TY - JOUR A1 - Staat, Manfred T1 - Failure probabilities of the primary circuit pressure boundary of an HTR-Module for process heat generation under accident conditions for different failure modes JF - Nuclear Engineering and Design. 144 (1993), H. 1 Y1 - 1993 SN - 0029-5493 SP - 53 EP - 67 ER - TY - JOUR A1 - Lapitan, Denis G. A1 - Rogatkin, Dmitrii A. A1 - Persheyev, Sydulla K. A1 - Kotliar, Konstantin T1 - False spectra formation in the differential two-channel scheme of the laser Doppler flowmeter JF - Biomedizinische Technik N2 - Noise in the differential two-channel scheme of a classic laser Doppler flowmetry (LDF) instrument was studied. Formation of false spectral components in the output signal due to beating of electrical signals in the differential amplifier was found out. The improved block-diagram of the flowmeter was developed allowing to reduce the noise. Y1 - 2018 U6 - http://dx.doi.org/10.1515/bmt-2017-0060 SN - 0013-5585 VL - 63 IS - 4 SP - 439 EP - 444 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Leimena, W. A1 - Artmann, Gerhard A1 - Dachwald, Bernd A1 - Temiz Artmann, Aysegül A1 - Gossmann, Matthias A1 - Digel, Ilya T1 - Feasibility of an in-situ microbial decontamination of an ice-melting probe JF - Eurasian Chemico-Technological Journal. 12 (2010), H. 2 Y1 - 2010 SN - 1562-3920 SP - 145 EP - 150 ER - TY - JOUR A1 - Tran, Ngoc Trinh A1 - Trinh, Tu Luc A1 - Dao, Ngoc Tien A1 - Giap, Van Tan A1 - Truong, Manh Khuyen A1 - Dinh, Thuy Ha A1 - Staat, Manfred T1 - FEM shakedown analysis of structures under random strength with chance constrained programming JF - Vietnam Journal of Mechanics N2 - Direct methods, comprising limit and shakedown analysis, are a branch of computational mechanics. They play a significant role in mechanical and civil engineering design. The concept of direct methods aims to determine the ultimate load carrying capacity of structures beyond the elastic range. In practical problems, the direct methods lead to nonlinear convex optimization problems with a large number of variables and constraints. If strength and loading are random quantities, the shakedown analysis can be formulated as stochastic programming problem. In this paper, a method called chance constrained programming is presented, which is an effective method of stochastic programming to solve shakedown analysis problems under random conditions of strength. In this study, the loading is deterministic, and the strength is a normally or lognormally distributed variable. KW - limit analysis KW - shakedown analysis KW - chance constrained programming KW - stochastic programming KW - reliability of structures Y1 - 2022 U6 - http://dx.doi.org/10.15625/0866-7136/17943 SN - 0866-7136 SN - 2815-5882 VL - 44 IS - 4 SP - 459 EP - 473 PB - Vietnam Academy of Science and Technology (VAST) ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - FEM-based shakedown analysis of hardening structures JF - Asia Pacific journal on computational engineering N2 - This paper develops a new finite element method (FEM)-based upper bound algorithm for limit and shakedown analysis of hardening structures by a direct plasticity method. The hardening model is a simple two-surface model of plasticity with a fixed bounding surface. The initial yield surface can translate inside the bounding surface, and it is bounded by one of the two equivalent conditions: (1) it always stays inside the bounding surface or (2) its centre cannot move outside the back-stress surface. The algorithm gives an effective tool to analyze the problems with a very high number of degree of freedom. Our numerical results are very close to the analytical solutions and numerical solutions in literature. Y1 - 2014 U6 - http://dx.doi.org/10.1186/2196-1166-1-4 SN - 2196-1166 (E-Journal) IS - 1 SP - Article No. 4 PB - SpringerOpen CY - Berlin ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - FEM-computation of load carrying capacity of highly loaded passive components by direct methods. Heitzer, M. ; Staat, M. JF - Nuclear Engineering and Design. 193 (1999), H. 3 Y1 - 1999 SN - 0029-5493 SP - 349 EP - 358 ER - TY - JOUR A1 - Baader, Fabian A1 - Boxberg, Marc S. A1 - Chen, Qian A1 - Förstner, Roger A1 - Kowalski, Julia A1 - Dachwald, Bernd T1 - Field-test performance of an ice-melting probe in a terrestrial analogue environment JF - Icarus N2 - Melting probes are a proven tool for the exploration of thick ice layers and clean sampling of subglacial water on Earth. Their compact size and ease of operation also make them a key technology for the future exploration of icy moons in our Solar System, most prominently Europa and Enceladus. For both mission planning and hardware engineering, metrics such as efficiency and expected performance in terms of achievable speed, power requirements, and necessary heating power have to be known. Theoretical studies aim at describing thermal losses on the one hand, while laboratory experiments and field tests allow an empirical investigation of the true performance on the other hand. To investigate the practical value of a performance model for the operational performance in extraterrestrial environments, we first contrast measured data from terrestrial field tests on temperate and polythermal glaciers with results from basic heat loss models and a melt trajectory model. For this purpose, we propose conventions for the determination of two different efficiencies that can be applied to both measured data and models. One definition of efficiency is related to the melting head only, while the other definition considers the melting probe as a whole. We also present methods to combine several sources of heat loss for probes with a circular cross-section, and to translate the geometry of probes with a non-circular cross-section to analyse them in the same way. The models were selected in a way that minimizes the need to make assumptions about unknown parameters of the probe or the ice environment. The results indicate that currently used models do not yet reliably reproduce the performance of a probe under realistic conditions. Melting velocities and efficiencies are constantly overestimated by 15 to 50 % in the models, but qualitatively agree with the field test data. Hence, losses are observed, that are not yet covered and quantified by the available loss models. We find that the deviation increases with decreasing ice temperature. We suspect that this mismatch is mainly due to the too restrictive idealization of the probe model and the fact that the probe was not operated in an efficiency-optimized manner during the field tests. With respect to space mission engineering, we find that performance and efficiency models must be used with caution in unknown ice environments, as various ice parameters have a significant effect on the melting process. Some of these are difficult to estimate from afar. Y1 - 2023 U6 - http://dx.doi.org/10.1016/j.icarus.2023.115852 N1 - Forschungsdaten hierzu: "Performance data of an ice-melting probe from field tests in two different ice environments" (https://opus.bibliothek.fh-aachen.de/opus4/frontdoor/index/index/docId/10890) IS - 409 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Novacek, V. A1 - Tran, Thanh Ngoc A1 - Klinge, U. A1 - Tolba, R. H. A1 - Staat, Manfred A1 - Bronson, D. G. A1 - Miesse, A. M. A1 - Whiffen, J. A1 - Turquier, F. T1 - Finite element modelling of stapled colorectal end-to-end anastomosis : Advantages of variable height stapler design JF - Journal of Biomechanics N2 - The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge. KW - Variable height stapler design KW - Anastomotic leakage KW - Finite element modelling KW - End-to-end colorectal anastomosis KW - Surgical staplers Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jbiomech.2012.07.021 SN - 1873-2380 VL - 45 IS - 115 SP - 2693 EP - 2697 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dachwald, Bernd A1 - Schmidt, Tanja D. A1 - Seboldt, Wolfgang A1 - Auweter-Kurtz, T1 - Flight Opportunities from Mars to Earth for Piloted Missions Using Continuous Thrust Propulsion / Schmidt, Tanja D. ; Dachwald, Bernd ; Seboldt, Wolfgang ; Auweter-Kurtz, Monika Y1 - 2003 N1 - 39th AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit 20-23 July 2003, Huntsville, Alabama ; AIAA 2003-4573 SP - 1 EP - 9 PB - - ER - TY - JOUR A1 - Scholz, A. A1 - Ley, Wilfried A1 - Dachwald, Bernd A1 - Miau, J. J. A1 - Juang, J. C. T1 - Flight results of the COMPASS-1 picosatellite mission JF - Acta Astronautica. 67 (2010), H. 9-10 Y1 - 2010 SN - 0094-5765 SP - 1289 EP - 1298 ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Flight style optimization in ski jumping on normal, large, and ski flying hills JF - Journal of biomechanics Y1 - 2013 SN - 1873-2380 (E-Journal); 0021-9290 (Print) N1 - Corrigendum to “Flight style optimization in ski jumping on normal, large, and ski flying hills” [J. Biomech 47 (2014) 716-722] Journal of Biomechanics, 2018;71:313. VL - Vol. 47 IS - Iss. 3 SP - 716 EP - 722 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Artmann, Gerhard A1 - Hueck, Isgard S. A1 - Rossiter, Katharine A1 - Schmid-Schönbein, Geert W. T1 - Fluid Shear Attenuates Endothelial Pseudopodia Formation into the Capillary Lumen / Hueck, Isgard S. ; Rossiter, Katharine ; Artman, Gerhard M. ; Schmid-Schönbein, Geert W. JF - Microcirculation. 15 (2008), H. 6 Y1 - 2008 SN - 1549-8719 SP - 531 EP - 542 ER - TY - JOUR A1 - Digel, Ilya A1 - Demirci, Taylan A1 - Temiz Artmann, Aysegül A1 - Nishikawa, K. T1 - Free Radical Nature of the Bactericidal Effect of Plasma-Generated Cluster Ions (PCIs) JF - Biomedizinische Technik. 49 (2004), H. Erg.-Bd. 2 Y1 - 2004 SN - 0932-4666 SP - 982 EP - 983 ER - TY - JOUR A1 - Stadler, Andreas M. A1 - Digel, Ilya A1 - Embs, Jan P. A1 - Unruh, Tobias A1 - Tehei, M. A1 - Zaccai, G. A1 - Büldt, G. A1 - Artmann, Gerhard T1 - From powder to solution : Hydration dependence of human hemoglobin dynamics correlated to body temperature JF - Biophysical Journal. 96 (2009), H. 12 Y1 - 2009 SN - 0006-3495 SP - 5073 EP - 5081 PB - Cell Press CY - Cambridge, Mass. ER - TY - JOUR A1 - Artmann, Gerhard A1 - Zang, Werner T1 - Fully automatic measurement of rheologic parameters of red blood cells = Laborautomat zur Messung mechanischer Eigenschaften roter Blutzellen JF - Biomedizinische Technik = Biomedical engineering. 35 (1990), H. Suppl. 3 Y1 - 1990 SN - 0013-5585 SP - 94 EP - 96 ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Nagel, Edgar A1 - Vilser, Walthard A1 - Lanzl, Ines M. T1 - Functional in vivo assessment of retinal artery microirregularities in glaucoma / Kotliar, Konstantin E. ; Nagel, Edgar ; Vilser, Walthard ; Lanzl, Ines M. JF - Acta Ophthalmologica. 86 (2008), H. 4 Y1 - 2008 SN - 1755-3768 SP - 424 EP - 433 PB - - ER - TY - JOUR A1 - Seidova, Seid-Fatima A1 - Kotliar, Konstantin A1 - Foerger, Frauke A1 - Klopfer, Matthias A1 - Lanzl, Ines T1 - Functional retinal changes in Gaucher disease JF - Documenta Ophthalmologica Y1 - 2009 SN - 1573-2622 VL - 118 IS - 2 SP - 151 EP - 154 PB - Springer CY - Berlin ER - TY - JOUR A1 - Dachwald, Bernd A1 - Turyshev, Slava G. A1 - Dittus, H. A1 - Shao, M. [u.a.] T1 - Fundamental Physics with the Laser Astrometric Test Of Relativity / S.G. Turyshev ; H. Dittus ; M. Shao ... B.Dachwald ... JF - Proceedings of the 39th ESLAB Symposium "Trends in Space Science and Cosmic Vision 2020" : 19 - 21 April 2005, ESTEC, Noordwijk, the Netherlands / European Space Agency. [Comp. by: F. Favata ...] . - (ESA SP ; 588) Y1 - 2005 SN - 9290928999 N1 - ISBN der CD-ROM-Ausg.: 9290928999 ; Symposium Trends in Space Science and Cosmic Vision 2020 <2005, Noordwijk> ; ESLAB symposium <39, 2005, Noordwijk> ; European Space Laboratory SP - 8 EP - 11 PB - ESA Publ. Div. CY - Noordwijk ER - TY - JOUR A1 - Richter, Charlotte A1 - Braunstein, Björn A1 - Stäudle, Benjamin A1 - Attias, Julia A1 - Süss, Alexander A1 - Weber, Tobias A1 - Mileva, Katya N. A1 - Rittweger, Jörn A1 - Green, David A. A1 - Albracht, Kirsten T1 - Gastrocnemius medialis contractile behavior during running differs between simulated Lunar and Martian gravities JF - Scientific reports N2 - The international partnership of space agencies has agreed to proceed forward to the Moon sustainably. Activities on the Lunar surface (0.16 g) will allow crewmembers to advance the exploration skills needed when expanding human presence to Mars (0.38 g). Whilst data from actual hypogravity activities are limited to the Apollo missions, simulation studies have indicated that ground reaction forces, mechanical work, muscle activation, and joint angles decrease with declining gravity level. However, these alterations in locomotion biomechanics do not necessarily scale to the gravity level, the reduction in gastrocnemius medialis activation even appears to level off around 0.2 g, while muscle activation pattern remains similar. Thus, it is difficult to predict whether gastrocnemius medialis contractile behavior during running on Moon will basically be the same as on Mars. Therefore, this study investigated lower limb joint kinematics and gastrocnemius medialis behavior during running at 1 g, simulated Martian gravity, and simulated Lunar gravity on the vertical treadmill facility. The results indicate that hypogravity-induced alterations in joint kinematics and contractile behavior still persist between simulated running on the Moon and Mars. This contrasts with the concept of a ceiling effect and should be carefully considered when evaluating exercise prescriptions and the transferability of locomotion practiced in Lunar gravity to Martian gravity. KW - Bone quality and biomechanics KW - Environmental impact KW - Skeletal muscle KW - Tendons KW - Ultrasound Y1 - 2021 U6 - http://dx.doi.org/10.1038/s41598-021-00527-9 SN - 2045-2322 N1 - Corresponding author: Charlotte Richter VL - 11 IS - Article number: 22555 PB - Springer Nature CY - London ER - TY - JOUR A1 - Richter, Charlotte A1 - Braunstein, Bjoern A1 - Stäudle, Benjamin A1 - Attias, Julia A1 - Suess, Alexander A1 - Weber, Tobias A1 - Mileva, Katja N. A1 - Rittweger, Joern A1 - Green, David A. A1 - Albracht, Kirsten T1 - Gastrocnemius medialis contractile behavior is preserved during 30% body weight supported gait training JF - Frontiers in Sports and Active Living N2 - Rehabilitative body weight supported gait training aims at restoring walking function as a key element in activities of daily living. Studies demonstrated reductions in muscle and joint forces, while kinematic gait patterns appear to be preserved with up to 30% weight support. However, the influence of body weight support on muscle architecture, with respect to fascicle and series elastic element behavior is unknown, despite this having potential clinical implications for gait retraining. Eight males (31.9 ± 4.7 years) walked at 75% of the speed at which they typically transition to running, with 0% and 30% body weight support on a lower-body positive pressure treadmill. Gastrocnemius medialis fascicle lengths and pennation angles were measured via ultrasonography. Additionally, joint kinematics were analyzed to determine gastrocnemius medialis muscle–tendon unit lengths, consisting of the muscle's contractile and series elastic elements. Series elastic element length was assessed using a muscle–tendon unit model. Depending on whether data were normally distributed, a paired t-test or Wilcoxon signed rank test was performed to determine if body weight supported walking had any effects on joint kinematics and fascicle–series elastic element behavior. Walking with 30% body weight support had no statistically significant effect on joint kinematics and peak series elastic element length. Furthermore, at the time when peak series elastic element length was achieved, and on average across the entire stance phase, muscle–tendon unit length, fascicle length, pennation angle, and fascicle velocity were unchanged with respect to body weight support. In accordance with unchanged gait kinematics, preservation of fascicle–series elastic element behavior was observed during walking with 30% body weight support, which suggests transferability of gait patterns to subsequent unsupported walking. KW - AlterG KW - rehabilitation KW - gait KW - walking KW - ultrasound imaging KW - series elastic element behavior KW - muscle fascicle behavior KW - unloading Y1 - 2021 U6 - http://dx.doi.org/10.3389/fspor.2020.614559 SN - 2624-9367 VL - 2021 IS - 2 PB - Frontiers CY - Lausanne ER -