyelectrolyte of poly(allylamine hydrochloride) (PAH)/single-stranded probe DNA (ssDNA) bilayer has been used for a label-free electrostatic detection of pathogen-specific DNA amplification via polymerase chain reaction (PCR). The sensor is able to distinguish between positive and negative PCR solutions, to detect the existence of target DNA amplicons in PCR samples and thus, can be used as tool for a quick verification of DNA amplification and the successful PCR process.}, language = {en} } @article{SiqueiraWernerBaeckeretal.2009, author = {Siqueira, Jose R. and Werner, Frederik and B{\"a}cker, Matthias and Poghossian, Arshak and Zucolotto, Valtencir and Oliveira, Osvaldo N. Jr. and Sch{\"o}ning, Michael Josef}, title = {Layer-by-Layer Assembly of Carbon Nanotubes Incorporated in Light-Addressable Potentiometric Sensors}, series = {Journal of Physical Chemistry C. 113 (2009), H. 33}, journal = {Journal of Physical Chemistry C. 113 (2009), H. 33}, publisher = {American Chemical Society}, address = {Washington, DC}, isbn = {1932-7455}, pages = {14765 -- 14770}, year = {2009}, language = {en} } @article{SchoeningBrinkmannRolkaetal.2005, author = {Sch{\"o}ning, Michael Josef and Brinkmann, D. and Rolka, David and Demuth, C. and Poghossian, Arshak}, title = {CIP (cleaning-in-place) suitable "non-glass" pH sensor based on a Ta2O5-gate EIS structure}, series = {Sensors and Actuators B: Chemical. 111-112 (2005)}, journal = {Sensors and Actuators B: Chemical. 111-112 (2005)}, isbn = {0925-4005}, pages = {423 -- 429}, year = {2005}, language = {en} } @article{TranStaat2013, author = {Tran, Thanh Ngoc and Staat, Manfred}, title = {An Edge-Based Smoothed Finite Element Method for Primal-Dual Shakedown Analysis of Structures Under Uncertainties}, series = {Limit State of Materials and Structures : Direct Methods 2. Saxc{\´e}, G{\´e}ry de (Hrsg.)}, journal = {Limit State of Materials and Structures : Direct Methods 2. Saxc{\´e}, G{\´e}ry de (Hrsg.)}, publisher = {Springer}, address = {Dordrecht}, isbn = {978-94-007-5424-9}, pages = {89 -- 102}, year = {2013}, language = {en} } @article{Digel2008, author = {Digel, Ilya}, title = {Controlling microbial adhesion : a surface engineering approach}, series = {Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.)}, journal = {Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.)}, publisher = {Springer}, address = {Berlin [u.a.]}, isbn = {978-3-540-75408-4}, pages = {601 -- 625}, year = {2008}, language = {en} } @article{PoghossianWernerBuniatyanetal.2017, author = {Poghossian, Arshak and Werner, Frederik and Buniatyan, V. V. and Wagner, Torsten and Miamoto, K. and Yoshinobu, T. and Sch{\"o}ning, Michael Josef}, title = {Towards addressability of light-addressable potentiometric sensors: Shunting effect of non-illuminated region and cross-talk}, series = {Sensor and Actuators B: Chemical}, journal = {Sensor and Actuators B: Chemical}, number = {244}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2017.01.047}, pages = {1071 -- 1079}, year = {2017}, abstract = {The LAPS (light-addressable potentiometric sensor) platform is one of the most attractive approaches for chemical and biological sensing with many applications ranging from pH and ion/analyte concentration measurements up to cell metabolism detection and chemical imaging. However, although it is generally accepted that LAPS measurements are spatially resolved, the light-addressability feature of LAPS devices has not been discussed in detail so far. In this work, an extended electrical equivalent-circuit model of the LAPS has been presented, which takes into account possible cross-talk effects due to the capacitive coupling of the non-illuminated region. A shunting effect of the non-illuminated area on the measured photocurrent and addressability of LAPS devices has been studied. It has been shown, that the measured photocurrent will be determined not only by the local interfacial potential in the illuminated region but also by possible interfacial potential changes in the non-illuminated region, yielding cross-talk effects. These findings were supported by the experimental investigations of a penicillin-sensitive multi-spot LAPS and a metal-insulator-semiconductor LAPS as model systems.}, language = {en} } @article{HasanKeilStaatetal.2012, author = {Hasan, Istabrak and Keil, Ludger and Staat, Manfred and Wahl, Gerhard and Bourauel, Christoph}, title = {Determination of the frictional coefficient of the implant-antler interface : experimental approach}, series = {Biomedical Engineering / Biomedizinische Technik}, volume = {57}, journal = {Biomedical Engineering / Biomedizinische Technik}, number = {5}, publisher = {De Gruyter}, address = {Berlin}, issn = {1862-278X}, pages = {359 -- 363}, year = {2012}, abstract = {The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5-0.7 and 0.3-0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens.}, language = {en} } @article{DemirciKurulganDemirciTrzewiketal.2009, author = {Demirci, Taylan and Kurulgan Demirci, Eylem and Trzewik, J{\"u}rgen and Linder, Peter and Digel, Ilya and Artmann, Gerhard and Sakizli, Meral and Temiz Artmann, Ayseg{\"u}l}, title = {Gene expression profile analysis of 3T3/NIH fibroblasts after one hour mechanical stress}, series = {IUBMB Life. 61 (2009), H. 3}, journal = {IUBMB Life. 61 (2009), H. 3}, publisher = {Wiley-VCH}, address = {Weinheim}, isbn = {1521-6543}, pages = {311 -- 312}, year = {2009}, language = {en} } @article{SchoeningPoghossian2008, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {Detection of charged macromolecules by means of field-effect devices (FEDs): possibilities and limitations}, series = {Electrochemical sensors, biosensors and their biomedical applications / ed. by Xueji Zhang ...}, journal = {Electrochemical sensors, biosensors and their biomedical applications / ed. by Xueji Zhang ...}, publisher = {Elsevier Acad. Press}, address = {Amsterdam}, isbn = {978-0-12-373738-0}, pages = {187 -- 212}, year = {2008}, language = {en} } @book{Laack2002, author = {Laack, Walter van}, title = {A better history of our world / Vol. 2. Life}, publisher = {van Laack}, address = {Aachen}, isbn = {978-3-8311-2597-5}, pages = {236 S.}, year = {2002}, language = {en} } @inproceedings{StaatSzelinskiHeitzer2001, author = {Staat, Manfred and Szelinski, E. and Heitzer, Michael}, title = {Kollapsanalyse von l{\"a}ngsfehlerbehafteten Rohren und Beh{\"a}ltern}, year = {2001}, abstract = {Es werden verbesserte Kollapsanalysen von dickwandigen, mit axialen Oberfl{\"a}chenfehlern behafteten Rohren und Beh{\"a}ltern vorgeschlagen.}, subject = {Druckbeh{\"a}lter}, language = {de} } @article{VoegeleJosyabhatlaBalletal.2023, author = {V{\"o}gele, Stefan and Josyabhatla, Vishnu Teja and Ball, Christopher and Rhoden, Imke and Grajewski, Matthias and R{\"u}bbelke, Dirk and Kuckshinrichs, Wilhelm}, title = {Robust assessment of energy scenarios from stakeholders' perspectives}, series = {Energy}, journal = {Energy}, number = {In Press, Article 128326}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-6785 (Online)}, doi = {10.1016/j.energy.2023.128326}, year = {2023}, abstract = {Using scenarios is vital in identifying and specifying measures for successfully transforming the energy system. Such transformations can be particularly challenging and require the support of a broader set of stakeholders. Otherwise, there will be opposition in the form of reluctance to adopt the necessary technologies. Usually, processes for considering stakeholders' perspectives are very time-consuming and costly. In particular, there are uncertainties about how to deal with modifications in the scenarios. In principle, new consulting processes will be required. In our study, we show how multi-criteria decision analysis can be used to analyze stakeholders' attitudes toward transition paths. Since stakeholders differ regarding their preferences and time horizons, we employ a multi-criteria decision analysis approach to identify which stakeholders will support or oppose a transition path. We provide a flexible template for analyzing stakeholder preferences toward transition paths. This flexibility comes from the fact that our multi-criteria decision aid-based approach does not involve intensive empirical work with stakeholders. Instead, it involves subjecting assumptions to robustness analysis, which can help identify options to influence stakeholders' attitudes toward transitions.}, language = {en} } @article{MolinnusBaeckerIkenetal.2015, author = {Molinnus, Denise and B{\"a}cker, Matthias and Iken, Heiko and Poghossian, Arshak and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Concept for a biomolecular logic chip with an integrated sensor and actuator function}, series = {Physica status solidi (a)}, volume = {212}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201431913}, pages = {1382 -- 1388}, year = {2015}, abstract = {A concept for a new generation of an integrated multi-functional biosensor/actuator system is developed, which is based on biomolecular logic principles. Such a system is expected to be able to detect multiple biochemical input signals simultaneously and in real-time and convert them into electrical output signals with logical operations such as OR, AND, etc. The system can be designed as a closed-loop drug release device triggered by an enzyme logic gate, while the release of the drug induced by the actuator at the required dosage and timing will be controlled by an additional drug sensor. Thus, the system could help to make an accurate and specific diagnosis. The presented concept is exemplarily demonstrated by using an enzyme logic gate based on a glucose/glucose oxidase system, a temperature-responsive hydrogel mimicking the actuator function and an insulin (drug) sensor. In this work, the results of functional testing of individual amperometric glucose and insulin sensors as well as an impedimetric sensor for the detection of the hydrogel swelling/shrinking are presented.}, language = {en} } @article{AyalaHarrisKleefeldetal.2023, author = {Ayala, Rafael Ceja and Harris, Isaac and Kleefeld, Andreas and Pallikarakis, Nikolaos}, title = {Analysis of the transmission eigenvalue problem with two conductivity parameters}, series = {Applicable Analysis}, journal = {Applicable Analysis}, publisher = {Taylor \& Francis}, issn = {0003-6811}, doi = {10.1080/00036811.2023.2181167}, pages = {37 Seiten}, year = {2023}, abstract = {In this paper, we provide an analytical study of the transmission eigenvalue problem with two conductivity parameters. We will assume that the underlying physical model is given by the scattering of a plane wave for an isotropic scatterer. In previous studies, this eigenvalue problem was analyzed with one conductive boundary parameter whereas we will consider the case of two parameters. We prove the existence and discreteness of the transmission eigenvalues as well as study the dependence on the physical parameters. We are able to prove monotonicity of the first transmission eigenvalue with respect to the parameters and consider the limiting procedure as the second boundary parameter vanishes. Lastly, we provide extensive numerical experiments to validate the theoretical work.}, language = {en} } @article{ChristiaensAbouzarPoghossianetal.2007, author = {Christiaens, P. and Abouzar, Maryam H. and Poghossian, Arshak and Wagner, Torsten and Bijnens, N. and Williams, O. A. and Daenen, M. and Haenen, K. and Douth{\´e}ret, O. and Haen, J. d´ and Mekhalif, Z. and Sch{\"o}ning, Michael Josef and Wagner, P.}, title = {pH sensitivity of nanocrystalline diamond films}, series = {Physica status solidi (A). 204 (2007), H. 9}, journal = {Physica status solidi (A). 204 (2007), H. 9}, isbn = {0031-8965}, pages = {2925 -- 2930}, year = {2007}, language = {en} } @article{WuPoghossianBronderetal.2016, author = {Wu, Chunsheng and Poghossian, Arshak and Bronder, Thomas and Sch{\"o}ning, Michael Josef}, title = {Sensing of double-stranded DNA molecules by their intrinsic molecular charge using the light-addressable potentiometric sensor}, series = {Sensors and Actuators B: Chemical}, journal = {Sensors and Actuators B: Chemical}, number = {229}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2016.02.004}, pages = {506 -- 512}, year = {2016}, abstract = {A multi-spot light-addressable potentiometric sensor (LAPS), which belongs to the family of semiconductor field-effect devices, was applied for label-free detection of double-stranded deoxyribonucleic acid (dsDNA) molecules by their intrinsic molecular charge. To reduce the distance between the DNA charge and sensor surface and thus, to enhance the electrostatic coupling between the dsDNA molecules and the LAPS, the negatively charged dsDNA molecules were electrostatically adsorbed onto the gate surface of the LAPS covered with a positively charged weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)). The surface potential changes in each spot of the LAPS, induced by the layer-by-layer adsorption of a PAH/dsDNA bilayer, were recorded by means of photocurrent-voltage and constant-photocurrent measurements. In addition, the surface morphology of the gate surface before and after consecutive electrostatic adsorption of PAH and dsDNA layers was studied by atomic force microscopy measurements. Moreover, fluorescence microscopy was used to verify the successful adsorption of dsDNA molecules onto the PAH-modified LAPS surface. A high sensor signal of 25 mV was registered after adsorption of 10 nM dsDNA molecules. The lower detection limit is down to 0.1 nM dsDNA. The obtained results demonstrate that the PAH-modified LAPS device provides a convenient and rapid platform for the direct label-free electrical detection of in-solution hybridized dsDNA molecules.}, language = {en} } @article{SchusserBaeckerKrischeretal.2014, author = {Schusser, Sebastian and B{\"a}cker, Matthias and Krischer, M. and Wenzel, L. and Leinhos, Marcel and Poghossian, Arshak and Biselli, Manfred and Wagner, P. and Sch{\"o}ning, Michael Josef}, title = {Enzymatically catalyzed degradation of biodegradable polymers investigated by means of a semiconductor-based field-effect sensor}, series = {Procedia Engineering}, volume = {87}, journal = {Procedia Engineering}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1877-7058}, doi = {10.1016/j.proeng.2014.11.689}, pages = {1314 -- 1317}, year = {2014}, abstract = {A semiconductor field-effect device has been used for an enzymatically catalyzed degradation of biopolymers for the first time. This novel technique is capable to monitor the degradation process of multiple samples in situ and in real-time. As model system, the degradation of the biopolymer poly(D, L-lactic acid) has been monitored in the degradation medium containing the enzyme lipase from Rhizomucor miehei. The obtained results demonstrate the potential of capacitive field-effect sensors for degradation studies of biodegradable polymers.}, language = {en} } @article{StulpeHellwig1983, author = {Stulpe, Werner and Hellwig, K.-E.}, title = {A Formulation of Quantum Stochastic Processes and Some of its Properties. Hellwig, K.-E.; Stulpe, W.}, series = {Foundations of Physics. 13 (1983), H. 7}, journal = {Foundations of Physics. 13 (1983), H. 7}, isbn = {1572-9516}, pages = {673 -- 699}, year = {1983}, language = {en} } @article{Staat2013, author = {Staat, Manfred}, title = {Limit and shakedown analysis under uncertainty}, series = {International journal of computational methods : IJCM}, journal = {International journal of computational methods : IJCM}, publisher = {World Scientific Publishing}, address = {Singapore}, issn = {0219-8762}, pages = {Publ. online}, year = {2013}, language = {en} } @book{Laack2001, author = {Laack, Walter van}, title = {A better history of our world / Vol. 1. The universe}, publisher = {van Laack}, address = {Aachen}, isbn = {978-3-8311-1490-0}, pages = {188 S.}, year = {2001}, language = {en} } @inproceedings{JungStaatMueller2014, author = {Jung, Alexander and Staat, Manfred and M{\"u}ller, Wolfram}, title = {Optimization of the flight style in ski jumping}, series = {11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20 - 25, 2014, Barcelona}, booktitle = {11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20 - 25, 2014, Barcelona}, editor = {Onate, E.}, organization = {World Congress on Computational Mechanics <11, 2014, Barcelona>}, pages = {799 -- 810}, year = {2014}, language = {en} } @article{PoghossianSchoening2014, author = {Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Label-free sensing of biomolecules with field-effect devices for clinical applications}, series = {Electroanalysis}, volume = {26}, journal = {Electroanalysis}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1521-4109 (E-Journal); 1040-0397 (Print)}, doi = {10.1002/elan.201400073}, pages = {1197 -- 1213}, year = {2014}, abstract = {Among the variety of transducer concepts proposed for label-free detection of biomolecules, the semiconductor field-effect device (FED) is one of the most attractive platforms. As medical techniques continue to progress towards diagnostic and therapies based on biomarkers, the ability of FEDs for a label-free, fast and real-time detection of multiple pathogenic and physiologically relevant molecules with high specificity and sensitivity offers very promising prospects for their application in point-of-care and personalized medicine for an early diagnosis and treatment of diseases. The presented paper reviews recent advances and current trends in research and development of different FEDs for label-free, direct electrical detection of charged biomolecules by their intrinsic molecular charge. The authors are mainly focusing on the detection of the DNA hybridization event, antibody-antigen affinity reaction as well as clinically relevant biomolecules such as cardiac and cancer biomarkers.}, language = {en} } @book{Laack2002, author = {Laack, Walter van}, title = {Eine bessere Geschichte unserer Welt / Bd. 3. Der Tod}, publisher = {van Laack}, address = {Aachen}, isbn = {978-3-8311-3581-3}, pages = {248 S.}, year = {2002}, language = {de} } @article{MolinnusPoghossianKeusgenetal.2017, author = {Molinnus, Denise and Poghossian, Arshak and Keusgen, Michael and Katz, Evgeny and Sch{\"o}ning, Michael Josef}, title = {Coupling of Biomolecular Logic Gates with Electronic Transducers: From Single Enzyme Logic Gates to Sense/Act/Treat Chips}, series = {Electroanalysis}, volume = {29}, journal = {Electroanalysis}, number = {8}, publisher = {Wiley}, address = {Weinheim}, issn = {1521-4109}, doi = {10.1002/elan.201700208}, pages = {1840 -- 1849}, year = {2017}, abstract = {The integration of biomolecular logic principles with electronic transducers allows designing novel digital biosensors with direct electrical output, logically triggered drug-release, and closed-loop sense/act/treat systems. This opens new opportunities for advanced personalized medicine in the context of theranostics. In the present work, we will discuss selected examples of recent developments in the field of interfacing enzyme logic gates with electrodes and semiconductor field-effect devices. Special attention is given to an enzyme OR/Reset logic gate based on a capacitive field-effect electrolyte-insulator-semiconductor sensor modified with a multi-enzyme membrane. Further examples are a digital adrenaline biosensor based on an AND logic gate with binary YES/NO output and an integrated closed-loop sense/act/treat system comprising an amperometric glucose sensor, a hydrogel actuator, and an insulin (drug) sensor.}, language = {en} } @article{AbouzarSchoeningPoghossianetal.2008, author = {Abouzar, Maryam H. and Sch{\"o}ning, Michael Josef and Poghossian, Arshak and Christiaens, P. and Williams, O. A. and Wagner, P. and Haenen, K.}, title = {Feldeffektsensor auf nanokristalliner Diamantbasis}, series = {Sensoren und Messsysteme 2008 : 14. Fachtagung Ludwigsburg, 11. und 12. M{\"a}rz 2008 / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik}, journal = {Sensoren und Messsysteme 2008 : 14. Fachtagung Ludwigsburg, 11. und 12. M{\"a}rz 2008 / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik}, publisher = {VDI-Verl.}, address = {D{\"u}sseldorf}, isbn = {978-3-18-092011-5}, pages = {549 -- 558}, year = {2008}, language = {de} } @inproceedings{StaatHeitzerHicken1998, author = {Staat, Manfred and Heitzer, M. and Hicken, E. F.}, title = {LISA, ein europ{\"a}isches Projekt zur direkten Berechnung der Tragf{\"a}higkeit duktiler Strukturen}, year = {1998}, abstract = {Traglast- und Einspielanalysen sind vereinfachte doch exakte Verfahren der Plastizit{\"a}t, die neben ausreichender Verformbarkeit keine einschr{\"a}nkenden Voraussetzungen beinhalten. Die Vereinfachungen betreffen die Beschaffung der Daten und Modelle f{\"u}r Details der Lastgeschichte und des Stoffverhaltens. Anders als die klassische Behandlung nichtlinearer Probleme der Strukturmechanik f{\"u}hrt die Methode auf Optimierungsprobleme. Diese sind bei realistischen FEM-Modellen sehr groß. Das hat die industrielle Anwendung der Traglast- und Einspielanalysen stark verz{\"o}gert. Diese Situation wird durch das Brite-EuRam Projekt LISA grundlegend ge{\"a}ndert. Die Autoren m{\"o}chten der Europ{\"a}ischen Kommission an dieser Stelle f{\"u}r die F{\"o}rderung ausdr{\"u}cklich danken. In LISA entsteht auf der Basis des industriellen FEM-Programms PERMAS ein Verfahren zur direkten Berechnung der Tragf{\"a}higkeit duktiler Strukturen. Damit kann der Betriebsbereich von Komponenten und Bauwerken auf den plastischen Bereich erweitert werden, ohne den Aufwand gegen{\"u}ber elastischen Analysen wesentlich zu erh{\"o}hen. Die beachtlichen Rechenzeitgewinne erlauben Parameterstudien und die Berechnung von Interaktionsdiagrammen, die einen schnellen {\"U}berblick {\"u}ber m{\"o}gliche Betriebsbereiche vermitteln. Es zeigt sich, daß abh{\"a}ngig von der Komponente und ihren Belastungen teilweise entscheidende Sicherheitsgewinne zur Erweiterung der Betriebsbereiche erzielt werden k{\"o}nnen. Das Vorgehen erfordert vom Anwender oft ein gewisses Umdenken. Es werden keine Spannungen berechnet, um damit Sicherheit und Lebensdauer zu interpretieren. Statt dessen berechnet man direkt die gesuchte Sicherheit. Der Post-Prozessor wird nur noch zur Modell- und Rechenkontrolle ben{\"o}tigt. Das Vorgehen ist {\"a}nhlich der Stabilit{\"a}tsanalyse (Knicken, Beulen). Durch namhafte industrielle Projektpartner werden Validierung und die Anwendbarkeit auf eine breite Palette technischer Probleme garantiert. Die ebenfalls in LISA geplante Zuverl{\"a}ssigkeitsanalyse ist erst auf der Basis direkter Verfahren effektiv m{\"o}glich. Ohne Traglast- und Einspielanalyse ist plastische Strukturoptimierung auch heute kaum durchf{\"u}hrbar.}, subject = {Finite-Elemente-Methode}, language = {de} } @inproceedings{PlatenPoghossianSchoening2006, author = {Platen, Johannes and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Microstructured Nanostructures - nanostructuring by means of conventional photolithography and layer-expansion technique}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-1477}, year = {2006}, abstract = {A new and simple method for nanostructuring using conventional photolithography and layer expansion or pattern-size reduction technique is presented, which can further be applied for the fabrication of different nanostructures and nano-devices. The method is based on the conversion of a photolithographically patterned metal layer to a metal-oxide mask with improved pattern-size resolution using thermal oxidation. With this technique, the pattern size can be scaled down to several nanometer dimensions. The proposed method is experimentally demonstrated by preparing nanostructures with different configurations and layouts, like circles, rectangles, trapezoids, "fluidic-channel"-, "cantilever"- and meander-type structures.}, subject = {Biosensor}, language = {en} } @article{KloockPoghossianSchumacheretal.2006, author = {Kloock, Joachim P. and Poghossian, Arshak and Schumacher, K. and Rosenkranz, C. and Schultze, J. W. and M{\"u}ller-Veggian, Mattea and Sch{\"o}ning, Michael Josef}, title = {Funktionspr{\"u}fung und Charakterisierung von ionensensitiven Feldeffekttransistoren (ISFETs) auf Waferebene mittels Mikrotropfenzelle f{\"u}r den zuk{\"u}nftigen Einsatz in der Sensorproduktion}, series = {Sensoren und Messsysteme 2006 : Vortr{\"a}ge der 13. ITG/GMA-Fachtagung vom 13. bis 14. M{\"a}rz 2006 in Freiburg/Breisgau / Veranst.: Informationstechnische Gesellschaft im VDE (ITG) ; VDE/VDI-Gesellschaft Mess- und Automatisierungstechnik (GMA). Wiss. Tagungsleitung: L. M. Reindl}, journal = {Sensoren und Messsysteme 2006 : Vortr{\"a}ge der 13. ITG/GMA-Fachtagung vom 13. bis 14. M{\"a}rz 2006 in Freiburg/Breisgau / Veranst.: Informationstechnische Gesellschaft im VDE (ITG) ; VDE/VDI-Gesellschaft Mess- und Automatisierungstechnik (GMA). Wiss. Tagungsleitung: L. M. Reindl}, publisher = {VDE-Verl.}, address = {Berlin}, isbn = {3-8007-2939-3}, pages = {257 -- 260}, year = {2006}, language = {de} } @incollection{SchoeningWagnerPoghossianetal.2018, author = {Sch{\"o}ning, Michael Josef and Wagner, Torsten and Poghossian, Arshak and Miyamoto, K.I. and Werner, C.F. and Krause, S. and Yoshinobu, T.}, title = {Light-addressable potentiometric sensors for (bio-)chemical sensing and imaging}, series = {Encyclopedia of Interfacial Chemistry: Surface Science and Electrochemistry. Vol. 7}, booktitle = {Encyclopedia of Interfacial Chemistry: Surface Science and Electrochemistry. Vol. 7}, publisher = {Elsevier}, address = {Amsterdam}, isbn = {9780128097397}, pages = {295 -- 308}, year = {2018}, language = {en} } @article{PoghossianYoshinobuSimonisetal.2001, author = {Poghossian, Arshak and Yoshinobu, Tatsuo and Simonis, A. and Ecken, H. and L{\"u}th, Hans and Sch{\"o}ning, Michael Josef}, title = {Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS?}, series = {Sensors and Actuators B. 78 (2001), H. 1-3}, journal = {Sensors and Actuators B. 78 (2001), H. 1-3}, isbn = {0925-4005}, pages = {237 -- 242}, year = {2001}, language = {en} } @inproceedings{SchoeningAbouzarHanetal.2006, author = {Sch{\"o}ning, Michael Josef and Abouzar, Maryam H. and Han, Y. and Ingebrandt, S. and Offenh{\"a}usser, A. and Poghossian, Arshak}, title = {Markierungsfreie DNA-Detektion mit Silizium-Feldeffektsensoren - Messeffekte oder Artefakte?}, series = {Sensoren und Mess-Systeme 2006 : Vortr{\"a}ge der 13. ITG/GMA-Fachtagung vom 13. bis 14.3.2006 in Freiburg/Breisgau}, booktitle = {Sensoren und Mess-Systeme 2006 : Vortr{\"a}ge der 13. ITG/GMA-Fachtagung vom 13. bis 14.3.2006 in Freiburg/Breisgau}, publisher = {VDE Verl.}, address = {Berlin}, isbn = {3-8007-2939-3}, pages = {443 -- 446}, year = {2006}, language = {de} } @article{PoghossianSchoening2007, author = {Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {Chemical and biological field-effect sensors for liquids - a status report}, series = {Handbook of biosensors and biochips / ed. Robert S. Marks ... Bd. 1}, journal = {Handbook of biosensors and biochips / ed. Robert S. Marks ... Bd. 1}, publisher = {Wiley}, address = {Chichester}, isbn = {978-0-470-01905-4}, pages = {395 -- 412}, year = {2007}, language = {en} } @article{StaatHeitzer1999, author = {Staat, Manfred and Heitzer, M.}, title = {FEM-computation of load carrying capacity of highly loaded passive components by direct methods. Heitzer, M. ; Staat, M.}, series = {Nuclear Engineering and Design. 193 (1999), H. 3}, journal = {Nuclear Engineering and Design. 193 (1999), H. 3}, isbn = {0029-5493}, pages = {349 -- 358}, year = {1999}, language = {en} } @inproceedings{StaatHeitzerReindersetal.2001, author = {Staat, Manfred and Heitzer, Michael and Reinders, H. and Schubert, F.}, title = {Einspielen und Ratchetting bei Zug- und Torsionsbelastung: Analyse und Experimente}, year = {2001}, abstract = {Traglast- und Einspielanalysen sind vereinfachte doch exakte Verfahren der klassischen Plastizit{\"a}tstheorie, die neben ausreichender Verformbarkeit keine einschr{\"a}nkenden Voraussetzungen beinhalten. Die Vereinfachungen betreffen die Beschaffung der Daten und Modelle f{\"u}r Details der Lastgeschichte und des Stoffverhaltens. Eine FEM-basierte Traglast- und Einspielanalyse f{\"u}r ideal plastisches Material wurde auf ein kinematisch verfestigendes Materialgesetz erweitert und in das Finite Element Programm PERMAS implementiert. In einem einfachen Zug-Torsionsexperiment wurde eine Hohlprobe mit konstanter Torsion und zyklischer Zugbelastung beansprucht, um die neue Implementierung zu verifizieren. Es konnte gezeigt werden, dass die Einspielanalyse gut mit den experimentellen Ergebnissen {\"u}bereinstimmt. Bei Verfestigung lassen sich wesentlich gr{\"o}ßere Sicherheiten nachweisen. Dieses Potential bedarf weiterer experimenteller Absicherung. Parallel dazu ist die Eisnpieltheorie auf fortschrittliche Verfestigungsans{\"a}tze zu erweitern.}, subject = {Zug-Druck-Beanspruchung}, language = {de} } @article{PoghossianWeilCherstvyetal.2013, author = {Poghossian, Arshak and Weil, M. and Cherstvy, A. G. and Sch{\"o}ning, Michael Josef}, title = {Electrical monitoring of polyelectrolyte multilayer formation by means of capacitive field-effect devices}, series = {Analytical and bioanalytical chemistry}, volume = {405}, journal = {Analytical and bioanalytical chemistry}, number = {20}, publisher = {Springer}, address = {Berlin}, issn = {1432-1130 ; 1618-2642}, doi = {10.1007/s00216-013-6951-9}, pages = {6425 -- 6436}, year = {2013}, abstract = {The semiconductor field-effect platform represents a powerful tool for detecting the adsorption and binding of charged macromolecules with direct electrical readout. In this work, a capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensor consisting of an Al-p-Si-SiO2 structure has been applied for real-time in situ electrical monitoring of the layer-by-layer formation of polyelectrolyte (PE) multilayers (PEM). The PEMs were deposited directly onto the SiO2 surface without any precursor layer or drying procedures. Anionic poly(sodium 4-styrene sulfonate) and cationic weak polyelectrolyte poly(allylamine hydrochloride) have been chosen as a model system. The effect of the ionic strength of the solution, polyelectrolyte concentration, number and polarity of the PE layers on the characteristics of the PEM-modified EIS sensors have been studied by means of capacitance-voltage and constant-capacitance methods. In addition, the thickness, surface morphology, roughness and wettabilityof the PE mono- and multilayers have been characterised by ellipsometry, atomic force microscopy and water contact-angle methods, respectively. To explain potential oscillations on the gate surface and signal behaviour of the capacitive field-effect EIS sensor modified with a PEM, a simplified electrostatic model that takes into account the reduced electrostatic screening of PE charges by mobile ions within the PEM has been proposed and discussed.}, language = {en} } @article{SchoeningPoghossian2002, author = {Sch{\"o}ning, Michael Josef and Poghossian, Arshak}, title = {Recent advances in biologically sensitive field-effect transistors (BioFETs)}, series = {Analyst. 127 (2002)}, journal = {Analyst. 127 (2002)}, isbn = {0003-2654}, pages = {1137 -- 1151}, year = {2002}, language = {en} } @article{Staat1991, author = {Staat, Manfred}, title = {Versagenswahrscheinlichkeit der Prim{\"a}rkreisdruckumschließung eines HTR-Moduls zur Prozeßw{\"a}rmegewinnung unter St{\"o}rfallbedingungen}, series = {Jahrestagung Kerntechnik '91 / Kerntechnische Gesellschaft e.V. ; Deutsches Atomforum e.V}, journal = {Jahrestagung Kerntechnik '91 / Kerntechnische Gesellschaft e.V. ; Deutsches Atomforum e.V}, publisher = {INFORUM}, address = {Bonn}, pages = {123 -- 126}, year = {1991}, language = {de} } @inproceedings{WuBronderPoghossianetal.2014, author = {Wu, Chunsheng and Bronder, Thomas and Poghossian, Arshak and Sch{\"o}ning, Michael Josef}, title = {DNA-hybridization detection using light-addressable potentiometric sensor modified with gold layer}, series = {Sensoren und Messsysteme 2014 ; Beitr{\"a}ge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in N{\"u}rnberg. (ITG-Fachbericht ; 250)}, booktitle = {Sensoren und Messsysteme 2014 ; Beitr{\"a}ge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in N{\"u}rnberg. (ITG-Fachbericht ; 250)}, publisher = {VDE-Verl.}, address = {D{\"u}sseldorf}, organization = {VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik}, isbn = {978-3-8007-3622-5}, pages = {1 -- 4}, year = {2014}, language = {en} } @inproceedings{HuckPoghossianBuniatyanetal.2014, author = {Huck, Christina and Poghossian, Arshak and Buniatyan, V. and Sch{\"o}ning, Michael Josef}, title = {Multi-parameter detection for supporting monitoring and control of biogas processes in agriculture}, series = {Sensoren und Messsysteme 2014 ; Beitr{\"a}ge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in N{\"u}rnberg. (ITG-Fachbericht ; 250)}, booktitle = {Sensoren und Messsysteme 2014 ; Beitr{\"a}ge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in N{\"u}rnberg. (ITG-Fachbericht ; 250)}, publisher = {VDE-Verl.}, address = {Berlin}, organization = {VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik}, isbn = {978-3-8007-3622-5}, pages = {1 -- 5}, year = {2014}, language = {en} }