@article{KruegerGroetzingerBerndt1987, author = {Kr{\"u}ger, G{\"o}tz and Gr{\"o}tzinger, Joachim and Berndt, Heinz}, title = {Enantiomeric resolution of amino acid derivatives on chiral stationary phases by high-performance liquid chromatography}, series = {Journal of Chromatography A}, volume = {1987}, journal = {Journal of Chromatography A}, number = {397}, issn = {0021-9673}, doi = {10.1016/S0021-9673(01)85005-6}, pages = {223 -- 232}, year = {1987}, language = {en} } @misc{StaubTippkoetterSucketal.2009, author = {Staub, C. and Tippk{\"o}tter, Nils and Suck, K. and Ruf, F. and Sohling, U. and Ulber, Roland}, title = {Aufreinigung von Molkeproteinen mittels nat{\"u}rlicher Adsorbermaterialien}, series = {Chemie Ingenieur Technik}, volume = {81}, journal = {Chemie Ingenieur Technik}, number = {8}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0009-286X}, doi = {10.1002/cite.200950310}, pages = {1299}, year = {2009}, abstract = {Molke als Nebenprodukt der K{\"a}seherstellung wurde lange Zeit als Abfall betrachtet. Bedingt durch ihren hohen BOD (biological oxygen demand) war die direkte Einleitung in Gew{\"a}sser, aber auch der mikrobielle Abbau in Kl{\"a}ranlagen bedenklich. Falls eine Weiterverarbeitung der Molke stattfand, so geschah dies meist zu Molkepulver oder Proteinkonzentrat. Als Untersuchungen der Molkeproteine jedoch unter pharmazeutischen Gesichtspunkten interessante Eigenschaften nahelegten, stieg das Interesse am Bioprodukt Molke und ihren Proteinen an. So stehen beispielsweise f{\"u}r die Molkeproteine a-Lactalbumin (ala) und b-Lactoglobulin (blg) antibakterielle, anticancerogene und diverse andere physiologische Effekte in der Diskussion. Gegenw{\"a}rtig finden meist Membranverfahren zur Aufreinigung von Molkeproteinen Anwendung. Als alternatives Verfahren wurde am Institut f{\"u}r Bioverfahrenstechnik in Kaiserslautern ein chromatographisches Verfahren entwickelt, bei dem nat{\"u}rliche Tonminerale zum Einsatz kamen. Nach chemischer und physikalischer Modifikation des Ausgangsmaterials durch den Hersteller S{\"u}d-Chemie wurden drei der Adsorber f{\"u}r n{\"a}here Untersuchungen zur Auftrennung von Molkeproteinen aus Molkekonzentrat herangezogen. Nach einer Cross-Flow-Filtration des Molkekonzentrats erfolgte die Aufreinigung der Molkeproteine in einem FPLC-System.}, language = {de} } @article{WangAnikFrohberg1988, author = {Wang, Mao and Anik, Sabri and Frohberg, Martin G.}, title = {Experiments on the electrochemical determination of the sulphur activities in the system copper-silver at 1200°C}, series = {Zeitschrift f{\"u}r Metallkunde}, volume = {79}, journal = {Zeitschrift f{\"u}r Metallkunde}, number = {5}, issn = {0044-3093}, pages = {336 -- 339}, year = {1988}, language = {en} } @article{FontiEilmannGarciaGonzalezetal.2009, author = {Fonti, Patrick and Eilmann, Britta and Garc{\´i}a-Gonz{\´a}lez, Ignacio and von Arx, Georg}, title = {Expeditious building of ring-porous earlywood vessel chronologies without loosing signal information}, series = {Trees : structure and function}, volume = {23}, journal = {Trees : structure and function}, number = {3}, publisher = {Springer}, address = {Berlin}, issn = {0931-1890 (Print)}, doi = {10.1007/s00468-008-0310-z}, pages = {665 -- 671}, year = {2009}, language = {en} } @misc{Huening2023, author = {H{\"u}ning, Felix}, title = {Sensorvorrichtung zur Erfassung eines Magnetfelds sowie magnetbasiertes Sensorsystem zur Erfassung einer Bewegung eines beweglichen Objekts}, year = {2023}, abstract = {Eine Sensorvorrichtung (10;110;210;310;410) zur Erfassung eines Magnetfelds, mit einer Wiegand-Sensoreinheit (12;112;212) umfassend: • - mindestens zwei Wiegand-Dr{\"a}hte (20) und • - eine Spulenanordnung (22;122;222), die die mindestens zwei Wiegand-Dr{\"a}hte (20) radial umschließt und die • • • ein Sensorelement (26;126;226) und • • ein Triggerelement (28;128;228), durch das ein Triggermagnetfeld erzeugbar ist, bildet, ist bekannt. Um ein magnetbasiertes Sensorsystem (300;400) zur Erfassung einer Bewegung eines beweglichen Objekts (301;401) zu erm{\"o}glichen, das ohne externe Energieversorgung zuverl{\"a}ssig sowie energieeffizient arbeitet und kosteng{\"u}nstig hergestellt werden kann, ist bei der erfindungsgem{\"a}ßen Sensorvorrichtung (10;110;210;310;410) eine Wiegand-Triggereinheit (14;14a) vorhanden, umfassend: • - einen Wiegand-Draht (30) und • - eine Trigger-Sensorspule (32), die den Wiegand-Draht (30) radial umschließt, wobei ein erstes Ende der Trigger-Sensorspule (32) der Wiegand-Triggereinheit (14;14a) mit einem ersten Ende des Triggerelements (28;128;228) der Wiegand-Sensoreinheit (12;112;212) elektrisch verbunden ist und ein zweites Ende der Trigger-Sensorspule (32) der Wiegand-Triggereinheit (14;14a) mit einem zweiten Ende des Triggerelements (28;128;228) der Wiegand-Sensoreinheit (12;112;212) elektrisch verbunden ist. Auf diese Weise verst{\"a}rkt ein in der Trigger-Sensorspule (32) erzeugter Impuls das Gesamtmagnetfeld, das auf die Wiegand-Dr{\"a}hte (20) in der Sensoreinheit einwirkt, derart, dass die Triggefeldst{\"a}rke aller Wiegand-Dr{\"a}hte (20) {\"u}berschritten wird und diese im wesentlichen zeitgleich ausl{\"o}sen.}, language = {de} }