TY - JOUR A1 - Staat, Manfred T1 - Plastic collapse analysis of longitudinally flawed pipes and vessels N2 - Improved collapse loads of thick-walled, crack containing pipes and vessels are suggested. Very deep cracks have a residual strength which is better modelled by a global limit load. In all burst tests, the ductility of pressure vessel steels was sufficiently high whereby the burst pressure could be predicted by limit analysis with no need to apply fracture mechanics. The relative prognosis error increases however, for long and deep defects due to uncertainties of geometry and strength data. KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohr KW - Rohrbruch KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohrbruch KW - Fehlerstellen KW - pipes KW - vessels KW - load limit KW - burst tests KW - burst pressure KW - flaw Y1 - 2004 ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Peper, Andreas A1 - Bierbaum, Stefanie A1 - Albracht, Kirsten T1 - Plasticity of human Achilles tendon mechanical and morphological properties in response to cyclic strain JF - Journal of Biomechanics N2 - The purpose of the current study in combination with our previous published data (Arampatzis et al., 2007) was to examine the effects of a controlled modulation of strain magnitude and strain frequency applied to the Achilles tendon on the plasticity of tendon mechanical and morphological properties. Eleven male adults (23.9±2.2 yr) participated in the study. The participants exercised one leg at low magnitude tendon strain (2.97±0.47%), and the other leg at high tendon strain magnitude (4.72±1.08%) of similar frequency (0.5 Hz, 1 s loading, 1 s relaxation) and exercise volume (integral of the plantar flexion moment over time) for 14 weeks, 4 days per week, 5 sets per session. The exercise volume was similar to the intervention of our earlier study (0.17 Hz frequency; 3 s loading, 3 s relaxation) allowing a direct comparison of the results. Before and after the intervention ankle joint moment has been measured by a dynamometer, tendon–aponeurosis elongation by ultrasound and cross-sectional area of the Achilles tendon by magnet resonance images (MRI). We found a decrease in strain at a given tendon force, an increase in tendon–aponeurosis stiffness and tendon elastic modulus of the Achilles tendon only in the leg exercised at high strain magnitude. The cross-sectional area (CSA) of the Achilles tendon did not show any statistically significant (P>0.05) differences to the pre-exercise values in both legs. The results indicate a superior improvement in tendon properties (stiffness, elastic modulus and CSA) at the low frequency (0.17 Hz) compared to the high strain frequency (0.5 Hz) protocol. These findings provide evidence that the strain magnitude applied to the Achilles tendon should exceed the value, which occurs during habitual activities to trigger adaptational effects and that higher tendon strain duration per contraction leads to superior tendon adaptational responses. Y1 - 2010 U6 - http://dx.doi.org/10.1016/j.jbiomech.2010.08.014 SN - 0021-9290 VL - 43 IS - 16 SP - 3073 EP - 3079 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Karamanidis, Kiros A1 - Mademli, Lida A1 - Albracht, Kirsten T1 - Plasticity of the human tendon to short and long-term mechanical loading JF - Exercise and Sport Sciences Reviews Y1 - 2009 U6 - http://dx.doi.org/10.1097/JES.0b013e31819c2e1d SN - 1538-3008 VL - 37 IS - 2 SP - 66 EP - 72 ER - TY - JOUR A1 - Michael, Hackl A1 - Mayer, Katharina A1 - Weber, Mareike A1 - Staat, Manfred A1 - van Riet, Roger A1 - Burkhart, Klau Josef A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - Plate osteosynthesis of proximal ulna fractures : a biomechanical micromotion analysis JF - The journal of hand surgery Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.jhsa.2017.05.014 SN - 0363-5023 VL - 42 IS - 10 SP - 834.e1 EP - 834.e7 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Maggakis-Kelemen, Christina A1 - Digel, Ilya A1 - Artmann, Gerhard T1 - Polystyrene sulfonate/Polyallylamine hydrochloride microcapsules as potential artificial red blood cells - improvement of capsule flexibility JF - Biomedizinische Technik. 50 (2005), H. Erg.-Bd. 1 Y1 - 2005 SP - 324 EP - 326 ER - TY - JOUR A1 - Ciritsis, Alexander A1 - Horbach, Andreas A1 - Staat, Manfred A1 - Kuhl, Christiane K. A1 - Kraemer, Nils Andreas T1 - Porosity and tissue integration of elastic mesh implants evaluated in vitro and in vivo JF - Journal of Biomedical Materials Research: Part B: Applied Biomaterials N2 - Purpose In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model. Material and Methods Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio). Results In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF. Conclusion The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827–833, 2018. Y1 - 2018 U6 - http://dx.doi.org/10.1002/jbm.b.33877 SN - 1552-4981 VL - 106 IS - 2 SP - 827 EP - 833 PB - Wiley CY - New York, NY ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Kozlova, Tatiana V. A1 - Lanzl, Ines M. T1 - Postoperative aqueous outflow in the human eye after glaucoma filtration surgery: biofluidmechanical considerations JF - Biomedizinische Technik = Biomedical Engineering Y1 - 2009 SN - 1862-278X VL - 54 IS - 1 SP - 14 EP - 22 PB - - ER - TY - JOUR A1 - Jayaraman, Chandrasekaran A1 - Mummidisetty, Chaitanya Krishna A1 - Loesch, Alexandra A1 - Kaur, Sandi A1 - Hoppe-Ludwig, Shenan A1 - Staat, Manfred A1 - Jayaraman, Arun T1 - Postural and metabolic benefits of using a forearm support walker in older adults with impairments JF - Archives of Physical Medicine and Rehabilitation Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.apmr.2018.10.001 SN - 0003-9993 VL - Volume 100 IS - Issue 4 SP - 638 EP - 647 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dachwald, Bernd A1 - Baturkin, Volodymyr A1 - Coverstone, Victoria L. A1 - Dietrich, Benjamin A1 - Garbe, Gregory P. A1 - Görlich, Marianne A1 - Leipold, Manfred A1 - Lura, Franz A1 - Macdonald, Malcolm A1 - McInnes, Colin R. A1 - Mengali, Giovanni A1 - Quatra, Alessandro A. A1 - Rios-Reyes, Leonel A1 - Scheeres, Daniel J. A1 - Seboldt, Wolfgang A1 - Wie, Bong T1 - Potential Effects of Optical Solar Sail Degradation on Interplanetary Trajectory Design JF - Astrodynamics 2005 : proceedings of the AAS/AIAA astrodynamics conference held August 7 - 11, 2005, South Lake Tahoe, California / ed. by Bobby G. Williams. - Pt. 3. - (Advances in the astronautical sciences ; 123,3) Y1 - 2006 UR - http://www.spacesailing.net/paper/200508_LakeTahoe_Dachwald+.pdf SN - 0-87703-527-X N1 - Astrodynamics Conference <2005, South Lake Tahoe, Calif.> ; American Astronautical Society ; Number: AAS-05-413 SP - 2569 EP - 2592 PB - Univelt CY - San Diego, Calif. ER - TY - JOUR A1 - Dachwald, Bernd A1 - Seboldt, Wolfgang A1 - Macdonald, Malcolm A1 - Mengali, Giovanni A1 - Quatra, Alessandro A. A1 - McInnes, Colin R. A1 - Rios-Reyes, Leonel A1 - Scheerers, Daniel J. A1 - Wie, Bong A1 - Görlich, Marianne A1 - Lura, Franz A1 - Diedrich, Benjamin A1 - Baturkin, Volodymyr A1 - Coverstone, Victoria L. A1 - Leipold, Manfred A1 - Garbe, Gregory P. T1 - Potential Solar Sail Degradation Effects on Trajectory and Attitude Control JF - AIAA Guidance, Navigation and Control Conference and Exhibit - AIAA Modeling and Simulation Technologies Conference and Exhibit - AIAA Atmospheric Flight Mechanics Conference and Exhibit : [San Francisco, California, 15 - 18 August 2005 ; papers]. - (AIAA meeting papers on disc ; [10.]2005,16-17) Y1 - 2005 SN - 1-56347-765-3 N1 - American Institute of Aeronautics and Astronautics ; AIAA Guidance, Navigation, and Control Conference and Exhibit <2005, San Francisco, Calif.> ; AIAA paper number: AIAA-2006-6172 Link "https://arc.aiaa.org/doi/book/10.2514/MGNC05" am 15.07.2022 nachgetragen Behr PB - American Institute of Aeronautics and Astronautics CY - Reston, Va. ER -