@inproceedings{SchoeningAbdelghani2012, author = {Sch{\"o}ning, Michael Josef and Abdelghani, Adnane}, title = {Nanoscale Science and Technology (NS\&T'12) : Proceedings Book Humboldt Kolleg <2012, Tunisia> ; Tunisia, 17-19 March, 2012 / ed. by Michael J. Sch{\"o}ning ; Adnane Abdelghani}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:a96-opus-3544}, year = {2012}, abstract = {Proceedings of the 2nd Humboldt Kolleg, Hammamet, Tunisia Organizer: Alexander von Humboldt Stiftung, Germany. pdf 184 p. Welcome Address Dear Participants, Welcome to the 2nd Humboldt Kolleg in "Nanoscale Science and Technology" (NS\&T'12) in Tunisia, sponsored by the "Alexander von Humboldt" foundation. The NS\&T'12 multidisciplinary scientific program includes seven "hot" topics dealing with "Nanoscale Science and Technology" covering basic and application-oriented research as well as industrial (market) aspects: - Molecular Biophyics, Spectroscopy Techniques, Imaging Microscopy - Nanomaterials Synthesis for Medicine and Bio-chemical Sensors - Nanostructures, Semiconductors, Photonics and Nanodevices - New Technologies in Market Industry - Environment, Electro-chemistry, Bio-polymers and Fuel Cells - Nanomaterials, Photovoltaic, Modelling, Quantum Physics - Microelectronics, Sensors Networks and Embedded Systems We are deeply indebted to all members of the Scientific Committee and General Chairs for joint Sessions and to all speakers and chairmen, who have dedicated invaluable time and efforts for the realization of this event. On behalf of the Organizing Committee, we are cordially inviting you to join the conference and hope that your stay will be fruitful, rewarding and enjoyable. Prof. Dr. Michael J. Sch{\"o}ning, Prof. Dr. Adnane Abdelghani}, subject = {Biosensor}, language = {en} } @article{WernerWagnerMiyamotoetal.2012, author = {Werner, Frederik and Wagner, Torsten and Miyamoto, Ko-ichiro and Yoshinobu, Tatsuo and Sch{\"o}ning, Michael Josef}, title = {High speed and high resolution chemical imaging based on a new type of OLED-LAPS set-up}, series = {Sensors and Actuators B: Chemical}, volume = {175}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2011.12.102}, pages = {118 -- 122}, year = {2012}, abstract = {Light-addressable potentiometric sensors (LAPS) are field-effect-based sensors. A modulated light source is used to define the particular measurement spot to perform spatially resolved measurements of chemical species and to generate chemical images. In this work, an organic-LED (OLED) display has been chosen as a light source. This allows high measurement resolution and miniaturisation of the system. A new developed driving method for the OLED display optimised for LAPS-based measurements is demonstrated. The new method enables to define modulation frequencies between 1 kHz and 16 kHz and hence, reduces the measurement time of a chemical image by a factor of 40 compared to the traditional addressing of an OLED display.}, language = {en} } @article{WagnerWernerMiyamotoetal.2012, author = {Wagner, Torsten and Werner, Frederik and Miyamoto, Ko-Ichiro and Sch{\"o}ning, Michael Josef and Yoshinobu, Tatsuo}, title = {Development and characterisation of a compact light-addressable potentiometric sensor (LAPS) based on the digital light processing (DLP) technology for flexible chemical imaging}, series = {Sensors and Actuators B: Chemical}, volume = {170}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2010.12.003}, pages = {34 -- 39}, year = {2012}, abstract = {Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach to read out light-addressable potentiometric sensors (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device, which allows fast and flexible generation of light patterns. With the help of these light patterns, the sensor surface of the LAPS device can be addressed. The DLP approach has several advantages compared to conventional LAPS set-ups, e.g., the spot size and the shape of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of the measurement. In addition, the modulation frequency and intensity of the light beam are important parameters of the LAPS set-up. Within this work, the authors will discuss two different ways of light modulation by the DLP set-up, investigate the influence of different modulation frequencies and different light intensities as well as demonstrate the scanning capabilities of the new set-up by pH mapping on the sensor surface.}, language = {en} } @article{GrinsvenBonStrauvenetal.2012, author = {Grinsven, Bart van and Bon, Natalie vanden and Strauven, Hannelore and Grieten, Lars and Murib, Mohammed and Jim{\´e}nez Monroy, Kathia L. and Janssens, Stoffel D. and Haenen, Ken and Sch{\"o}ning, Michael Josef and Vermeeren, Veronique and Ameloot, Marcel and Michiels, Luc and Thoelen, Ronald and Ceuninck, Ward de and Wagner, Patrick}, title = {Heat-Transfer Resistance at Solid-Liquid Interfaces: A Tool for The Detection of Single Nucleotide Polymorphisms in DNA.}, series = {ACS Nano}, volume = {6}, journal = {ACS Nano}, number = {3}, publisher = {ACS Publications}, address = {Washington, DC}, issn = {1936-086X}, doi = {10.1021/nn300147e}, pages = {2712 -- 2721}, year = {2012}, abstract = {In this article, we report on the heat-transfer resistance at interfaces as a novel, denaturation-based method to detect single-nucleotide polymorphisms in DNA. We observed that a molecular brush of double-stranded DNA grafted onto synthetic diamond surfaces does not notably affect the heat-transfer resistance at the solid-to-liquid interface. In contrast to this, molecular brushes of single-stranded DNA cause, surprisingly, a substantially higher heat-transfer resistance and behave like a thermally insulating layer. This effect can be utilized to identify ds-DNA melting temperatures via the switching from low- to high heat-transfer resistance. The melting temperatures identified with this method for different DNA duplexes (29 base pairs without and with built-in mutations) correlate nicely with data calculated by modeling. The method is fast, label-free (without the need for fluorescent or radioactive markers), allows for repetitive measurements, and can also be extended toward array formats. Reference measurements by confocal fluorescence microscopy and impedance spectroscopy confirm that the switching of heat-transfer resistance upon denaturation is indeed related to the thermal on-chip denaturation of DNA.}, language = {en} } @article{AbouzarPoghossianCherstvyetal.2012, author = {Abouzar, Maryam H. and Poghossian, Arshak and Cherstvy, Andrey G. and Pedraza, Angela M. and Ingebrandt, Sven and Sch{\"o}ning, Michael Josef}, title = {Label-free electrical detection of DNA by means of field-effect nanoplate capacitors: Experiments and modeling}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100710}, pages = {925 -- 934}, year = {2012}, abstract = {Label-free electrical detection of consecutive deoxyribonucleic acid (DNA) hybridization/denaturation by means of an array of individually addressable field-effect-based nanoplate silicon-on-insulator (SOI) capacitors modified with gold nanoparticles (Au-NP) is investigated. The proposed device detects charge changes on Au-NP/DNA hybrids induced by the hybridization or denaturation event. DNA hybridization was performed in a high ionic-strength solution to provide a high hybridization efficiency. On the other hand, to reduce the screening of the DNA charge by counter ions and to achieve a high sensitivity, the sensor signal induced by the hybridization and denaturation events was measured in a low ionic-strength solution. High sensor signals of about 120, 90, and 80 mV were registered after the DNA hybridization, denaturation, and re-hybridization events, respectively. Fluorescence microscopy has been applied as reference method to verify the DNA immobilization, hybridization, and denaturation processes. An electrostatic charge-plane model for potential changes at the gate surface of a nanoplate field-effect sensor induced by the DNA hybridization has been developed taking into account both the Debye length and the distance of the DNA charge from the gate surface.}, language = {en} } @inproceedings{YoshinobuMiyamotoWagneretal.2012, author = {Yoshinobu, Tatsuo and Miyamoto, Ko-Ichiro and Wagner, Torsten and Sch{\"o}ning, Michael Josef}, title = {Miniaturized and high-speed chemical imaging systems}, series = {Nano-Biomedical Engineering 2012. Proceedings of the Tohoku University Global Centre of Excellence Programme, Sakura Hall, Tohoku University, Sendai Japan, 5 - 6 March 2012}, booktitle = {Nano-Biomedical Engineering 2012. Proceedings of the Tohoku University Global Centre of Excellence Programme, Sakura Hall, Tohoku University, Sendai Japan, 5 - 6 March 2012}, editor = {Yamaguchi, Takami}, publisher = {World Scientific}, address = {Singapur}, doi = {10.1142/9781848169067_0045}, pages = {386 -- 395}, year = {2012}, language = {en} } @article{BaeckerRaueSchusseretal.2012, author = {B{\"a}cker, Matthias and Raue, Markus and Schusser, Sebastian and Jeitner, C. and Breuer, L. and Wagner, P. and Poghossian, Arshak and F{\"o}rster, Arnold and Mang, Thomas and Sch{\"o}ning, Michael Josef}, title = {Microfluidic chip with integrated microvalves based on temperature- and pH-responsive hydrogel thin films}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100763}, pages = {839 -- 845}, year = {2012}, abstract = {Two types of microvalves based on temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm) and pH-responsive poly(sodium acrylate) (PSA) hydrogel films have been developed and tested. The PNIPAAm and PSA hydrogel films were prepared by means of in situ photopolymerization directly inside the fluidic channel of a microfluidic chip fabricated by combining Si and SU-8 technologies. The swelling/shrinking properties and height changes of the PNIPAAm and PSA films inside the fluidic channel were studied at temperatures of deionized water from 14 to 36 °C and different pH values (pH 3-12) of Titrisol buffer, respectively. Additionally, in separate experiments, the lower critical solution temperature (LCST) of the PNIPAAm hydrogel was investigated by means of a differential scanning calorimetry (DSC) and a surface plasmon resonance (SPR) method. Mass-flow measurements have shown the feasibility of the prepared hydrogel films to work as an on-chip integrated temperature- or pH-responsive microvalve capable to switch the flow channel on/off.}, language = {en} } @article{SpelthahnSchubertSchoening2012, author = {Spelthahn, Heiko and Schubert, J{\"u}rgen and Sch{\"o}ning, Michael Josef}, title = {D{\"u}nnschichtsensoren f{\"u}r die Schwermetallanalytik}, series = {GIT : Labor-Fachzeitschrift}, volume = {56}, journal = {GIT : Labor-Fachzeitschrift}, number = {4}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {0016-3538}, pages = {285 -- 287}, year = {2012}, abstract = {Die Detektion von Schadstoffen repr{\"a}sentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte D{\"u}nnschichtsensoren bieten eine kosteng{\"u}nstige M{\"o}glichkeit, „online"-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuf{\"u}hren. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgl{\"a}sern zur Detektion von Schwermetallen in w{\"a}ssrigen Medien vorgestellt.}, language = {en} } @article{WernerGroebelKrumbeetal.2012, author = {Werner, Frederik and Groebel, Simone and Krumbe, Christoph and Wagner, Torsten and Selmer, Thorsten and Yoshinobu, Tatsuo and Baumann, Marcus and Sch{\"o}ning, Michael Josef}, title = {Nutrient concentration-sensitive microorganism-based biosensor}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100801}, pages = {900 -- 904}, year = {2012}, language = {en} } @article{KirchnerReisertPuetzetal.2012, author = {Kirchner, Patrick and Reisert, Steffen and P{\"u}tz, Patrick and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Characterisation of polymeric materials as passivation layer for calorimetric H2O2 gas sensors}, series = {Physica Status Solidi (a)}, volume = {209}, journal = {Physica Status Solidi (a)}, number = {5}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201100773}, pages = {859 -- 863}, year = {2012}, abstract = {Calorimetric gas sensors for monitoring the H₂O₂ concentration at elevated temperatures in industrial sterilisation processes have been presented in previous works. These sensors are built up in form of a differential set-up of a catalytically active and passive temperature-sensitive structure. Although, various types of catalytically active dispersions have been studied, the passivation layer has to be established and therefore, chemically as well as physically characterised. In the present work, fluorinated ethylene propylene (FEP), perfluoralkoxy (PFA) and epoxy-based SU-8 photoresist as temperature-stable polymeric materials have been investigated for sensor passivation in terms of their chemical inertness against H₂O₂, their hygroscopic properties as well as their morphology. The polymeric materials were deposited via spin-coating on the temperature-sensitive structure, wherein spin-coated FEP and PFA show slight agglomerates. However, they possess a low absorption of humidity due to their hydrophobic surface, whereas the SU-8 layer has a closed surface but shows a slightly higher absorption of water. All of them were inert against gaseous H₂O₂ during the characterisation in H₂O₂ atmosphere that demonstrates their suitability as passivation layer for calorimetric H₂O₂ gas sensors.}, language = {en} }