@article{HacklKahmannWegmannetal.2016, author = {Hackl, Michael and Kahmann, Stephanie Lucina and Wegmann, Kilian and Ries, Christian and Staat, Manfred and M{\"u}ller, Lars-Peter}, title = {Shortening osteotomy of the proximal radius — a treatment option for isolated osteoarthritis of the lateral column of the elbow joint?}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4080-7}, pages = {128 -- 129}, year = {2016}, abstract = {Treatment of posttraumatic osteoarthritis of the radial column of the elbow joint remains a challenging yet common issue. While partial joint replacement leads to high revision rates, radial head excision has shown to severely increase joint instability. Shortening osteotomy of the radius could be an option to decrease the contact pressure of the radiohumeral joint and thereby pain levels without causing valgus instability. Hence, the aim of this biomechanical study was to evaluate the effects of radial shortening on axial load distribution and valgus stability of the elbow joint.}, language = {en} } @article{HacklLeschingerStaatetal.2016, author = {Hackl, Michael and Leschinger, T. and Staat, Manfred and M{\"u}ller, Lars-Peter and Wegmann, Kilian}, title = {Reconstruction of the interosseous membrane in the Essex Lopresti lesion — a biomechanical evaluation}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4080-7}, pages = {130 -- 131}, year = {2016}, abstract = {Surgical reconstruction of the interosseous membrane (IOM) could restore longitudinal forearm stability to avoid persisting disability due to capituloradial and ulnocarpal impingement in Essex Lopresti lesions. This biomechanical study aimed to assess longitudinal forearm stability of intact specimens, after sectioning of the IOM and after reconstruction with a TightRope construct using either a single or double bundle technique.}, language = {en} } @article{WegmannHacklStaatetal.2016, author = {Wegmann, Kilian and Hackl, Michael and Staat, Manfred and Mayer, Katharina and M{\"u}ller, Lars-Peter}, title = {Double plate osteosynthesis of proximal ulna fractures: biomechanical and clinical results}, series = {Knee surgery, sports traumatology, arthroscopy}, volume = {Volume 24}, journal = {Knee surgery, sports traumatology, arthroscopy}, number = {Supplement 1}, publisher = {Springer}, address = {Berlin}, issn = {0942-2056}, doi = {10.1007/s00167-016-4079-0}, pages = {58 -- 59}, year = {2016}, abstract = {While plate fixation of proximal ulna fractures might lead to superior clinical results compared to tension band wiring, regular plates represent an established risk factor for wound complications. The olecranon double plates (Medartis, Basel, CH) might decrease complications related to the osteosynthesis because of their low profile and better anatomical fit. This study aimed to evaluate the biomechanical performance and clinical results of the olecranon double plates.}, language = {en} } @article{Wollert2016, author = {Wollert, J{\"o}rg}, title = {Rapid Application Development}, series = {Design \& Elektronik}, journal = {Design \& Elektronik}, number = {4}, publisher = {WEKA-Fachmedien}, address = {M{\"u}nchen}, issn = {0933-8667}, pages = {8 -- 11}, year = {2016}, abstract = {Das IoT ist ohne eingebettete Systeme undenkbar. Erst kleine und kleinste Mikrocontroller mit intelligenten Kommunikationsschnittstellen und Anbindung ans Internet erm{\"o}glichen sinnvolles und fl{\"a}chendeckendes Einsammeln von Daten. Doch wie kompliziert ist der Einstieg in die Embedded-Welt? Dieser Artikel gibt Einblick, wie die »Arduino-Plattform« die Einstiegsh{\"u}rden f{\"u}r eingebettete Systeme dramatisch reduzieren kann.}, language = {de} } @article{Wollert2016, author = {Wollert, J{\"o}rg}, title = {Industrial Internet of Things : Seifenblase oder Revolution}, series = {Elektronik}, journal = {Elektronik}, number = {7}, publisher = {WEKA-Fachmedien}, address = {M{\"u}nchen}, issn = {0013-5658}, pages = {39 -- 45}, year = {2016}, language = {de} } @article{BreuerRaueStrobeletal.2016, author = {Breuer, Lars and Raue, Markus and Strobel, M. and Mang, Thomas and Sch{\"o}ning, Michael Josef and Thoelen, R. and Wagner, Torsten}, title = {Hydrogels with incorporated graphene oxide as light-addressable actuator materials for cell culture environments in lab-on-chip systems}, series = {Physica status solidi (a)}, volume = {213}, journal = {Physica status solidi (a)}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6300}, doi = {10.1002/pssa.201533056}, pages = {1520 -- 1525}, year = {2016}, abstract = {Abstractauthoren Graphene oxide (GO) nanoparticles were incorporated in temperature-sensitive Poly(N-isopropylacrylamide) (PNIPAAm) hydrogels. The nanoparticles increase the light absorption and convert light energy into heat efficiently. Thus, the hydrogels with GO can be stimulated spatially resolved by illumination as it was demonstrated by IR thermography. The temporal progression of the temperature maximum was detected for different concentrations of GO within the polymer network. Furthermore, the compatibility of PNIPAAm hydrogels with GO and cell cultures was investigated. For this purpose, culture medium was incubated with hydrogels containing GO and the viability and morphology of chinese hamster ovary (CHO) cells was examined after several days of culturing in presence of this medium.}, language = {en} } @article{PookhalilAmoabedinyTabeshetal.2016, author = {Pookhalil, Ali and Amoabediny, Ghassem and Tabesh, Hadi and Behbahani, Mehdi and Mottaghy, Khosrow}, title = {A new approach for semiempirical modeling of mechanical blood trauma}, series = {The international journal of artificial organs}, volume = {39}, journal = {The international journal of artificial organs}, number = {4}, publisher = {Sage}, address = {London}, issn = {1724-6040}, doi = {10.5301/ijao.5000474}, pages = {171 -- 177}, year = {2016}, abstract = {Purpose Two semi-empirical models were recently published, both making use of existing literature data, but each taking into account different physical phenomena that trigger hemolysis. In the first model, hemoglobin (Hb) release is described as a permeation procedure across the membrane, assuming a shear stress-dependent process (sublethal model). The second model only accounts for hemoglobin release that is caused by cell membrane breakdown, which occurs when red blood cells (RBC) undergo mechanically induced shearing for a period longer than the threshold time (nonuniform threshold model). In this paper, we introduce a model that considers the hemolysis generated by both these possible phenomena. Methods Since hemolysis can possibly be caused by permeation of hemoglobin through the RBC functional membrane as well as by release of hemoglobin from RBC membrane breakdown, our proposed model combines both these models. An experimental setup consisting of a Couette device was utilized for validation of our proposed model. Results A comparison is presented between the damage index (DI) predicted by the proposed model vs. the sublethal model vs. the nonthreshold model and experimental datasets. This comparison covers a wide range of shear stress for both human and porcine blood. An appropriate agreement between the measured DI and the DI predicted by the present model was obtained. Conclusions The semiempirical hemolysis model introduced in this paper aims for significantly enhanced conformity with experimental data. Two phenomenological outcomes become possible with the proposed approach: an estimation of the average time after which cell membrane breakdown occurs under the applied conditions, and a prediction of the ratio between the phenomena involved in hemolysis.}, language = {en} } @article{Lind2016, author = {Lind, Thorsten Patric}, title = {Insolvenzanfechtung: Keine Gl{\"a}ubigerbenachteiligung bei Abl{\"o}sezahlung gegen Forderungsverzicht}, series = {Der Betrieb}, volume = {69}, journal = {Der Betrieb}, number = {17}, publisher = {Fachmedien Otto Schmidt}, address = {D{\"u}sseldorf}, issn = {0005-9935}, pages = {999 -- 1001}, year = {2016}, abstract = {Schwerpunkt einer vorinsolvenzlichen Sanierung ist i.d.R., dass einzelne Gl{\"a}ubiger gegen Teilzahlungen auf ihre Forderungen verzichten und somit dem Unternehmen den notwendigen finanziellen Freiraum f{\"u}r einen Turnaround geben. Die Motivation der Gl{\"a}ubiger f{\"u}r einen Verzicht ist dabei auch die {\"U}berlegung, dass eine quotale Befriedigung im Rahmen eines Insolvenzverfahrens oft wesentlich geringer ausfallen w{\"u}rde als die durch den Vergleich realisierte Teilzahlung. Das Risiko, im Falle der Insolvenz eine Teilzahlung im Rahmen der Insolvenzanfechtung aber wieder zur{\"u}ckgew{\"a}hren zu m{\"u}ssen, macht einen Forderungsverzicht weniger attraktiv. Mit Urteil vom 28.01.2016 hat der BGH nun entschieden, dass eine Insolvenzanfechtung mangels Gl{\"a}ubigerbenachteiligung ausscheidet, wenn der in der Teilzahlung liegende Verm{\"o}gensverlust durch den damit verbundenen Verzicht auf die Restforderung voll ausgeglichen wird. Im Folgenden wird untersucht, ob dieses Urteil als Blaupause f{\"u}r eine anfechtungsfeste Restrukturierung einzelner Verbindlichkeiten dienen kann.}, language = {de} } @article{ArreolaMaetzkowDuranetal.2016, author = {Arreola, Julio and M{\"a}tzkow, Malte and Dur{\´a}n, Marlena Palomar and Greeff, Anton and Keusgen, Michael and Sch{\"o}ning, Michael Josef}, title = {Optimization of the immobilization of bacterial spores on glass substrates with organosilanes}, series = {Physica status solidi (A) : Applications and materials science}, volume = {213}, journal = {Physica status solidi (A) : Applications and materials science}, number = {6}, publisher = {Wiley-VCH}, address = {Weinheim}, issn = {1862-6319}, doi = {10.1002/pssa.201532914}, pages = {1463 -- 1470}, year = {2016}, abstract = {Spores can be immobilized on biosensors to function as sensitive recognition elements. However, the immobilization can affect the sensitivity and reproducibility of the sensor signal. In this work, three different immobilization strategies with organosilanes were optimized and characterized to immobilize Bacillus atrophaeus spores on glass substrates. Five different silanization parameters were investigated: nature of the solvent, concentration of the silane, silanization time, curing process, and silanization temperature. The resulting silane layers were resistant to a buffer solution (e.g., Ringer solution) with a polysorbate (e.g., Tween®80) and sonication.}, language = {en} } @article{WuPoghossianBronderetal.2016, author = {Wu, Chunsheng and Poghossian, Arshak and Bronder, Thomas and Sch{\"o}ning, Michael Josef}, title = {Sensing of double-stranded DNA molecules by their intrinsic molecular charge using the light-addressable potentiometric sensor}, series = {Sensors and Actuators B: Chemical}, journal = {Sensors and Actuators B: Chemical}, number = {229}, publisher = {Elsevier}, address = {Amsterdam}, issn = {0925-4005}, doi = {10.1016/j.snb.2016.02.004}, pages = {506 -- 512}, year = {2016}, abstract = {A multi-spot light-addressable potentiometric sensor (LAPS), which belongs to the family of semiconductor field-effect devices, was applied for label-free detection of double-stranded deoxyribonucleic acid (dsDNA) molecules by their intrinsic molecular charge. To reduce the distance between the DNA charge and sensor surface and thus, to enhance the electrostatic coupling between the dsDNA molecules and the LAPS, the negatively charged dsDNA molecules were electrostatically adsorbed onto the gate surface of the LAPS covered with a positively charged weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)). The surface potential changes in each spot of the LAPS, induced by the layer-by-layer adsorption of a PAH/dsDNA bilayer, were recorded by means of photocurrent-voltage and constant-photocurrent measurements. In addition, the surface morphology of the gate surface before and after consecutive electrostatic adsorption of PAH and dsDNA layers was studied by atomic force microscopy measurements. Moreover, fluorescence microscopy was used to verify the successful adsorption of dsDNA molecules onto the PAH-modified LAPS surface. A high sensor signal of 25 mV was registered after adsorption of 10 nM dsDNA molecules. The lower detection limit is down to 0.1 nM dsDNA. The obtained results demonstrate that the PAH-modified LAPS device provides a convenient and rapid platform for the direct label-free electrical detection of in-solution hybridized dsDNA molecules.}, language = {en} }