TY - JOUR A1 - Pressler, Axel A1 - Esefeld, Katrin A1 - Scherr, Johannes A1 - Ali, Mohammad A1 - Hanssen, Henner A1 - Kotliar, Konstantin A1 - Lanzl, Ines A1 - Halle, Martin A1 - Kaemmerer, Harald A1 - Schmidt-Trucksäss, Arno A1 - Hager, Alfred T1 - Structural alterations of retinal arterioles in adults late after repair of aortic isthmic coarctation JF - The American Journal of Cardiology N2 - Patients after coarctation repair still have an increased risk of cardiovascular or cerebrovascular events. This has been explained by the persisting hypertension and alterations in the peripheral vessels. However, involvement of the central vessels such as the retinal arteries is virtually unknown. A total of 34 patients after coarctation repair (22 men and 12 women; 23 to 58 years old, age range 0 to 32 years at surgical repair) and 34 nonhypertensive controls underwent structural and functional retinal vessel analysis. Using structural analysis, the vessel diameters were measured. Using functional analysis, the endothelium-dependent vessel dilation in response to flicker light stimulation was assessed. In the patients after coarctation repair, the retinal arteriolar diameter was significantly reduced compared to that of the controls (median 182 μm, first to third quartile 171 to 197; vs 197 μm, first to third quartile 193 to 206; p <0.001). These findings were independent of the peripheral blood pressure and age at intervention. No differences were found for venules. The functional analysis findings were not different between the patients and controls (maximum dilation 3.5%, first to third quartile 2.1% to 4.5% vs 3.6%, first to third quartile 2.2% to 4.3%; p = 0.81), indicating preserved autoregulative mechanisms. In conclusion, the retinal artery diameter is reduced in patients after coarctation repair, independent of their current blood pressure level and age at intervention. As a structural marker of chronic vessel damage associated with past, current, or future hypertension, retinal arteriolar narrowing has been linked to stroke incidence. These results indicate an involvement of cerebral microcirculation in aortic coarctation, despite timely repair, and might contribute to explain the increased rate of cerebrovascular events in such patients. Y1 - 2010 U6 - http://dx.doi.org/10.1016/j.amjcard.2009.10.070 SN - 0002-9149 VL - 105 IS - 5 SP - 740 EP - 744 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Nagel, Edgar A1 - Vilser, Walthard A1 - Seidova, Seid-Fatima A1 - Lanzl, Ines T1 - Microstructural alterations of retinal arterial blood column along the vessel axis in systemic hypertension JF - Investigative Ophthalmology & Visual Science, IOVS N2 - Purpose: Image analysis by the retinal vessel analyzer (RVA) observes retinal vessels in their dynamic state online noninvasively along a chosen vessel segment. It has been found that high-frequency diameter changes in the retinal artery blood column along the vessel increase significantly in anamnestically healthy volunteers with increasing age and in patients with glaucoma during vascular dilation. This study was undertaken to investigate whether longitudinal sections of the retinal artery blood column are altered in systemic hypertension. Methods: Retinal arteries of 15 untreated patients with essential arterial hypertension (age, 50.9 ± 11.9 years) and of 15 age-matched anamnestically healthy volunteers were examined by RVA. After baseline assessment, a monochromatic luminance flicker (530–600 nm; 12.5 Hz; 20 s) was applied to evoke retinal vasodilation. Differences in amplitude and frequency of spatial artery blood column diameter change along segments (longitudinal arterial profiles) of 1 mm in length were measured and analyzed using Fourier transformation. Results: In the control group, average reduced power spectra (ARPS) of longitudinal arterial profiles did not differ when arteries changed from constriction to dilation. In the systemic hypertension group, ARPS during constriction, baseline, and restoration were identical and differed from ARPS during dilation (P < 0.05). Longitudinal arterial profiles in both groups showed significant dissimilitude at baseline and restoration (P < 0.05). Conclusions: The retinal artery blood column demonstrates microstructural alterations in systemic hypertension and is less irregular along the vessel axis during vessel dilation. These microstructural changes may be an indication of alterations in vessel wall rigidity, vascular endothelial function, and smooth muscle cells in this disease, leading to impaired perfusion and regulation. Y1 - 2010 U6 - http://dx.doi.org/10.1167/iovs.09-3649 SN - 0146-0404 VL - 51 IS - 4 SP - 2165 EP - 2172 PB - ARVO CY - Rockville, Md. ER - TY - CHAP A1 - Arinkin, Vladimir A1 - Digel, Ilya T1 - Water bridge phenomenon : [abstract] N2 - One of interesting but not well known water properties is related to appearance of highly ordered structures in response to strong electrical field. In 1893 Sir William Armstrong placed a cotton thread between two wine glasses filled with chemically pure water. When high DC voltage was applied between the glasses, a connection consisting of water formed, producing a "water bridge" KW - Hydrodynamik KW - Elektrodynamik KW - Wasserbrücke KW - water bridge phenomenon Y1 - 2009 ER - TY - CHAP A1 - ElBashir, Rasha A1 - Digel, Ilya T1 - Effect of nitric oxide gas on hydrogels : [abstract] N2 - The results support our theory that the NO gas has an influence in increasing the translational diffusion of hydrogels and it accelerates the melting process of the gels. KW - Stickstoffmonoxid KW - Hydrogel KW - nitric oxide gas KW - hydrogel Y1 - 2009 ER - TY - CHAP A1 - O\'Heras, Carlos A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül T1 - Nanostructured carbon-based column for LPS/protein adsorption : [abstract] N2 - The absence of a general method for endotoxin removal from liquid interfaces gives an opportunity to find new methods and materials to overcome this gap. Activated nanostructured carbon is a promising material that showed good adsorption properties due to its vast pore network and high surface area. The aim of this study is to find the adsorption rates for a carboneous material produced at different temperatures, as well as to reveal possible differences between the performance of the material for each of the adsorbates used during the study (hemoglobin, serum albumin and lipopolysaccharide, LPS). KW - Kohlenstofffaser KW - Adsorption KW - Lipopolysaccharide KW - aktivierte nanostrukturierte Kohlenstofffaser KW - lipopolysaccharides KW - activated nanostructured carbon Y1 - 2009 ER - TY - CHAP A1 - Bassam, Rasha A1 - Digel, Ilya A1 - Artmann, Gerhard T1 - Effect of nitric oxide on protein thermal stability : [abstract] N2 - As a deduction from these results, we can conclude that proteins mainly in vitro, denaturate totally at a temperature between 57°C -62°C, and they also affected by NO and different ions types. In which mainly, NO cause earlier protein denaturation, which means that, NO has a destabilizing effect on proteins, and also different ions will alter the protein denaturation in which, some ions will cause earlier protein denaturation while others not. KW - Stickstoffmonoxid KW - Proteine KW - Hämoglobin KW - nitric oxide gas KW - protein KW - hemoglobin Y1 - 2009 ER - TY - CHAP A1 - Digel, Ilya A1 - Dachwald, Bernd A1 - Artmann, Gerhard A1 - Linder, Peter A1 - Funke, O. T1 - A concept of a probe for particle analysis and life detection in icy environments N2 - A melting probe equipped with autofluorescence-based detection system combined with a light scattering unit, and, optionally, with a microarray chip would be ideally suited to probe icy environments like Europa’s ice layer as well as the polar ice layers of Earth and Mars for recent and extinct live. KW - Sonde KW - Eisschicht KW - Autofluoreszenzverfahren KW - Lichtstreuungsbasierte Instrumente KW - autofluorescence-based detection system KW - light scattering analysis Y1 - 2009 ER - TY - JOUR A1 - Dachwald, Bernd A1 - Ohndorf, A. A1 - Gill, E. T1 - Optimization of low-thrust Earth-Moon transfers using evolutionary neurocontrol / Ohndorf, A. ; Dachwald, B. ; Gill, E. JF - IEEE Congress on Evolutionary Computation, 2009. CEC '09. Y1 - 2009 SN - 978-1-4244-2958-5 SP - 358 EP - 364 ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Kreißig, R. A1 - Staat, Manfred T1 - Probabilistic limit and shakedown analysis of thin plates and shells JF - Structural safety. 31 (2009), H. 1 Y1 - 2009 SN - 0167-4730 SP - 1 EP - 18 PB - - ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Pham, Phu Tinh A1 - Vu, D. K. A1 - Staat, Manfred T1 - Reliability Analysis of Inelastic Shell Structures Under Variable Loads JF - Limit States of Materials and Structures : Direct Methods / Hrsg. Dieter Weichert; Hrsg. Alan Ponter Y1 - 2009 SN - 978-1-4020-9633-4 SP - 135 EP - 156 PB - Springer Netherland CY - Berlin ER - TY - JOUR A1 - Artmann, Gerhard A1 - Digel, Ilya A1 - Zerlin, Kay A1 - Maggakis-Kelemen, Christina A1 - Linder, Peter A1 - Porst, Dariusz A1 - Kayser, Peter A1 - Stadler, David A1 - Dikta, Gerhard A1 - Temiz Artmann, Aysegül T1 - Hemoglobin senses body temperature JF - European Biophysics Journal Y1 - 2009 SN - 0175-7571 VL - 38 IS - 5 SP - 589 EP - 600 ER - TY - JOUR A1 - Sadykov, Rustam A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül A1 - Porst, Dariusz A1 - Linder, Peter A1 - Kayser, Peter A1 - Artmann, Gerhard A1 - Savitskaya, Irina A1 - Zhubanova, Azhar T1 - Oral lead exposure induces dysbacteriosis in rats JF - Journal of Occupational Health. 51 (2009) (2009), H. 1 Y1 - 2009 SN - 1348-9585 SP - 64 EP - 73 ER - TY - JOUR A1 - Demirci, Taylan A1 - Kurulgan Demirci, Eylem A1 - Trzewik, Jürgen A1 - Linder, Peter A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Sakizli, Meral A1 - Temiz Artmann, Aysegül T1 - Gene expression profile analysis of 3T3/NIH fibroblasts after one hour mechanical stress JF - IUBMB Life. 61 (2009), H. 3 Y1 - 2009 SN - 1521-6543 N1 - Abstracts: Turkish Society of Molecular Medicine, Third International Congress of Molecular Medicine, May 5-8, 2009, Istanbul, Turkey SP - 311 EP - 312 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Dachwald, Bernd A1 - Carnelli, Ian A1 - Vasile, Massimiliano T1 - Evolutionary Neurocontrol: A Novel Method for Low-Thrust Gravity-Assist Trajectory Optimization / Carnelli, Ian ; Dachwald, Bernd ; Vasile, Massimiliano JF - Journal of guidance control and dynamics. 32 (2009), H. 2 Y1 - 2009 SN - 0731-5090 SP - 616 EP - 625 PB - AIAA CY - Reston, Va. ER - TY - JOUR A1 - Dachwald, Bernd A1 - Ball, Andrew J. A1 - Ulamec, Stephan A1 - Price, Michael E. T1 - A small mission for in situ exploration of a primitive binary near-Earth asteroid / Ball, Andrew J. ; Ulamec, Stephan ; Dachwald, Bernd ; Price, Michael E. ; [u.a.] JF - Advances in Space Research. 43 (2009), H. 2 Y1 - 2009 SN - 0273-1177 SP - 317 EP - 324 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Amin, Rashid A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard A1 - Lazarovici, Philip A1 - Lelkes, Peter I. T1 - Permeability of an In Vitro Model of Blood Brain Barrier (BBB) JF - 13th International Conference on Biomedical Engineering / Lim, Chwee Teck [Ed.] Y1 - 2009 SN - 978-3-540-92841-6 N1 - IFMBE Proceedings ; 23, Track 1 ; ICBME 2008 3–6 December 2008 Singapore SP - 81 EP - 84 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, M. A1 - Hormes, M. A1 - Steinseifer, U. A1 - Arora, D. A1 - Coronado, O. A1 - Pasquali, M. T1 - A Review of Computational Fluid Dynamics Analysis of Blood Pumps JF - European Journal of Applied Mathematics. 20 (2009), H. 4 Y1 - 2009 SP - 363 EP - 397 PB - Cambridge Univ. Press CY - Cambridge ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Finocchiaro, Thomas A1 - Heinke, Stefanie A1 - Leßmann, Marc T1 - Methods of design, simulation, and control for the development of new VAD/TAH concepts = Methoden zur Konstruktion, Simulation und Regelung für die Entwicklung von neuen VAD/TAH-Konzepten / Finocchiaro, Thomas ; Heinke, Stefanie ; Behbahani, Mehdi ; Leßma JF - Biomedizinische Technik / Biomedical Engineering. 54 (2009), H. 5 Y1 - 2009 SN - 0013-5585 N1 - Printausgabe in der Bereichsbibliothek Jülich vorhanden : 63 Z 471 SP - 269 EP - 281 ER - TY - JOUR A1 - Steinseifer, Ulrich A1 - Kashefi, Ali A1 - Hormes, Marcus A1 - Schoberer, Mark A1 - Orlikowsky, Thorsten A1 - Behbahani, Mehdi A1 - Behr, Marek A1 - Schmitz-Rode, Thomas T1 - Miniaturization of ECMO Systems : Engineering Challenges and Methods JF - Artificial Organs. 33 (2009), H. 5 Y1 - 2009 SN - 1525-1594 N1 - Fifth International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion Abstracts SP - A55 EP - A55 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Tran, L. A1 - Waluga, C. A1 - Behr, M. A1 - Oedekoven, B. A1 - Mottaghy, K. T1 - Model-based Numerical Analysis of Platelet Adhesion, Thrombus Growth and Aggregation for Assist Devices JF - The International Journal of Artificial Organs. 32 (2009), H. 7 Y1 - 2009 SN - 0391-3988 N1 - Abstracts - Oral Presentations: XXXVI Annual ESAO Congress, 2-5 September 2009, Compiègne - France; European Society of Artificial Organs (ESAO), Compiegne, France, September 2-5, 2009 SP - 398 EP - 398 ER -